VVVetri Velan

Vetri Velan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Vetri Velan has a total of 301 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Design studies of a pulsed quasimonoenergetic 2-keV neutron source for calibration of low threshold dark matter detectors

    by L. Chaplinsky, S. Fiorucci, C. W. Fink, M. Garcia-Sciveres, W. Guo, S. A. Hertel, J. K. Wuko, X. Li, J. Lin, R. Mahapatra, et al.

  • Spontaneous generation of athermal phonon bursts within bulk silicon causing excess noise, low energy background events, and quasiparticle poisoning in superconducting sensors

    by C. L. Chang, Y.-Y. Chang, M. Garcia-Sciveres, W. Guo, S. A. Hertel, X. Li, J. Lin, M. Lisovenko, R. Mahapatra, W. Matava, et al.

    Solid state phonon detectors used in the search for dark matter and coherent neutrino nucleus interactions (CE ν NS) require excellent energy resolution (eV-scale or below) and low backgrounds. An unknown source of phonon bursts, the low energy excess (LEE), dominates other above-threshold backgrounds and generates excess shot noise from subthreshold bursts. In this paper, we measure these phonon bursts for 12 days after cooldown in two nearly identical 1 cm2 silicon detectors that differ only in the thickness of their substrate (1 vs 4 mm thick). We find that both the channel-correlated shot noise and near-threshold shared LEE relax with time since cooldown. Additionally, both the correlated shot noise and LEE rates scale linearly with substrate thickness. When combined with previous measurements of other silicon phonon detectors with different substrate geometries and mechanical support strategies, these measurements strongly suggest that the dominant source of both above and below threshold LEE is the bulk substrate. By monitoring the relation between bias power and excess phonon shot noise, we estimate that the energy scale for subthreshold noise events is 0.68±0.38 meV. In our final dataset, we report a world-leading energy resolution of 258.5 ± 0.4 meV in the 1 mm thick detector. Simple calculations suggest that these silicon substrate phonon bursts are likely a significant source of quasiparticle poisoning in superconducting qubits operated in well shielded and vibration free environments.


  • Low energy backgrounds and excess noise in a two-channel low-threshold calorimeter

    by R. Anthony-Petersen, C. L. Chang, Y.-Y. Chang, L. Chaplinsky, C. W. Fink, M. Garcia-Sciveres, W. Guo, S. A. Hertel, X. Li, J. Lin, et al.

    We describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a transition edge sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: “shared” multichannel events with a pulse shape consistent with substrate athermal phonon events and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These “singles” are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.


  • Open Access

    A stress-induced source of phonon bursts and quasiparticle poisoning

    by Robin Anthony-Petersen, Andreas Biekert, Raymond Bunker, Clarence L. Chang, Yen-Yung Chang, Luke Chaplinsky, Eleanor Fascione, Caleb W. Fink, Maurice Garcia-Sciveres, Richard Germond, et al.

    The performance of superconducting qubits is degraded by a poorly characterized set of energy sources breaking the Cooper pairs responsible for superconductivity, creating a condition often called “quasiparticle poisoning”. Both superconducting qubits and low threshold dark matter calorimeters have observed excess bursts of quasiparticles or phonons that decrease in rate with time. Here, we show that a silicon crystal glued to its holder exhibits a rate of low-energy phonon events that is more than two orders of magnitude larger than in a functionally identical crystal suspended from its holder in a low-stress state. The excess phonon event rate in the glued crystal decreases with time since cooldown, consistent with a source of phonon bursts which contributes to quasiparticle poisoning in quantum circuits and the low-energy events observed in cryogenic calorimeters. We argue that relaxation of thermally induced stress between the glue and crystal is the source of these events.


  • Open Access

    Improved Dark Matter Search Sensitivity Resulting from LUX Low-Energy Nuclear Recoil Calibration

    by LUX Collaboration, D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, J. Balajthy, J. Bang, A. Baxter, E. P. Bernard, A. Bernstein, et al.

    Dual-phase xenon time projection chamber (TPC) detectors have demonstrated superior search sensitivities to dark matter over a wide range of particle masses. To extend their sensitivity to include low-mass dark matter interactions, it is critical to characterize both the light and charge responses of liquid xenon to sub-keV nuclear recoils. In this work, we report a new nuclear recoil calibration in the LUX detector $\textit{in situ}$ using neutron events from a pulsed Adelphi Deuterium-Deuterium neutron generator. We demonstrate direct measurements of light and charge yields down to 0.45 keV (1.4 scintillation photons) and 0.27 keV (1.3 ionization electrons), respectively, approaching the physical limit of liquid xenon detectors. We discuss the implication of these new measurements on the physics reach of dual-phase xenon TPCs for nuclear-recoil-based low-mass dark matter detection.


  • A backing detector for order-keV neutrons

    by A. Biekert, L. Chaplinsky, C.W. Fink, M. Garcia-Sciveres, W.C. Gillis, W. Guo, S.A. Hertel, G. Heuermann, X. Li, J. Lin, et al.


  • The Federal Science Project: A scientist in every classroom

    by Vetri Velan, Rachel Woods-Robinson, Elizabeth Case, Isabel Warner, Andrea Poppiti, Brian Abramowitz

    The United States urgently needs science-based solutions for a multitude of policy issues, and a basic societal understanding of science is essential to gaining public trust and addressing these issues. However, there is a disconnect between professional scientists and engineers and K-12 science education. Many students will graduate after 13 years of school having never met a scientist. This missed opportunity is not an issue of supply. There are over 7 million practicing scientists and engineers in the U.S.; if every scientist spent just one hour a year in a classroom, each student would get at least three visits from a scientist every single year. Here, we propose the Federal Science Project: a federally funded, nationwide program to bring scientists into all K-12 schools across the U.S. with the goal of reaching every student, regardless of geographic location. Scientists and engineers across disciplines and sectors would undergo training in communication skills and cultural competency, connect with classrooms via a national database with support from full-time staff, partner with teachers to deliver interactive lessons aligned with existing curriculum and standards, and receive appropriate compensation. Close partnerships between scientists, engineers, teachers, policymakers, and community partners in science education (science centers, museums, etc.) would invigorate the trust-based connections needed for 21st-century science education and policy transformations.

  • Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers

    by D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, J. Balajthy, A. Baxter, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, et al.

    We present a comprehensive analysis of electronic recoil vs nuclear recoil discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 2014–2016 runs of the Large Underground Xenon experiment. We observe strong charge-to-light discrimination enhancement with increased event energy. For events with S1=120 detected photons, i.e., equivalent to a nuclear recoil energy of ∼100  keV, we observe an electronic recoil background acceptance of <10−5 at a nuclear recoil signal acceptance of 50%. We also observe modest electric field dependence of the discrimination power, which peaks at a field of around 300  V/cm over the range of fields explored in this study (50–500  V/cm). In the weakly interacting massive particle search region of S1=1−80  phd, the minimum electronic recoil leakage we observe is (7.3±0.6)×10−4, which is obtained for a drift field of 240–290  V/cm. Pulse shape discrimination is utilized to improve our results, and we find that, at low energies and low fields, there is an additional reduction in background leakage by a factor of up to 3. We develop an empirical model for recombination fluctuations which, when used alongside the Noble Element Scintillation Technique simulation package, correctly reproduces the skewness of the electronic recoil data. We use this updated simulation to study the width of the electronic recoil band, finding that its dominant contribution comes from electron-ion recombination fluctuations, followed in magnitude of contribution by fluctuations in the S1 signal, fluctuations in the S2 signal, and fluctuations in the total number of quanta produced for a given energy deposition.


  • Open Access

    Streamlining USDA Regulation of Gene Editing to Benefit US Agriculture

    by Sarah Hartman, Wilson Horner, Christopher Jackson, Emma Kovak, Vetri Velan


  • Open Access

    Improved modeling of β electronic recoils in liquid xenon using LUX calibration data

    by D.S. Akerib, S. Alsum, H.M. Araújo, X. Bai, J. Balajthy, A. Baxter, E.P. Bernard, A. Bernstein, T.P. Biesiadzinski, E.M. Boulton, et al.

    We report here methods and techniques for creating an improved model that reproduces the scintillation and ionization response of a dual-phase liquid and gaseous xenon time projection chamber. Starting with the recent release of the Noble Element Simulation Technique (NEST v2.0), electronic recoil data from the β decays of 3H and 14C in the Large Underground Xenon (LUX) detector were used to tune the model, in addition to external data sets that allow for extrapolation beyond the LUX data-taking conditions. This paper also presents techniques used for modeling complicated temporal and spatial detector pathologies that can adversely affect data using a simplified model framework. The methods outlined in this report show an example of the robust applications possible with NEST v2.0 framework and how it can be modified to produce a final, detector-specific, electronic recoil model. This example provides the final model for LUX and detector parameters that will used in the new analysis package, the LUX Legacy Analysis Monte Carlo Application (LLAMA), for accurate reproduction of the LUX data. As accurate background reproduction is crucial for the success of rare-event searches, such as dark matter direct detection experiments, the techniques outlined here can be used in other single-phase and dual-phase xenon detectors to assist with accurate ER background reproduction.