Zhuang Xiong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhuang Xiong has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Chao Zhi
Institute of Electronic Engineering, China Academy of Engineering Physics, Mianyang, People’s Republic of China
4 shared publications Fengtian Zhang
Institute of Electronic Engineering, China Academy of Engineering Physics, Mianyang, People’s Republic of China
4 shared publicationsBin Tang
Institute of Electronic Engineering, China Academy of Engineering Physics
3 shared publicationsMingshan Qu
Institute of Electronic Engineering, China Academy of Engineering Physics, Mianyang, China
3 shared publicationsYanjun Li
Institute of Electronic Engineering, China Academy of Engineering Physics, Mianyang, China
3 shared publications- Benjamin Walter
Institut d'Electronique, de Microélectronique et de Nanotechnologie—IEMN CNRS UMR8520, NAM6 group, Villeneuve d'Ascq 59650, France
2 shared publications
Latest Publications
- 1 May 2024
- Published by Springer Nature in Microsystem Technologies
- Vol. 30 (8) , 1039-1048
Design and analysis of micro inertial switch with magnetic latch and adjustable threshold
- 1 May 2024
- Published by Springer Nature in Microsystem Technologies
- Vol. 30 (8) , 1039-1048
Design and analysis of micro inertial switch with magnetic latch and adjustable threshold
- 15 November 2022
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 32 (12) , 125007
A long-stroke planar linear actuator equipped with magnetic guide
This paper introduces the design, fabrication and characterization of a micro electromagnetic linear actuator integrated with magnetic guide. The actuator consists of a slider, a stator and a magnetic guide. A magnetic guide is used to replace the mechanical rail of conventional linear actuator to ensure the linear motion and to avoid friction. The purpose of this paper is to study the influence of magnetic guide on the dynamic characteristics of electromagnetic linear actuator and measuring techniques for micro-actuators. To test the resistance to motion and output thrust force of the actuator, a cantilever type force sensor is proposed, which can measure the small force in ∼mN order, and the measurement error is less than 3%. Using this sensor, the output thrust measured is higher than 10 mN when 1 A current is applied, and the friction force of the actuator measured is about 7.73 mN. Two-phase square wave and sine wave current are used to drive the actuator, the minimum driving current and frequency of the actuator are less than 0.1 A and 1 Hz respectively. The actuator attains a maximum stable moving speed of 0.15 m s −1 with the input signal frequency of below 250 Hz. In addition, the anti-interference capability of the actuator is evaluated through simulations and experiments. These results show that the actuator can bear an interference 45 times its own gravity in the directions that are perpendicular to the moving freedom, and can adjust the direction of motion automatically when the rotation angle in three orthogonal directions is less than 6°.
- 15 November 2022
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 32 (12) , 125007
A long-stroke planar linear actuator equipped with magnetic guide
This paper introduces the design, fabrication and characterization of a micro electromagnetic linear actuator integrated with magnetic guide. The actuator consists of a slider, a stator and a magnetic guide. A magnetic guide is used to replace the mechanical rail of conventional linear actuator to ensure the linear motion and to avoid friction. The purpose of this paper is to study the influence of magnetic guide on the dynamic characteristics of electromagnetic linear actuator and measuring techniques for micro-actuators. To test the resistance to motion and output thrust force of the actuator, a cantilever type force sensor is proposed, which can measure the small force in ∼mN order, and the measurement error is less than 3%. Using this sensor, the output thrust measured is higher than 10 mN when 1 A current is applied, and the friction force of the actuator measured is about 7.73 mN. Two-phase square wave and sine wave current are used to drive the actuator, the minimum driving current and frequency of the actuator are less than 0.1 A and 1 Hz respectively. The actuator attains a maximum stable moving speed of 0.15 m s −1 with the input signal frequency of below 250 Hz. In addition, the anti-interference capability of the actuator is evaluated through simulations and experiments. These results show that the actuator can bear an interference 45 times its own gravity in the directions that are perpendicular to the moving freedom, and can adjust the direction of motion automatically when the rotation angle in three orthogonal directions is less than 6°.
- 14 February 2022
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 32 (3) , 035005
A bi-stable mechanism actuated by patterned permanent magnet and Cu-Ni integrated micro-coil
This paper presents a bi-stable mechanism, which mainly consists of a suspended mass, a spacer and a bottom plate. Electromagnetic actuation is used for switching between two states (i.e. ‘On/Off’ state). The actuation is achieved via permanent magnet (PM) on the suspended mass and micro-coils embedded in the bottom plate. Different from spiral coil and central core in conventional design, micro-coils in this paper integrate Cu and Ni together as a whole, acting as both coil and ferromagnetic core. This integration simplifies the fabrication into one-mask process. Furthermore, chessboard patterned PM is utilized with Cu-Ni integrated micro-coils to generate enhanced force density. The bi-stable mechanism is designed, fabricated and experimentally characterized. Total size of this mechanism is 16 × 14 × 2 mm 3 . No power is needed for holding either of the state. Switching processes (both ‘On’ to ‘Off’ and ‘Off’ to ‘On’) can be realized with external acceleration of 24 G (gravity) and 37 G, respectively. Furthermore, resetting (i.e. ‘On’ to ‘Off’) can also be accomplished with 1.5 A current input.
- 14 February 2022
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 32 (3) , 035005
A bi-stable mechanism actuated by patterned permanent magnet and Cu-Ni integrated micro-coil
This paper presents a bi-stable mechanism, which mainly consists of a suspended mass, a spacer and a bottom plate. Electromagnetic actuation is used for switching between two states (i.e. ‘On/Off’ state). The actuation is achieved via permanent magnet (PM) on the suspended mass and micro-coils embedded in the bottom plate. Different from spiral coil and central core in conventional design, micro-coils in this paper integrate Cu and Ni together as a whole, acting as both coil and ferromagnetic core. This integration simplifies the fabrication into one-mask process. Furthermore, chessboard patterned PM is utilized with Cu-Ni integrated micro-coils to generate enhanced force density. The bi-stable mechanism is designed, fabricated and experimentally characterized. Total size of this mechanism is 16 × 14 × 2 mm 3 . No power is needed for holding either of the state. Switching processes (both ‘On’ to ‘Off’ and ‘Off’ to ‘On’) can be realized with external acceleration of 24 G (gravity) and 37 G, respectively. Furthermore, resetting (i.e. ‘On’ to ‘Off’) can also be accomplished with 1.5 A current input.
- 26 November 2020
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 31 (1) , 015001
A self-attachable and self-alignable micro electromagnetic linear actuator
This paper presents the design, fabrication and characterization of a novel micro electromagnetic linear actuator, which exhibits two highlights: slider self-alignment and self-attachment capability. Such characters are realized by deliberately utilizing the attractive force between the permanent magnets (Nd 2 Fe 14 B) of the slider and nickel ferromagnetic cores embedded in the stator. Actuation is achieved via thrust from both meander micro copper coils and nickel ferromagnetic cores in the stator to the permanent magnets of the slider. The actuator is fabricated by the micro machining process. The surface magnetic property of the slider is simulated and experimentally measured. The eccentric experiment is conducted to evaluate the attraction force between the slider and stator, which proves its self-attachment characteristics. The device is actuated by two-phase sinusoidal currents with a 0.5 A amplitude under an open-loop condition. The slider demonstrates self-alignment movements before moving forward when misalignment occurs. The actuation experimental results show that the average velocity of the slider reaches 4 mm s –1 and 12 mm s –1 at 10 Hz and 30 Hz, respectively. Further increasing the input frequency to 50 Hz leads to the unsteady actuation state, indicating the actuator bandwidth is less than 50 Hz under an open-loop condition.
- 26 November 2020
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 31 (1) , 015001
A self-attachable and self-alignable micro electromagnetic linear actuator
This paper presents the design, fabrication and characterization of a novel micro electromagnetic linear actuator, which exhibits two highlights: slider self-alignment and self-attachment capability. Such characters are realized by deliberately utilizing the attractive force between the permanent magnets (Nd 2 Fe 14 B) of the slider and nickel ferromagnetic cores embedded in the stator. Actuation is achieved via thrust from both meander micro copper coils and nickel ferromagnetic cores in the stator to the permanent magnets of the slider. The actuator is fabricated by the micro machining process. The surface magnetic property of the slider is simulated and experimentally measured. The eccentric experiment is conducted to evaluate the attraction force between the slider and stator, which proves its self-attachment characteristics. The device is actuated by two-phase sinusoidal currents with a 0.5 A amplitude under an open-loop condition. The slider demonstrates self-alignment movements before moving forward when misalignment occurs. The actuation experimental results show that the average velocity of the slider reaches 4 mm s –1 and 12 mm s –1 at 10 Hz and 30 Hz, respectively. Further increasing the input frequency to 50 Hz leads to the unsteady actuation state, indicating the actuator bandwidth is less than 50 Hz under an open-loop condition.
- 27 October 2017
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 27 (12) , 125001
Conception, fabrication and characterization of a silicon based MEMS inertial switch with a threshold value of 5 g
Most of the MEMS inertial switches developed in recent years are intended for shock and impact sensing with a threshold value above 50 g. In order to follow the requirement of detecting linear acceleration signal at low- g level, a silicon based MEMS inertial switch with a threshold value of 5 g was designed, fabricated and characterized. The switch consisted of a large proof mass, supported by circular spiral springs. An analytical model of the structure stiffness of the proposed switch was derived and verified by finite-element simulation. The structure fabrication was based on a customized double-buried layer silicon-on-insulator wafer and encapsulated by glass wafers. The centrifugal experiment and nanoindentation experiment were performed to measure the threshold value as well as the structure stiffness. The actual threshold values were measured to be 0.1–0.3 g lower than the pre-designed value of 5 g due to the dimension loss during non-contact lithography processing. Concerning the reliability assessment, a series of environmental experiments were conducted and the switches remained operational without excessive errors. However, both the random vibration and the shock tests indicate that the metal particles generated during collision of contact parts might affect the contact reliability and long-time stability. According to the conclusion reached in this report, an attentive study on switch contact behavior should be included in future research.
- 27 October 2017
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 27 (12) , 125001
Conception, fabrication and characterization of a silicon based MEMS inertial switch with a threshold value of 5 g
Most of the MEMS inertial switches developed in recent years are intended for shock and impact sensing with a threshold value above 50 g. In order to follow the requirement of detecting linear acceleration signal at low- g level, a silicon based MEMS inertial switch with a threshold value of 5 g was designed, fabricated and characterized. The switch consisted of a large proof mass, supported by circular spiral springs. An analytical model of the structure stiffness of the proposed switch was derived and verified by finite-element simulation. The structure fabrication was based on a customized double-buried layer silicon-on-insulator wafer and encapsulated by glass wafers. The centrifugal experiment and nanoindentation experiment were performed to measure the threshold value as well as the structure stiffness. The actual threshold values were measured to be 0.1–0.3 g lower than the pre-designed value of 5 g due to the dimension loss during non-contact lithography processing. Concerning the reliability assessment, a series of environmental experiments were conducted and the switches remained operational without excessive errors. However, both the random vibration and the shock tests indicate that the metal particles generated during collision of contact parts might affect the contact reliability and long-time stability. According to the conclusion reached in this report, an attentive study on switch contact behavior should be included in future research.
- 8 June 2016
- Published by Springer Nature in Microsystem Technologies
- Vol. 23 (7) , 2467-2473
Fabrication of a silicon based vertical sensitive low-g inertial micro-switch for linear acceleration sensing
- 8 June 2016
- Published by Springer Nature in Microsystem Technologies
- Vol. 23 (7) , 2467-2473
Fabrication of a silicon based vertical sensitive low-g inertial micro-switch for linear acceleration sensing
- Open Access
- 1 July 2015
- Published by Institution of Engineering and Technology (IET) in Micro & Nano Letters
- Vol. 10 (7) , 347-350
Silicon‐based, low‐g microelectromechanical systems inertial switch for linear acceleration sensing application
Most of the microelectromechanical systems inertial switches developed in recent years are intended for shock and impact sensing above 40 g. These switches are fabricated based on non‐silicon surface micromachining with multiple steps of electroplating. In this reported work, a silicon‐based low‐g inertial switch typically used for linear acceleration sensing was conceived, designed and fabricated. The developed inertial switch consists of a high volume proof mass and low stiffness spiral spring, and is fabricated in a specially designed double‐buried layer silicon‐on‐insulator wafer, with standard silicon micromachining. The measurement results show that the threshold value is about 7.42 g and the stiffness is about 1.5 N/m, in accordance with the finite element method calculation.
- 1 July 2015
- Published by Institution of Engineering and Technology (IET) in Micro & Nano Letters
- Vol. 10 (7) , 347-350
Open AccessSilicon‐based, low‐g microelectromechanical systems inertial switch for linear acceleration sensing application
Most of the microelectromechanical systems inertial switches developed in recent years are intended for shock and impact sensing above 40 g. These switches are fabricated based on non‐silicon surface micromachining with multiple steps of electroplating. In this reported work, a silicon‐based low‐g inertial switch typically used for linear acceleration sensing was conceived, designed and fabricated. The developed inertial switch consists of a high volume proof mass and low stiffness spiral spring, and is fabricated in a specially designed double‐buried layer silicon‐on‐insulator wafer, with standard silicon micromachining. The measurement results show that the threshold value is about 7.42 g and the stiffness is about 1.5 N/m, in accordance with the finite element method calculation.
- Open Access
A Novel Dog-Bone Oscillating AFM Probe with Thermal Actuation and Piezoresistive Detection
In order to effectively increase the resonance frequency and the quality factor of atomic force microscope (AFM) probes, a novel oscillating probe based on a dog-bone shaped MEMS resonator was conceived, designed, fabricated and evaluated. The novel probe with 400 μm in length, 100 μm in width and 5 μm in thickness was enabled to feature MHz resonance frequencies with integrated thermal actuation and piezoresistive detection. Standard silicon micromachining was employed. Both electrical and optical measurements were carried out in air. The resonance frequency and the quality factor of the novel probe were measured to be 5.4 MHz and 4000 respectively, which are much higher than those (about several hundreds of kHz) of commonly used cantilever probes. The probe was mounted onto a commercial AFM set-up through a dedicated probe-holder and circuit board. Topographic images of patterned resist samples were obtained. It is expected that the resonance frequency and the measurement bandwidth of such probes will be further increased by a proper downscaling, thus leading to a significant increase in the scanning speed capability of AFM instruments.
Open AccessA Novel Dog-Bone Oscillating AFM Probe with Thermal Actuation and Piezoresistive Detection
In order to effectively increase the resonance frequency and the quality factor of atomic force microscope (AFM) probes, a novel oscillating probe based on a dog-bone shaped MEMS resonator was conceived, designed, fabricated and evaluated. The novel probe with 400 μm in length, 100 μm in width and 5 μm in thickness was enabled to feature MHz resonance frequencies with integrated thermal actuation and piezoresistive detection. Standard silicon micromachining was employed. Both electrical and optical measurements were carried out in air. The resonance frequency and the quality factor of the novel probe were measured to be 5.4 MHz and 4000 respectively, which are much higher than those (about several hundreds of kHz) of commonly used cantilever probes. The probe was mounted onto a commercial AFM set-up through a dedicated probe-holder and circuit board. Topographic images of patterned resist samples were obtained. It is expected that the resonance frequency and the measurement bandwidth of such probes will be further increased by a proper downscaling, thus leading to a significant increase in the scanning speed capability of AFM instruments.
- 1 January 2013
- Published by IGI Global Scientific Publishing in International Journal of Intelligent Mechatronics and Robotics
- Vol. 3 (1) , 38-52
Piezoresistive Ring-Shaped AFM Sensors with Pico-Newton Force Resolution
A new concept of Atomic Force Microscope (AFM) oscillating probes using electrostatic excitation and piezoresistive detection is presented. The probe is characterized by electrical methods in a vacuum chamber and by mechanical methods in air. The frequency-mixing measurement technique is developed to reduce the parasitic signal level. These probes resonant in the 1MHz range and the quality factor is measured about 53000 in vacuum and 3000 in air. The ring probe is mounted onto a commercial AFM set-up and the surface topography of PMMA sample (2 µm square) is obtained. The force resolution deduced from the measurements is about 10 pN/Hz0.5.
- 1 January 2013
- Published by IGI Global Scientific Publishing in International Journal of Intelligent Mechatronics and Robotics
- Vol. 3 (1) , 38-52
Piezoresistive Ring-Shaped AFM Sensors with Pico-Newton Force Resolution
A new concept of Atomic Force Microscope (AFM) oscillating probes using electrostatic excitation and piezoresistive detection is presented. The probe is characterized by electrical methods in a vacuum chamber and by mechanical methods in air. The frequency-mixing measurement technique is developed to reduce the parasitic signal level. These probes resonant in the 1MHz range and the quality factor is measured about 53000 in vacuum and 3000 in air. The ring probe is mounted onto a commercial AFM set-up and the surface topography of PMMA sample (2 µm square) is obtained. The force resolution deduced from the measurements is about 10 pN/Hz0.5.