David Robinowitz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
David Robinowitz has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Priya Ramaswamy
Department of Anesthesia and Perioperative Care, University of California, San Francisco, San Francisco, CA, USA
2 shared publications - Aalap C. Shah
UCI Univ Calif Irvine Hlth, Anesthesiol & Perioperat Med, Orange, CA 92697 USA
1 shared publication - Amalia Aleck
Department of Anesthesiology, University of California, San Diego, San Diego, CA, United States
1 shared publication - Andrew Bishara
Department of Anesthesia, University of California San Francisco, San Francisco, California, USA
1 shared publication - Anne Shapiro
Department of Anesthesiology, University of California, San Diego, San Diego, CA, United States
1 shared publication - Carly Deibler
San Francisco Medical Center, University of California, San Francisco, CA, United States
1 shared publication
Latest Publications
- 26 November 2025
- Published by Massachusetts Medical Society in NEJM AI
- Vol. 2 (12)
AI-Guided Surgical Blood Readiness: Overcoming Real-World Challenges in Prospective Validation for Safer, More Efficient Blood Preparation
Current preoperative blood ordering relies on outdated, procedure-based maximum surgical blood order schedule (MSBOS) that overlook individual patient risk. Smart Match, a machine-learning (ML) tool that predicts patient-specific transfusion needs, was developed and silently validated. Integrated into real-time workflows, Smart Match demonstrates the potential of ML to replace MSBOS with personalized, data-driven approaches to perioperative blood management. Using 82 variables and 1921 features from the electronic medical record of a tertiary academic medical center, a custom extreme gradient boosting (XGBoost) model was optimized to predict perioperative red blood cell (RBC) transfusions before performing adult elective surgeries, aligning sensitivity with native MSBOS thresholds. The retrospective cohort was split into training, validation, and test sets. Silent prospective validation was conducted in real-world elective cases, comparing Smart Match predictions with both MSBOS and clinician RBC preordering behaviors at multiple time points preceding surgery. Model discrimination, calibration, and clinical utility were assessed. In addition, a hybrid model to estimate daily blood bank needs was developed. Retrospective data consisted of 235,054 cases with a 3.04% (95% confidence interval [CI], 2.97 to 3.11) transfusion rate. The model predictors included medical history, laboratory results, demographics, surgery information, medications, transfusion history, and MSBOS recommendations. The test data achieved an area under the receiver-operating-characteristic curve (AUROC) of 0.94 (95% CI, 0.93 to 0.95) and an area under the precision–recall curve (AUPRC) of 0.57 (95% CI, 0.53 to 0.61). Silent prospective validation (n=24,003, transfusion rate 2.18%, 95% CI, 2.07 to 2.46) maintained a 0.94 (95% CI, 0.92 to 0.95) AUROC and a 0.55 (95% CI, 0.51 to 0.60) AUPRC. Prospectively, the model’s sensitivity was 0.72 (95% CI, 0.67 to 0.75) and its positive predictive value was 0.34 (95% CI, 0.31 to 0.37), surpassing both MSBOS and clinician behavior. Our hybrid model outperformed MSBOS for daily RBC needs with a mean absolute error of 12.86 (95% CI, 11.86 to 13.84) versus 13.34 (95% CI, 12.14 to 14.51) on the test set. Smart Match reliably outperforms MSBOS and clinician orders, works in real time, and will next be assessed through a randomized control trial to gauge its usability and clinical impact. (Funded by the National Institute of General Medical Sciences and others.)
- 26 November 2025
- Published by Massachusetts Medical Society in NEJM AI
- Vol. 2 (12)
AI-Guided Surgical Blood Readiness: Overcoming Real-World Challenges in Prospective Validation for Safer, More Efficient Blood Preparation
Current preoperative blood ordering relies on outdated, procedure-based maximum surgical blood order schedule (MSBOS) that overlook individual patient risk. Smart Match, a machine-learning (ML) tool that predicts patient-specific transfusion needs, was developed and silently validated. Integrated into real-time workflows, Smart Match demonstrates the potential of ML to replace MSBOS with personalized, data-driven approaches to perioperative blood management. Using 82 variables and 1921 features from the electronic medical record of a tertiary academic medical center, a custom extreme gradient boosting (XGBoost) model was optimized to predict perioperative red blood cell (RBC) transfusions before performing adult elective surgeries, aligning sensitivity with native MSBOS thresholds. The retrospective cohort was split into training, validation, and test sets. Silent prospective validation was conducted in real-world elective cases, comparing Smart Match predictions with both MSBOS and clinician RBC preordering behaviors at multiple time points preceding surgery. Model discrimination, calibration, and clinical utility were assessed. In addition, a hybrid model to estimate daily blood bank needs was developed. Retrospective data consisted of 235,054 cases with a 3.04% (95% confidence interval [CI], 2.97 to 3.11) transfusion rate. The model predictors included medical history, laboratory results, demographics, surgery information, medications, transfusion history, and MSBOS recommendations. The test data achieved an area under the receiver-operating-characteristic curve (AUROC) of 0.94 (95% CI, 0.93 to 0.95) and an area under the precision–recall curve (AUPRC) of 0.57 (95% CI, 0.53 to 0.61). Silent prospective validation (n=24,003, transfusion rate 2.18%, 95% CI, 2.07 to 2.46) maintained a 0.94 (95% CI, 0.92 to 0.95) AUROC and a 0.55 (95% CI, 0.51 to 0.60) AUPRC. Prospectively, the model’s sensitivity was 0.72 (95% CI, 0.67 to 0.75) and its positive predictive value was 0.34 (95% CI, 0.31 to 0.37), surpassing both MSBOS and clinician behavior. Our hybrid model outperformed MSBOS for daily RBC needs with a mean absolute error of 12.86 (95% CI, 11.86 to 13.84) versus 13.34 (95% CI, 12.14 to 14.51) on the test set. Smart Match reliably outperforms MSBOS and clinician orders, works in real time, and will next be assessed through a randomized control trial to gauge its usability and clinical impact. (Funded by the National Institute of General Medical Sciences and others.)
- 26 May 2023
- Published by Springer Nature
- p. 19-98
Physiology and Development of the Term and Preterm Neonate
- 26 May 2023
- Published by Springer Nature
- p. 19-98
Physiology and Development of the Term and Preterm Neonate
- Open Access
- 8 December 2022
- Published by JMIR Publications Inc. in JMIR Perioperative Medicine
- Vol. 5 (1) , e40831
An Accessible Clinical Decision Support System to Curtail Anesthetic Greenhouse Gases in a Large Health Network: Implementation Study
Background: Inhaled anesthetics in the operating room are potent greenhouse gases and are a key contributor to carbon emissions from health care facilities. Real-time clinical decision support (CDS) systems lower anesthetic gas waste by prompting anesthesia professionals to reduce fresh gas flow (FGF) when a set threshold is exceeded. However, previous CDS systems have relied on proprietary or highly customized anesthesia information management systems, significantly reducing other institutions’ accessibility to the technology and thus limiting overall environmental benefit. Objective: In 2018, a CDS system that lowers anesthetic gas waste using methods that can be easily adopted by other institutions was developed at the University of California San Francisco (UCSF). This study aims to facilitate wider uptake of our CDS system and further reduce gas waste by describing the implementation of the FGF CDS toolkit at UCSF and the subsequent implementation at other medical campuses within the University of California Health network. Methods: We developed a noninterruptive active CDS system to alert anesthesia professionals when FGF rates exceeded 0.7 L per minute for common volatile anesthetics. The implementation process at UCSF was documented and assembled into an informational toolkit to aid in the integration of the CDS system at other health care institutions. Before implementation, presentation-based education initiatives were used to disseminate information regarding the safety of low FGF use and its relationship to environmental sustainability. Our FGF CDS toolkit consisted of 4 main components for implementation: sustainability-focused education of anesthesia professionals, hardware integration of the CDS technology, software build of the CDS system, and data reporting of measured outcomes. Results: The FGF CDS system was successfully deployed at 5 University of California Health network campuses. Four of the institutions are independent from the institution that created the CDS system. The CDS system was deployed at each facility using the FGF CDS toolkit, which describes the main components of the technology and implementation. Each campus made modifications to the CDS tool to best suit their institution, emphasizing the versatility and adoptability of the technology and implementation framework. Conclusions: It has previously been shown that the FGF CDS system reduces anesthetic gas waste, leading to environmental and fiscal benefits. Here, we demonstrate that the CDS system can be transferred to other medical facilities using our toolkit for implementation, making the technology and associated benefits globally accessible to advance mitigation of health care–related emissions.
- 8 December 2022
- Published by JMIR Publications Inc. in JMIR Perioperative Medicine
- Vol. 5 (1) , e40831
Open AccessAn Accessible Clinical Decision Support System to Curtail Anesthetic Greenhouse Gases in a Large Health Network: Implementation Study
Background: Inhaled anesthetics in the operating room are potent greenhouse gases and are a key contributor to carbon emissions from health care facilities. Real-time clinical decision support (CDS) systems lower anesthetic gas waste by prompting anesthesia professionals to reduce fresh gas flow (FGF) when a set threshold is exceeded. However, previous CDS systems have relied on proprietary or highly customized anesthesia information management systems, significantly reducing other institutions’ accessibility to the technology and thus limiting overall environmental benefit. Objective: In 2018, a CDS system that lowers anesthetic gas waste using methods that can be easily adopted by other institutions was developed at the University of California San Francisco (UCSF). This study aims to facilitate wider uptake of our CDS system and further reduce gas waste by describing the implementation of the FGF CDS toolkit at UCSF and the subsequent implementation at other medical campuses within the University of California Health network. Methods: We developed a noninterruptive active CDS system to alert anesthesia professionals when FGF rates exceeded 0.7 L per minute for common volatile anesthetics. The implementation process at UCSF was documented and assembled into an informational toolkit to aid in the integration of the CDS system at other health care institutions. Before implementation, presentation-based education initiatives were used to disseminate information regarding the safety of low FGF use and its relationship to environmental sustainability. Our FGF CDS toolkit consisted of 4 main components for implementation: sustainability-focused education of anesthesia professionals, hardware integration of the CDS technology, software build of the CDS system, and data reporting of measured outcomes. Results: The FGF CDS system was successfully deployed at 5 University of California Health network campuses. Four of the institutions are independent from the institution that created the CDS system. The CDS system was deployed at each facility using the FGF CDS toolkit, which describes the main components of the technology and implementation. Each campus made modifications to the CDS tool to best suit their institution, emphasizing the versatility and adoptability of the technology and implementation framework. Conclusions: It has previously been shown that the FGF CDS system reduces anesthetic gas waste, leading to environmental and fiscal benefits. Here, we demonstrate that the CDS system can be transferred to other medical facilities using our toolkit for implementation, making the technology and associated benefits globally accessible to advance mitigation of health care–related emissions.
- 30 October 2020
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 134 (1) , 61-71
Aerosol Retention Characteristics of Barrier Devices
Background: Disease severity in coronavirus disease 2019 (COVID-19) may be associated with inoculation dose. This has triggered interest in intubation barrier devices to block droplet exposure; however, aerosol protection with these devices is not known. This study hypothesized that barrier devices reduce aerosol outside of the barrier. Methods: Aerosol containment in closed, semiclosed, semiopen, and open barrier devices was investigated: (1) “glove box” sealed with gloves and caudal drape, (2) “drape tent” with a drape placed over a frame, (3) “slit box” with armholes and caudal end covered by vinyl slit diaphragms, (4) original “aerosol box,” (5) collapsible “interlocking box,” (6) “simple drape” over the patient, and (7) “no barrier.” Containment was investigated by (1) vapor instillation at manikin’s right arm with video-assisted visual evaluation and (2) submicrometer ammonium sulfate aerosol particles ejected through the manikin’s mouth with ventilation and coughs. Samples were taken from standardized locations inside and around the barriers using a particle counter and a mass spectrometer. Aerosol evacuation from the devices was measured using standard hospital suction, a surgical smoke evacuator, and a Shop-Vac. Results: Vapor experiments demonstrated leakage via arm holes and edges. Only closed and semiclosed devices and the aerosol box reduced aerosol particle counts (median [25th, 75th percentile]) at the operator’s mouth compared to no barrier (combined median 29 [−11, 56], n = 5 vs. 157 [151, 166], n = 5). The other barrier devices provided less reduction in particle counts (133 [128, 137], n = 5). Aerosol evacuation to baseline required 15 min with standard suction and the Shop-Vac and 5 min with a smoke evacuator. Conclusions: Barrier devices may reduce exposure to droplets and aerosol. With meticulous tucking, the glove box and drape tent can retain aerosol during airway management. Devices that are not fully enclosed may direct aerosol toward the laryngoscopist. Aerosol evacuation reduces aerosol content inside fully enclosed devices. Barrier devices must be used in conjunction with body-worn personal protective equipment. Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New:
- 30 October 2020
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 134 (1) , 61-71
Aerosol Retention Characteristics of Barrier Devices
Background: Disease severity in coronavirus disease 2019 (COVID-19) may be associated with inoculation dose. This has triggered interest in intubation barrier devices to block droplet exposure; however, aerosol protection with these devices is not known. This study hypothesized that barrier devices reduce aerosol outside of the barrier. Methods: Aerosol containment in closed, semiclosed, semiopen, and open barrier devices was investigated: (1) “glove box” sealed with gloves and caudal drape, (2) “drape tent” with a drape placed over a frame, (3) “slit box” with armholes and caudal end covered by vinyl slit diaphragms, (4) original “aerosol box,” (5) collapsible “interlocking box,” (6) “simple drape” over the patient, and (7) “no barrier.” Containment was investigated by (1) vapor instillation at manikin’s right arm with video-assisted visual evaluation and (2) submicrometer ammonium sulfate aerosol particles ejected through the manikin’s mouth with ventilation and coughs. Samples were taken from standardized locations inside and around the barriers using a particle counter and a mass spectrometer. Aerosol evacuation from the devices was measured using standard hospital suction, a surgical smoke evacuator, and a Shop-Vac. Results: Vapor experiments demonstrated leakage via arm holes and edges. Only closed and semiclosed devices and the aerosol box reduced aerosol particle counts (median [25th, 75th percentile]) at the operator’s mouth compared to no barrier (combined median 29 [−11, 56], n = 5 vs. 157 [151, 166], n = 5). The other barrier devices provided less reduction in particle counts (133 [128, 137], n = 5). Aerosol evacuation to baseline required 15 min with standard suction and the Shop-Vac and 5 min with a smoke evacuator. Conclusions: Barrier devices may reduce exposure to droplets and aerosol. With meticulous tucking, the glove box and drape tent can retain aerosol during airway management. Devices that are not fully enclosed may direct aerosol toward the laryngoscopist. Aerosol evacuation reduces aerosol content inside fully enclosed devices. Barrier devices must be used in conjunction with body-worn personal protective equipment. Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New: