Dieter Ries
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dieter Ries has a total of 130 co-authors. Here are the top co-authors by number of shared publications:
- Bernhard Lauss
Paul Scherrer Institut
5 shared publications M. Daum
Paul Scherrer Institute, Villigen, Switzerland
5 shared publicationsK. Kirch
4 shared publications- Estelle Chanel
Laboratory for High Energy Physics and Albert Einstein Center for Fundamental Physics, University of Bern, 3012 Bern, Switzerland
3 shared publications - Florian M. Piegsa
University of Bern
3 shared publications - Georg Bison
Paul Scherrer Institute (PSI)
3 shared publications
Latest Publications
- Open Access
- 6 October 2025
- Published by Springer Nature in The European Physical Journal A
- Vol. 61 (10) , 1-12
Ultra-cold neutron simulation framework for the free neutron lifetime experiment $\tau $SPECTThe precise determination of the free neutron lifetime is of great significance in modern precision physics. This key observable is linked to the mixing of up and down quarks via the Cabibbo-Kobayashi-Maskawa matrix element $$V_{ud}$$ , and the abundance of primordial elements after the Big-Bang Nucleosynthesis. However, the two leading measurement techniques for the neutron lifetime currently yield incompatible results, a discrepancy referred to as the neutron lifetime puzzle. To address the systematic uncertainties arising from neutron interactions with material walls, the $$\tau $$ SPECT experiment employs a fully magnetic trap for ultra-cold neutrons (UCNs). UCNs velocities are extremely low-energy neutrons with typical velocities below $$8\,\text {m/s}$$ , which can be manipulated using magnetic fields, gravity, and suitable material guides, whose surface can reflect them at any angle of incidence. To precisely study and characterize UCN behavior during production, guidance, storage, and detection in $$\tau $$ SPECT, we have developed a dedicated simulation framework. This framework is built upon the externally developed UCN Monte Carlo software package and is enhanced with two companion tools: one for flexible and parametrizable upstream configuration of such that the simulation’s input settings can be adjusted to reproduce the experimental observations. The second package is used for analyzing, visualizing, and animating simulation data. The simulation results align well with experimental data obtained with $$\tau $$ SPECT at the Paul Scherrer Institute and serve as a powerful resource for identifying systematic uncertainties and guiding future improvements to the current experimental setup.- 6 October 2025
- Published by Springer Nature in The European Physical Journal A
- Vol. 61 (10) , 1-12
Open AccessUltra-cold neutron simulation framework for the free neutron lifetime experiment $\tau $SPECTThe precise determination of the free neutron lifetime is of great significance in modern precision physics. This key observable is linked to the mixing of up and down quarks via the Cabibbo-Kobayashi-Maskawa matrix element $$V_{ud}$$ , and the abundance of primordial elements after the Big-Bang Nucleosynthesis. However, the two leading measurement techniques for the neutron lifetime currently yield incompatible results, a discrepancy referred to as the neutron lifetime puzzle. To address the systematic uncertainties arising from neutron interactions with material walls, the $$\tau $$ SPECT experiment employs a fully magnetic trap for ultra-cold neutrons (UCNs). UCNs velocities are extremely low-energy neutrons with typical velocities below $$8\,\text {m/s}$$ , which can be manipulated using magnetic fields, gravity, and suitable material guides, whose surface can reflect them at any angle of incidence. To precisely study and characterize UCN behavior during production, guidance, storage, and detection in $$\tau $$ SPECT, we have developed a dedicated simulation framework. This framework is built upon the externally developed UCN Monte Carlo software package and is enhanced with two companion tools: one for flexible and parametrizable upstream configuration of such that the simulation’s input settings can be adjusted to reproduce the experimental observations. The second package is used for analyzing, visualizing, and animating simulation data. The simulation results align well with experimental data obtained with $$\tau $$ SPECT at the Paul Scherrer Institute and serve as a powerful resource for identifying systematic uncertainties and guiding future improvements to the current experimental setup. - Open Access
- 14 October 2024
- Published by IOP Publishing in Journal of Physics G: Nuclear and Particle Physics
- Vol. 51 (11) , 115103
τSPECT: a spin-flip loaded magnetic ultracold neutron trap for a determination of the neutron lifetime
The confinement of ultracold neutrons (UCNs) in three-dimensional magnetic field gradient or magneto-gravitational traps allows for a measurement of the free neutron lifetime τ n with superior control over loss channels related to UCNs interacting with material surfaces. The most precise measurement τ n has been achieved using a magneto-gravitational trap, in which UCN are prevented from escaping at the top of their trap by gravity. More compact horizontal confinement geometries with variable energy acceptance ranges can be obtained by using steep magnetic field gradients in all spatial directions, generated by combinations of either permanent or (variable) superconducting magnets. In this paper, we present the first successful implementation of a pulsed spin-flip based loading scheme to fill a three-dimensional magnetic trap with externally produced UCN. The measurements with the τSPECT experiment were performed at the pulsed UCN source of the research reactor TRIGA Mainz. The extracted neutron storage time constant of τ = 859(16) s is compatible with the most precise determinations of τ n . We report on detailed, but statistically limited, investigations of major systematic effects influencing the neutron storage time. The statistical limitations are mitigated by the relocation of the experiment to a stronger UCN source.
- 14 October 2024
- Published by IOP Publishing in Journal of Physics G: Nuclear and Particle Physics
- Vol. 51 (11) , 115103
Open AccessτSPECT: a spin-flip loaded magnetic ultracold neutron trap for a determination of the neutron lifetime
The confinement of ultracold neutrons (UCNs) in three-dimensional magnetic field gradient or magneto-gravitational traps allows for a measurement of the free neutron lifetime τ n with superior control over loss channels related to UCNs interacting with material surfaces. The most precise measurement τ n has been achieved using a magneto-gravitational trap, in which UCN are prevented from escaping at the top of their trap by gravity. More compact horizontal confinement geometries with variable energy acceptance ranges can be obtained by using steep magnetic field gradients in all spatial directions, generated by combinations of either permanent or (variable) superconducting magnets. In this paper, we present the first successful implementation of a pulsed spin-flip based loading scheme to fill a three-dimensional magnetic trap with externally produced UCN. The measurements with the τSPECT experiment were performed at the pulsed UCN source of the research reactor TRIGA Mainz. The extracted neutron storage time constant of τ = 859(16) s is compatible with the most precise determinations of τ n . We report on detailed, but statistically limited, investigations of major systematic effects influencing the neutron storage time. The statistical limitations are mitigated by the relocation of the experiment to a stronger UCN source.
- Open Access
- 24 September 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1069
Development of electron detectors for the BRAND experiment
- 24 September 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1069
Open AccessDevelopment of electron detectors for the BRAND experiment
- Open Access
A neutron trigger detector for pulsed reactor neutron sources
A variety of experiments investigating properties of neutrons can be performed at pulsed reactor neutron sources like the research reactor TRIGA Mainz. A typical problem faced by these experiments is the non-availability of a reliable facility-provided trigger signal in coincidence with the neutron production. Here we present the design and implementation of a neutron pulse detector that provides a coincident trigger signal for experimental timing with a relative precision of 4.5 ms.
Open AccessA neutron trigger detector for pulsed reactor neutron sources
A variety of experiments investigating properties of neutrons can be performed at pulsed reactor neutron sources like the research reactor TRIGA Mainz. A typical problem faced by these experiments is the non-availability of a reliable facility-provided trigger signal in coincidence with the neutron production. Here we present the design and implementation of a neutron pulse detector that provides a coincident trigger signal for experimental timing with a relative precision of 4.5 ms.
- Open Access
- 4 November 2022
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 129 (19) , 191801
New Limit on Axionlike Dark Matter Using Cold Neutrons
We report on a search for dark matter axionlike particles (ALPs) using a Ramsey-type apparatus for cold neutrons. A hypothetical ALP-gluon coupling would manifest in a neutron electric dipole moment signal oscillating in time. Twenty-four hours of data have been analyzed in a frequency range from to 1 kHz, and no significant oscillating signal has been found. The usage of present dark-matter models allows one to constrain the coupling of ALPs to gluons in the mass range from to . The best limit of (95% C.L.) is reached in the mass range from to .- 4 November 2022
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 129 (19) , 191801
Open AccessNew Limit on Axionlike Dark Matter Using Cold Neutrons
We report on a search for dark matter axionlike particles (ALPs) using a Ramsey-type apparatus for cold neutrons. A hypothetical ALP-gluon coupling would manifest in a neutron electric dipole moment signal oscillating in time. Twenty-four hours of data have been analyzed in a frequency range from to 1 kHz, and no significant oscillating signal has been found. The usage of present dark-matter models allows one to constrain the coupling of ALPs to gluons in the mass range from to . The best limit of (95% C.L.) is reached in the mass range from to . - Open Access
New Limit on Axion-Like Dark Matter using Cold Neutrons
We report on a search for dark matter axion-like particles (ALPs) using a Ramsey-type apparatus for cold neutrons. A hypothetical ALP-gluon-coupling would manifest in a neutron electric dipole moment signal oscillating in time. Twenty-four hours of data have been analyzed in a frequency range from 23 $\mu$Hz to 1 kHz, and no significant oscillating signal has been found. The usage of present dark-matter models allows to constrain the coupling of ALPs to gluons in the mass range from $10^{-19}$ to $4 \times 10^{-12}$ eV. The best limit of $C_G$/$f_a m_a = 2.7 \times 10^{13}$ GeV$^{-2}$ (95% C.L.) is reached in the mass range from $2 \times 10^{-17}$ to $2 \times 10^{-14}$ eV.Open AccessNew Limit on Axion-Like Dark Matter using Cold Neutrons
We report on a search for dark matter axion-like particles (ALPs) using a Ramsey-type apparatus for cold neutrons. A hypothetical ALP-gluon-coupling would manifest in a neutron electric dipole moment signal oscillating in time. Twenty-four hours of data have been analyzed in a frequency range from 23 $\mu$Hz to 1 kHz, and no significant oscillating signal has been found. The usage of present dark-matter models allows to constrain the coupling of ALPs to gluons in the mass range from $10^{-19}$ to $4 \times 10^{-12}$ eV. The best limit of $C_G$/$f_a m_a = 2.7 \times 10^{13}$ GeV$^{-2}$ (95% C.L.) is reached in the mass range from $2 \times 10^{-17}$ to $2 \times 10^{-14}$ eV. - Open Access
- 21 July 2021
- Published by Springer Nature in The European Physical Journal A
- Vol. 57 (7) , 1
Erratum to: Data blinding for the nEDM experiment at PSI
A Correction to this paper has been published: https://doi.org/10.1140/epja/s10050-021-00456-1
- 21 July 2021
- Published by Springer Nature in The European Physical Journal A
- Vol. 57 (7) , 1
Open AccessErratum to: Data blinding for the nEDM experiment at PSI
A Correction to this paper has been published: https://doi.org/10.1140/epja/s10050-021-00456-1
- Open Access
- 1 January 2021
- Published by Elsevier in Physics Letters B
- Vol. 812
A search for neutron to mirror-neutron oscillations using the nEDM apparatus at PSI
- 1 January 2021
- Published by Elsevier in Physics Letters B
- Vol. 812
Open AccessA search for neutron to mirror-neutron oscillations using the nEDM apparatus at PSI
- 28 April 2017
- Published by American Physical Society (APS) in Physical Review C
- Vol. 95 (4) , 045503
Comparison of ultracold neutron sources for fundamental physics measurements
Ultracold neutrons (UCNs) are key for precision studies of fundamental parameters of the neutron and in searches for new charge-parity-violating processes or exotic interactions beyond the Standard Model of particle physics. The most prominent example is the search for a permanent electric-dipole moment of the neutron (nEDM). We have performed an experimental comparison of the leading UCN sources currently operating. We have used a “standard” UCN storage bottle with a volume of 32 liters, comparable in size to nEDM experiments, which allows us to compare the UCN density available at a given beam port.
- 28 April 2017
- Published by American Physical Society (APS) in Physical Review C
- Vol. 95 (4) , 045503
Comparison of ultracold neutron sources for fundamental physics measurements
Ultracold neutrons (UCNs) are key for precision studies of fundamental parameters of the neutron and in searches for new charge-parity-violating processes or exotic interactions beyond the Standard Model of particle physics. The most prominent example is the search for a permanent electric-dipole moment of the neutron (nEDM). We have performed an experimental comparison of the leading UCN sources currently operating. We have used a “standard” UCN storage bottle with a volume of 32 liters, comparable in size to nEDM experiments, which allows us to compare the UCN density available at a given beam port.