Adam Swidziński
Adam Swidziński has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Leszek Morzyński
Central Institute for Labour Protection – National Research Institute, Warsaw, Poland
3 shared publications - Rafał Młyński
Department of Vibroacoustic Hazards, Central Institute for Labour Protection—National Research Institute, Czerniakowska 16, 00-701 Warsaw, Poland
3 shared publications - Jolanta Karpowicz
Central Institute for Labour Protection—National Research Institute (CIOP-PIB), 00-701 Warszawa, Poland
2 shared publications - Konrad Godziszewski
Institute of Radioelectronics and Multimedia Technology, Warsaw University of Technology, Warsaw, Poland
2 shared publications - Krzysztof Gryz
Central Institute for Labour Protection—National Research Institute (CIOP-PIB), 00-701 Warszawa, Poland
2 shared publications - Patryk Zradziński
Central Institute for Labour Protection—National Research Institute (CIOP-PIB), 00-701 Warszawa, Poland
2 shared publications
Latest Publications
- Open Access
- 11 July 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (14) , 8482
A Tester to Evaluate the Correct Placement of Earplugs
The use of hearing protection devices is one possible way of reducing the negative impact of noise on hearing. However, it is important to keep in mind that only properly used hearing protection devices provide adequate hearing protection. The aim of this article is to describe a newly developed tester to verify the correct placement of earplugs in the ear canal. This tester was developed using easily accessible and low-cost components. It implements the real-ear attenuation at threshold (REAT) method by which the sound attenuation of hearing protection devices is determined. The headphones with a greater low-frequency attenuation value were selected for use in the tester. The results of the sound attenuation measurement performed with the use of the tester did not differ by more than 5 dB compared to the measurements performed with the use of the Norsonic NOR838 system dedicated to this purpose. The developed tester is considered to be a device that will obtain reliable sound attenuation values. Thus, it can also be used as a device with which the correct placement of earplugs in the ear canal can be assessed.
- 11 July 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (14) , 8482
Open AccessA Tester to Evaluate the Correct Placement of Earplugs
The use of hearing protection devices is one possible way of reducing the negative impact of noise on hearing. However, it is important to keep in mind that only properly used hearing protection devices provide adequate hearing protection. The aim of this article is to describe a newly developed tester to verify the correct placement of earplugs in the ear canal. This tester was developed using easily accessible and low-cost components. It implements the real-ear attenuation at threshold (REAT) method by which the sound attenuation of hearing protection devices is determined. The headphones with a greater low-frequency attenuation value were selected for use in the tester. The results of the sound attenuation measurement performed with the use of the tester did not differ by more than 5 dB compared to the measurements performed with the use of the Norsonic NOR838 system dedicated to this purpose. The developed tester is considered to be a device that will obtain reliable sound attenuation values. Thus, it can also be used as a device with which the correct placement of earplugs in the ear canal can be assessed.
- Open Access
Modelling the Influence of Electromagnetic Field on the User of a Wearable IoT Device Used in a WSN for Monitoring and Reducing Hazards in the Work Environment
The aim of this study was to evaluate the absorption in a user’s head of an electromagnetic field (EMF) emitted by the Wi-Fi and/or Bluetooth module of a wearable small Internet of Things (IoT) electronic device (emitting EMF of up to 100 mW), in order to test the hypothesis that EMF has an insignificant influence on humans, and to compare the levels of such EMF absorption in various scenarios when using this device. The modelled EMF source was a meandered inverted-F antenna (MIFA)-type antenna of the ESP32-WROOM-32 radio module used in wearable devices developed within the reported study. To quantify the EMF absorption, the specific energy absorption rate (SAR) values were calculated in a multi-layer ellipsoidal model of the human head (involving skin, fat, skull bones and brain layers). The obtained results show up to 10 times higher values of SAR from the MIFA located in the headband, in comparison to its location on the helmet. Only wearable IoT devices (similar in construction and way of use to the investigated device) emitting at below 3 mW equivalent isotropically radiated power (EIRP) from Wi-Fi/Bluetooth communications modules may be considered environmentally insignificant EMF sources.
Open AccessModelling the Influence of Electromagnetic Field on the User of a Wearable IoT Device Used in a WSN for Monitoring and Reducing Hazards in the Work Environment
The aim of this study was to evaluate the absorption in a user’s head of an electromagnetic field (EMF) emitted by the Wi-Fi and/or Bluetooth module of a wearable small Internet of Things (IoT) electronic device (emitting EMF of up to 100 mW), in order to test the hypothesis that EMF has an insignificant influence on humans, and to compare the levels of such EMF absorption in various scenarios when using this device. The modelled EMF source was a meandered inverted-F antenna (MIFA)-type antenna of the ESP32-WROOM-32 radio module used in wearable devices developed within the reported study. To quantify the EMF absorption, the specific energy absorption rate (SAR) values were calculated in a multi-layer ellipsoidal model of the human head (involving skin, fat, skull bones and brain layers). The obtained results show up to 10 times higher values of SAR from the MIFA located in the headband, in comparison to its location on the helmet. Only wearable IoT devices (similar in construction and way of use to the investigated device) emitting at below 3 mW equivalent isotropically radiated power (EIRP) from Wi-Fi/Bluetooth communications modules may be considered environmentally insignificant EMF sources.
- Open Access
- 14 November 2020
- Published by MDPI AG in Engineering Proceedings
- Vol. 2 (1) , 39
Modelling the Influence of the 2.4 GHz Electromagnetic Field on the User of a Wearable Internet of Things (IoT) Device for Monitoring Hazards in the Work Environment
The aim was to test the hypothesis that there is an insignificant influence on humans from the absorption of an 2.4 GHz electromagnetic field (EMF) emitted by wearable Internet of Things (IoT) devices (using Meandered Inverted-F Antenna (MIFA) for Wi-Fi and Bluetooth technologies) for monitoring hazards in the work environment. To quantify problem, the specific energy absorption rate (SAR) was calculated in a multi-layer ellipsoidal model of the IoT device user’s head exposed to EMF from MIFA attached to a headband or to a helmet. SAR values may be significant when a modelled IoT wearable device is attached to a headband, but not to a helmet.
- 14 November 2020
- Published by MDPI AG in Engineering Proceedings
- Vol. 2 (1) , 39
Open AccessModelling the Influence of the 2.4 GHz Electromagnetic Field on the User of a Wearable Internet of Things (IoT) Device for Monitoring Hazards in the Work Environment
The aim was to test the hypothesis that there is an insignificant influence on humans from the absorption of an 2.4 GHz electromagnetic field (EMF) emitted by wearable Internet of Things (IoT) devices (using Meandered Inverted-F Antenna (MIFA) for Wi-Fi and Bluetooth technologies) for monitoring hazards in the work environment. To quantify problem, the specific energy absorption rate (SAR) was calculated in a multi-layer ellipsoidal model of the IoT device user’s head exposed to EMF from MIFA attached to a headband or to a helmet. SAR values may be significant when a modelled IoT wearable device is attached to a headband, but not to a helmet.