BBBenjamin Bockmann

Benjamin Bockmann

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Benjamin Bockmann has a total of 45 co-authors. Here are the top co-authors by number of shared publications:

  • Arne Johannes Venjakob

    <!--9--> Department of Sports Orthopaedics St. Vinzenz Hospital Düsseldorf Germany

    9 shared publications
  • Wolfgang Nebelung

    <!--3--> OPND Praxisklinik Düsseldorf Germany

    9 shared publications
  • Frank Reichwein

    Marienkrankenhaus Dusseldorf Kaiserswerth, Dept Rheumatol & Arthroscopy, St Swidbert 17, Dusseldorf, Germany

    4 shared publications
  • Marthe Hagenacker

    Marienkrankenhaus Dusseldorf Kaiserswerth, Dept Rheumatol & Arthroscopy, St Swidbert 17, Dusseldorf, Germany

    4 shared publications
  • Dominik Seybold

    OPND-Praxisklinik, Plange Mühle 4, Düsseldorf, 40221, Germany

    3 shared publications
  • Tobias Ludger Schulte

    Department of Orthopaedics and Trauma Surgery, St. Josef Hospital, Ruhr University Bochum, Gudrunstraße 56, 44791, Bochum, Germany

    3 shared publications

Latest Publications

  • The arthroscopic treatment of anterior shoulder instability with glenoid bone loss shows similar clinical results after Latarjet procedure and iliac crest autograft transfer

    by Benjamin Bockmann, Wolfgang Nebelung, Falk Gröger, Jan Leuzinger, Jens Agneskirchner, Ulrich Brunner, Dominik Seybold, Jörg Streich, Stefan Bartsch, Katharina Schicktanz, et al.

    Purpose: Recurrent anterior shoulder instability caused by critical bone loss of the glenoid is a challenging condition for shoulder surgeons. The purpose of this prospective multicenter trial was to compare the arthroscopic transfer of the coracoid process (Latarjet procedure) with the arthroscopic reconstruction of the glenoid using iliac crest autografts. Methods: A prospective multi‐center trial was performed in nine orthopaedic centres in Austria, Germany and Switzerland between July 2015 and August 2021. Patients were prospectively enrolled and received either an arthroscopic Latarjet procedure or an arthroscopic iliac crest graft transfer. Standardized follow‐up after 6 months and mimimum 24 months included range of motion, Western Ontario stability index (WOSI), Rowe score and subjective shoulder value (SSV). All complications were recorded. Results: 177 patients (group Latarjet procedure: n = 110, group iliac crest graft: n = 67) were included in the study. WOSI (n.s.), SSV (n.s.) and Rowe score (n.s.) showed no difference at final follow‐up. 10 complications were seen in group Latarjet procedure and 5 in group iliac crest graft; the frequency of complications did not differ between the two groups (n.s.).Conclusion: The arthrosopic Latarjet procedure and arthroscopic iliac crest graft transfer lead to comparable results regarding clinical scores, frequency of recurrent dislocations and complication rates.Level of evidence: Level II.


  • Open Access

    Bone tunnel placement influences shear stresses at the coracoid process after coracoclavicular ligament reconstruction: a finite element study and radiological analysis

    by Benjamin Bockmann, L. Dankl, G. Kucinskaite, A. Kumar, J. J. Timothy, G. Meschke, A. J. Venjakob, T. L. Schulte

    Introduction: Coracoid fractures after arthroscopic treatment of acromioclavicular (AC) joint separations lead to poor clinical outcomes. In this study, different configurations of bone tunnels in the lateral clavicle and coracoid were examined concerning the amount of stress induced in the coracoid. Methods: An authentic 3D finite element model of an ac joint was established. Three 2.4 mm bone tunnels were inserted in the lateral clavicle, which were situated above, medially and laterally of the coracoid. Then, two 2.4 mm bone tunnels were inserted in the latter, each simulating a proximal and a distal suture button position. Von Mises stress analyses were performed to evaluate the amount of stress caused in the coracoid process by the different configurations. Then, a clinical series of radiographs was examined, the placement of the clavicle drill hole was analyzed and the number of dangerous configurations was recorded. Results: The safest configuration was a proximal tunnel in the coracoid combined with a lateral bone tunnel in the clavicle, leading to an oblique traction at the coracoid. A distal bone tunnel in the coracoid and perpendicular traction as well as a proximal tunnel in the coracoid with medial traction caused the highest stresses. Anatomical placement of the clavicle drill hole does lead to configurations with smaller stresses. Conclusion: The bone tunnel placement with the smallest amount of shear stresses was found when the traction of the suture button was directed slightly lateral, towards the AC joint. Anatomical placement of the clavicle drill hole alone was not sufficient in preventing dangerous configurations. Level of evidence: Controlled laboratory study.


  • Open Access

    Sonographic Measurement of Dynamic Horizontal Instability in Acromioclavicular Joint Instability

    by Benjamin Bockmann, Arne Johannes Venjakob, Giorgos Thrasyvoulidis, Malte Holschen, Tobias Ludger Schulte, Wolfgang Nebelung

    Objective: Dynamic horizontal instability is considered to be the main reason for poor outcome after treatment for acromioclavicular (AC) joint instability. In this study, we describe a simple technique to quantify this pathology via sonography.Methods: Thirty‐six shoulders from 18 patients with ac joint instabilities were examined using modified Alexander views and a standardized sonographic examination. On the Alexander views, overlap of acromion and clavicle (OLAC), glenoid center to posterior clavicle distance (GCPC), and lateral extension (LE) were measured. Afterwards, the results were analyzed and compared with sonography. Posterior translation of the clavicle and the difference of translation between healthy and injured shoulder were evaluated.Results: The mean age of the patients was 39 ± 14 years (range 19–61 years). We included 4 (22%) Rockwood type 3, 1 (6%) Rockwood type 4, and 13 (72%) Rockwood type 5 lesions. Four (22%) patients were female and 14 (78%) male patients. Posterior clavicle translation of the injured shoulder correlated strongly between OLAC and sonography (r = −0.514, P = .029), and the difference of translation between healthy and injured shoulder correlated very strongly between LE and sonography (r = 0.737, P < .001).Conclusion: The sonographic measurement technique for horizontal instability presented in this work could help detect horizontal instabilities. While the observation of dynamic horizontal displacement is a strength of this technique, measurements are hindered in cases of high coracoclavicular distances.Level of Evidence: Level III—retrospective cohort study.


  • Open Access

    Elective shoulder surgery during the coronavirus disease 2019 pandemic in Germany: the patients' perspective

    by Benjamin Bockmann, Arne Johannes Venjakob, Malte Holschen, Wolfgang Nebelung, Tobias Ludger Schulte


  • Open Access

    A biomechanical comparison of steel screws versus PLLA and magnesium screws for the Latarjet procedure

    by Benjamin Bockmann, E. Jaeger, L. Dankl, W. Nebelung, S. Frey, W. Schmölz, T. L. Schulte

    Introduction: The fixation of the coracoid process onto the glenoid is an important step of the Latarjet procedure, and implant-associated complications are a relevant and severe problem. This study compares the fixation strength and failure mode of two biodegradable materials with stainless-steel screws. Methods: 24 Fresh-frozen cadaveric scapulae were divided into three groups of equal size and received a coracoid transfer. Cadavers were matched according to their bone mineral density (BMD). In group 1, small-fragment screws made of stainless steel were used. In the second group, magnesium screws were used, and in the third group, screws consisted of polylactic acid (PLLA). A continuously increasing sinusoidal cyclic compression force was applied until failure occurred, which was defined as graft displacement relative to its initial position of more than 5 mm. Results: At 5-mm displacement, the axial force values showed a mean of 374 ± 92 N (range 219–479 N) in group 1 (steel). The force values in group 2 (magnesium) had a mean of 299 ± 57 N (range 190–357 N). In group 3 (PLLA), failure occurred at 231 ± 83 N (range 109–355 N). The difference between group 1 (steel) and group 2 (magnesium) was not statistically significant (P = 0.212), while the difference between group 1 (steel) and group 3 (PLLA) was significant (P = 0.005). Conclusion: Stainless-Steel screws showed the highest stability. However, all three screw types showed axial force values of more than 200 N. Stainless steel screws and PLLA screws showed screw cut-out as the most common failure mode, while magnesium screws showed screw breakage in the majority of cases. Evidence: Controlled laboratory study.


  • Open Access

    Planning Results for High Tibial Osteotomies in Degenerative Varus Osteoarthritis Using Standing and Supine Whole Leg Radiographs

    by Benjamin Bockmann, Wolfgang Nebelung, Christoph K Boese, Tobias L Schulte, Arne J Venjakob

    Objective: In this study, we hypothesized that standing and supine X‐rays lead to different preoperative planning results.Methods: The present study included 168 pictures from 81 patients who were treated surgically with high tibial osteotomy (HTO) for varus deformity between January 2017 and February 2018. Each patient underwent whole leg X‐ray examinations in both standing and supine position. On both images, the following parameters were measured: degree of axis deviation (DAD), mechanical lateral distal femoral angle (mLDFA), mechanical medial proximal tibial angle (mMPTA), width of medial (MJS) and lateral joint space (LJS), and the correction angle (CA). The results were correlated with the patients’ age and body mass index (BMI). To analyze intra‐observer reliability, the same researcher, blinded to the previous measurements, remeasured all X‐rays from 10 patients 8 weeks after the initial measurements were carried out.Results: While mLDFA (P = 0.075), mMPTA (P = 0.435), and MJS (P = 0.119) did not show any differences between the two modalities, LJS (P = 0.016) and DAD (P < 0.001) differed significantly, leading to different correction angles (P < 0.001). The mean difference of the CA was 1.7° ± 2.2° (range, −2.6° to−15.4°). In 14 legs (17%), the standing X‐ray led to a correction angle that was at least 3° larger than the calculation revealed in the supine X‐ray; in 4 legs (5%), it was at least 5° larger. Increased BMI (r = 0.191, P = 0.088) and older age (r = 0.057 , P = 0.605) did not show relevant correlation with DAD differences. However, more severe varus malalignment in the supine radiograph did correlate moderately with differences of correction angles between supine and weight‐bearing radiographs (r = 0.414, P < 0.001). The analysis of the intra‐rater reliability revealed mediocre to excellent intercorrelation coefficients between the measurements of the observer.Conclusion: The use of supine and standing X‐ray images leads to different planning results when performing high tibial osteotomies for varus gonarthrosis. To avoid potential overcorrection, surgeons might consider increased lateral joint spaces on standing radiographs in osteoarthritic knees with varus deviation.


  • Pullout strength and failure mode of industrially manufactured and self-made all-suture anchors: a biomechanical analysis

    by Holger Godry, Birger Jettkant, Dominik Seybold, Arne Johannes Venjakob, Benjamin Bockmann


  • Open Access

    Cement augmentation of an angular stable plate osteosynthesis for supracondylar femoral fractures - biomechanical investigation of a new fixation device

    by Martin Bäumlein, Antonio Klasan, Christine Klötzer, Benjamin Bockmann, Daphne Eschbach, Matthias Knobe, Benjamin Bücking, Steffen Ruchholtz, Christopher Bliemel

    Background: Implant anchorage in highly osteoporotic bone is challenging, since it often leads to osteosynthesis failure in geriatric patients with supracondylar femoral fractures. Cementation of screws is presumed to prevent such osteosynthesis failure. This study aimed to investigate the effect of a newly designed, cementable fenestrated condylar screw for plate fixation in a biomechanical setting. Methods: Eight pairs of osteoporotic cadaver femora with an average age of 77 years, ranging between 62 and 88 years, were randomly assigned to either an augmented or a non-augmented group. In both groups an instable 33-A3 fracture according to the AO / OTA classification was fixed with an angular stable locking plate. All right samples received a cement augmentation of their fenestrated condylar screws with calcium phosphate bone cement (CPC). Mechanical testing was performed at a load to failure mode by cyclic axial loading, using a servohydraulic testing machine. Results: With a mean of 2475 N (95% CI: 1727–3223 N), the pressure forces resulting in osteosynthesis failure were significantly higher in specimen with cemented condylar screws as compared to non-cemented samples (1875 N (95% CI: 1320–2430 N)) (p = 0.024). In both groups the deformation of the constructs, with the distal screws cutting through the condylar bone, were the most frequent cause for failure. Analysis of axial stiffness (p = 0.889) and irreversible deformity of the specimens revealed no differences between the both groups (p = 0.161). No cement leakage through the joint line or the medial cortex was observed. Conclusion: Based on the present study results, the newly introduced, cementable condylar screw could be an encouraging feature for the fixation of supracondylar femoral fractures in patients with reduced bone quality in terms of load to failure accuracy of the cement application.


  • All-arthroscopic glenoid reconstruction by iliac crest bone graft transfer does not affect structural integrity and 3-dimensional volume of the subscapularis muscle

    by Benjamin Bockmann, Arne Johannes Venjakob, Rolf Gebing, Wolfgang Nebelung

    Aim The subscapularis muscle is an important active stabilizer of the glenohumeral joint. For this radiological study, we investigated if its radiological integrity is affected after arthroscopic glenoid reconstruction. In the technique used, an autologous iliac crest graft is transported through the rotator interval, and the graft is fixed via an antero-inferior portal with compression screws. Methods 3 women and 6 men (mean age 31 ± 9 years, min 21, max 46 years) who had a preoperative glenoid deficit of 23% ± 6% (min 13%, max 29%) were included. In a follow-up after an interval of 34 months (min 19, max 50), MRI scans were performed on both shoulders. With ITK-SNAP, a 3D reconstruction software, the volume of the subscapularis muscle in the injured and contralateral shoulder was measured. In addition, signal intensity ratios (PSI) (infraspinatus muscle / cranial subscapularis muscle and infraspinatus muscle / caudal subscapularis muscle) were analyzed and the width of the cranial and caudal portions as well as the length of the subscapularis muscle in the parasagittal plane were determined. Results The 3D volume showed no difference between operated and healthy shoulders (p = 0.07), neither did PSI ratios (infraspinatus muscle / cranial subscapularis muscle: p = 1.00, infraspinatus muscle / caudal subscapularis muscle: p = 1.00). In the parasagittal plane, length (p = 0.09) and cranial width (p = 0.23) did not differ. However, the width of the lower muscle was increased in injured shoulders (p = 0.02). Conclusion In this cohort, no relevant volume loss could be found after arthroscopic glenoid reconstruction. However, a greater width of the lower muscle portion could be identified in the parasagittal plane as a possible indication of scarring.