SRShweta Ranjan

Shweta Ranjan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shweta Ranjan has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative Evaluation of Heat-Inactivated ABO Isoagglutinin Titers with Solid-Phase Red Cell Adhesion Titers

    by Shweta Ranjan, Prashant Pandey, Divya Setya, Supriya Kumari

    Background and Objectives: Measurement of actual concentration of IgG requires methods like heat inactivation (HI) of serum. This study was aimed at comparing of heat-treated ABO titers performed by conventional test tube technique (CTT) and column agglutination technique (CAT) with hemagglutination (HA)/solid-phase red cell adherence (SPRCA). Methods: This was a prospective, observational study conducted between October 2019 and March 2020. All consecutive A, B, and O group donors who gave consent for participation in the project were included. All samples were tested by CTT and CAT before and after HI (post DTT treatment performed by CTT [pCTT] and post DTT treatment performed by CAT [pCAT]) and with HA/SPRCA. Results: A total of 300 donors were included: 100 each with A, B, and O blood groups. For group O, IgG titers were higher than IgM titers among group O, whereas that among group A and group B, IgM titer was found to be higher than IgG titer by both HA/SPRCA and pCTT. The titer values among all the three blood groups were highest when the test was performed by pCAT, though the results of pCTT and SPRCA, pCTT, and pCAT were significant in group O donors. For groups A and B, results of pCTT and pCAT, pCAT, and HA/SPRCA were found to be statistically significant. Conclusion: Results obtained by HA/SPRCA were closer to pCTT, with respect to time consumption, expertise required, and lack of inter-observer variation. Titers obtained by pCAT were higher in comparison to pCTT obviously due to its relative higher sensitivity. Hence, these methods cannot be used interchangeably.

  • Comparative assessment of dithiothreitol‐treated ABO isoagglutinin titres performed by two methods

    by Prashant Pandey, Divya Setya, Shweta Ranjan, Mukesh Kumar Singh


  • A prospective, observational study to compare effect of DTT treatment and heat inactivation on ABO isoagglutinin titers in O blood group donors

    by Prashant Pandey, Divya Setya, Shweta Ranjan, Mukesh Kumar Singh

    Background and aims: In order to determine actual concentration of clinically significant IgG antibodies, there is a need to inactivate IgM antibodies, which can be performed by DTT or heat. The aim of the present study was to compare the effect of DTT treatment and heat inactivation (HI) on ABO isoagglutinin titres performed by column agglutination technology (CAT) and conventional tube technique (CTT).Materials and methods: This was a prospective, observational study conducted from October 2018 to March 2020. All consecutive O group donors were included. Serum from each donor was treated with DTT, and heat and tests were performed by CTT and CAT before and after treatment.Results: A total of 2005 donors were included. 401 (20%) samples had inter‐observer variation by CTT, and 69 (3·4%) had inter‐observer variation by CAT. Median anti‐A and anti‐B titre results were higher with CAT as compared to CTT. Median anti‐A and anti‐B IgG titre results showed a one‐ to twofold difference between CTT and CAT with higher titres reported by CAT. Median IgM titres decreased two‐ to threefold after DTT treatment, whereas onefold decrease was confirmed after HI. Concordance was found to be poor. However, correlation was found to be strong.Conclusion: There is overestimation of ABO IgG antibody titres and hence, estimation of ABO IgG titres after inactivation of IgM antibodies is strongly recommended. DTT treatment was found to be superior to HI in terms of efficiency in elimination of IgM activity.

  • Comparison of ABO isoagglutinin titres by three different methods in group O blood donors

    by Prashant Pandey, Divya Setya, Shweta Ranjan, Manish Kumar Singh

    Background and aims: Antibody titration by the manual method has certain limitations. The aim of this study was to compare the manual conventional test tube technique (CTT) with semi‐automated, column agglutination technique (CAT) and fully automated haemagglutination/solid‐phase red cell adherence (HA/SPRCA) technology in measuring antibody titres of anti‐A and anti‐B isoagglutinins of blood group O blood donors. The median IgM and IgG antibody titres with 1+, 2+ and 3+ end‐points were determined for each technology, and the agreement and correlation between results of the 3 technologies were evaluated.Materials and methods: This was a prospective, observational study conducted from October 2018 to March 2020. All consecutive O group blood donors, who donated blood at the Department of Transfusion Medicine at a tertiary healthcare centre, were included in the study. All samples were consecutively tested by CTT, CAT and HA/SPRCA, and the results were recorded and compared.Results: A total of 2005 donors were included. Inter‐observer variation was observed in 295 (14.71%) samples by the CTT and in 51 (2.54%) by the CAT. There was 43.4% and 40.3% agreement of anti‐A IgM and IgG titres between CAT (2+ strength) and CTT (1+ strength), respectively. The agreement for anti‐B IgM and IgG titres between CAT (2+ strength) and CTT (1+ strength) was 43.6% and 32%, respectively. While a strong correlation was found between CTT (1+ strength) and CAT (1+, 2+ strengths) for both IgM and IgG measurements of anti‐A and anti‐B isoagglutinins, the correlation between CTT (1+ strength) and HA/SPRCA (1+, 2+ strengths) was found to be weak. The median IgM titres for anti‐A and anti‐B were lower than the median IgG titres.Conclusion: The antibody titration levels were higher with CAT than with CTT, and those of HA/SPRCA were lower than those of CTT. Transfusion services need to decide which method would provide higher benefit to their patient population.


  • Survey to assess knowledge, attitude and practices for safe and efficient vein‐to‐vein transfusion practices and effect of educational intervention in a hospital setting

    by Prashant Pandey, Divya Setya, Arya Suresh, Geobin George, Chhavi Chaudhary, Praveen Kumar, Shweta Ranjan

    Objectives The primary aim was to assess the knowledge, attitude and practices (KAP) of employees (medical, paramedical and other hospital staff) towards blood donation and transfusion practices in a tertiary care hospital. A secondary objective was to assess and interpret the effect of an educational module on improvement in the KAP of employees in a hospital setting. Background For satisfactory practices, it is essential to initiate KAP studies. Methods/materials This was a prospective, observational study conducted among hospital staff (clinical and non‐clinical) from January to December 2019. The study was divided into two phases: pre‐educational module (P1) and post‐educational module (P2). In both phases, a questionnaire was distributed. Knowledge was assessed by 30 questions, attitude by 20 questions and practice by 30 questions. If any individual had unsatisfactory scores in both the P1 and P2 phases (scores P‐value < .05) was observed between P1 and P2 scores. Of 172 participants, 27 were asked to attend the 2‐week certificate course due to unsatisfactory scores (score < 40) in both P1 and P2 phases. These 27 participants required attending this certificate course a mean of 1.67 ± 0.83 times to obtain satisfactory scores. Conclusion Educational intervention is an important tool for improving KAP among not only physicians but hospital staff as well.