Mahmut Parmaksiz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mahmut Parmaksiz has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Yaşar Murat Elçin
Ankara University
15 shared publications Ayşe Eser Elçin
8 shared publicationsArin Dogan
Ankara University Faculty of Science, and Ankara University Stem Cell Institute, Tissue Engineering, Biomaterials and Nanobiotechnology Laboratory, Ankara, Turkey
4 shared publicationsAyse Eser Elcin
Stem Cell Institute, Ankara University, Ankara, Turkey
3 shared publications- Klara Dalva
Ankara University
2 shared publications Murat Taner Vurat
2 shared publications
Latest Publications
- Open Access
- 31 August 2021
- Published by International Journal of 3D Printing Technologies and Digital Industry in International Journal of 3D Printing Technologies and Digital Industry
- Vol. 5 (2) , 251-258
MECHANICAL EVALUATION OF 3D PRINTED POLYCAPROLACTONE SCAFFOLDS: EFFECT OF MOLECULAR WEIGHT
Three-dimensional (3D) scaffold fabrication with appropriate architectural and mechanical properties is one of the critical components of tissue engineering. There are many traditional/conventional scaffold fabrication techniques such as electrospinning, gas foaming, freeze-drying etc. More recently, there has been increasing interest in the use of 3D printing technologies in scaffold fabrication for tissue engineering application. With the use of 3D printing technology, scaffolds with desired porosity and target damage/tissue architecture can be developed. Various 3D printing based scaffold production studies by using different types of synthetic or natural polymers are available in the literature. In the selection of polymers to be used for printing, parameters such as target scaffold mechanical properties, porosity and solubility should be considered. For example, it is well known that the molecular weights of the polymers can significantly affect the final scaffold mechanical properties. In this study, the effects of molecular weight and nozzle moving speed on the mechanical and physical properties of 3D printed scaffolds were evaluated. For this purpose, biocompatible PCL polymer with different molecular weights was used and ten-layered scaffolds were fabricated at different nozzle speeds. Then, mechanical, morphological and physical properties of the printed scaffolds were analyzed.
- 31 August 2021
- Published by International Journal of 3D Printing Technologies and Digital Industry in International Journal of 3D Printing Technologies and Digital Industry
- Vol. 5 (2) , 251-258
Open AccessMECHANICAL EVALUATION OF 3D PRINTED POLYCAPROLACTONE SCAFFOLDS: EFFECT OF MOLECULAR WEIGHT
Three-dimensional (3D) scaffold fabrication with appropriate architectural and mechanical properties is one of the critical components of tissue engineering. There are many traditional/conventional scaffold fabrication techniques such as electrospinning, gas foaming, freeze-drying etc. More recently, there has been increasing interest in the use of 3D printing technologies in scaffold fabrication for tissue engineering application. With the use of 3D printing technology, scaffolds with desired porosity and target damage/tissue architecture can be developed. Various 3D printing based scaffold production studies by using different types of synthetic or natural polymers are available in the literature. In the selection of polymers to be used for printing, parameters such as target scaffold mechanical properties, porosity and solubility should be considered. For example, it is well known that the molecular weights of the polymers can significantly affect the final scaffold mechanical properties. In this study, the effects of molecular weight and nozzle moving speed on the mechanical and physical properties of 3D printed scaffolds were evaluated. For this purpose, biocompatible PCL polymer with different molecular weights was used and ten-layered scaffolds were fabricated at different nozzle speeds. Then, mechanical, morphological and physical properties of the printed scaffolds were analyzed.
- 30 June 2021
- Published by Hitit University in Hittite Journal of Science and Engineering
- Vol. 8 (2) , 171-177
Development of a nanofibrous scaffold based on bovine tissue-derived ECM and Poly(ε-caprolactone) for tissue engineering applications
In this study, nanofibrous biohybrid scaffolds were developed by electrospinning using poly(ε-caprolactone) (PCL) and decellularized bovine tissue derived extracellular matrix (ECM). At the first part of the study, bovine ECM was decellularized by treatment with detergent for 24h and then combined with PCL. Following the evaluation of the decellularization efficiency via spectrophotometric DNA content analysis, the composite scaffolds were characterized by using SEM and FT-IR spectroscopy. Moreover, to assess the biocompatibility of the scaffolds an in vitro cell culture based cytotoxicity test was performed. The results indicated that, DNA content of the bovine tissue was reduced by ~80% compared to the native tissue after decellularization. While FT-IR results indicated the presence of ECM in the composite scaffolds, SEM findings showed that the porous nanofibrous structure of the scaffold changed depending on the incorporated ECM amount. Cell culture based studies also revealed that, the scaffolds containing different amounts of ECM did not have any toxic effect on cell viability during 48 hours of culture period.
- 30 June 2021
- Published by Hitit University in Hittite Journal of Science and Engineering
- Vol. 8 (2) , 171-177
Development of a nanofibrous scaffold based on bovine tissue-derived ECM and Poly(ε-caprolactone) for tissue engineering applications
In this study, nanofibrous biohybrid scaffolds were developed by electrospinning using poly(ε-caprolactone) (PCL) and decellularized bovine tissue derived extracellular matrix (ECM). At the first part of the study, bovine ECM was decellularized by treatment with detergent for 24h and then combined with PCL. Following the evaluation of the decellularization efficiency via spectrophotometric DNA content analysis, the composite scaffolds were characterized by using SEM and FT-IR spectroscopy. Moreover, to assess the biocompatibility of the scaffolds an in vitro cell culture based cytotoxicity test was performed. The results indicated that, DNA content of the bovine tissue was reduced by ~80% compared to the native tissue after decellularization. While FT-IR results indicated the presence of ECM in the composite scaffolds, SEM findings showed that the porous nanofibrous structure of the scaffold changed depending on the incorporated ECM amount. Cell culture based studies also revealed that, the scaffolds containing different amounts of ECM did not have any toxic effect on cell viability during 48 hours of culture period.
- Open Access
- 28 November 2020
- Published by Elsevier in Genes & Diseases
- Vol. 9 (4) , 1008-1023
Development of a multicellular 3D-bioprinted microtissue model of human periodontal ligament-alveolar bone biointerface: Towards a pre-clinical model of periodontal diseases and personalized periodontal tissue engineering
- 28 November 2020
- Published by Elsevier in Genes & Diseases
- Vol. 9 (4) , 1008-1023
Open AccessDevelopment of a multicellular 3D-bioprinted microtissue model of human periodontal ligament-alveolar bone biointerface: Towards a pre-clinical model of periodontal diseases and personalized periodontal tissue engineering
- 13 March 2020
- Published by Springer Nature in Stem Cell Reviews and Reports
- Vol. 16 (3) , 569-584
Decellularized Cell Culture ECMs Act as Cell Differentiation Inducers
Decellularized tissues and organs have aroused considerable interest for developing functional bio-scaffolds as natural templates in tissue engineering applications. More recently, the use of natural extracellular matrix (ECM) extracted from the in vitro cell cultures for cellular applications have come into question. It is well known that the microenvironment largely defines cellular properties. Thus, we have anticipated that the ECMs of the cells with different potency levels should likely possess different effects on cell cultures. To test this, we have comparatively evaluated the differentiative effects of ECMs derived from the cultures of human somatic dermal fibroblasts, human multipotent bone marrow mesenchymal stem cells, and human induced pluripotent stem cells on somatic dermal fibroblasts. Although challenges remain, the data suggest that the use of cell culture-based extracellular matrices perhaps may be considered as an alternative approach for the differentiation of even somatic cells into other cell types.
- 13 March 2020
- Published by Springer Nature in Stem Cell Reviews and Reports
- Vol. 16 (3) , 569-584
Decellularized Cell Culture ECMs Act as Cell Differentiation Inducers
Decellularized tissues and organs have aroused considerable interest for developing functional bio-scaffolds as natural templates in tissue engineering applications. More recently, the use of natural extracellular matrix (ECM) extracted from the in vitro cell cultures for cellular applications have come into question. It is well known that the microenvironment largely defines cellular properties. Thus, we have anticipated that the ECMs of the cells with different potency levels should likely possess different effects on cell cultures. To test this, we have comparatively evaluated the differentiative effects of ECMs derived from the cultures of human somatic dermal fibroblasts, human multipotent bone marrow mesenchymal stem cells, and human induced pluripotent stem cells on somatic dermal fibroblasts. Although challenges remain, the data suggest that the use of cell culture-based extracellular matrices perhaps may be considered as an alternative approach for the differentiation of even somatic cells into other cell types.
- 1 January 2020
- Published by Elsevier
- p. 219-250
Clinical and surgical aspects of medical materials’ biocompatibility
- 1 January 2020
- Published by Elsevier
- p. 219-250
Clinical and surgical aspects of medical materials’ biocompatibility
- 29 July 2019
- Published by S. Karger AG in Cells Tissues Organs
- Vol. 207 (1) , 15-20
A CD34+ Cell Enrichment Protocol of Hematopoietic Stem Cells in a Well-Established Quality Management System
Allogeneic stem cell transplantation applications have improved tremendously over the past quarter of a century. The use of new immunosuppressive protocols and elimination of T cells by CD34+ cell enrichment or T cell depletion on apheresis products increases the chance of using partially matched or haploidentical grafts. This is without increasing the risk of graft-versus-host disease, which is observed as a major complication of hematopoietic stem cell transplantation. The aim of this protocol is to evaluate the results obtained from 6 different process cycles performed on 6 different days. We used the CliniMACS Plus system located in our Cell and Tissue Manufacturing Center Quality Control Unit which is already calibrated as a class D room and includes a class A microbiological safety cabinet inside. The average purity of the end products was 95.66%, excluding only one end product which was 70%; this was higher than the values in current studies in the field. Superior to the reported studies, the CD3 quantity in each end product was below the dedicated thresholds. BactecTM FX40 blood culture system test results were detected as negative for each end product. Endotoxin testing suggested the absence of endotoxin within the products. The consistent outcomes obtained from these 6 different process cycles confirmed that the CliniMACS® Plus process cycles performed in accordance with our well-defined quality management system procedure is sufficient for the routine application of high-quality and safe CD34+ enrichment processes within our clean room area.
- 29 July 2019
- Published by S. Karger AG in Cells Tissues Organs
- Vol. 207 (1) , 15-20
A CD34+ Cell Enrichment Protocol of Hematopoietic Stem Cells in a Well-Established Quality Management System
Allogeneic stem cell transplantation applications have improved tremendously over the past quarter of a century. The use of new immunosuppressive protocols and elimination of T cells by CD34+ cell enrichment or T cell depletion on apheresis products increases the chance of using partially matched or haploidentical grafts. This is without increasing the risk of graft-versus-host disease, which is observed as a major complication of hematopoietic stem cell transplantation. The aim of this protocol is to evaluate the results obtained from 6 different process cycles performed on 6 different days. We used the CliniMACS Plus system located in our Cell and Tissue Manufacturing Center Quality Control Unit which is already calibrated as a class D room and includes a class A microbiological safety cabinet inside. The average purity of the end products was 95.66%, excluding only one end product which was 70%; this was higher than the values in current studies in the field. Superior to the reported studies, the CD3 quantity in each end product was below the dedicated thresholds. BactecTM FX40 blood culture system test results were detected as negative for each end product. Endotoxin testing suggested the absence of endotoxin within the products. The consistent outcomes obtained from these 6 different process cycles confirmed that the CliniMACS® Plus process cycles performed in accordance with our well-defined quality management system procedure is sufficient for the routine application of high-quality and safe CD34+ enrichment processes within our clean room area.
- 1 January 2019
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 94, 788-797
Decellularized bovine small intestinal submucosa-PCL/hydroxyapatite-based multilayer composite scaffold for hard tissue repair
- 1 January 2019
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 94, 788-797
Decellularized bovine small intestinal submucosa-PCL/hydroxyapatite-based multilayer composite scaffold for hard tissue repair