Ekaterina E. Mirgorodskaya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ekaterina E. Mirgorodskaya has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Nikita P. Mityashin
Yuri Gagarin State Technical University of Saratov
17 shared publications - Ivan I. Artyukhov
Yuri Gagarin State Technical University of Saratov
5 shared publications Sergei F. Stepanov
Yuri Gagarin State Technical University of Saratov, Institute of Energy and Transport Systems, Saratov, 410054, Russia
5 shared publications- Yu.B. Tomashevskiy
Yuri Gagarin State Technical University of Saratov
4 shared publications - Mikhail E. Mamonychev
Yuri Gagarin State Technical University of Saratov
3 shared publications Vadim A. Kolchev
Yuri Gagarin State Technical University of Saratov
3 shared publications
Latest Publications
- 25 December 2024
- Published by I.N. Ulianov Chuvash State University in Vestnik Chuvashskogo universiteta
- No. 4
MULTILEVEL INVERTER TO GENERATE VOLTAGE WITH COMPLEX HARMONIC COMPOSITION
The paper deals with the problem of forming the desired and controllable harmonic composition of the output curve of a multilevel voltage inverter. The problem is relevant when creating installations for multi-frequency induction heating and metal melting. The purpose of the study is to develop an effective method to form the output voltage of power sources for multi-frequency induction heating installations, the curve of which has a given harmonic spectrum. Materials and methods. The theoretical part of the work was carried out on the basis of the circuit base of multi-level voltage inverters and switching DC converters using numerical analytical methods of studying nonlinear electrical circuits, methods of solving nonlinear differential equations and approximate harmonic analysis, as well as simulation modeling methods using the MATLAB/Simulink mathematical package. Experimental verification of the theoretical results was carried out in laboratory conditions on the example of a multi-level inverter generating a voltage curve with three operating harmonics. ACS758 series sensors and a four-channel RIGOL DS1104Z digital oscilloscope were used to record the results. Research results. Achieving of the purpose is based on the use of a universal multilevel voltage inverter, the circuit scheme of which does not depend on the levels number of the generated curve, which ensures a minimum number of power elements for any complexity of the curve spectrum. The method of forming of the output curve of this inverter consists in alternately connecting of the output capacitors of two direct voltage impulse converters to the input of a single-phase bridge voltage inverter using a transistor switch. In this case, voltages of different parity levels are formed by capacitors in the order of their succession, as a result of which a constant-sign multilevel voltage is formed on the input of the bridge inverter, corresponding to the required alternating-sign multilevel voltage. The law of the transistor switching of the bridge inverter ensures the conversion of its input voltage into a load voltage with a given harmonic composition. The peculiarity of the developed converter control method is that the transistor switching of the bridge inverter is carried out in accordance with the change in the sign of the generated curve. The method contains an algorithm to determine levels values formed by capacitors of impulse converters that realizes the required spectrum of the inverter output curve. The efficiency of the proposed method is illustrated by computer modeling of the converter when voltage with four working harmonics of the spectrum (i.e. the required spectrum harmonics) is generated. The quality indicators of the realized spectrum of the voltage curve are proposed and the analysis results of the influence of the levels number on values of these indicators are presented. The efficiency of the proposed methods is demonstrated experimentally with a laboratory model of the converter. Conclusions. The paper proposes a method to form the output voltage of a power source, the curve of which has a given harmonic, the efficiency of which is confirmed by the results of computer modeling and laboratory experiments. The proposed technical solutions made it possible to generate an output voltage, the spectrum of the curve of which contains four or more harmonics with specified amplitudes with a minimum number of power elements of the circuit. The paper also proposes models of quality indicators of the realized spectrum of the voltage curve and presents the results of the analysis of the influence of the number of levels on the values of these indicators. The developed methodology allows the development in the direction of controlling the spectrum of the generated voltage in real time, as well as non-periodic alternating voltage that changes according to a given program in accordance with the requirements of the technological process.
- 25 December 2024
- Published by I.N. Ulianov Chuvash State University in Vestnik Chuvashskogo universiteta
- No. 4
MULTILEVEL INVERTER TO GENERATE VOLTAGE WITH COMPLEX HARMONIC COMPOSITION
The paper deals with the problem of forming the desired and controllable harmonic composition of the output curve of a multilevel voltage inverter. The problem is relevant when creating installations for multi-frequency induction heating and metal melting. The purpose of the study is to develop an effective method to form the output voltage of power sources for multi-frequency induction heating installations, the curve of which has a given harmonic spectrum. Materials and methods. The theoretical part of the work was carried out on the basis of the circuit base of multi-level voltage inverters and switching DC converters using numerical analytical methods of studying nonlinear electrical circuits, methods of solving nonlinear differential equations and approximate harmonic analysis, as well as simulation modeling methods using the MATLAB/Simulink mathematical package. Experimental verification of the theoretical results was carried out in laboratory conditions on the example of a multi-level inverter generating a voltage curve with three operating harmonics. ACS758 series sensors and a four-channel RIGOL DS1104Z digital oscilloscope were used to record the results. Research results. Achieving of the purpose is based on the use of a universal multilevel voltage inverter, the circuit scheme of which does not depend on the levels number of the generated curve, which ensures a minimum number of power elements for any complexity of the curve spectrum. The method of forming of the output curve of this inverter consists in alternately connecting of the output capacitors of two direct voltage impulse converters to the input of a single-phase bridge voltage inverter using a transistor switch. In this case, voltages of different parity levels are formed by capacitors in the order of their succession, as a result of which a constant-sign multilevel voltage is formed on the input of the bridge inverter, corresponding to the required alternating-sign multilevel voltage. The law of the transistor switching of the bridge inverter ensures the conversion of its input voltage into a load voltage with a given harmonic composition. The peculiarity of the developed converter control method is that the transistor switching of the bridge inverter is carried out in accordance with the change in the sign of the generated curve. The method contains an algorithm to determine levels values formed by capacitors of impulse converters that realizes the required spectrum of the inverter output curve. The efficiency of the proposed method is illustrated by computer modeling of the converter when voltage with four working harmonics of the spectrum (i.e. the required spectrum harmonics) is generated. The quality indicators of the realized spectrum of the voltage curve are proposed and the analysis results of the influence of the levels number on values of these indicators are presented. The efficiency of the proposed methods is demonstrated experimentally with a laboratory model of the converter. Conclusions. The paper proposes a method to form the output voltage of a power source, the curve of which has a given harmonic, the efficiency of which is confirmed by the results of computer modeling and laboratory experiments. The proposed technical solutions made it possible to generate an output voltage, the spectrum of the curve of which contains four or more harmonics with specified amplitudes with a minimum number of power elements of the circuit. The paper also proposes models of quality indicators of the realized spectrum of the voltage curve and presents the results of the analysis of the influence of the number of levels on the values of these indicators. The developed methodology allows the development in the direction of controlling the spectrum of the generated voltage in real time, as well as non-periodic alternating voltage that changes according to a given program in accordance with the requirements of the technological process.
- Open Access
- 24 January 2024
- Published by Samara State Technical University in Vestnik of Samara State Technical University. Technical Sciences Series
- Vol. 31 (3) , 98-114
Selection of output inverter for microgrid
The paper considers the problem of a microgrid output inverter selecting, when information about operating conditions is uncertain. The following factors are considered as sources of uncertainty in information about operating conditions: the possibility of the load increasing in the area, for which the microgrid is being designed, the prospects for its integration into the local power supply system, based on the microgrid, operating in the given region, as well as possible changes in the element base due to import substitution. A system of criteria and a methodology for optimal selection have been developed, based on a combination of multi-vector optimization approaches and the hierarchy analysis method. The quality criterion of generated energy, the criterion of reliable operation in conditions of information uncertainty and the criterion of economic indicators were cho- sen as vector criteria. The total number of scalar criteria that are components of the specified vector criteria is seven. At the first stage of selection, an algorithm is used for expert assessment of the importance of vector criteria and their scalar components, as well as values of these criteria for compared alternatives, using of the hierarchy analysis method. At the second stage of selection, considered inverters are ranked according to a global criterion, calculated based on results of the first stage. The technique is demon- strated by choosing between three well-known schemes of autonomous inverters: a voltage inverter with PWM-shaping of the output curve, a current inverter with a variable struc- ture and a group multilevel inverter based on a universal source of levels, when they are operating in autonomous or integrated into the system of other microgrid modes. The de- scribed selection technique can be used, when other microgrid conversion equipment de- vices are selecting.
- 24 January 2024
- Published by Samara State Technical University in Vestnik of Samara State Technical University. Technical Sciences Series
- Vol. 31 (3) , 98-114
Open AccessSelection of output inverter for microgrid
The paper considers the problem of a microgrid output inverter selecting, when information about operating conditions is uncertain. The following factors are considered as sources of uncertainty in information about operating conditions: the possibility of the load increasing in the area, for which the microgrid is being designed, the prospects for its integration into the local power supply system, based on the microgrid, operating in the given region, as well as possible changes in the element base due to import substitution. A system of criteria and a methodology for optimal selection have been developed, based on a combination of multi-vector optimization approaches and the hierarchy analysis method. The quality criterion of generated energy, the criterion of reliable operation in conditions of information uncertainty and the criterion of economic indicators were cho- sen as vector criteria. The total number of scalar criteria that are components of the specified vector criteria is seven. At the first stage of selection, an algorithm is used for expert assessment of the importance of vector criteria and their scalar components, as well as values of these criteria for compared alternatives, using of the hierarchy analysis method. At the second stage of selection, considered inverters are ranked according to a global criterion, calculated based on results of the first stage. The technique is demon- strated by choosing between three well-known schemes of autonomous inverters: a voltage inverter with PWM-shaping of the output curve, a current inverter with a variable struc- ture and a group multilevel inverter based on a universal source of levels, when they are operating in autonomous or integrated into the system of other microgrid modes. The de- scribed selection technique can be used, when other microgrid conversion equipment de- vices are selecting.
- Open Access
- 22 January 2024
- Published by Oxford University Press (OUP) in JBMR Plus
- Vol. 8 (2) , ziae006
Glycoproteomic profile of human tissue-nonspecific alkaline phosphatase expressed in osteoblasts
Tissue-nonspecific alkaline phosphatase (TNALP) is a glycoprotein expressed by osteoblasts that promotes bone mineralization. TNALP catalyzes the hydrolysis of the mineralization inhibitor inorganic pyrophosphate and ATP to provide inorganic phosphate, thus controlling the inorganic pyrophosphate/inorganic phosphate ratio to enable the growth of hydroxyapatite crystals. N-linked glycosylation of TNALP is essential for protein stability and enzymatic activity and is responsible for the presence of different bone isoforms of TNALP associated with functional and clinical differences. The site-specific glycosylation profiles of TNALP are, however, elusive. TNALP has 5 potential N-glycosylation sites located at the asparagine (N) residues 140, 230, 271, 303, and 430. The objective of this study was to reveal the presence and structure of site-specific glycosylation in TNALP expressed in osteoblasts. Calvarial osteoblasts derived from Alpl+/− expressing SV40 Large T antigen were transfected with soluble epitope-tagged human TNALP. Purified TNALP was analyzed with a lectin microarray, matrix-assisted laser desorption/ionization-time of flight mass spectrometry, and liquid chromatography with tandem mass spectrometry. The results showed that all sites (n = 5) were fully occupied predominantly with complex-type N-glycans. High abundance of galactosylated biantennary N-glycans with various degrees of sialylation was observed on all sites, as well as glycans with no terminal galactose and sialic acid. Furthermore, all sites had core fucosylation except site N271. Modelling of TNALP, with the protein structure prediction software ColabFold, showed possible steric hindrance by the adjacent side chain of W270, which could explain the absence of core fucosylation at N271. These novel findings provide evidence for N-linked glycosylation on all 5 sites of TNALP, as well as core fucosylation on 4 out of 5 sites. We anticipate that this new knowledge can aid in the development of functional and clinical assays specific for the TNALP bone isoforms. Graphical abstract illustrating the N-glycosylation profile of tissue-nonspecific alkaline phosphatase. The 5 sites N140, N230, N271, N303, and N430 were fully occupied by predominantly biantennary complex-type N-glycans composed of N-acetylglucosamine (GlcNAc), mannose (Man), galactose (Gal), and sialic acid (Sia). Only site N271 did not have core fucose (Fuc). Tissue-nonspecific alkaline phosphatase (TNALP) is a protein that plays a key role in bone formation and mineralization. TNALP produced by bone-forming osteoblast cells is known as bone alkaline phosphatase (BALP). Serum BALP is also a clinically important biomarker of bone formation. The biochemical difference between BALP and other sorts of TNALP is how the protein is processed in the cells by a protein modification process known as glycosylation. During glycosylation, different sugar molecules are synthetized and coupled to specific parts of the TNALP sequence, thereby creating a diverse mixture of protein glycoforms with various length of sugar chains. However, the glycosylation structure and site abundance of glycosylation in TNALP are unknown. In this study, we used different techniques to study protein glycosylation of TNALP synthetized by osteoblasts and found that all hypothetical sites of TNALP were fully glycosylated, which has not been demonstrated before. Furthermore, we found that the glycosylated sites had mixtures of different sugar chains, which might lead to the presence of different glycoforms (isoforms) of BALP. Further studies will examine how the observed sugar chains differ between the BALP glycoforms and what functional role they have in bone formation and mineralization.
- 22 January 2024
- Published by Oxford University Press (OUP) in JBMR Plus
- Vol. 8 (2) , ziae006
Open AccessGlycoproteomic profile of human tissue-nonspecific alkaline phosphatase expressed in osteoblasts
Tissue-nonspecific alkaline phosphatase (TNALP) is a glycoprotein expressed by osteoblasts that promotes bone mineralization. TNALP catalyzes the hydrolysis of the mineralization inhibitor inorganic pyrophosphate and ATP to provide inorganic phosphate, thus controlling the inorganic pyrophosphate/inorganic phosphate ratio to enable the growth of hydroxyapatite crystals. N-linked glycosylation of TNALP is essential for protein stability and enzymatic activity and is responsible for the presence of different bone isoforms of TNALP associated with functional and clinical differences. The site-specific glycosylation profiles of TNALP are, however, elusive. TNALP has 5 potential N-glycosylation sites located at the asparagine (N) residues 140, 230, 271, 303, and 430. The objective of this study was to reveal the presence and structure of site-specific glycosylation in TNALP expressed in osteoblasts. Calvarial osteoblasts derived from Alpl+/− expressing SV40 Large T antigen were transfected with soluble epitope-tagged human TNALP. Purified TNALP was analyzed with a lectin microarray, matrix-assisted laser desorption/ionization-time of flight mass spectrometry, and liquid chromatography with tandem mass spectrometry. The results showed that all sites (n = 5) were fully occupied predominantly with complex-type N-glycans. High abundance of galactosylated biantennary N-glycans with various degrees of sialylation was observed on all sites, as well as glycans with no terminal galactose and sialic acid. Furthermore, all sites had core fucosylation except site N271. Modelling of TNALP, with the protein structure prediction software ColabFold, showed possible steric hindrance by the adjacent side chain of W270, which could explain the absence of core fucosylation at N271. These novel findings provide evidence for N-linked glycosylation on all 5 sites of TNALP, as well as core fucosylation on 4 out of 5 sites. We anticipate that this new knowledge can aid in the development of functional and clinical assays specific for the TNALP bone isoforms. Graphical abstract illustrating the N-glycosylation profile of tissue-nonspecific alkaline phosphatase. The 5 sites N140, N230, N271, N303, and N430 were fully occupied by predominantly biantennary complex-type N-glycans composed of N-acetylglucosamine (GlcNAc), mannose (Man), galactose (Gal), and sialic acid (Sia). Only site N271 did not have core fucose (Fuc). Tissue-nonspecific alkaline phosphatase (TNALP) is a protein that plays a key role in bone formation and mineralization. TNALP produced by bone-forming osteoblast cells is known as bone alkaline phosphatase (BALP). Serum BALP is also a clinically important biomarker of bone formation. The biochemical difference between BALP and other sorts of TNALP is how the protein is processed in the cells by a protein modification process known as glycosylation. During glycosylation, different sugar molecules are synthetized and coupled to specific parts of the TNALP sequence, thereby creating a diverse mixture of protein glycoforms with various length of sugar chains. However, the glycosylation structure and site abundance of glycosylation in TNALP are unknown. In this study, we used different techniques to study protein glycosylation of TNALP synthetized by osteoblasts and found that all hypothetical sites of TNALP were fully glycosylated, which has not been demonstrated before. Furthermore, we found that the glycosylated sites had mixtures of different sugar chains, which might lead to the presence of different glycoforms (isoforms) of BALP. Further studies will examine how the observed sugar chains differ between the BALP glycoforms and what functional role they have in bone formation and mineralization.
- Open Access
- 4 December 2022
- Published by Samara State Technical University in Vestnik of Samara State Technical University. Technical Sciences Series
- Vol. 30 (3) , 128-140
Determination of the optimal location of power plants as a part of an autonomous power supply system based on renewable ener-gy sources
The paper proposes the problem solution of optimal location determining of several power stations in some region. These stations receive primary energy from renewable sources, such as solar panels and wind turbines. At the same time, the condition of the problem includes the availability of information on several perspective areas in this region for the placement of such power stations, as well as information of values and distribution of loads. The developed algorithm for solving of the optimal location selection problem of power stations consists of several stages. The content of the first stage of the algorithm is ranking of possible areas for the location of power stations using local criteria, which are proposed as the specific estimated cost of station arrangement, the remoteness of the proposed location of the power station from loads and settlements. The second stage of the algorithm consists in a set formation of possible areas for the location of stations. And at the final stage of the algorithm, they are ranked using system criteria that evaluate these sets of areas for the location of power stations as a power supply system. The estimated cost of a power supply system arrangement based on power stations, located on areas of the rated set, the specific estimated cost of power stations arrangement, applied to the set of power stations with power lines as an autonomous power supply system, as well as the average rating of areas are proposed as system criteria. In this case, the decision maker, after familiarizing with values of system criteria, sets critical boundaries for each of them. The result of the algorithm is a certain totality of prospective sets for the location of several power stations in a given region, estimates of which according to system criteria are the best correspond to preferences of the decision maker. A feature of the proposed approach is the participation of the decision maker at all stages of design.
- 4 December 2022
- Published by Samara State Technical University in Vestnik of Samara State Technical University. Technical Sciences Series
- Vol. 30 (3) , 128-140
Open AccessDetermination of the optimal location of power plants as a part of an autonomous power supply system based on renewable ener-gy sources
The paper proposes the problem solution of optimal location determining of several power stations in some region. These stations receive primary energy from renewable sources, such as solar panels and wind turbines. At the same time, the condition of the problem includes the availability of information on several perspective areas in this region for the placement of such power stations, as well as information of values and distribution of loads. The developed algorithm for solving of the optimal location selection problem of power stations consists of several stages. The content of the first stage of the algorithm is ranking of possible areas for the location of power stations using local criteria, which are proposed as the specific estimated cost of station arrangement, the remoteness of the proposed location of the power station from loads and settlements. The second stage of the algorithm consists in a set formation of possible areas for the location of stations. And at the final stage of the algorithm, they are ranked using system criteria that evaluate these sets of areas for the location of power stations as a power supply system. The estimated cost of a power supply system arrangement based on power stations, located on areas of the rated set, the specific estimated cost of power stations arrangement, applied to the set of power stations with power lines as an autonomous power supply system, as well as the average rating of areas are proposed as system criteria. In this case, the decision maker, after familiarizing with values of system criteria, sets critical boundaries for each of them. The result of the algorithm is a certain totality of prospective sets for the location of several power stations in a given region, estimates of which according to system criteria are the best correspond to preferences of the decision maker. A feature of the proposed approach is the participation of the decision maker at all stages of design.
- 29 September 2021
- Published by I.N. Ulianov Chuvash State University in Vestnik Chuvashskogo universiteta
- No. 3
SIMULATION OF COMMUTATION PROCESSES OF MULTI-LEVEL VOLTAGE INVERTER SWITCHES
An algorithm for controlling of commutator’s transistors of a single-phase multi-level voltage inverter is presented. The structure of the power circuit of the considered converter, in contrast to most existing circuits, does not depend on the levels number of the output curve due to the using of an universal source of levels, which are formed by output capacitors of two pulsed DC-converters. The commutator control algorithm ensures the formation of the required output curve of the inverter and excludes the occurrence of emergency situations during level commutating. Features of the converter and commutator operation in modes of active power transmission from pulse converters to the load and perception of the reactive power of the inverter load by them are considered. The commutator operation algorithm determines the sequence of control pulses, applied to the base of transistors, the sequence being synchronized with the process of the output voltage curve forming, as well as the direction of the inverter input current. At the same time, features of the level commutating are considered. They differ in the transition direction in value of level voltages: «up» from a lower value to a higher one and «down» from a higher value to a lower one. The sequence of supply and removal of pulses from control electrodes of switches and commutations caused by them, when the inverter input current is positive, are given. The similar commutating of levels is realized, when the inverter input current is negative. Wherein indexes of switches are rearranged in accordance with the direction replacement of their switching of the commutator circuit. A commutator model is realized using Micro-Cap 12 to demonstrate the operation of the algorithm. The transistor MJ15003 model is used as a commutator’s switch. In the model, output capacitors of pulse converters are represented by voltage sources, an autonomous inverter – by an active inductive load. The commutating from a higher voltage level to a lower one with a positive input current of the inverter is considered as an example. Simulation results confirm the performance of the algorithm.
- 29 September 2021
- Published by I.N. Ulianov Chuvash State University in Vestnik Chuvashskogo universiteta
- No. 3
SIMULATION OF COMMUTATION PROCESSES OF MULTI-LEVEL VOLTAGE INVERTER SWITCHES
An algorithm for controlling of commutator’s transistors of a single-phase multi-level voltage inverter is presented. The structure of the power circuit of the considered converter, in contrast to most existing circuits, does not depend on the levels number of the output curve due to the using of an universal source of levels, which are formed by output capacitors of two pulsed DC-converters. The commutator control algorithm ensures the formation of the required output curve of the inverter and excludes the occurrence of emergency situations during level commutating. Features of the converter and commutator operation in modes of active power transmission from pulse converters to the load and perception of the reactive power of the inverter load by them are considered. The commutator operation algorithm determines the sequence of control pulses, applied to the base of transistors, the sequence being synchronized with the process of the output voltage curve forming, as well as the direction of the inverter input current. At the same time, features of the level commutating are considered. They differ in the transition direction in value of level voltages: «up» from a lower value to a higher one and «down» from a higher value to a lower one. The sequence of supply and removal of pulses from control electrodes of switches and commutations caused by them, when the inverter input current is positive, are given. The similar commutating of levels is realized, when the inverter input current is negative. Wherein indexes of switches are rearranged in accordance with the direction replacement of their switching of the commutator circuit. A commutator model is realized using Micro-Cap 12 to demonstrate the operation of the algorithm. The transistor MJ15003 model is used as a commutator’s switch. In the model, output capacitors of pulse converters are represented by voltage sources, an autonomous inverter – by an active inductive load. The commutating from a higher voltage level to a lower one with a positive input current of the inverter is considered as an example. Simulation results confirm the performance of the algorithm.
- 2 December 2020
- Published by Springer Nature
- p. 194-208
A Technique for Multicriteria Structural Optimization of a Complex Energy System Based on Decomposition and Aggregation
- 2 December 2020
- Published by Springer Nature
- p. 194-208
A Technique for Multicriteria Structural Optimization of a Complex Energy System Based on Decomposition and Aggregation
- Open Access
- 1 March 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 791 (1)
Energy efficient multi-circuit cogeneration plant
The paper reviews an energy efficient multi-circuit power plant with three independent power generation circuits and a generator control system. The proposed three-circuit autonomous power plant was constructed in accordance with a modular design. The structural scheme, design, operating modes, and simulation model in the Matlab+Simulink environment is presented. The increase in electrical efficiency at this cogeneration plant is due to the use of low-temperature boiling point heat-transfer fluids. This article proposes the method of increasing the efficiency of an existing installation from 60 kW to 100 kW by equipping it with additional equipment. This equipment provides deeper utilization of flue gas heat. If the base power plant is 60 kW, the heat input is about 200 kWh (an efficiency of the station is 30%), then the total electricity generation will be 100 kW. In this case, an additional 40 kW of power is without increasing fuel consumption.
- 1 March 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 791 (1)
Open AccessEnergy efficient multi-circuit cogeneration plant
The paper reviews an energy efficient multi-circuit power plant with three independent power generation circuits and a generator control system. The proposed three-circuit autonomous power plant was constructed in accordance with a modular design. The structural scheme, design, operating modes, and simulation model in the Matlab+Simulink environment is presented. The increase in electrical efficiency at this cogeneration plant is due to the use of low-temperature boiling point heat-transfer fluids. This article proposes the method of increasing the efficiency of an existing installation from 60 kW to 100 kW by equipping it with additional equipment. This equipment provides deeper utilization of flue gas heat. If the base power plant is 60 kW, the heat input is about 200 kWh (an efficiency of the station is 30%), then the total electricity generation will be 100 kW. In this case, an additional 40 kW of power is without increasing fuel consumption.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Multi-modular Wind Generators for Urban Wind Power
The paper presents a study of operative modes of 3, 6 and 12-bladed wind turbines of low power with the same swept area, designed on the same type of electric generators. The study was carried out for a wide range of wind speeds. The comparison of efficiency of wind generators operating on a load and on a battery was made.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Multi-modular Wind Generators for Urban Wind Power
The paper presents a study of operative modes of 3, 6 and 12-bladed wind turbines of low power with the same swept area, designed on the same type of electric generators. The study was carried out for a wide range of wind speeds. The comparison of efficiency of wind generators operating on a load and on a battery was made.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Method of Solving of the Problem of the Reactive Power of the Load in Multilevel Inverters
The paper provides schematic solutions that implement the proposed method of the perceiving of the reactive power of the load, laws of the controlling switches. The comparison of considered solutions of the problem of the reactive power of the load in multilevel voltage inverters is carried out with using of computer models.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Method of Solving of the Problem of the Reactive Power of the Load in Multilevel Inverters
The paper provides schematic solutions that implement the proposed method of the perceiving of the reactive power of the load, laws of the controlling switches. The comparison of considered solutions of the problem of the reactive power of the load in multilevel voltage inverters is carried out with using of computer models.