Trang Huynh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Trang Huynh has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Barry N. Noller
BCentre for Mine Land Rehabilitation Sustainable Minerals Institute, The University of Queensland, Brisbane, Qld 4072, Australia
2 shared publications - Hugh Hamlyn Harris
Discipline of Chemistry, The University of Adelaide, North Terrace, Adelaide, SA 5005, Australia
2 shared publications Barry Noller
1 shared publication- Hao Zhang
School of Public Health, Shandong Second Medical University, Weifang, China
1 shared publication Hugh Harris
1 shared publication- Ian R. Gentle
Centre for Organic Photonics & Electronics School of Chemistry and Molecular Biosciences The University of Queensland Brisbane QLD 4072 Australia
1 shared publication
Latest Publications
- 1 March 2021
- Published by Elsevier in The Extractive Industries and Society
- Vol. 8 (1) , 123-134
How the population in Mount Isa is living with lead exposure from mining activities
- 1 March 2021
- Published by Elsevier in The Extractive Industries and Society
- Vol. 8 (1) , 123-134
How the population in Mount Isa is living with lead exposure from mining activities
- 17 February 2015
- Published by CSIRO Publishing in Environmental Chemistry
- Vol. 12 (2) , 102-111
Measurement of labile arsenic speciation in water and soil using diffusive gradients in thin films (DGT) and X-ray absorption near edge spectroscopy (XANES)
Environmental context: Both inorganic and organic arsenic species are toxic to the environment when labile. The Diffusive Gradients in Thin Films technique, equipped with ferrihydrite binding gel enables measurement of labile arsenic species from water and soil solutions. This study indicated that labile arsenic species are quantitatively adsorbed to the gel, and that they are stable for up to 2 weeks following deployment. Arsenic speciation was determined in the solution extracted from a ferrihydrite binding gel layer in a DGT unit (FB-DGT) deployed in water using coupled high-performance liquid chromatography and hydride generation atomic fluorescence spectrometry (HPLC-HG-AFS). However, the extent of change in arsenic speciation during the extraction process is unknown. By identifying the arsenic species in the FB-DGT gel directly, using X-ray absorption near edge spectroscopy (XANES) fitting with model arsenic compounds, we obtain a better understanding of the ability of FB-DGT to measure labile arsenic species in solution. The results presented herein confirm that FB-DGT accumulated labile inorganic and methylated arsenic species. Arsenic species bound to the FB-DGT gel were stable for up to 2 weeks following deployment. However, caution should be applied when interpreting the proportion of As species measured by HPLC-HG-AFS in solution extracted from FB-DGT because the distribution of arsenic species in extracted solutions was found to be modified by the extraction process. Some (~20 %) of arsenate was converted into arsenite, and a significant amount (~25 %) of dimethylarsinic acid (DMAsV) was converted into monomethylarsonic acid (MMAsV) or arsenate (AsV). Only inorganic arsenite (iAsIII) was stable during the extraction process. These findings suggested that, based on the XANES measurement, although As species were quantitatively accumulated in the FB-DGT gel, the FB-DGT technique was still unsuitable for studying As speciation. This is because changes in arsenic speciation were observed to occur during gel extraction, prior to HPLC-HG-AFS measurement, and because the XANES technique is available for routine measurements.
- 17 February 2015
- Published by CSIRO Publishing in Environmental Chemistry
- Vol. 12 (2) , 102-111
Measurement of labile arsenic speciation in water and soil using diffusive gradients in thin films (DGT) and X-ray absorption near edge spectroscopy (XANES)
Environmental context: Both inorganic and organic arsenic species are toxic to the environment when labile. The Diffusive Gradients in Thin Films technique, equipped with ferrihydrite binding gel enables measurement of labile arsenic species from water and soil solutions. This study indicated that labile arsenic species are quantitatively adsorbed to the gel, and that they are stable for up to 2 weeks following deployment. Arsenic speciation was determined in the solution extracted from a ferrihydrite binding gel layer in a DGT unit (FB-DGT) deployed in water using coupled high-performance liquid chromatography and hydride generation atomic fluorescence spectrometry (HPLC-HG-AFS). However, the extent of change in arsenic speciation during the extraction process is unknown. By identifying the arsenic species in the FB-DGT gel directly, using X-ray absorption near edge spectroscopy (XANES) fitting with model arsenic compounds, we obtain a better understanding of the ability of FB-DGT to measure labile arsenic species in solution. The results presented herein confirm that FB-DGT accumulated labile inorganic and methylated arsenic species. Arsenic species bound to the FB-DGT gel were stable for up to 2 weeks following deployment. However, caution should be applied when interpreting the proportion of As species measured by HPLC-HG-AFS in solution extracted from FB-DGT because the distribution of arsenic species in extracted solutions was found to be modified by the extraction process. Some (~20 %) of arsenate was converted into arsenite, and a significant amount (~25 %) of dimethylarsinic acid (DMAsV) was converted into monomethylarsonic acid (MMAsV) or arsenate (AsV). Only inorganic arsenite (iAsIII) was stable during the extraction process. These findings suggested that, based on the XANES measurement, although As species were quantitatively accumulated in the FB-DGT gel, the FB-DGT technique was still unsuitable for studying As speciation. This is because changes in arsenic speciation were observed to occur during gel extraction, prior to HPLC-HG-AFS measurement, and because the XANES technique is available for routine measurements.
- 6 July 2010
- Published by AIP Publishing
- Vol. 1234 (1) , 621-624
Decision Process for Comparison of Partial and Complete XANES Spectra
If the range of XANES spectra varies between sets of scans, it may be impossible to compare sets of spectra unless a restricted part of the spectra is used. The paper derives a decision process for comparison of partial and complete XANES spectra, taking lead as an example. Lead L3‐edge XANES spectra were collected at the Australian National Beamline Facility (BL‐20B) Photon Factory, Tsukuba, Japan over the energy range 13,000–13,150 eV (ring conditions: 2.5 GeV, 300–400 mA). The monochromator step size was reduced to 0.25 eV per step in the XANES region (13,000–13,100 eV and 13,040–13,100 eV) to collect high‐resolution spectra. XANES data for samples and model compounds were collected at ambient temperature and pressure in fluorescence, using simultaneous collection of a Pb metal reference foil for energy calibration (first derivative peak of elemental Pb was 13,050 eV). XANES spectra were fitted using spectral deconvolution and least‐squares linear combination fitting (LCF). Detailed XANES results with LCF approach over various energy ranges are illustrated and discussed and show the applicability of the decision‐making procedure to compare sets of spectra.
- 6 July 2010
- Published by AIP Publishing
- Vol. 1234 (1) , 621-624
Decision Process for Comparison of Partial and Complete XANES Spectra
If the range of XANES spectra varies between sets of scans, it may be impossible to compare sets of spectra unless a restricted part of the spectra is used. The paper derives a decision process for comparison of partial and complete XANES spectra, taking lead as an example. Lead L3‐edge XANES spectra were collected at the Australian National Beamline Facility (BL‐20B) Photon Factory, Tsukuba, Japan over the energy range 13,000–13,150 eV (ring conditions: 2.5 GeV, 300–400 mA). The monochromator step size was reduced to 0.25 eV per step in the XANES region (13,000–13,100 eV and 13,040–13,100 eV) to collect high‐resolution spectra. XANES data for samples and model compounds were collected at ambient temperature and pressure in fluorescence, using simultaneous collection of a Pb metal reference foil for energy calibration (first derivative peak of elemental Pb was 13,050 eV). XANES spectra were fitted using spectral deconvolution and least‐squares linear combination fitting (LCF). Detailed XANES results with LCF approach over various energy ranges are illustrated and discussed and show the applicability of the decision‐making procedure to compare sets of spectra.