SRSlobodan Ranković

Slobodan Ranković

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Slobodan Ranković has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Numerical and Experimental Study of Continuous Beams Made of Self-Compacting Concrete Strengthened by GFRP Materials

    by Žarko Petrović, Andrija Zorić, Bojan Milošević, Slobodan Ranković, Predrag Petronijević

    This paper presents an experimental and numerical investigation of continuous reinforced concrete (RC) beams made of self-compacting concrete (SCC) strengthened with fiber-reinforced polymer (FRP) bars using the Near-Surface Mounted (NSM) method. While the majority of previous studies have focused on simply supported beams, this work examines two-span continuous beams, which are more representative of real structural behavior. Four SCC beams were tested under static loading to evaluate the influence of the FRP reinforcement position on flexural capacity and deformational characteristics. The beams were strengthened using glass FRP (GFRP) bars embedded in epoxy adhesive within pre-cut grooves in the concrete cover. Experimental results showed that FRP reinforcement significantly increased the ultimate load capacity, while excessive reinforcement reduced ductility, leading to a more brittle failure mode. A three-dimensional finite element model was developed in Abaqus/Standard using the Concrete Damage Plasticity (CDP) model to simulate the nonlinear behavior of concrete and the bond–slip interaction at the epoxy–concrete interface. The numerical predictions closely matched the experimental load–deflection responses, with a maximum deviation of less than 3%. The validated model provides a reliable tool for parametric analysis and can serve as a reference for optimizing the design of continuous SCC beams strengthened by the NSM FRP method.


  • ULOGA PREGLEDA GRAĐEVINSKIH KONSTRUKCIJA U SISTEMU ODRŽAVANJA – TEHNIČKI I ZAKONODAVNI ASPEKTI

    by Andrija Zorić, Predrag Petronijević, Slobodan Ranković

    Trajnost i pouzdanost konstrukcija imaju veliki značaj za bezbednost korisnika objekta. Tokom vremena dolazi do degradacije konstrukcijskih elemenata, zbog čega je neophodno periodično sprovođenje pregleda i ocene stanja konstrukcija. Na osnovu utvrđenog stanja preduzimaju se mere za očuvanje tehničkih svojstava i sigurnu eksploataciju objekta. U radu su prikazane osnovne zakonske odredbe koje se odnose na pregled i ocenu stanja građevinskih konstrukcija. Kroz studije slučaja analizirani su najčešći uzroci oštećenja konstrukcijskih elemenata i njihov uticaj na nosivost i stabilnost konstrukcija. Kao glavni problemi izdvajaju se nedostatak projektno-tehničke dokumentacije i dejstvo vode i atmosferilija usled neadekvatnog održavanja objekata.

  • TESTING OF SPORT EQUIPMENT – SUSPENDET BASKETBALL BACKSTOP BY TRIAL LOAD

    by Slobodan Ranković, Andrija Zorić, Branko Ranković, Mladen Milinković, 11000 Belgrade Milinković Company

    The paper presents the results of testing a sports equipment structure (suspended basketball backstop) using trial loading. The structure was examined under the influence of static and dynamic loads in accordance with the standard SRPS U.M1.047, and following a testing protocol developed in line with the standard for playground equipment – basketball equipment (SRPS EN 1270). The tests on the foldable structure of the suspended backstop were conducted on an actual (installed) structure mounted in a sports hall in Kraljevo. During the trial loading, measurements of global deformations (deflections) and local deformations (strains) of the tested structure were carried out.

  • Open Access

    Comprehensive Analysis of Ferrocement-Strengthened Reinforced Concrete Beam

    by Darko Živković, Predrag Blagojević, Danijel Kukaras, Radovan Cvetković, Slobodan Ranković

    Starting with the premise that the choice of the optimal method for strengthening reinforced concrete (RC) structures is a complex task and that ferrocement strengthening is comparable to other advanced strengthening technologies due to its cost-effectiveness, ease of construction, and durability, this paper presents a comparative study of the flexural bearing capacity of RC beams strengthened with ferrocement strips applied by gluing. An overview of the life cycle assessment (LCA) based on embodied energy or CO2 is presented in the introduction, based on the existing literature review. The research includes tests of 15 RC beams of identical cross-sections (150/250 mm) and a span of 3000 mm. Strengthening was conducted by applying four types of ferrocement strips (different widths and wire mesh layers). Two factors were examined: the verification of the comprehensive FEM numerical model against the experimental results and the applicability of existing simplified calculation methods for sufficiently accurate results which could be used in regular practice. The results show that the failure forces obtained from numerical models and experimental models differ by no more than 3.94%. The increase in the bearing capacity of the strengthened models is up to 21.4%. The transformed area method for the cracked section showed good results when compared to the FEM and experimental models. The analytically calculated failure force is contingent upon the partial factor for variable action, which was explored within the 1.5–1.7 range.


  • ASSESSMENT OF THE RAILWAY BRIDGE CONDITION AFTER DISLOCATION

    by Slobodan Ranković, Mihajlo Tošić, Miloš Zlatković, Branko Ranković

    The paper presents the results of testing the railway bridge under the influence of trial loads, before and after its dislocation. Basic mechanical characteristics were investigated under static and dynamic loading. Global deformations (deflections) and local deformations (dilation – stress) were measured at both locations under the same trial load for comparison with values and comparison with calculated quantities. Two locomotives of different weights were used as trial loads. It was concluded that the displacement did not cause the bridge to lose the necessary characteristics in terms of load-bearing capacity and usability

  • Open Access

    Strengthening of reinforced concrete beam elements using rod-form composite materials

    by Slobodan Rankovic, Radomir Folic, Marina Mijalkovic, Zarko Petrovic

    The paper emphasizes the advantages of using FRP (fiber reinforced polymer) materials for strengthening reinforced concrete structures. The results of experimental research on the effects of strengthened reinforced concrete beam elements exposed mainly to bending using FRP rod-shaped elements are presented. The load disposition (experimental setup) was in accordance with the "four point load" scheme, and the measurements were made using modern measuring techniques. The results regarding the increase in the bearing capacity of strengthened beams using the NSM (near surface mounting) and EB (externally bounding) methods were compared. In particular, the loaddeflection ratio until failure was analyzed, as well as the change in stiffness depending on the load level. It has been shown that the load capacity of beams strengthened with carbon fiber rods (NSM CFRP) increases by 89%, and the load capacity of beams strengthened with glass fiber rods (NSM GFRP) by 73%. The bearing capacity of beams strengthened with EB CFRP laminates increases by 51%. The ductility of strengthened beams was analyzed and it was shown that it is higher when using GFRP rod-shaped elements (DI=6.5) compared to CFRP rods (DI=5.3). The ductility of the beams strengthened by the EB CFRP method was not satisfactory (DI=2.6).

  • Open Access

    Experimental Analysis of Mechanical Behavior of Timber-Concrete Composite Beams with Different Connecting Systems

    by Radovan Cvetković, Slobodan Ranković, Tatjana Kočetov Mišulić, Danijel Kukaras

    Timber-concrete composite structures are innovative structural systems which have become the subject of extensive research and practical usage, primarily due to their attractive mechanical properties. This article deals with the experimental procedure and the analysis of the mechanical behavior of two different series of timber-concrete composite beams with the same span and geometry of cross-sections. In the first BF-series, the screws were used as a connecting system between the timber and concrete parts, whereas in the BN-series the combination of notches and screws, as a more complex system, was used for the same purpose. Both series were exposed to loading up to a failure by means of the standard four-point bending test. The mechanical behavior of the BF and BN-series beams was analyzed by a comparative analysis referring to: the correlation of the failure loading and the deflection, mechanisms of failure, the strain development across the height of mid-span’s and support’s cross-sections, the horizontal displacement in the timber-concrete interlayer at the support zones, the value of shear stresses and the calculated values of the effective bending stiffness of the beams. The differences in bearing capacity between both series of beams were negligible (about 5%), the effective bending stiffness of BF beams is lower for 32.86% compared to the BN-series and the average value of deflections in BF-series beams is twice as high than in the BN-series. The BN-series beams showed better mechanical behavior in aspects of development of shear stresses in support zones, exhibiting lower shear stress values with an average of 40%.


  • Open Access

    Numerical Analysis of an Innovative Double-Strap Joint for the Splicing of Near-Surface Mounted Fiber-Reinforced Polymer Bars for Reinforced Concrete Beam Strengthening

    by Slobodan Ranković, Andrija Zorić, Todor Vacev, Žarko Petrović

    The issue of the cut-off splicing of an additional fiber-reinforced polymer (FRP) bar in the near-surface mounted (NSM) technique for reinforced concrete (RC) beam strengthening exposed dominantly to bending is insufficiently investigated. A possible solution of this issue is a new proposed technique: a double-strap joint. It implies the widening of the groove at the cut-off location and the symmetrical installing of additional supplements of FRP reinforcement. In this research, beam strength has been determined for the following cases: additional NSM FRP reinforcement without a cut-off, with a cut-off, and without overlapping, and with different lengths of splice overlapping. A nonlinear analysis based on the finite element method (FEM) has been applied. The length of the cut-off splice of the additional FRP reinforcement with glass fibers (GFRP) was 20Ø, 40Ø, and 60Ø. The validation of the numerical model and a comparison of the results were conducted by using the authors’ experiments. It has been shown that, in the case of a cut-off of NSM GFRP bars, a significant loss in strengthening efficiency occurs, and that, with an increase in the overlapping length, this loss decreases. An overlapping length of 60Ø provides full strengthening. An efficiency assessment was carried out via the use of a parametric study, varying the FRP bar material type and its diameter for a constant splicing length.


  • Open Access

    Experimentally Based Analysis of Mechanical Behaviour of Timber-Concrete Composite Beams with Different Connecting Systems

    by Radovan Cvetkovic, Slobodan Ranković, Tatjana Kočetov Mišulić, Danijel Kukaras

    Composite timber-concrete constructions are innovative structural systems which have become the subject of research and practical usage, primarily due to their attractive mechanical properties. This article deals with the experimental procedure and the analysis of the mechanical behavior of two different serious of timber-concrete composite beams. In the composite beams of the A series, screws were used as a fastening system in the interlayer between the timber and concrete parts, whereas in the B type series, a more complex system, the combination of notches and screws, was used for the same purpose. Both series were exposed to loading up to a fracture point by the means of the standard procedure (four point bending test). The mechanical behavior of the A and B-series beams was analyzed by a comparative analysis referring to: the correlation of the fracture loading and the deflection at the moment of fracture, forms and mechanisms of fracture, the development of dilatations at certain points of specific cross-sections, the displacement in the timber-concrete interlayer in the support zones, the value of shear stresses and the calculated values of the effective bending stiffness of the beams. The B-series beams where a more complex fastening system, as it was expected, showed a better mechanical behavior than the A-series beams.


  • Open Access

    Experimental Analysis of an Innovative Double Strap Joint Splicing of GFRP Bars by NSM Methods for Strengthening RC Beams

    by Slobodan Ranković, Radomir Folić, Andrija Zorić, Todor Vacev, Žarko Petrović, Dušan Kovačević

    The double strap joint splicing of glass fiber reinforced polymer (GFRP) bars for reinforced concrete (RC) beams strengthening, applying the near surface mounting (NSM) method, has been proposed in the paper. The proposed method consists of application of the supplementary GFRP bars symmetrically positioned in the cut-off zone of the main GFRP reinforcement. The performances of this splicing method have been experimentally tested for the most unfavorable case of the GFRP reinforcement cut-off in the maximal bending moment zones. During the experiment, the varied parameter has been overlapping length of the bars, taking values of 20∅ and 40∅. Evaluation of the splicing technique is done comparing the experimental results with the results of the behavior of beams strengthened by GFRP bars without cut-off and with cut-off, but without splicing. Experimental research encompassed analysis of strength, stiffness, ductility, crack pattern, strains in the steel, GFRP reinforcement and concrete, and the failure modes of the beams. It has been shown that in case of the cut-off of the GFRP bar, strengthening effectivity decreases for 39%, and that in the case of bypassing the cut-off using double strap 20∅ and 40∅ long, strengthening effectivity decreased 23%, and 14% respectively, compared to the beam without GFRP bar cut-off. Using extrapolation, it has been shown that double strap with length of 60∅ provided strength equivalent to the case without cut-off. The result of application of this splicing method of the additional GFRP bars is significant increase of strength and serviceability of the strengthened RC beams.