Anna Shabalina
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Anna Shabalina has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Vadim Agafonov
Moscow Institute of Physics and Technology, 141700 Dolgoprudny, Russia
3 shared publications - Dmitry Zaitsev
Moscow Institute of Physics and Technology
2 shared publications - A. Glandon
Old Dominion University
1 shared publication Adam Carpenter
Jefferson Laboratory, Newport News, Virginia 23606, USA
1 shared publicationAlexander Antonov
Center for Molecular Electronics, Moscow Institute of Physics and Technology, Moscow 117303, Russia
1 shared publication- Alexander V. Neeshpapa
Moscow Institute of Physics and Technology, 9, Institutsky lane, 141700 Dolgoprudny, Russia
1 shared publication
Latest Publications
- 26 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Networks and Learning Systems
- Vol. 33 (11) , 6215-6225
Deep Cellular Recurrent Network for Efficient Analysis of Time-Series Data With Spatial Information
Efficient processing of large-scale time-series data is an intricate problem in machine learning. Conventional sensor signal processing pipelines with hand-engineered feature extraction often involve huge computational costs with high dimensional data. Deep recurrent neural networks have shown promise in automated feature learning for improved time-series processing. However, generic deep recurrent models grow in scale and depth with the increased complexity of the data. This is particularly challenging in presence of high dimensional data with temporal and spatial characteristics. Consequently, this work proposes a novel deep cellular recurrent neural network (DCRNN) architecture to efficiently process complex multidimensional time-series data with spatial information. The cellular recurrent architecture in the proposed model allows for location-aware synchronous processing of time-series data from spatially distributed sensor signal sources. Extensive trainable parameter sharing due to cellularity in the proposed architecture ensures efficiency in the use of recurrent processing units with high-dimensional inputs. This study also investigates the versatility of the proposed DCRNN model for the classification of multiclass time-series data from different application domains. Consequently, the proposed DCRNN architecture is evaluated using two time-series data sets: a multichannel scalp electroencephalogram (EEG) data set for seizure detection, and a machine fault detection data set obtained in-house. The results suggest that the proposed architecture achieves state-of-the-art performance while utilizing substantially less trainable parameters when compared to comparable methods in the literature.
- 26 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Networks and Learning Systems
- Vol. 33 (11) , 6215-6225
Deep Cellular Recurrent Network for Efficient Analysis of Time-Series Data With Spatial Information
Efficient processing of large-scale time-series data is an intricate problem in machine learning. Conventional sensor signal processing pipelines with hand-engineered feature extraction often involve huge computational costs with high dimensional data. Deep recurrent neural networks have shown promise in automated feature learning for improved time-series processing. However, generic deep recurrent models grow in scale and depth with the increased complexity of the data. This is particularly challenging in presence of high dimensional data with temporal and spatial characteristics. Consequently, this work proposes a novel deep cellular recurrent neural network (DCRNN) architecture to efficiently process complex multidimensional time-series data with spatial information. The cellular recurrent architecture in the proposed model allows for location-aware synchronous processing of time-series data from spatially distributed sensor signal sources. Extensive trainable parameter sharing due to cellularity in the proposed architecture ensures efficiency in the use of recurrent processing units with high-dimensional inputs. This study also investigates the versatility of the proposed DCRNN model for the classification of multiclass time-series data from different application domains. Consequently, the proposed DCRNN architecture is evaluated using two time-series data sets: a multichannel scalp electroencephalogram (EEG) data set for seizure detection, and a machine fault detection data set obtained in-house. The results suggest that the proposed architecture achieves state-of-the-art performance while utilizing substantially less trainable parameters when compared to comparable methods in the literature.
- Open Access
- 30 November 2020
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 23 (11) , 114601
Superconducting radio-frequency cavity fault classification using machine learning at Jefferson Laboratory
We report on the development of machine learning models for classifying C100 superconducting radio-frequency (SRF) cavity faults in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. CEBAF is a continuous-wave recirculating linac utilizing 418 SRF cavities to accelerate electrons up to 12 GeV through five passes. Of these, 96 cavities (12 cryomodules) are designed with a digital low-level rf system configured such that a cavity fault triggers waveform recordings of 17 rf signals for each of the eight cavities in the cryomodule. Subject matter experts are able to analyze the collected time-series data and identify which of the eight cavities faulted first and classify the type of fault. This information is used to find trends and strategically deploy mitigations to problematic cryomodules. However, manually labeling the data is laborious and time consuming. By leveraging machine learning, near real-time—rather than postmortem—identification of the offending cavity and classification of the fault type has been implemented. We discuss performance of the machine learning models during a recent physics run. Results show the cavity identification and fault classification models have accuracies of 84.9% and 78.2%, respectively.
- 30 November 2020
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 23 (11) , 114601
Open AccessSuperconducting radio-frequency cavity fault classification using machine learning at Jefferson Laboratory
We report on the development of machine learning models for classifying C100 superconducting radio-frequency (SRF) cavity faults in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. CEBAF is a continuous-wave recirculating linac utilizing 418 SRF cavities to accelerate electrons up to 12 GeV through five passes. Of these, 96 cavities (12 cryomodules) are designed with a digital low-level rf system configured such that a cavity fault triggers waveform recordings of 17 rf signals for each of the eight cavities in the cryomodule. Subject matter experts are able to analyze the collected time-series data and identify which of the eight cavities faulted first and classify the type of fault. This information is used to find trends and strategically deploy mitigations to problematic cryomodules. However, manually labeling the data is laborious and time consuming. By leveraging machine learning, near real-time—rather than postmortem—identification of the offending cavity and classification of the fault type has been implemented. We discuss performance of the machine learning models during a recent physics run. Results show the cavity identification and fault classification models have accuracies of 84.9% and 78.2%, respectively.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 287-292
High resolution miniature MET sensors for healthcare and sport applications
A device has been developed for determining the motion parameters of the human body and lower limbs intended for use in orthopedic healthcare facilities, treatment and prevention of musculoskeletal system disorders, sports medicine. The layout of a miniature detector of movement parameters, consisting of six miniatures high precision molecular-electronic technology (MET) sensors (three linear motion sensors and three angular motion sensors) designed to be fixed on human lower limbs and body, was developed and constructed. Data processing algorithms have been developed to define, in addition to the provided instrumentally accurate data on linear and angular motion parameters at sensor fixation points, the major phases of motion corresponding to the periods of rest, start and end of the motion, as well as the actual movements of human limbs and body.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 287-292
High resolution miniature MET sensors for healthcare and sport applications
A device has been developed for determining the motion parameters of the human body and lower limbs intended for use in orthopedic healthcare facilities, treatment and prevention of musculoskeletal system disorders, sports medicine. The layout of a miniature detector of movement parameters, consisting of six miniatures high precision molecular-electronic technology (MET) sensors (three linear motion sensors and three angular motion sensors) designed to be fixed on human lower limbs and body, was developed and constructed. Data processing algorithms have been developed to define, in addition to the provided instrumentally accurate data on linear and angular motion parameters at sensor fixation points, the major phases of motion corresponding to the periods of rest, start and end of the motion, as well as the actual movements of human limbs and body.
- Open Access
Molecular Electronic Angular Motion Transducer Broad Band Self-Noise
Modern molecular electronic transfer (MET) angular motion sensors combine high technical characteristics with low cost. Self-noise is one of the key characteristics which determine applications for MET sensors. However, until the present there has not been a model describing the sensor noise in the complete operating frequency range. The present work reports the results of an experimental study of the self-noise level of such sensors in the frequency range of 0.01–200 Hz. Based on the experimental data, a theoretical model is developed. According to the model, self-noise is conditioned by thermal hydrodynamic fluctuations of the operating fluid flow in the frequency range of 0.01–2 Hz. At the frequency range of 2–100 Hz, the noise power spectral density has a specific inversely proportional dependence of the power spectral density on the frequency that could be attributed to convective processes. In the high frequency range of 100–200 Hz, the noise is conditioned by the voltage noise of the electronics module input stage operational amplifiers and is heavily reliant to the sensor electrical impedance. The presented results allow a deeper understanding of the molecular electronic sensor noise nature to suggest the ways to reduce it.
Open AccessMolecular Electronic Angular Motion Transducer Broad Band Self-Noise
Modern molecular electronic transfer (MET) angular motion sensors combine high technical characteristics with low cost. Self-noise is one of the key characteristics which determine applications for MET sensors. However, until the present there has not been a model describing the sensor noise in the complete operating frequency range. The present work reports the results of an experimental study of the self-noise level of such sensors in the frequency range of 0.01–200 Hz. Based on the experimental data, a theoretical model is developed. According to the model, self-noise is conditioned by thermal hydrodynamic fluctuations of the operating fluid flow in the frequency range of 0.01–2 Hz. At the frequency range of 2–100 Hz, the noise power spectral density has a specific inversely proportional dependence of the power spectral density on the frequency that could be attributed to convective processes. In the high frequency range of 100–200 Hz, the noise is conditioned by the voltage noise of the electronics module input stage operational amplifiers and is heavily reliant to the sensor electrical impedance. The presented results allow a deeper understanding of the molecular electronic sensor noise nature to suggest the ways to reduce it.
- 9 February 2015
- Published by Springer Nature
- p. 1-19
Electrochemical Seismometers of Linear and Angular Motion
- 9 February 2015
- Published by Springer Nature
- p. 1-19
Electrochemical Seismometers of Linear and Angular Motion
- 1 January 2014
- Published by Allerton Press in Seismic Instruments
- Vol. 50 (1) , 1-8
Operating principles and technical characteristics of a small-sized molecular-electronic seismic sensor with negative feedback
The results of analysis of the output parameters of small-sized seismic motion sensors based on molecular electronics are presented. These devices feature a molecular-electronic transducer with negative feedback the introduction of which makes it possible to improve the sensor performance (specifically, to broaden the frequency range, reduce the amplitude-frequency characteristic (AFC) unevenness, and reduce the nonlinear distortion factor (NDF) value). The operating principle of these devices is outlined. The basic characteristics such as AFC, NDF, and the inherent noise level are determined experimentally, and the methods of their determination are described. The obtained data are analyzed and compared to the data on similar foreign devices. Principal lines of further research aimed not only at improving the technical characteristics but also at establishing a serial production process are specified.
- 1 January 2014
- Published by Allerton Press in Seismic Instruments
- Vol. 50 (1) , 1-8
Operating principles and technical characteristics of a small-sized molecular-electronic seismic sensor with negative feedback
The results of analysis of the output parameters of small-sized seismic motion sensors based on molecular electronics are presented. These devices feature a molecular-electronic transducer with negative feedback the introduction of which makes it possible to improve the sensor performance (specifically, to broaden the frequency range, reduce the amplitude-frequency characteristic (AFC) unevenness, and reduce the nonlinear distortion factor (NDF) value). The operating principle of these devices is outlined. The basic characteristics such as AFC, NDF, and the inherent noise level are determined experimentally, and the methods of their determination are described. The obtained data are analyzed and compared to the data on similar foreign devices. Principal lines of further research aimed not only at improving the technical characteristics but also at establishing a serial production process are specified.