Fuhao Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fuhao Yu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Jianzhong Zhang
Taiyuan University of Technology
2 shared publications - Mingjiang Zhang
Taiyuan University of Technology
2 shared publications - Jian Li
Key Laboratory of Advanced Transducers and Intelligent Control Systems (Ministry of Education and Shanxi Province), Taiyuan University of Technology, Taiyuan 030024, China
1 shared publication - Jian Li
College of Physics and Optoelectronics, Taiyuan University of Technology, Taiyuan, China
1 shared publication - Jiang Qian
R&D Department, State Grid Shanxi Electric Power Company, Yuncheng 032099, China
1 shared publication - Le Zhao
Key Laboratory of Advanced Transducers and Intelligent Control Systems (Ministry of Education and Shanxi Province), Taiyuan University of Technology, Taiyuan 030024, China
1 shared publication
Latest Publications
- Open Access
Conductor Temperature Monitoring of High-Voltage Cables Based on Electromagnetic-Thermal Coupling Temperature Analysis
As a key state parameter of high-voltage cables, conductor temperature is an essential determinant of the current carrying capacity of cables, but in practice, this is difficult to measure directly during the operation of high-voltage cables. In this paper, the electromagnetic-thermal coupling analysis model of a 110 kV high-voltage cable is established using the finite element analysis software COMSOL. By analyzing the temperature distribution law of high-voltage cables under different load currents and ambient temperatures, the relationship between the change in the high-voltage cable surface temperature and the conductor temperature is deduced, which allows the monitoring of the high-voltage cable conductor temperature. Taking the 110 kV cable of the Yanzhong line in Shanxi Province as an example and using the electromagnetic-thermal coupling temperature field analysis method, the conductor temperature of the high-voltage cable can be measured using the data obtained from the cable surface temperature, which is measured by the self-developed Raman Distributed Temperature Sensor (RDTS) system with a maximum measurement error of about 2 °C. The method is easy to use and can achieve the accurate measurement of the conductor temperature without damaging the cable body.
Open AccessConductor Temperature Monitoring of High-Voltage Cables Based on Electromagnetic-Thermal Coupling Temperature Analysis
As a key state parameter of high-voltage cables, conductor temperature is an essential determinant of the current carrying capacity of cables, but in practice, this is difficult to measure directly during the operation of high-voltage cables. In this paper, the electromagnetic-thermal coupling analysis model of a 110 kV high-voltage cable is established using the finite element analysis software COMSOL. By analyzing the temperature distribution law of high-voltage cables under different load currents and ambient temperatures, the relationship between the change in the high-voltage cable surface temperature and the conductor temperature is deduced, which allows the monitoring of the high-voltage cable conductor temperature. Taking the 110 kV cable of the Yanzhong line in Shanxi Province as an example and using the electromagnetic-thermal coupling temperature field analysis method, the conductor temperature of the high-voltage cable can be measured using the data obtained from the cable surface temperature, which is measured by the self-developed Raman Distributed Temperature Sensor (RDTS) system with a maximum measurement error of about 2 °C. The method is easy to use and can achieve the accurate measurement of the conductor temperature without damaging the cable body.
- Open Access
Temperature Resolution Improvement in Raman-Based Fiber-Optic Distributed Sensor Using Dynamic Difference Attenuation Recognition
There is an optical interference noise in the conventional Raman-based fiber-optics distributed sensing, which results in a poor temperature resolution performance. In addition, the traditional whole-fiber demodulation principle complicates the operation steps of the system. In this paper, a novel dynamic difference attenuation recognition (DDAR) principle is operated in the DDP scheme (dual demodulation principle) and the SDP scheme (self-demodulation principle) respectively. It not only helps to eliminate the optical interference noise, but also omits the whole-fiber calibration process. In this experiment, a temperature resolution of 0.30 °C (17.0 km) is achieved through using the DDP scheme based on the DDAR principle, and the measurement time can be shortened to 1.5 s. Meanwhile, a temperature resolution of 0.18 °C (17.0 km) is obtained for the SDP scheme under the DDAR principle. The SNR of DDP and DSP schemes can be optimized to 12.82 dB and 13.32 dB by the proposed DDAR technology. Furthermore, the temperature resolution performance under a large temperature measurement range (0–1000 °C) is theoretically analyzed. The results indicate that the temperature responsivity for DDP and SDP schemes are parabolic and linear type respectively, which causes the temperature resolution of the two schemes to show a different trend with the change of temperature. The proposed DDAR method also can improve the temperature resolution in such a large temperature measurement range.
Open AccessTemperature Resolution Improvement in Raman-Based Fiber-Optic Distributed Sensor Using Dynamic Difference Attenuation Recognition
There is an optical interference noise in the conventional Raman-based fiber-optics distributed sensing, which results in a poor temperature resolution performance. In addition, the traditional whole-fiber demodulation principle complicates the operation steps of the system. In this paper, a novel dynamic difference attenuation recognition (DDAR) principle is operated in the DDP scheme (dual demodulation principle) and the SDP scheme (self-demodulation principle) respectively. It not only helps to eliminate the optical interference noise, but also omits the whole-fiber calibration process. In this experiment, a temperature resolution of 0.30 °C (17.0 km) is achieved through using the DDP scheme based on the DDAR principle, and the measurement time can be shortened to 1.5 s. Meanwhile, a temperature resolution of 0.18 °C (17.0 km) is obtained for the SDP scheme under the DDAR principle. The SNR of DDP and DSP schemes can be optimized to 12.82 dB and 13.32 dB by the proposed DDAR technology. Furthermore, the temperature resolution performance under a large temperature measurement range (0–1000 °C) is theoretically analyzed. The results indicate that the temperature responsivity for DDP and SDP schemes are parabolic and linear type respectively, which causes the temperature resolution of the two schemes to show a different trend with the change of temperature. The proposed DDAR method also can improve the temperature resolution in such a large temperature measurement range.