ESElisama Sutil

Elisama Sutil

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Elisama Sutil has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Does localized irradiance of poly-wave LED influence the bonding performance of universal adhesives to dentin?

    by E Sutil, M Wendlinger, Afm Cardenas, Fsf de Siqueira, Cj Soares, S Geraldeli, Ad Loguercio


  • An experimental bleaching gel containing a nanocomposite reduces the intensity of postoperative tooth sensitivity: A randomized, triple blind clinical trial

    by Karine Letícia da Silva, Fernanda Novak Gumy, Elisama Sutil, Byron Carpio-Salvatierra, Maria Cristina Rockenbach-Binz, Alessandra Reis, Alessandro D․ Loguercio, Paulo Vitor Farago


  • Different daily times for at-home bleaching with 10% carbamide peroxide

    by Renata Maria Oleniki Terra, Elisama Sutil, Deisy Cristina Ferreira Cordeiro, Michael Willian Favoreto, André Faria-E-Silva, Al M. Best, Alessandro D. Loguercio, Alessandra Reis


  • Open Access

    In-office dental bleaching in adolescents using 6% hydrogen peroxide with and without gingival barrier: a randomized double-blind clinical trial

    by Taynara de Souza Carneiro, Michael Willian Favoreto, João Pedro Ferreira Rodrigues, Elisama Sutil, Gabrielle Gomes Centenaro, Isabela de Matos de Freitas, Alessandra Reis, Laura Ceballos García, Alessandro Dourado Loguercio

    At low concentrations used for in-office bleaching gels, such as 6% HP, gingival barrier continues to be performed. If we take into account that, in the at-home bleaching technique, no barrier is indicated, it seems that the use of a gingival barrier fails to make much sense when bleaching gel in low concentration is used for in-office bleaching.


  • Open Access

    Coadministration of ibuprofen/caffeine on bleaching-induced tooth sensitivity: A randomized clinical trial

    by Karine Letícia da Silva, Elisama Sutil, Diego Hortkoff, Renata Maria Oleniki Terra, Márcia Rezende, Alessandra Reis, Alessandro D. Loguercio, Ana Paula Vilela, Paulo Vitor Farago

    This clinical trial evaluated the effect of the coadministration of ibuprofen/caffeine on bleaching-induced tooth sensitivity (TS). A triple-blind, parallel-design, randomized clinical trial was conducted on 84 patients who received ibuprofen/caffeine or placebo capsules. The drugs were administered for 48 hours, starting 1 hour before the in-office bleaching. Two bleaching sessions were performed with 35% hydrogen peroxide gel with 1-week interval. TS was recorded up to 48 hours after dental bleaching with a 0-10 visual analogic scale (VAS) and a 5-point numeric rating scale (NRS). The color was evaluated with VITA Classical and VITA Bleachedguide scales (ΔSGU) and VITA Easyshade spectrophotometer (ΔE*ab and ΔE00). The absolute risk of TS in both groups was evaluated using Fischer's exact test. Comparisons of the TS intensity (NRS and VAS data) were performed by using the Mann-Whitney test and a two-way repeated measures ANOVA, respectively. The color alteration between the groups was compared with the Student's t test. The significance level was 5%. There was no statistically significant difference between the groups for the absolute risk of TS (p = 1.00) or for the intensity of TS (p > 0.05). A bleaching of approximately 7 shade guide units was observed on the Vita Classical and Vita Bleachedguide scales, with no statistical difference between the groups. It was concluded that coadministration of ibuprofen and caffeine did not reduce the absolute risk or intensity of TS and did not interfere with the efficacy of dental bleaching.


  • Open Access

    Universal adhesives and dual-cured core buildup composite material: adhesive properties

    by Pâmela Malaquias, Mario Felipe Gutiérrez, Elisama Sutil, Thalita de Paris Matos, Taise Alessandra Hanzen, Alessandra Reis, Jorge Perdigão, Alessandro Dourado Loguercio

    Dual-cured buildup composites and simplified light-cured adhesive systems are mixed with a chemical activator to prevent the incompatibility between them. Objective: To evaluate microshear bond strength (μSBS) and nanoleakage (NL) of three universal adhesives used under buildup composites using different curing modes, at baseline and after 6-months (6m). Methodology: Dentin specimens of 55 molars were assigned to: Clearfil Universal Bond[CFU], Prime&Bond Elect[PBE] and One Coat 7 Universal[OCU]. All-Bond Universal[ABU] and Adper Scotchbond Multi-Purpose[SMP] were used as controls. CFU, PBE, and OCU were: light-cured [LC], dual-cured using a self-curing activator [DC], and self-cured, using a self-curing activator and waiting for 20 min [SC]. Upon the application of the adhesive, transparent matrices were filled with a dual-cured buildup composite and light cured, then tested in mSBS. For NL, the specimens were submersed in ammoniacal silver nitrate and sectioned to observe under the SEM. Three-way ANOVA and Tukey's test were applied (α=0.05). Results: OCU/LC-PBE/LC resulted in higher mean μSBS than ABU/LC. For SMP/DC higher mean μSBS were obtained than for both CFU/DC and OCU/DC (baseline). No universal adhesive was significantly affected by curing mode or storage time. CFU, PBE, and OCU did not undergo significant changes in any curing mode (p>0.05). NL (baseline) PBE/LC resulted in higher %NL compared to ABU/LC. SMP/DC resulted in higher %NL than CFU/DC-OCU/DC. CFU/LC/DC resulted in lower %NL than CFU/SC. PBE/SC resulted in lower %NL than PBE/DC. OCU/LC/SC showed lower %NL than OCU/DC. OCU showed significant lower %NL than CFU and PBE. All CFU groups, as well as OCU/SC, resulted in increased %NL at 6m when compared with baseline. Conclusion: For universal adhesives used in etch-and-rinse mode, self-cured activator and different curing modes did not influence μSBS. However, some interactions were observed for NL, but this influence was material-specific.


  • EDTA Conditioning Increases the Long-term Microtensile Bond Strength to Sclerotic Dentin Mediated by Self-etch Adhesives

    by Issis Virginia Luque-Martinez, Miguel Angel Munoz, Viviane Hass, Elisama Sutil, Alessandra Reis, Alessandro D. Loguercio

    Purpose: To evaluate the immediate and 12-month microtensile bond strength (mu TBS) of two self-etch adhesives on sclerotic dentin with or without previous EDTA conditioning. The conditioning pattern and the relative area of open dentinal tubules were also evaluated. Materials and Methods: Twenty-eight bovine incisors with naturally exposed sclerotic dentin were used. For mu TBS testing, 20 teeth were divided into 4 groups (n = 5) according to the combination of the main factors: 1. adhesive (Clearfil SE Bond [CSE, Kuraray] and Adper SE Plus [ADSE, 3M Oral Care]); 2. surface treatment (previous conditioning with EDTA and previous conditioning with distilled water [DW]). The sclerotic surfaces were conditioned with either 17% EDTA or DW for 2 min prior to adhesive application. Composite buildups were constructed. Specimens were sectioned to obtain composite-dentin sticks (0.8 mm(2)) to be tested immediately or after 12 months (distilled water at 37 degrees C) in tensile mode (0.5 mm/min). The conditioning pattern and the relative area of open dentinal tubules (OT) were evaluated in the remaining eight teeth. After adhesive application, the surfaces were rinsed off with acetone and ethanol. Then the surface was evaluated by SEM with image software. Data from mu TBS and OT were submitted to three-way repeated measures ANOVA and data from OT were submitted to one-way repeated measures ANOVA. After, for both tests, Tukey's post-hoc test was applied (alpha = 0.05). Results: For both adhesives, EDTA resulted in the highest mean immediate mu TBS (p = 0.002), which remained stable after 12 months of water storage (p < 0.38). CSE showed higher mu TBS when compared to ADSE (p = 0.001). Degradation of the mean mu TBS was observed for both adhesives only in the DW groups. Adhesive application plus with EDTA conditioning increased the OT area in comparison with only adhesive application (p < 0.001). Conclusion: EDTA conditioning increased the immediate microtensile bond strength in sclerotic dentin substrate and prevented degradation when associated with a self-etch adhesive.


  • Effect of self-curing activators and curing protocols on adhesive properties of universal adhesives bonded to dual-cured composites

    by Mario Felipe Gutiérrez, Elisama Sutil, Pâmela Malaquias, Thalita de Paris Matos, Lucas Marques de Souza, Alessandra Reis, Jorge Perdigão, Alessandro D. Loguercio