Takashi Ohtsuki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Takashi Ohtsuki has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Hiroshi Matsufuji
College of Bioresource Sciences, Nihon University, Fujisawa, Japan
3 shared publications- Hiroshi Matsufuji
College of Bioresource Sciences, Nihon University, 1866 Kameino, Fujisawa, Kanagawa, Japan
2 shared publications Miyuki Matsushita
Hitachi High-Tech Analysis Corporation, Minato-ku, Japan
2 shared publicationsSatoru Morikawa
Hitachi High-Tech Analysis Corporation, Minato-ku, Japan
2 shared publicationsAika Maniwa
Food Bioscience and Biotechnology, College of Bioresource Sciences, Nihon University
1 shared publicationAkane Yasuda
College of Bioresource Sciences, Nihon University, Fujisawa, Japan
1 shared publication
Latest Publications
- Open Access
- 3 August 2026
- Published by Springer Nature in Journal of Pharmaceutical Health Care and Sciences
- Vol. 12 (1)
Development of a relative molar sensitivity–based HPLC method for quantifying acetaminophen, two beta-lactams, amiodarone, and its metabolite
Background: Therapeutic drug monitoring (TDM) is essential for drugs with narrow therapeutic ranges and high pharmacokinetic variability. However, significant barriers hinder TDM implementation. Outsourcing of testing can delay timely clinical decision-making, with possible delays of up to 1 week. Additionally, management of analyte-specific certified reference material (CRM) presents substantial operational challenges, particularly for unstable compounds. The present study therefore developed and validated a high-performance liquid chromatography (HPLC) method based on relative molar sensitivity (RMS) of stable non-analyte reference materials (carbamazepine and caffeine) to quantify five clinically important analytes—acetaminophen, two beta-lactam antibiotics (cefmetazole and cefazolin), and amiodarone and its active metabolite, N -desethylamiodarone. Methods: RMS values were calculated as the ratio of the analyte and non-analyte reference material calibration curve slopes. CRM solutions were used at 6 to 10 concentrations per analyte. HPLC analysis utilized analyte-specific detection wavelengths in the range 240–275 nm. For validation, control serum samples were spiked at 2 or 3 concentrations per analyte and processed via spin-column solid-phase extraction. Quantitative accuracy was assessed by comparing the RMS-based results with conventional absolute calibration methods. Results: All calibration curves demonstrated excellent linearity, with correlation coefficients in the range 0.9993–1.0000. Calibration curve slope reproducibility was high, with relative standard deviations of 0.3%–1.5% ( n = 3). Quantitative analyses of spiked serum samples showed close agreement between the RMS and conventional methods, with relative differences not exceeding ± 0.50% for either calibrant for any analyte. Both methods achieved comparable precision, with relative standard deviations of < 4.6%. Conclusions: The validated RMS-based HPLC method provides accurate and precise quantification of structurally diverse drugs using stable, the International System of Units (SI)-traceable, non-analyte reference materials. This approach eliminates the need for analyte-specific authentic standards for routine analyses, thus substantially reducing procurement costs and addressing the instability of some analytes. The rapid and accurate analysis enables timely reporting, potentially leading to improved clinical outcomes through expedited in-house TDM implementation in hospital laboratories with limited resources.
- 3 August 2026
- Published by Springer Nature in Journal of Pharmaceutical Health Care and Sciences
- Vol. 12 (1)
Open AccessDevelopment of a relative molar sensitivity–based HPLC method for quantifying acetaminophen, two beta-lactams, amiodarone, and its metabolite
Background: Therapeutic drug monitoring (TDM) is essential for drugs with narrow therapeutic ranges and high pharmacokinetic variability. However, significant barriers hinder TDM implementation. Outsourcing of testing can delay timely clinical decision-making, with possible delays of up to 1 week. Additionally, management of analyte-specific certified reference material (CRM) presents substantial operational challenges, particularly for unstable compounds. The present study therefore developed and validated a high-performance liquid chromatography (HPLC) method based on relative molar sensitivity (RMS) of stable non-analyte reference materials (carbamazepine and caffeine) to quantify five clinically important analytes—acetaminophen, two beta-lactam antibiotics (cefmetazole and cefazolin), and amiodarone and its active metabolite, N -desethylamiodarone. Methods: RMS values were calculated as the ratio of the analyte and non-analyte reference material calibration curve slopes. CRM solutions were used at 6 to 10 concentrations per analyte. HPLC analysis utilized analyte-specific detection wavelengths in the range 240–275 nm. For validation, control serum samples were spiked at 2 or 3 concentrations per analyte and processed via spin-column solid-phase extraction. Quantitative accuracy was assessed by comparing the RMS-based results with conventional absolute calibration methods. Results: All calibration curves demonstrated excellent linearity, with correlation coefficients in the range 0.9993–1.0000. Calibration curve slope reproducibility was high, with relative standard deviations of 0.3%–1.5% ( n = 3). Quantitative analyses of spiked serum samples showed close agreement between the RMS and conventional methods, with relative differences not exceeding ± 0.50% for either calibrant for any analyte. Both methods achieved comparable precision, with relative standard deviations of < 4.6%. Conclusions: The validated RMS-based HPLC method provides accurate and precise quantification of structurally diverse drugs using stable, the International System of Units (SI)-traceable, non-analyte reference materials. This approach eliminates the need for analyte-specific authentic standards for routine analyses, thus substantially reducing procurement costs and addressing the instability of some analytes. The rapid and accurate analysis enables timely reporting, potentially leading to improved clinical outcomes through expedited in-house TDM implementation in hospital laboratories with limited resources.
- Open Access
- 18 June 2026
- Published by Elsevier in Food Chemistry: X
- Vol. 37
Newly designed liquid chromatographic method using relative molar sensitivity based on 1H-qNMR for quantifying polymethoxyflavones from Kaempferia parviflora
- 18 June 2026
- Published by Elsevier in Food Chemistry: X
- Vol. 37
Open AccessNewly designed liquid chromatographic method using relative molar sensitivity based on 1H-qNMR for quantifying polymethoxyflavones from Kaempferia parviflora
- 22 October 2025
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 109 (3) , 406-414
Development of 1H qNMR Analytical Procedure for Purity Determination of Imazosulfuron and 1,4-BTMSB- d 4 for ISO 17034 Accreditation
Background: Quantitative NMR spectroscopy (qNMR) can be used to determine chemical purity. This applies to the resonating nuclei of all the present chemical species, enabling quantitation of the analyte against chemically nonidentical calibrator molecules. Objective: Validation approaches for determining chemical purity with qNMR are being endorsed by major pharmacopoeias and other standard-setting bodies. In this study, we investigated the purity determination, uncertainty evaluation, and method validation of imazosulfuron using qNMR to gain ISO 17034 accreditation. Methods: We ensured the NIST traceability of imazosulfuron by calibrating 1,4-BTMSB-d4 (determining its purity and uncertainty) using NIST PS 1 and then calibrating imazosulfuron using the calibrated 1,4-BTMSB-d4. Purity and uncertainty determinations were performed using qNMR, as per the proposed revisions to the USP General Chapters and . Method development and validation were performed as described in these chapters using the principles of Analytical Quality by Design (AQbD). Results: First, we defined a target measurement uncertainty of ±2.0% (k = 2) as the Analytical Target Profile (ATP). Next, we established robust operating parameters for qNMR and determined the purity and uncertainty of 1,4-BTMSB-d4. Subsequently, we determined the purity and uncertainty of imazosulfuron using the calibrated 1,4-BTMSB-d4 to verify that the qNMR method produced reportable values that met the ATP criteria. Conclusions: The purity and uncertainty of imazosulfuron were 98.2% ± 1.2% (k = 2), meeting the ATP criteria. We then moved on to the next stage to monitor and ensure that the qNMR method remains properly controlled and to satisfy the ATP criteria during routine use. Based on the above, we established a validation scheme that meets the requirements of ISO 17034 by leveraging AQbD considerations. Highlights: The AQbD principles shift the focus of method validation toward procedure design and development, resulting in more rational design, efficient development, and validation.
- 22 October 2025
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 109 (3) , 406-414
Development of 1H qNMR Analytical Procedure for Purity Determination of Imazosulfuron and 1,4-BTMSB- d 4 for ISO 17034 Accreditation
Background: Quantitative NMR spectroscopy (qNMR) can be used to determine chemical purity. This applies to the resonating nuclei of all the present chemical species, enabling quantitation of the analyte against chemically nonidentical calibrator molecules. Objective: Validation approaches for determining chemical purity with qNMR are being endorsed by major pharmacopoeias and other standard-setting bodies. In this study, we investigated the purity determination, uncertainty evaluation, and method validation of imazosulfuron using qNMR to gain ISO 17034 accreditation. Methods: We ensured the NIST traceability of imazosulfuron by calibrating 1,4-BTMSB-d4 (determining its purity and uncertainty) using NIST PS 1 and then calibrating imazosulfuron using the calibrated 1,4-BTMSB-d4. Purity and uncertainty determinations were performed using qNMR, as per the proposed revisions to the USP General Chapters and . Method development and validation were performed as described in these chapters using the principles of Analytical Quality by Design (AQbD). Results: First, we defined a target measurement uncertainty of ±2.0% (k = 2) as the Analytical Target Profile (ATP). Next, we established robust operating parameters for qNMR and determined the purity and uncertainty of 1,4-BTMSB-d4. Subsequently, we determined the purity and uncertainty of imazosulfuron using the calibrated 1,4-BTMSB-d4 to verify that the qNMR method produced reportable values that met the ATP criteria. Conclusions: The purity and uncertainty of imazosulfuron were 98.2% ± 1.2% (k = 2), meeting the ATP criteria. We then moved on to the next stage to monitor and ensure that the qNMR method remains properly controlled and to satisfy the ATP criteria during routine use. Based on the above, we established a validation scheme that meets the requirements of ISO 17034 by leveraging AQbD considerations. Highlights: The AQbD principles shift the focus of method validation toward procedure design and development, resulting in more rational design, efficient development, and validation.
- Open Access
- 5 July 2024
- Published by Springer Nature in Journal of Pharmaceutical Health Care and Sciences
- Vol. 10 (1) , 1-9
Development of an HPLC method using relative molar sensitivity for the measurement of blood concentrations of nine pharmaceutical compounds
We developed a reliable high-performance liquid chromatographic analysis method using a relative molar sensitivity (RMS) technique that does not require an authentic, identical reference analyte material to quantify blood serum carbamazepine, phenytoin, voriconazole, lamotrigine, meropenem, mycophenolic acid, linezolid, vancomycin, and caffeine levels for routine blood concentration measurements. Carbamazepine and caffeine were also used as non-analyte reference materials to calculate the RMS of each analyte. The RMS was calculated from the ratio of the slope of the calibration equation (analyte/non-analyte reference material), then used to quantify analytes in control serum samples spiked with carbamazepine, phenytoin, voriconazole, meropenem, mycophenolic acid, linezolid or vancomycin. In addition, the concentrations of these six drugs in control serum samples determined by the proposed RMS method agreed well with that obtained using a conventional method. The proposed RMS method is a promising tool for the clinical determination of nine drugs, given the accuracy, precision, and efficiency of quantifying these analytes.
- 5 July 2024
- Published by Springer Nature in Journal of Pharmaceutical Health Care and Sciences
- Vol. 10 (1) , 1-9
Open AccessDevelopment of an HPLC method using relative molar sensitivity for the measurement of blood concentrations of nine pharmaceutical compounds
We developed a reliable high-performance liquid chromatographic analysis method using a relative molar sensitivity (RMS) technique that does not require an authentic, identical reference analyte material to quantify blood serum carbamazepine, phenytoin, voriconazole, lamotrigine, meropenem, mycophenolic acid, linezolid, vancomycin, and caffeine levels for routine blood concentration measurements. Carbamazepine and caffeine were also used as non-analyte reference materials to calculate the RMS of each analyte. The RMS was calculated from the ratio of the slope of the calibration equation (analyte/non-analyte reference material), then used to quantify analytes in control serum samples spiked with carbamazepine, phenytoin, voriconazole, meropenem, mycophenolic acid, linezolid or vancomycin. In addition, the concentrations of these six drugs in control serum samples determined by the proposed RMS method agreed well with that obtained using a conventional method. The proposed RMS method is a promising tool for the clinical determination of nine drugs, given the accuracy, precision, and efficiency of quantifying these analytes.
- Open Access
- 1 July 2021
- Published by Pharmaceutical Society of Japan in YAKUGAKU ZASSHI
- Vol. 141 (7) , 961-970
Changes in Test Methods for Internationalization in the Japanese Pharmacopoeia (Part 2): Establishment of a Quantitative Method for Lorazepam Using HPLC Analysis
The Japanese Pharmacopoeia (JP) is an official normative publication that is referred to, for establishing the authenticity and properties and maintaining the quality of pharmaceutics in Japan. Partial amendments are periodically made to these guidelines to keep up with the progress of science and technology, and the international harmonization is revised every 5 years. Thus, “Internationalization of the JP” is one of the more important issues to address for the revision of the JP. For example, the incorporation of the test methods that have been used in other pharmacopeias, such as the United States Pharmacopeia (USP) and the European Pharmacopoeia (EP), into the JP is a useful approach. In light of this, we have recently reported changes in test methods in the 17th JP, “Establishment of a quantitative test method for clonidine hydrochloride from using a potentiometric titration method to using HPLC”. As a part of our ongoing research to change test methods for internationalization, we selected lorazepam. Lorazepam is analyzed using a potentiometric titration method as listed in the 17th JP; however, both the USP and EP use HPLC for quantitative analysis of this drug. In this study, we synthesized the related impurities of lorazepam listed in the USP and the EP and determined their purities using quantitative NMR. The separation conditions of these compounds, including lorazepam, were examined using HPLC and simultaneous analyses were performed. In addition, lorazepam extracted from the tablets was analyzed using conditions similar to those used for the analysis of the related impurities.
- 1 July 2021
- Published by Pharmaceutical Society of Japan in YAKUGAKU ZASSHI
- Vol. 141 (7) , 961-970
Open AccessChanges in Test Methods for Internationalization in the Japanese Pharmacopoeia (Part 2): Establishment of a Quantitative Method for Lorazepam Using HPLC Analysis
The Japanese Pharmacopoeia (JP) is an official normative publication that is referred to, for establishing the authenticity and properties and maintaining the quality of pharmaceutics in Japan. Partial amendments are periodically made to these guidelines to keep up with the progress of science and technology, and the international harmonization is revised every 5 years. Thus, “Internationalization of the JP” is one of the more important issues to address for the revision of the JP. For example, the incorporation of the test methods that have been used in other pharmacopeias, such as the United States Pharmacopeia (USP) and the European Pharmacopoeia (EP), into the JP is a useful approach. In light of this, we have recently reported changes in test methods in the 17th JP, “Establishment of a quantitative test method for clonidine hydrochloride from using a potentiometric titration method to using HPLC”. As a part of our ongoing research to change test methods for internationalization, we selected lorazepam. Lorazepam is analyzed using a potentiometric titration method as listed in the 17th JP; however, both the USP and EP use HPLC for quantitative analysis of this drug. In this study, we synthesized the related impurities of lorazepam listed in the USP and the EP and determined their purities using quantitative NMR. The separation conditions of these compounds, including lorazepam, were examined using HPLC and simultaneous analyses were performed. In addition, lorazepam extracted from the tablets was analyzed using conditions similar to those used for the analysis of the related impurities.
- Open Access
- 3 December 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (12) , e0243175
Development of an HPLC method with relative molar sensitivity based on 1H-qNMR to determine acteoside and pedaliin in dried sesame leaf powders and processed foods
A high-performance liquid chromatography (HPLC) method with relative molar sensitivity (RMS) based on 1H quantitative NMR spectroscopy (1H-qNMR) has been developed for food ingredients such as acteoside (verbascoside) and pedaliin (pedalitin-6-O-glucoside) without requiring authentic and identical standards as the reliable analytical methods. This method is used methyl 4-hydroxybenzoate (MHB) as an alternative reference standard. Each RMS is also calculated from the ratio of each analyte's molar absorption coefficient to that of MHB after correcting the purities of the analytes and reference standard by 1H-qNMR. Therefore, this method can quantify several analytes with metrological traceability to the International System of Units (SI) using the RMS and one alternative reference standard. In this study, the content of acteoside and pedaliin in several samples, such as dried sesame leaf powders and commercially processed foods, can be determined by the proposed RMS method and demonstrated in good agreement that obtained by a conventional method. Moreover, the proposed method yields analytical data with SI-traceability without the need for an authentic and identical analyte standard. Thus, the proposed RMS method is a useful and practical tool for determining acteoside and pedaliin in terms of the accuracy of quantitative values, the routine analysis, and the cost of reagents.
- 3 December 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (12) , e0243175
Open AccessDevelopment of an HPLC method with relative molar sensitivity based on 1H-qNMR to determine acteoside and pedaliin in dried sesame leaf powders and processed foods
A high-performance liquid chromatography (HPLC) method with relative molar sensitivity (RMS) based on 1H quantitative NMR spectroscopy (1H-qNMR) has been developed for food ingredients such as acteoside (verbascoside) and pedaliin (pedalitin-6-O-glucoside) without requiring authentic and identical standards as the reliable analytical methods. This method is used methyl 4-hydroxybenzoate (MHB) as an alternative reference standard. Each RMS is also calculated from the ratio of each analyte's molar absorption coefficient to that of MHB after correcting the purities of the analytes and reference standard by 1H-qNMR. Therefore, this method can quantify several analytes with metrological traceability to the International System of Units (SI) using the RMS and one alternative reference standard. In this study, the content of acteoside and pedaliin in several samples, such as dried sesame leaf powders and commercially processed foods, can be determined by the proposed RMS method and demonstrated in good agreement that obtained by a conventional method. Moreover, the proposed method yields analytical data with SI-traceability without the need for an authentic and identical analyte standard. Thus, the proposed RMS method is a useful and practical tool for determining acteoside and pedaliin in terms of the accuracy of quantitative values, the routine analysis, and the cost of reagents.
- 1 December 2017
- Published by Elsevier in Food Chemistry
- Vol. 237, 733-742
Determination of starting materials, intermediates, and subsidiary colors in the color additive Food Red No. 106 (Sulforhodamine B) using high-performance liquid chromatography
- 1 December 2017
- Published by Elsevier in Food Chemistry
- Vol. 237, 733-742
Determination of starting materials, intermediates, and subsidiary colors in the color additive Food Red No. 106 (Sulforhodamine B) using high-performance liquid chromatography