Michele Schiavo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michele Schiavo has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Antonio Visioli
University of Brescia
14 shared publications - Nicola Latronico
University Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, Università di Brescia, Brescia, Italy
11 shared publications Massimiliano Paltenghi
Spedali Civili di Brescia, Brescia, Italy
8 shared publications- Andrzej Pawlowski
Dipartimento di Ingegneria Meccanica e Industriale, University of Brescia, Brescia, Italy
5 shared publications - Fabrizio Padula
Curtin Centre for Optimisation and Decision Science, Curtin University, Bentley, WA 6102, Australia
4 shared publications - Massimiliano Paltenghi
Department of Anesthesiology, Critical Care and Emergency, Spedali Civili di Brescia, Brescia, Italy
4 shared publications
Latest Publications
- Open Access
- 1 August 2026
- Published by Springer Nature in Communications Medicine
- Vol. 6 (1) , 425
Systemic fragility in European total intravenous anesthesia delivery and opportunities for resilient real-time decision support
Total intravenous anesthesia (TIVA) is a well-established technique for general anesthesia and is increasingly relevant to Europe’s transition toward more digital, sustainable, and patient-centred healthcare. However, its use remains uneven across centres and still depends heavily on population-based drug models, variable monitoring practices, and repeated clinician adjustment. Differences in training, data access, device compatibility, patient response, and institutional resources can limit safe and consistent personalization. In this Review, we examine the main sources of fragility in current TIVA practice and discuss how interoperable perioperative data, digital patient simulators, patient-adaptive models, multimodal monitoring, and closed-loop decision support could improve safety and resilience. We emphasize that these technologies should support, not replace, the anesthesiologist, and should remain transparent, clinically supervised, and easy to override. We conclude by outlining priorities for European collaboration in data infrastructure, training, validation, regulation, and evaluation of AI-enabled tools.
- 1 August 2026
- Published by Springer Nature in Communications Medicine
- Vol. 6 (1) , 425
Open AccessSystemic fragility in European total intravenous anesthesia delivery and opportunities for resilient real-time decision support
Total intravenous anesthesia (TIVA) is a well-established technique for general anesthesia and is increasingly relevant to Europe’s transition toward more digital, sustainable, and patient-centred healthcare. However, its use remains uneven across centres and still depends heavily on population-based drug models, variable monitoring practices, and repeated clinician adjustment. Differences in training, data access, device compatibility, patient response, and institutional resources can limit safe and consistent personalization. In this Review, we examine the main sources of fragility in current TIVA practice and discuss how interoperable perioperative data, digital patient simulators, patient-adaptive models, multimodal monitoring, and closed-loop decision support could improve safety and resilience. We emphasize that these technologies should support, not replace, the anesthesiologist, and should remain transparent, clinically supervised, and easy to override. We conclude by outlining priorities for European collaboration in data infrastructure, training, validation, regulation, and evaluation of AI-enabled tools.
- 2 December 2025
- Published by Elsevier in Neurocomputing
- Vol. 666
Tuning of a predictive control scheme for intravenous anesthesia: influence on performance and computational requirements
- 2 December 2025
- Published by Elsevier in Neurocomputing
- Vol. 666
Tuning of a predictive control scheme for intravenous anesthesia: influence on performance and computational requirements
- Open Access
System Realizations by Mammillary Models with an Application to Propofol Pharmacokinetics
This work addresses the problem of linear system realizations by mammillary models, offering necessary and sufficient conditions under which a given transfer function can be represented in this form. While standard identifi cation techniques may yield transfer functions without an explicit connection to underlying physiological processes, com partmental models, particularly mammillary ones, reflect the physiological dynamics of distribution and elimination. This feature is especially relevant in clinical pharmacology, where model parameters must correspond to meaningful biological processes to support interpretability, personalization, and safe drug delivery, such as in total intravenous anesthesia. To conclude, an application to a propofol infusion model illustrates how mammillary realizations can support physiologically inter pretable system representations.
Open AccessSystem Realizations by Mammillary Models with an Application to Propofol Pharmacokinetics
This work addresses the problem of linear system realizations by mammillary models, offering necessary and sufficient conditions under which a given transfer function can be represented in this form. While standard identifi cation techniques may yield transfer functions without an explicit connection to underlying physiological processes, com partmental models, particularly mammillary ones, reflect the physiological dynamics of distribution and elimination. This feature is especially relevant in clinical pharmacology, where model parameters must correspond to meaningful biological processes to support interpretability, personalization, and safe drug delivery, such as in total intravenous anesthesia. To conclude, an application to a propofol infusion model illustrates how mammillary realizations can support physiologically inter pretable system representations.
- 17 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 33 (6) , 2208-2216
In Vivo Performance Evaluation of an FOPID Controller for Closed-Loop Anesthesia
In this article, we design and evaluate a fractional-order proportional-integral-derivative (FOPID) controller for the regulation of total intravenous anesthesia (TIVA). In particular, the FOPID controller has been designed to regulate the patient’s depth of hypnosis (DoH), measured via the bispectral index (BIS) monitor, by coadministrating both the hypnotic and analgesic drugs used in TIVA. Separate tunings are obtained for the induction phase and for the maintenance phase. For the former, a methodology based on the minimization of the integrated absolute error (IAE) has been employed, while for the latter, the isodamping design approach has been applied. Experiments carried out on ten patients undergoing plastic surgery show that the FOPID controller meets the clinical requirements for each one of the ten patients without requiring any manual intervention from the anesthesiologist. Notably, the controller provided a fast rejection of disturbances without provoking harmful overdosing episodes.
- 17 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 33 (6) , 2208-2216
In Vivo Performance Evaluation of an FOPID Controller for Closed-Loop Anesthesia
In this article, we design and evaluate a fractional-order proportional-integral-derivative (FOPID) controller for the regulation of total intravenous anesthesia (TIVA). In particular, the FOPID controller has been designed to regulate the patient’s depth of hypnosis (DoH), measured via the bispectral index (BIS) monitor, by coadministrating both the hypnotic and analgesic drugs used in TIVA. Separate tunings are obtained for the induction phase and for the maintenance phase. For the former, a methodology based on the minimization of the integrated absolute error (IAE) has been employed, while for the latter, the isodamping design approach has been applied. Experiments carried out on ten patients undergoing plastic surgery show that the FOPID controller meets the clinical requirements for each one of the ten patients without requiring any manual intervention from the anesthesiologist. Notably, the controller provided a fast rejection of disturbances without provoking harmful overdosing episodes.
- Open Access
- 3 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 9, 745-750
Optimized Feedforward Control for the Co-Administration of Propofol and Remifentanil for Induction of Hypnosis in General Anesthesia
General anesthesia is a crucial component of invasive medical procedures. Our primary focus is the optimization of the simultaneous infusion of propofol and remifentanil during induction. In particular, we compute a feedforward infusion rate that minimizes the time for bringing the Bispectral Index (BIS) value below an assigned threshold, while ensuring that the BIS remains above an assigned minimum value. We consider a two-drug model, that takes into account the synergistic effect of the two drugs. Due to the expression of the Hill function, the constraint of maintaining the BIS in a given interval is non-convex. We propose a convex tightening to formulate the overall optimal control task as a convex optimization problem. Through simulation experiments, we show that this hybrid feedforward-feedback strategy quickly achieves the BIS target, while maintaining safe and clinically acceptable infusion rates.
- 3 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 9, 745-750
Open AccessOptimized Feedforward Control for the Co-Administration of Propofol and Remifentanil for Induction of Hypnosis in General Anesthesia
General anesthesia is a crucial component of invasive medical procedures. Our primary focus is the optimization of the simultaneous infusion of propofol and remifentanil during induction. In particular, we compute a feedforward infusion rate that minimizes the time for bringing the Bispectral Index (BIS) value below an assigned threshold, while ensuring that the BIS remains above an assigned minimum value. We consider a two-drug model, that takes into account the synergistic effect of the two drugs. Due to the expression of the Hill function, the constraint of maintaining the BIS in a given interval is non-convex. We propose a convex tightening to formulate the overall optimal control task as a convex optimization problem. Through simulation experiments, we show that this hybrid feedforward-feedback strategy quickly achieves the BIS target, while maintaining safe and clinically acceptable infusion rates.
- Open Access
- 15 January 2025
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 104
Kalman filter soft sensor to handle signal quality loss in closed-loop controlled anesthesia
- 15 January 2025
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 104
Open AccessKalman filter soft sensor to handle signal quality loss in closed-loop controlled anesthesia
- 16 November 2024
- Published by Springer Nature
- p. 285-294
Tuning of a Predictive Control Scheme for Intravenous Anaesthesia Exploring Set of Fixed Ratios
- 16 November 2024
- Published by Springer Nature
- p. 285-294
Tuning of a Predictive Control Scheme for Intravenous Anaesthesia Exploring Set of Fixed Ratios
- Open Access
- 7 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 8, 1427-1432
Experimental Evaluation of Analgesia With an Event-Based PID Control Strategy for Anesthesia
The recent introduction of the Conox monitoring system in the clinical practice of total intravenous anesthesia (TIVA) has opened new research opportunities. Indeed, it provides the qCON and the qNOX indexes, which give a measure of hypnosis and analgesia, respectively. This paper presents the first experimental results of closed-loop anesthesia performed by using the Conox monitoring system. In particular, we exploited the qCON as the feedback variable for an event-based PID multiple-input single-output (MISO) controller and we recorded the qNOX to evaluate analgesia. Clinical experiments have been performed on four patients undergoing general anesthesia for elective plastic surgery. The controller demonstrated a satisfactory performance in maintaining qCON within the desired range for all patients. An optimal qNOX level has also been achieved in three out of four cases, while, in one patient, the qNOX level indicated a slight excess of analgesia. These findings suggest that the proposed MISO architecture is effective in providing adequate levels of hypnosis and analgesia and that, in future works, the qNOX information could be leveraged in the controller design to enhance analgesia control.
- 7 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 8, 1427-1432
Open AccessExperimental Evaluation of Analgesia With an Event-Based PID Control Strategy for Anesthesia
The recent introduction of the Conox monitoring system in the clinical practice of total intravenous anesthesia (TIVA) has opened new research opportunities. Indeed, it provides the qCON and the qNOX indexes, which give a measure of hypnosis and analgesia, respectively. This paper presents the first experimental results of closed-loop anesthesia performed by using the Conox monitoring system. In particular, we exploited the qCON as the feedback variable for an event-based PID multiple-input single-output (MISO) controller and we recorded the qNOX to evaluate analgesia. Clinical experiments have been performed on four patients undergoing general anesthesia for elective plastic surgery. The controller demonstrated a satisfactory performance in maintaining qCON within the desired range for all patients. An optimal qNOX level has also been achieved in three out of four cases, while, in one patient, the qNOX level indicated a slight excess of analgesia. These findings suggest that the proposed MISO architecture is effective in providing adequate levels of hypnosis and analgesia and that, in future works, the qNOX information could be leveraged in the controller design to enhance analgesia control.
- Open Access
- 9 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 8, 580-585
Human-Imitating Control of Depth of Hypnosis Combining MPC and Event-Based PID Strategies
In this paper we propose a human-imitating control methodology for the Depth-of-Hypnosys (DoH) in total intravenous anesthesia (TIVA) where the bispectral index (BIS) is used as process variable. The method suitably combines a move-blocking model predictive controller (MPC) that minimizes the time-to-target when the BIS value is not in the required range and an event-based Proportional-Integral-Derivative (PID) controller that provides a strong filtering action when the DoH is satisfactory. A fast induction is achieved and awareness episodes are avoided with a control action that is piecewise constant so that it mimics the behavior of the anesthesiologist and is more likely to be accepted in the clinical practice.
- 9 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 8, 580-585
Open AccessHuman-Imitating Control of Depth of Hypnosis Combining MPC and Event-Based PID Strategies
In this paper we propose a human-imitating control methodology for the Depth-of-Hypnosys (DoH) in total intravenous anesthesia (TIVA) where the bispectral index (BIS) is used as process variable. The method suitably combines a move-blocking model predictive controller (MPC) that minimizes the time-to-target when the BIS value is not in the required range and an event-based Proportional-Integral-Derivative (PID) controller that provides a strong filtering action when the DoH is satisfactory. A fast induction is achieved and awareness episodes are avoided with a control action that is piecewise constant so that it mimics the behavior of the anesthesiologist and is more likely to be accepted in the clinical practice.
- Open Access
- 21 June 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (13) , 7381
On the Use of FOPID Controllers for Maintenance Phase of General Anesthesia
This paper investigates the performance achievable with a fractional-order PID regulator controlling the Depth of Hypnosis (measured via the Bispectral Index Scale) through the administration of propofol during the maintenance phase of total intravenous anesthesia. In particular, two different methodologies were applied to tune the controller: in the first case, genetic algorithms (GAs) were used to minimize the integrated absolute error, while in the second case, the isodamping approach—a method that targets phase margin invariance with respect to the process dc gain—was employed. In both cases, the performance was extensively analyzed and compared with that of a standard PID controller by simulating multiple patients through a Monte Carlo method. The results demonstrate that a fractional-order PID controller can be effectively used to control the Depth of Hypnosis, but the improvement with respect to a standard PID controller is marginal.
- 21 June 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (13) , 7381
Open AccessOn the Use of FOPID Controllers for Maintenance Phase of General Anesthesia
This paper investigates the performance achievable with a fractional-order PID regulator controlling the Depth of Hypnosis (measured via the Bispectral Index Scale) through the administration of propofol during the maintenance phase of total intravenous anesthesia. In particular, two different methodologies were applied to tune the controller: in the first case, genetic algorithms (GAs) were used to minimize the integrated absolute error, while in the second case, the isodamping approach—a method that targets phase margin invariance with respect to the process dc gain—was employed. In both cases, the performance was extensively analyzed and compared with that of a standard PID controller by simulating multiple patients through a Monte Carlo method. The results demonstrate that a fractional-order PID controller can be effectively used to control the Depth of Hypnosis, but the improvement with respect to a standard PID controller is marginal.