Philipp Kolb
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Philipp Kolb has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Tobias Junginger
TRIUMF 4004 Wesbrook Mall V6T 2A3 Vancouver BC Canada
3 shared publications R. E. Laxdal
Accelerator Division, TRIUMF, Vancouver, BC, Canada
2 shared publicationsZ. Yao
Accelerator Division, TRIUMF, Vancouver, BC, Canada
2 shared publicationsA. Blackburn
Department of Physics and Astronomy, University of Victoria, Victoria, BC, Canada
1 shared publication- Aisling Fothergill
School of Health Sciences Faculty of Biology Medicine and Health Manchester Academic Health Science Centre The University of Manchester Manchester UK
1 shared publication Arthur Blackburn
University of Victoria Victoria B.C Canada
1 shared publication
Latest Publications
- Open Access
- 3 September 2024
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 27 (9) , 092001
Thermal feedback in coaxial superconducting radio frequency cavities
The surface resistance of superconducting radio frequency (SRF) cavities depends on the strength of the applied rf field. This field dependence is caused by a combination of intrinsic losses and the extrinsic thermal feedback (TFB) effect. To test theories of intrinsic field dependence, the extrinsic part must be compensated for when analyzing experimental data from SRF cavity tests. Performing this compensation requires knowing thermal parameters that describe heat flow in the cavity walls. The relevant thermal parameters have been measured in the case of superfluid helium, below 2.177 K, but no detailed measurements have yet been reported for cooling of niobium surfaces in normal fluid helium baths. Because of this, the impact of TFB on the field dependence at temperatures near 4.2 K is unknown. In the present study, we report measurements of normal fluid helium boiling from niobium surfaces and its dependence on the orientation of the boiling surface and bath temperature. These measurements are used to create a finite-element model of heat transfer in cavities from TRIUMF’s coaxial test program. This tool is then used to compensate for TFB when analyzing a range of datasets from this program. Results are presented showing that TFB has a weak impact for the temperatures of 2.0 and 4.2 K, where SRF cavities are usually operated, but it is an important effect at intermediate temperatures. Published by the American Physical Society 2024
- 3 September 2024
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 27 (9) , 092001
Open AccessThermal feedback in coaxial superconducting radio frequency cavities
The surface resistance of superconducting radio frequency (SRF) cavities depends on the strength of the applied rf field. This field dependence is caused by a combination of intrinsic losses and the extrinsic thermal feedback (TFB) effect. To test theories of intrinsic field dependence, the extrinsic part must be compensated for when analyzing experimental data from SRF cavity tests. Performing this compensation requires knowing thermal parameters that describe heat flow in the cavity walls. The relevant thermal parameters have been measured in the case of superfluid helium, below 2.177 K, but no detailed measurements have yet been reported for cooling of niobium surfaces in normal fluid helium baths. Because of this, the impact of TFB on the field dependence at temperatures near 4.2 K is unknown. In the present study, we report measurements of normal fluid helium boiling from niobium surfaces and its dependence on the orientation of the boiling surface and bath temperature. These measurements are used to create a finite-element model of heat transfer in cavities from TRIUMF’s coaxial test program. This tool is then used to compensate for TFB when analyzing a range of datasets from this program. Results are presented showing that TFB has a weak impact for the temperatures of 2.0 and 4.2 K, where SRF cavities are usually operated, but it is an important effect at intermediate temperatures. Published by the American Physical Society 2024
- Open Access
- 9 October 2023
- Published by Frontiers Media SA in Frontiers in Electronic Materials
- Vol. 3, 1244126
Mid-T heat treatments on BCP’ed coaxial cavities at TRIUMF
Mid-T heat treatments in the range from 250°C to 400°C on superconducting radio-frequency (SRF) cavities have been shown to provide high quality factors that rise with applied rf field strength in high frequency, electro-polished (EP), elliptical cavities operating at 2 K, similar to nitrogen doped cavities. The rise in quality factor is attributed to a decrease in the temperature dependent part of the surface resistance RBCS. Until now, no results have been reported for these new treatments on quarter-wave resonators (QWR) and half-wave resonators (HWR). The TRIUMF multi-mode coaxial cavities are dedicated test cavities that allow frequency and temperature resolved performance characterization of treatments without changing environments, therefore providing an excellent test vehicle to test these new treatments with rf frequencies ranging from 200 to 1,200 MHz. In this paper, performance measurements from both QWR and HWR cavities are reported and their performance compared with four different treatments: baseline, a conventional 120°C low temperature bake for 48 h, and two mid-T bakes at 300°C and 400°C for 3 h. In addition, sample analysis using SEM, EDX and SIMS of witness samples is also shown. It is found that the mid-T bakes are not directly transferable to low frequency cavities. In the fundamental modes of the two test cavities, no performance gain over the baseline treatment nor a decreasing temperature dependent component with rising rf amplitude was observed. At frequencies above 1 GHz and low temperatures, the mid-T bakes show a reduced field dependence of RBCS compared to both the baseline and 120°C treatments.
- 9 October 2023
- Published by Frontiers Media SA in Frontiers in Electronic Materials
- Vol. 3, 1244126
Open AccessMid-T heat treatments on BCP’ed coaxial cavities at TRIUMF
Mid-T heat treatments in the range from 250°C to 400°C on superconducting radio-frequency (SRF) cavities have been shown to provide high quality factors that rise with applied rf field strength in high frequency, electro-polished (EP), elliptical cavities operating at 2 K, similar to nitrogen doped cavities. The rise in quality factor is attributed to a decrease in the temperature dependent part of the surface resistance RBCS. Until now, no results have been reported for these new treatments on quarter-wave resonators (QWR) and half-wave resonators (HWR). The TRIUMF multi-mode coaxial cavities are dedicated test cavities that allow frequency and temperature resolved performance characterization of treatments without changing environments, therefore providing an excellent test vehicle to test these new treatments with rf frequencies ranging from 200 to 1,200 MHz. In this paper, performance measurements from both QWR and HWR cavities are reported and their performance compared with four different treatments: baseline, a conventional 120°C low temperature bake for 48 h, and two mid-T bakes at 300°C and 400°C for 3 h. In addition, sample analysis using SEM, EDX and SIMS of witness samples is also shown. It is found that the mid-T bakes are not directly transferable to low frequency cavities. In the fundamental modes of the two test cavities, no performance gain over the baseline treatment nor a decreasing temperature dependent component with rising rf amplitude was observed. At frequencies above 1 GHz and low temperatures, the mid-T bakes show a reduced field dependence of RBCS compared to both the baseline and 120°C treatments.
- Open Access
Mid-T Heat Treatments on BCPed Coaxial Cavities at TRIUMF
Mid-T heat treatments in the range from 250 to 400 C on superconducting radio-frequency (SRF) cavities have been shown to provide high quality factors that rise with applied rf field strength in high frequency, electro-polished (EP), elliptical cavities operating at 2K, similar to nitrogen doped cavities. The rise in quality factor is attributed to a decrease in the temperature dependent part of the surface resistance $R_{BCS}$. Until now, no results have been reported for these new treatments on quarter-wave resonators (QWR) and half-wave resonators (HWR). The TRIUMF multi-mode coaxial cavities are dedicated test cavities that allow frequency and temperature resolved performance characterization of treatments without changing environments, therefore providing an excellent test vehicle to test these new treatments with rf frequencies ranging from 200 to 1200 MHz. In this paper, performance measurements from both QWR and HWR cavities are reported and their performance compared with four different treatments: baseline, a conventional 120C low temperature bake for 48 hours, and two mid-T bakes at 300 and 400C for 3 hours. In addition, sample analysis using SEM, EDX and SIMS of witness samples is also shown. It is found that the mid-T bakes are not directly transferable to low frequency cavities. In the fundamental modes of the two test cavities, no performance gain over the baseline treatment nor a decreasing temperature dependent component with rising rf amplitude was observed. At frequencies above 1GHz and low temperatures, the mid-T bakes show a reduced field dependence of $R_{BCS}$ compared to both the baseline and 120C treatments.Open AccessMid-T Heat Treatments on BCPed Coaxial Cavities at TRIUMF
Mid-T heat treatments in the range from 250 to 400 C on superconducting radio-frequency (SRF) cavities have been shown to provide high quality factors that rise with applied rf field strength in high frequency, electro-polished (EP), elliptical cavities operating at 2K, similar to nitrogen doped cavities. The rise in quality factor is attributed to a decrease in the temperature dependent part of the surface resistance $R_{BCS}$. Until now, no results have been reported for these new treatments on quarter-wave resonators (QWR) and half-wave resonators (HWR). The TRIUMF multi-mode coaxial cavities are dedicated test cavities that allow frequency and temperature resolved performance characterization of treatments without changing environments, therefore providing an excellent test vehicle to test these new treatments with rf frequencies ranging from 200 to 1200 MHz. In this paper, performance measurements from both QWR and HWR cavities are reported and their performance compared with four different treatments: baseline, a conventional 120C low temperature bake for 48 hours, and two mid-T bakes at 300 and 400C for 3 hours. In addition, sample analysis using SEM, EDX and SIMS of witness samples is also shown. It is found that the mid-T bakes are not directly transferable to low frequency cavities. In the fundamental modes of the two test cavities, no performance gain over the baseline treatment nor a decreasing temperature dependent component with rising rf amplitude was observed. At frequencies above 1GHz and low temperatures, the mid-T bakes show a reduced field dependence of $R_{BCS}$ compared to both the baseline and 120C treatments. - 1 February 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (2) , 023305
A new high parallel-field spectrometer at TRIUMF’s β-NMR facility
A new high field spectrometer has been built to extend the capabilities of the β-detected nuclear magnetic resonance (β-NMR) facility at TRIUMF. This new beamline extension allows β-NMR spectroscopy to be performed with fields up to 200 mT parallel to a sample’s surface (perpendicular to the ion beam), allowing depth-resolved studies of local electromagnetic fields with spin polarized probes at a much higher applied magnetic field than previously available in this configuration. The primary motivation and application is to allow studies of superconducting radio frequency (SRF) materials close to the critical fields of Nb metal, which is extensively used to fabricate SRF cavities. The details of the design considerations and implementation of the ultra-high vacuum (UHV) system, ion optics, and beam diagnostics are presented here. Commissioning of the beamline and spectrometer with radioactive ions are also reported here. Future capabilities and applications in other areas are also described.
- 1 February 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (2) , 023305
A new high parallel-field spectrometer at TRIUMF’s β-NMR facility
A new high field spectrometer has been built to extend the capabilities of the β-detected nuclear magnetic resonance (β-NMR) facility at TRIUMF. This new beamline extension allows β-NMR spectroscopy to be performed with fields up to 200 mT parallel to a sample’s surface (perpendicular to the ion beam), allowing depth-resolved studies of local electromagnetic fields with spin polarized probes at a much higher applied magnetic field than previously available in this configuration. The primary motivation and application is to allow studies of superconducting radio frequency (SRF) materials close to the critical fields of Nb metal, which is extensively used to fabricate SRF cavities. The details of the design considerations and implementation of the ultra-high vacuum (UHV) system, ion optics, and beam diagnostics are presented here. Commissioning of the beamline and spectrometer with radioactive ions are also reported here. Future capabilities and applications in other areas are also described.
- Open Access
- 2 December 2020
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 23 (12) , 122001
Coaxial multimode cavities for fundamental superconducting rf research in an unprecedented parameter space
Recent developments in superconducting radio-frequency (SRF) research have resulted in significant increases of cavity performance. Advances have been made in both reducing rf surface resistance and pushing the readily achievable accelerating gradient by using novel SRF cavity treatments including surface processing, custom heat treatments, and flux expulsion. These developments have been largely driven by specific tests on single-cell elliptical cavities, while TEM cavities have typically been designed and developed as specific to a project application and not as standard test articles that could be replicated across various labs. To address this, two purpose-built research cavities, one quarter-wave and one half-wave resonator, have been designed and built to allow characterization of TEM-mode cavities with standard and novel surface treatments. The cavities are intended as the TEM-mode equivalent to the 1.3 GHz single-cell cavity, which is the essential tool for high-frequency cavity research. Given their coaxial structure, the cavities allow testing at the fundamental mode and higher harmonics, giving unique insight into the role of rf frequency on fundamental loss mechanisms from intrinsic and extrinsic sources. In this paper, the cavities and testing infrastructure are described, and the first performance measurements of both cavities are presented. Temperature-dependent surface resistance data are analyzed to extract both the temperature-dependent and temperature-independent components and their dependence on the rf field and frequency. In particular, the temperature-dependent component was found to be at low fields at 4.2 K and at 2 K, agreeing fairly well with the theoretical model. The growth of the temperature-dependent surface resistance with increasing field amplitude matches both exponential and quadratic growth models fairly well in the examined range. The independent component is determined to be , matching roughly with anomalous losses, while no clear field dependence was determined. In addition, first measurements of a baking treatment and of the external magnetic field sensitivity are presented.- 2 December 2020
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 23 (12) , 122001
Open AccessCoaxial multimode cavities for fundamental superconducting rf research in an unprecedented parameter space
Recent developments in superconducting radio-frequency (SRF) research have resulted in significant increases of cavity performance. Advances have been made in both reducing rf surface resistance and pushing the readily achievable accelerating gradient by using novel SRF cavity treatments including surface processing, custom heat treatments, and flux expulsion. These developments have been largely driven by specific tests on single-cell elliptical cavities, while TEM cavities have typically been designed and developed as specific to a project application and not as standard test articles that could be replicated across various labs. To address this, two purpose-built research cavities, one quarter-wave and one half-wave resonator, have been designed and built to allow characterization of TEM-mode cavities with standard and novel surface treatments. The cavities are intended as the TEM-mode equivalent to the 1.3 GHz single-cell cavity, which is the essential tool for high-frequency cavity research. Given their coaxial structure, the cavities allow testing at the fundamental mode and higher harmonics, giving unique insight into the role of rf frequency on fundamental loss mechanisms from intrinsic and extrinsic sources. In this paper, the cavities and testing infrastructure are described, and the first performance measurements of both cavities are presented. Temperature-dependent surface resistance data are analyzed to extract both the temperature-dependent and temperature-independent components and their dependence on the rf field and frequency. In particular, the temperature-dependent component was found to be at low fields at 4.2 K and at 2 K, agreeing fairly well with the theoretical model. The growth of the temperature-dependent surface resistance with increasing field amplitude matches both exponential and quadratic growth models fairly well in the examined range. The independent component is determined to be , matching roughly with anomalous losses, while no clear field dependence was determined. In addition, first measurements of a baking treatment and of the external magnetic field sensitivity are presented.