Stefan Radke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stefan Radke has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Christian G. Pfeifer
Clinic of Trauma Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany
1 shared publication - Florian Baumann
Department of Trauma, Regensburg University Medical Center, 93053 Regensburg, Germany
1 shared publication - Markus Rupp
Department of Trauma, Hand and Reconstructive Surgery, University Hospital Giessen, Justus Liebig University of Giessen, 35385 Giessen, Germany
1 shared publication - Michael Worlicek
Department of Trauma Surgery
1 shared publication - Stephan Deckelmann
Department of Orthopaedic Surgery, Rotkreuzklinikum Munich, Munich, Germany
1 shared publication - Viola Freigang
Department of Trauma, Regensburg University Medical Center, 93053 Regensburg, Germany
1 shared publication
Latest Publications
- Open Access
- 24 November 2020
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21 (1) , 1-9
Patient-reported outcome after patient-specific unicondylar knee arthroplasty for unicompartmental knee osteoarthritis
Background: Unicondylar knee arthroplasty was introduced in the late 1960s and remains a topic of controversial discussion. Patient-specific instruments and patient-specific implants are not yet the standard of care. The question remains whether this time-consuming and costly technique can be beneficial for the patient. The aim of this study was to evaluate whether a custom-made unicondylar knee arthroplasty leads to improved patient-reported outcome.Methods: This retrospective study evaluates the patient-reported outcome after custom-made unicondylar knee arthroplasty (CM-UKA, ConforMIS™ iUni® G2, ConforMIS Inc., Billerica, MA, USA). We evaluated 29 patients (31 knees) at an average of 2.4 years (range 1.2–3.6 years) after operation for unicondylar osteoarthritis of the knee. The target zone for the postoperative leg axis was a slight under-correction of 0–2° varus. Follow-up evaluation included the Forgotten Joint Score (FJS), the Knee Society Score (KSS), a Visual Analogue Scale (VAS) and a radiographic evaluation including a long-leg radiograph. Primary outcome measure was patient satisfaction based on the Forgotten Joint Score.Results: We found an excellent postoperative health-related quality of life with a mean FJS of 76.8 (SD 17.9) indicating a low level of joint awareness after CM-UKA. The mean preoperative KSS was 66.0 (SD 13.71) and 59.4 (17.9) for the KSS function score. The increase was 22.8 points for the KSS knee score (p < 0.0001) and 34.8 points for the KSS function score (p < 0.0001). The VAS for pain decreased from a mean of 5.4 (SD 1.8) to 1.1 (SD 1.2) (p < 0.0001). The malalignment rate with a postoperative deviation of more than 2° in the leg axis was 29%. There was no evidence of component loosening after a mean follow-up of 2.4 years.Conclusions: Custom-made unicondylar knee arthroplasty (CM-UKA) can provide improved clinical and functional outcomes for patients with isolated knee osteoarthritis of the medial compartment. We found excellent results regarding patient satisfaction and a low malalignment rate for CM-UKA. Further studies are needed to investigate long-term survivorship of the implant.Level of evidence: Level IV.Trial registration: Trial Registration number:Z-2014-0389-10Regensburg Clinical Studies Center (REGCSC) 09/07/2014.
- 24 November 2020
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21 (1) , 1-9
Open AccessPatient-reported outcome after patient-specific unicondylar knee arthroplasty for unicompartmental knee osteoarthritis
Background: Unicondylar knee arthroplasty was introduced in the late 1960s and remains a topic of controversial discussion. Patient-specific instruments and patient-specific implants are not yet the standard of care. The question remains whether this time-consuming and costly technique can be beneficial for the patient. The aim of this study was to evaluate whether a custom-made unicondylar knee arthroplasty leads to improved patient-reported outcome.Methods: This retrospective study evaluates the patient-reported outcome after custom-made unicondylar knee arthroplasty (CM-UKA, ConforMIS™ iUni® G2, ConforMIS Inc., Billerica, MA, USA). We evaluated 29 patients (31 knees) at an average of 2.4 years (range 1.2–3.6 years) after operation for unicondylar osteoarthritis of the knee. The target zone for the postoperative leg axis was a slight under-correction of 0–2° varus. Follow-up evaluation included the Forgotten Joint Score (FJS), the Knee Society Score (KSS), a Visual Analogue Scale (VAS) and a radiographic evaluation including a long-leg radiograph. Primary outcome measure was patient satisfaction based on the Forgotten Joint Score.Results: We found an excellent postoperative health-related quality of life with a mean FJS of 76.8 (SD 17.9) indicating a low level of joint awareness after CM-UKA. The mean preoperative KSS was 66.0 (SD 13.71) and 59.4 (17.9) for the KSS function score. The increase was 22.8 points for the KSS knee score (p < 0.0001) and 34.8 points for the KSS function score (p < 0.0001). The VAS for pain decreased from a mean of 5.4 (SD 1.8) to 1.1 (SD 1.2) (p < 0.0001). The malalignment rate with a postoperative deviation of more than 2° in the leg axis was 29%. There was no evidence of component loosening after a mean follow-up of 2.4 years.Conclusions: Custom-made unicondylar knee arthroplasty (CM-UKA) can provide improved clinical and functional outcomes for patients with isolated knee osteoarthritis of the medial compartment. We found excellent results regarding patient satisfaction and a low malalignment rate for CM-UKA. Further studies are needed to investigate long-term survivorship of the implant.Level of evidence: Level IV.Trial registration: Trial Registration number:Z-2014-0389-10Regensburg Clinical Studies Center (REGCSC) 09/07/2014.