Mirelle Maria Ruggiero
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mirelle Maria Ruggiero has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Altair Antoninha Del Bel Cury
State University of Campinas
6 shared publications - Yu Zhang
Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA, USA
5 shared publications - Mariana Itaborai Moreira Freitas
University of Campinas
3 shared publications - Raissa Micaella Marcello-Machado
Paulista University
3 shared publications - Estevam Augusto Bonfante
Department of Prosthodontics and Periodontology Bauru School of Dentistry, University of São Paulo Bauru São Paulo Brazil
2 shared publications - Leticia Vasconcelos Silva Souza
Universidade Estadual de Campinas (UNICAMP)
2 shared publications
Latest Publications
- Open Access
- 12 November 2026
- Published by Elsevier in Dental Materials
Non-isothermal sintering of dental zirconia for enhanced flexural strength and workflow efficiency without compromising translucency
- 12 November 2026
- Published by Elsevier in Dental Materials
Open AccessNon-isothermal sintering of dental zirconia for enhanced flexural strength and workflow efficiency without compromising translucency
- Open Access
- 25 September 2025
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 38 (2) , 340-353
Evaluating the Probability of Survival and Damage Mechanisms of Resin Matrix Ceramics: Insights Into Wear Progression and Surface Damage Under Fatigue
Objective: This study evaluated the probability of survival, failure modes, and fatigue‐induced wear progression, as well as assessed damage tolerance under simulated mastication in two resin matrix ceramics (polymer‐infiltrated ceramic networks (PICN) and resin nanoceramic (RNC)). Methodology: Specimens underwent step‐stress accelerated life testing (SSALT) ( n = 21), mouth‐motion simulation ( n = 12), followed by wear analysis and flexural strength testing. Probability of survival and flexural strength were analyzed using Weibull statistical modeling. Damage mechanisms were characterized by optical microscopy, scanning electron microscopy (SEM), and high‐resolution 3D quantitative analysis of wear depth and volumetric loss after mouth motion simulation. Two‐way ANOVA was used, followed by Tukey Post Hoc with a significance level of 5% ( α = 0.05). Results: At 600 N, PICN exhibited significantly lower probability of survival (6%) compared to RNC (60%). SEM images showed delamination and radial cracking for both groups, being more frequent in PICN. Both materials demonstrated progressively significant increases in volumetric wear with the increase in the number of cycles and showed 0.014 mm 3 for PICN and 0.016 mm 3 for RNC after 100,000. Flexural strength was higher for RNC (303 MPa) than for PICN (189 MPa). Also, it decreased after 1,000 cycles for PICN, while for RNC it decreased only after 100,000 cycles, and it was always higher than for PICN. SEM images showed that fracture originated at wear craters. Conclusions: RNC exhibited superior probability of survival, particularly under more demanding conditions compared to PICN. Both materials showed a progressive increase in surface wear as the number of cycles increased. The flexural strength of RNC remained consistently higher over time. Regarding failure mechanisms, both materials experienced delamination and crack formation; however, radial cracks were more frequently observed in PICN, indicating a higher susceptibility to structural failure under fatigue conditions. Clinical Significance: Selection of restorative materials must balance mechanical performance and long‐term durability under functional loading. Resin nanoceramic appears to be a more reliable option than polymer‐infiltrated ceramic networks for restorations in high‐stress areas, such as posterior teeth or patients with parafunctional habits.
- 25 September 2025
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 38 (2) , 340-353
Open AccessEvaluating the Probability of Survival and Damage Mechanisms of Resin Matrix Ceramics: Insights Into Wear Progression and Surface Damage Under Fatigue
Objective: This study evaluated the probability of survival, failure modes, and fatigue‐induced wear progression, as well as assessed damage tolerance under simulated mastication in two resin matrix ceramics (polymer‐infiltrated ceramic networks (PICN) and resin nanoceramic (RNC)). Methodology: Specimens underwent step‐stress accelerated life testing (SSALT) ( n = 21), mouth‐motion simulation ( n = 12), followed by wear analysis and flexural strength testing. Probability of survival and flexural strength were analyzed using Weibull statistical modeling. Damage mechanisms were characterized by optical microscopy, scanning electron microscopy (SEM), and high‐resolution 3D quantitative analysis of wear depth and volumetric loss after mouth motion simulation. Two‐way ANOVA was used, followed by Tukey Post Hoc with a significance level of 5% ( α = 0.05). Results: At 600 N, PICN exhibited significantly lower probability of survival (6%) compared to RNC (60%). SEM images showed delamination and radial cracking for both groups, being more frequent in PICN. Both materials demonstrated progressively significant increases in volumetric wear with the increase in the number of cycles and showed 0.014 mm 3 for PICN and 0.016 mm 3 for RNC after 100,000. Flexural strength was higher for RNC (303 MPa) than for PICN (189 MPa). Also, it decreased after 1,000 cycles for PICN, while for RNC it decreased only after 100,000 cycles, and it was always higher than for PICN. SEM images showed that fracture originated at wear craters. Conclusions: RNC exhibited superior probability of survival, particularly under more demanding conditions compared to PICN. Both materials showed a progressive increase in surface wear as the number of cycles increased. The flexural strength of RNC remained consistently higher over time. Regarding failure mechanisms, both materials experienced delamination and crack formation; however, radial cracks were more frequently observed in PICN, indicating a higher susceptibility to structural failure under fatigue conditions. Clinical Significance: Selection of restorative materials must balance mechanical performance and long‐term durability under functional loading. Resin nanoceramic appears to be a more reliable option than polymer‐infiltrated ceramic networks for restorations in high‐stress areas, such as posterior teeth or patients with parafunctional habits.
- Open Access
- 4 July 2025
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 38 (3) , 604-634
Is Additive Manufacturing of Dental Zirconia Comparable to Subtractive Methods When Considering Printing Orientation and Layer Thickness? A Systematic Review and Meta‐Analysis
Objective: The aim of this systematic review and meta‐analysis was to determine whether the production of monolithic dental zirconia using additive manufacturing (AM), with consideration of different printing directions and layer thicknesses, enhances its mechanical and physical properties relative to subtractive manufacturing (SM). Methodology: This systematic review followed PRISMA guidelines and was registered on the Open Science Framework. The PICO strategy was used, focusing on monolithic dental zirconia, comparing AM (stereolithography [SLA] and digital light processing [DLP]) with SM (i.e., CIPing/presintering/milling). In vitro studies were included. Electronic searches were conducted across multiple databases and gray literature, followed by data selection and extraction. Methodological quality was assessed using the QUIN tool for in vitro risk of bias. Mean and standard deviation of flexural strength, density, roughness, and specimen count per group were used to calculate the mean difference (MD) with a 95% confidence interval (CI) in the meta‐analysis. Results: A total of 31 studies were included in the qualitative synthesis and 21 in the quantitative analysis. Most were classified as having a medium risk of bias. The meta‐analysis indicated that AM zirconia exhibited lower flexural strength than SM zirconia. However, subgroup analyses revealed no significant difference in the flexural strength of samples fabricated using SLA technology or printed at the 0° orientation relative to SM zirconia. Individually, AM zirconia fabricated with 25 or 50 μm layer thicknesses possessed lower flexural strength than SM zirconia, regardless of print direction. No differences were observed between the manufacturing methods regarding surface roughness, although SM demonstrated significantly higher density than AM zirconia. Conclusions: AM dental zirconia demonstrated lower flexural strength when pooled across printing technologies, build orientations, and layer thicknesses. However, it exhibited comparable strength to SM zirconia at 0° or fabricated using SLA technology. Both AM and SM methods yielded similar surface roughness, with SM producing higher density. Most studies had a medium risk of bias, suggesting the need for further research and methodological rigor, particularly regarding translucency. Clinical Significance: Based on current in vitro evidence, AM zirconia may show potential for posterior crowns; however, further clinical validation is needed, especially for the anterior region due to insufficient translucency to meet esthetic demands.
- 4 July 2025
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 38 (3) , 604-634
Open AccessIs Additive Manufacturing of Dental Zirconia Comparable to Subtractive Methods When Considering Printing Orientation and Layer Thickness? A Systematic Review and Meta‐Analysis
Objective: The aim of this systematic review and meta‐analysis was to determine whether the production of monolithic dental zirconia using additive manufacturing (AM), with consideration of different printing directions and layer thicknesses, enhances its mechanical and physical properties relative to subtractive manufacturing (SM). Methodology: This systematic review followed PRISMA guidelines and was registered on the Open Science Framework. The PICO strategy was used, focusing on monolithic dental zirconia, comparing AM (stereolithography [SLA] and digital light processing [DLP]) with SM (i.e., CIPing/presintering/milling). In vitro studies were included. Electronic searches were conducted across multiple databases and gray literature, followed by data selection and extraction. Methodological quality was assessed using the QUIN tool for in vitro risk of bias. Mean and standard deviation of flexural strength, density, roughness, and specimen count per group were used to calculate the mean difference (MD) with a 95% confidence interval (CI) in the meta‐analysis. Results: A total of 31 studies were included in the qualitative synthesis and 21 in the quantitative analysis. Most were classified as having a medium risk of bias. The meta‐analysis indicated that AM zirconia exhibited lower flexural strength than SM zirconia. However, subgroup analyses revealed no significant difference in the flexural strength of samples fabricated using SLA technology or printed at the 0° orientation relative to SM zirconia. Individually, AM zirconia fabricated with 25 or 50 μm layer thicknesses possessed lower flexural strength than SM zirconia, regardless of print direction. No differences were observed between the manufacturing methods regarding surface roughness, although SM demonstrated significantly higher density than AM zirconia. Conclusions: AM dental zirconia demonstrated lower flexural strength when pooled across printing technologies, build orientations, and layer thicknesses. However, it exhibited comparable strength to SM zirconia at 0° or fabricated using SLA technology. Both AM and SM methods yielded similar surface roughness, with SM producing higher density. Most studies had a medium risk of bias, suggesting the need for further research and methodological rigor, particularly regarding translucency. Clinical Significance: Based on current in vitro evidence, AM zirconia may show potential for posterior crowns; however, further clinical validation is needed, especially for the anterior region due to insufficient translucency to meet esthetic demands.
- 13 June 2025
- Published by Elsevier in Dental Materials
- Vol. 41 (8) , 1014-1026
Implant-supported resin-matrix ceramic crowns with polyetheretherketone coping: a new rehabilitation system proposal
- 13 June 2025
- Published by Elsevier in Dental Materials
- Vol. 41 (8) , 1014-1026
Implant-supported resin-matrix ceramic crowns with polyetheretherketone coping: a new rehabilitation system proposal
- Open Access
- 10 April 2025
- Published by Elsevier in Dental Materials
- Vol. 41 (6) , 690-698
Balancing strength and translucency: The role of microstructure in additive and subtractive dental zirconia
- 10 April 2025
- Published by Elsevier in Dental Materials
- Vol. 41 (6) , 690-698
Open AccessBalancing strength and translucency: The role of microstructure in additive and subtractive dental zirconia
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 36, e236140
Resin matrix ceramic crowns cemented on titanium bases: effect of surface treatments and stress distribution
Using Titanium bases (TBs) has shown excellent results in implant-supported rehabilitation. However, failures due to decementation can occur, and bonding success depends on the TB surface treatment. This study evaluated the effect of different TB surface treatments on the retention and failure mode of resin matrix ceramic (RMC) crowns after thermocycling and the stress distribution of RMC cemented on the TBs. 120 TBs were divided into eight groups (n = 15) according to the material (resin nanoceramic (RNC) and polymer-infiltrated ceramic network (PICN)) and the surface treatment of the TBs: no treatment (NT); Airborne-particle abrasion with 50μm aluminum oxide (Al2O3) (AL); Airborne-particle abrasion with 30μm silica-modified Al2O3 particles (SIAL30) and Airborne-particle abrasion with 110μm silica-modified Al2O3 particles (SIAL110). After thermocycling, retention, and failure modes were analyzed. Retention data underwent two-way ANOVA and Tukey Post Hoc test (α=0.05). Finite element analysis (FEA) assessed stress distribution according to maximum principal stress (σmax) on the crown and maximum shear stress (τmax) on the cement layer. No significant difference was observed among the surface treatments or their interaction with the material (p > 0.05). However, RNC presented higher retention force values for all surface treatments (p<0.001). FEA showed a higher σmax for PICN (317.31 MPa) than RNC (277.69 MPa), while τmax was higher for RNC (246.54MPa) compared to PICN (213.55MPa). Most failures were cohesive in the material. In conclusion, surface treatments did not influence the retention of crowns to TBs, with the RNC having higher retention and better stress distribution for the crown.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 36, e236140
Open AccessResin matrix ceramic crowns cemented on titanium bases: effect of surface treatments and stress distribution
Using Titanium bases (TBs) has shown excellent results in implant-supported rehabilitation. However, failures due to decementation can occur, and bonding success depends on the TB surface treatment. This study evaluated the effect of different TB surface treatments on the retention and failure mode of resin matrix ceramic (RMC) crowns after thermocycling and the stress distribution of RMC cemented on the TBs. 120 TBs were divided into eight groups (n = 15) according to the material (resin nanoceramic (RNC) and polymer-infiltrated ceramic network (PICN)) and the surface treatment of the TBs: no treatment (NT); Airborne-particle abrasion with 50μm aluminum oxide (Al2O3) (AL); Airborne-particle abrasion with 30μm silica-modified Al2O3 particles (SIAL30) and Airborne-particle abrasion with 110μm silica-modified Al2O3 particles (SIAL110). After thermocycling, retention, and failure modes were analyzed. Retention data underwent two-way ANOVA and Tukey Post Hoc test (α=0.05). Finite element analysis (FEA) assessed stress distribution according to maximum principal stress (σmax) on the crown and maximum shear stress (τmax) on the cement layer. No significant difference was observed among the surface treatments or their interaction with the material (p > 0.05). However, RNC presented higher retention force values for all surface treatments (p<0.001). FEA showed a higher σmax for PICN (317.31 MPa) than RNC (277.69 MPa), while τmax was higher for RNC (246.54MPa) compared to PICN (213.55MPa). Most failures were cohesive in the material. In conclusion, surface treatments did not influence the retention of crowns to TBs, with the RNC having higher retention and better stress distribution for the crown.
- 24 September 2021
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 110 (3) , 638-645
Probability of survival and stress distribution of narrow diameter implants with different implant–abutment taper angles
This study evaluated the probability of survival, failure mode, and stress distribution of narrow diameter implants (NDIs) with internal implant–abutment conical connection comprised of different taper angles and thread designs. Sixty‐three NDIs (Ø 3.5 × 8.5 mm) were divided according to the taper angle (TA), internal diameter (ID), and trapezoidal thread design (TD) (n = 21/group), as follows: (a) 11.5°U (11.5° TA; ID: 2.5 mm; TD: dual threaded); (b) 11.5°S (11.5° TA; ID: 2.5 mm; TD: single threaded); (c) 16°S (16° TA; ID: 2.72 mm; TD: single threaded). They were subjected to step‐stress accelerated life testing. The reliability and use‐level probability Weibull curves were calculated at 50, 100, and 150 N for a mission of 100,000 cycles and the failure mode was analyzed using a scanning electron microscope. For finite element analysis the von‐Mises stress (σvM) was calculated for the abutment and implant. All groups showed high reliability (above 84%) and failures occurred predominantly in the abutment. In the FEA, 11.5°U showed higher σvM for the implant. All NDIs showed high reliability at clinically challenging loads. The system with greater taper angle showed lower σVm in the implant, and dual threaded implants showed a higher stress concentration in the implant and cortical bone.
- 24 September 2021
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 110 (3) , 638-645
Probability of survival and stress distribution of narrow diameter implants with different implant–abutment taper angles
This study evaluated the probability of survival, failure mode, and stress distribution of narrow diameter implants (NDIs) with internal implant–abutment conical connection comprised of different taper angles and thread designs. Sixty‐three NDIs (Ø 3.5 × 8.5 mm) were divided according to the taper angle (TA), internal diameter (ID), and trapezoidal thread design (TD) (n = 21/group), as follows: (a) 11.5°U (11.5° TA; ID: 2.5 mm; TD: dual threaded); (b) 11.5°S (11.5° TA; ID: 2.5 mm; TD: single threaded); (c) 16°S (16° TA; ID: 2.72 mm; TD: single threaded). They were subjected to step‐stress accelerated life testing. The reliability and use‐level probability Weibull curves were calculated at 50, 100, and 150 N for a mission of 100,000 cycles and the failure mode was analyzed using a scanning electron microscope. For finite element analysis the von‐Mises stress (σvM) was calculated for the abutment and implant. All groups showed high reliability (above 84%) and failures occurred predominantly in the abutment. In the FEA, 11.5°U showed higher σvM for the implant. All NDIs showed high reliability at clinically challenging loads. The system with greater taper angle showed lower σVm in the implant, and dual threaded implants showed a higher stress concentration in the implant and cortical bone.
- 1 March 2021
- Published by Elsevier in Dental Materials
- Vol. 37 (3) , e131-e139
Resin-matrix ceramics for occlusal veneers: Effect of thickness on reliability and stress distribution
- 1 March 2021
- Published by Elsevier in Dental Materials
- Vol. 37 (3) , e131-e139
Resin-matrix ceramics for occlusal veneers: Effect of thickness on reliability and stress distribution