Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Simone Peloso has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Response of an Existing Two-Storey RC Frame Designed for Gravity Loads: In Situ Pushover Tests and Numerical Analyses

    by Simone Peloso, Chiara Casarotti, Filippo Dacarro, Giuseppe Sinopoli

    The purpose of the research was to study the response of existing constructions, designed for gravity loads only in the South of Italy, more precisely in the Sicily Region. The building is an existing two-story reinforced concrete structure, built in the ‘80s. In order to design the test, numerical study on the structure has been conducted, using information reported on original design drawings or derived by in situ geometric and material investigation. A number of numerical models and pushover analyses of the structure have been carried out, in order to account for the uncertainties related to possible different responses. The numerical analyses aimed at estimating the capacity of the structure in terms of both force and displacement, the ductility reserve, and the most likely sequence of formation of plastic hinges. The pseudo-static cyclic test was designed to push and pull the building in one direction at increasing displacement levels, up to a drift of about 2%. At the end of the test, the infill panels were completely collapsed. Beams, columns, and joints showed plastic hinges and shear failures in different parts of the structure, with spread spalling of the concrete. Numerical and experimental results were found in fair agreement.


  • Seismic numerical modelling of suspended piping trapeze restraint installations based on component testing

    by Daniele Perrone, Emanuele Brunesi, Andre Filiatrault, Simone Peloso, Roberto Nascimbene, Clemens Beiter, Roberto Piccinin


  • Experimental seismic response evaluation of suspended piping restraint installations

    by Daniele Perrone, Andre Filiatrault, Simone Peloso, Emanuele Brunesi, Clemens Beiter, Roberto Piccinin


  • Shake‐Table Testing of a Full‐Scale Two‐Story Precast Wall‐Slab‐Wall Structure

    by Emanuele Brunesi, Simone Peloso, Rui Pinho, Roberto Nascimbene

    Precast wall‐slab‐wall buildings can be found in many different earthquake‐prone areas of the world. This type of building structure features no beams or columns but rather precast walls and slabs alone that are joined together by means of steel connectors and mortar, both of which will not necessarily prevent the formation of relative sliding between structural members when the structure is subjected to certain levels of horizontal excitation, rendering them particularly vulnerable to seismic loading. Given the scarce amount of information/data on the seismic behavior of these structures, a dynamic shake‐table test was undertaken to investigate the response/performance of a full‐scale two‐story reinforced precast concrete wall‐slab‐wall structure, up to incipient/near collapse. The building mock‐up was subjected to five test runs of progressively increased intensity and collapsed because of failure of the steel connectors used to join the longitudinal and transverse walls. Test data are openly available and archived at the Natural Hazards Engineering Research Infrastructure DesignSafe Data Depot.


  • Friction characterization testing of fabric felt material used in precast structures

    by Emanuele Brunesi, Simone Peloso, Rui Pinho, Roberto Nascimbene

    Felt material is sometimes employed in precast wall‐slab‐wall structures featuring no mechanical devices for the wall‐slab connection. This implies that the frictional properties of these felts should be high enough to permit horizontal lateral forces on a building to be carried through them, preventing the sliding of slabs on precast walls and eventually their unseating. In light of this, friction testing of fabric felt material has been undertaken, combining triplet‐monotonic and cyclic‐symmetric tests, with a view to characterize this material, allowing not only an estimate of the shear force transferred, in actual buildings, between the slabs and the precast walls underneath them, but also a likely force‐displacement relationship that may be employed in numerical modeling efforts. Comparisons with data from a recent full‐scale building test corroborate the results obtained by the two‐step experimental investigation presented in this paper, thus adding further weight to the modeling recommendations herein provided.


  • Cyclic tensile testing of a three‐way panel connection for precast wall‐slab‐wall structures

    by Emanuele Brunesi, Simone Peloso, Rui Pinho, Roberto Nascimbene

    Wall‐slab‐wall buildings, in precast configuration or not, are relatively widespread in many European and non‐European countries, independently of the level and nature of seismic hazard to which the country is prone. Thus, this building archetype, featuring no columns or beams, but only slabs and walls, can be equally found both in areas characterized by potentially high‐damaging tectonic earthquakes and regions where small‐to‐medium‐size natural/anthropogenic seismic events would instead be expected.Notwithstanding the above, relatively little information has been offered so far on the seismic response/performance of these structures and their key components, which in case of a precast system/layout will inevitably be the connections between the structural elements. To partly fill such knowledge gap, this paper concerns the latter configuration and deals with experimental testing of panel‐to‐panel joints, which are not only two‐way links but also three‐way connections because it is very common for such structures that contiguous panels are connected to a transverse shear wall.Not surprisingly, very recent pseudostatic and shake‐table tests on full‐scale specimens, undertaken by the authors to characterize the performance of this structural system up to incipient/near collapse, have indicated how the latter panel joints are the weakest link of the system tested, thus prompting further component testing, in cyclic/asymmetric fashion, to single out the response of the joint. Monotonic and cyclic response curves of the five specimens and the counterpart damage patterns revealed that the observed flexural failure mechanism is very stable and aligns very well with that mobilized by the full‐scale building tests.


  • Open Access

    Dataset from the dynamic shake-table test of a full-scale unreinforced clay-masonry building with flexible timber diaphragms

    by Stylianos Kallioras, Gabriele Guerrini, Umberto Tomassetti, Simone Peloso, Francesco Graziotti


  • Evaluation of the Seismic Response of Precast Wall Connections: Experimental Observations and Numerical Modeling

    by E. Brunesi, R. Nascimbene, S. Peloso

    This research work is aimed at studying the seismic behavior of a lightly reinforced precast concrete wall system that is typical in northern European regions characterized by little or no natural seismicity. To this end, the authors tested pseudostatically, under in-plane cyclic loads, six full-scale panels representative of those commonly used for low- to mid-rise precast residential multi-unit terraced buildings in the Groningen region. Damage mechanisms and hysteretic capacity curves of wall assemblies with and without openings in their layout are presented so as to examine the seismic performance of these panels and their connections at progressively increased drift amplitudes. All specimens collapsed by a premature shear failure of their panel-to-panel joints, demonstrating that this type of connection is the weakest link of the wall system tested. The paper also discusses the main trends observed in terms of stiffness degradation and energy dissipation with the number of applied cycles and the imposed drift level. Furthermore, the authors carried out an additional set of push-pull tests of four panel subassemblies with variable wall thickness, with a view to specifically investigate the seismic response of this type of joint under asymmetric out-of-plane loading. Test results show that this type of connection system is characterized by visible pinching and low energy dissipation capacity. Based on this large campaign of experimental tests, a simple and computationally efficient numerical model is proposed for large scale seismic fragility analysis of precast terraced structures built with this particular technology.