Stig Geving
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stig Geving has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Bjørn Petter Jelle
2 shared publicationsJonas Holme
SINTEF Building and Infrastructure, Trondheim NO-7465, Norway
2 shared publicationsAnna Fedorova
1 shared publication- Anna Fedorova
Norwegian University of Science and Technology (NTNU), Department of Civil and Environmental Engineering, NO-7491 Trondheim, Norway
1 shared publication Bozena Dorota Hrynyszyn
1 shared publication- Bozena Dorota Hrynyszyn
Department of Civil and Environmental Engineering, Norwegian University of Science and Technology, 7491 Trondheim, Norway
1 shared publication
Latest Publications
- Open Access
- 1 December 2021
- Published by Elsevier in Solar Energy
- Vol. 230, 376-389
Quantification of wind-driven rain intrusion in building-integrated photovoltaic systems
- 1 December 2021
- Published by Elsevier in Solar Energy
- Vol. 230, 376-389
Open AccessQuantification of wind-driven rain intrusion in building-integrated photovoltaic systems
- Open Access
- 1 July 2021
- Published by Elsevier in Building and Environment
- Vol. 199
A testing methodology for quantification of wind-driven rain intrusion for building-integrated photovoltaic systems
- 1 July 2021
- Published by Elsevier in Building and Environment
- Vol. 199
Open AccessA testing methodology for quantification of wind-driven rain intrusion for building-integrated photovoltaic systems
- Open Access
- 1 May 2021
- Published by Elsevier in Building and Environment
- Vol. 195
Effect of forced convection on the hygrothermal performance of a wood frame wall with wood fibre insulation
- 1 May 2021
- Published by Elsevier in Building and Environment
- Vol. 195
Open AccessEffect of forced convection on the hygrothermal performance of a wood frame wall with wood fibre insulation
- Open Access
- 1 January 2021
- Published by Elsevier in Building and Environment
- Vol. 188
Moisture performance of interior insulated brick wall segments subjected to wetting and drying – A laboratory investigation
- 1 January 2021
- Published by Elsevier in Building and Environment
- Vol. 188
Open AccessMoisture performance of interior insulated brick wall segments subjected to wetting and drying – A laboratory investigation
- Open Access
- 6 September 2019
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 282, 02009
Compact wooden roofs with smart vapour barriers – effect of wooden joists on drying of built-in moisture
The application of a smart vapour barrier in compact wood frame roofs has been investigated. The study was performed using a laboratory setup for small roof elements, exposed to a typical Nordic summer climate and a high level of built-in moisture. The concept of this study was to investigate how various types of wooden joists and their hygroscopic properties influenced the inward drying and moisture distribution within the elements. The results were compared to previous studies with similar roof elements without wooden joists. The results showed that the type and size of wooden joist influenced both the drying speed and the moisture level and distribution within the elements.
- 6 September 2019
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 282, 02009
Open AccessCompact wooden roofs with smart vapour barriers – effect of wooden joists on drying of built-in moisture
The application of a smart vapour barrier in compact wood frame roofs has been investigated. The study was performed using a laboratory setup for small roof elements, exposed to a typical Nordic summer climate and a high level of built-in moisture. The concept of this study was to investigate how various types of wooden joists and their hygroscopic properties influenced the inward drying and moisture distribution within the elements. The results were compared to previous studies with similar roof elements without wooden joists. The results showed that the type and size of wooden joist influenced both the drying speed and the moisture level and distribution within the elements.
- Open Access
- 17 April 2019
- Published by Kaunas University of Technology (KTU) in Journal of Sustainable Architecture and Civil Engineering
- Vol. 24 (1) , 44-51
The Effect of Repeated Moisture Cycles on the Air Tightness of Traditional Clamped Vapour Barrier Joints
In this study it has been investigated whether and to what extent, repeated moisture cycles affect the airleakage through clamped overlap joints in the vapour barrier layer. Use of clamped joints is a traditionalway to make airtight joints in the wind- and vapour barrier used in wood frame walls in Norway and othercountries. A laboratory test has been carried out, with a total of 63 pressure tests, being carried out on 9 testsamples, consisting of overlap joints of 0.15 mm polyethylene film clamped between a wooden batten andstud. Each sample was tested seven times after repeated drying and humidification, where the moisturevalues of the sub-cycles were chosen to represent the annual variations of indoor relative humidity.The laboratory test materials were mounted with machine nails with various center spacing (150 mm,300 mm and 450 mm). The overlap joints of the vapour barrier were in the end of the test sealed withadhesive tape, revealing to what extent this over a longer period of time will be beneficial.The results showed that the first moisture cycle (drying) resulted in significant increase of air leakage forall the sample variants. Throughout the moisture cycles, a further strong leakage development for centerspacing 450 mm was observed, which was less for 300 mm, and non-existent for 150 mm. The gain ofusing structural adhesive tape was found to largely depend on the level of perforation resulting from thenails and their center distance. Adhesive tape on the joints resulted in the greatest reduction in leakagenumbers where the center distance between the nails was high, i.e. the reduction was 58% for centerdistance 450 mm. However, with shorter center distance the use of tape only decreased the air leakagebetween 22-39%, revealing the fact that a large part of the joint leakage is through the nail perforations.
- 17 April 2019
- Published by Kaunas University of Technology (KTU) in Journal of Sustainable Architecture and Civil Engineering
- Vol. 24 (1) , 44-51
Open AccessThe Effect of Repeated Moisture Cycles on the Air Tightness of Traditional Clamped Vapour Barrier Joints
In this study it has been investigated whether and to what extent, repeated moisture cycles affect the airleakage through clamped overlap joints in the vapour barrier layer. Use of clamped joints is a traditionalway to make airtight joints in the wind- and vapour barrier used in wood frame walls in Norway and othercountries. A laboratory test has been carried out, with a total of 63 pressure tests, being carried out on 9 testsamples, consisting of overlap joints of 0.15 mm polyethylene film clamped between a wooden batten andstud. Each sample was tested seven times after repeated drying and humidification, where the moisturevalues of the sub-cycles were chosen to represent the annual variations of indoor relative humidity.The laboratory test materials were mounted with machine nails with various center spacing (150 mm,300 mm and 450 mm). The overlap joints of the vapour barrier were in the end of the test sealed withadhesive tape, revealing to what extent this over a longer period of time will be beneficial.The results showed that the first moisture cycle (drying) resulted in significant increase of air leakage forall the sample variants. Throughout the moisture cycles, a further strong leakage development for centerspacing 450 mm was observed, which was less for 300 mm, and non-existent for 150 mm. The gain ofusing structural adhesive tape was found to largely depend on the level of perforation resulting from thenails and their center distance. Adhesive tape on the joints resulted in the greatest reduction in leakagenumbers where the center distance between the nails was high, i.e. the reduction was 58% for centerdistance 450 mm. However, with shorter center distance the use of tape only decreased the air leakagebetween 22-39%, revealing the fact that a large part of the joint leakage is through the nail perforations.
- 11 March 2015
- Published by Springer Nature in Rock Mechanics and Rock Engineering
- Vol. 49 (1) , 243-272
Moisture Transport Through Sprayed Concrete Tunnel Linings
- 11 March 2015
- Published by Springer Nature in Rock Mechanics and Rock Engineering
- Vol. 49 (1) , 243-272
Moisture Transport Through Sprayed Concrete Tunnel Linings
- Open Access
- 20 February 2013
- Published by Elsevier in Frontiers of Architectural Research
- Vol. 2 (1) , 42-49
Vapour retarders in wood frame walls and their effect on the drying capability
- 20 February 2013
- Published by Elsevier in Frontiers of Architectural Research
- Vol. 2 (1) , 42-49
Open AccessVapour retarders in wood frame walls and their effect on the drying capability
- 19 October 2011
- Published by SAGE Publications in Journal of Building Physics
- Vol. 35 (4) , 392-421
Mean and diurnal indoor air humidity loads in residential buildings
In this study, indoor air humidity and temperature levels have been measured in 117 houses in Trondheim, Norway. The houses were randomly selected for each of the following types: detached one-family houses, semidetached two-family houses, row houses, and apartment buildings. The temperature and relative humidity (RH) were measured at 15-min interval over a period of 1 week. The measurements were made in bedrooms, living rooms, bathrooms, and outdoors. The internal moisture excess, which is the difference between indoor and outdoor air water vapour content, was calculated. The dataset was analysed in regard to average values of internal moisture excess and its dependency of outdoor climate. The daily variations of indoor RH, temperature, and internal moisture excess for the various types of rooms were also analysed. The typical diurnal variations of RH, temperature, and internal moisture excess are presented together with the statistical variation. The effect of influencing factors such as occupancy (area per person), type of basic ventilation of the house, type of building, time of the year, and the level of average indoor air humidity was investigated. To get a deeper understanding of some of the factors influencing the diurnal variations of the indoor air humidity observed in the field measurements, computer simulations of the indoor air humidity were also performed. The simulations were made using the numerical software WUFI Plus.
- 19 October 2011
- Published by SAGE Publications in Journal of Building Physics
- Vol. 35 (4) , 392-421
Mean and diurnal indoor air humidity loads in residential buildings
In this study, indoor air humidity and temperature levels have been measured in 117 houses in Trondheim, Norway. The houses were randomly selected for each of the following types: detached one-family houses, semidetached two-family houses, row houses, and apartment buildings. The temperature and relative humidity (RH) were measured at 15-min interval over a period of 1 week. The measurements were made in bedrooms, living rooms, bathrooms, and outdoors. The internal moisture excess, which is the difference between indoor and outdoor air water vapour content, was calculated. The dataset was analysed in regard to average values of internal moisture excess and its dependency of outdoor climate. The daily variations of indoor RH, temperature, and internal moisture excess for the various types of rooms were also analysed. The typical diurnal variations of RH, temperature, and internal moisture excess are presented together with the statistical variation. The effect of influencing factors such as occupancy (area per person), type of basic ventilation of the house, type of building, time of the year, and the level of average indoor air humidity was investigated. To get a deeper understanding of some of the factors influencing the diurnal variations of the indoor air humidity observed in the field measurements, computer simulations of the indoor air humidity were also performed. The simulations were made using the numerical software WUFI Plus.