JRJadwiga Radziejewska

Jadwiga Radziejewska

*This is an algorithmically generated author record based on publicly available information.

Jadwiga Radziejewska has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    ST segment depression in atrioventricular reentrant tachycardia

    by Jakub Szymon Mercik, Marcin Kuniewicz, Jadwiga Radziejewska, Katarzyna Pach, Dorota Zyśko, Jacek Gajek

    ST segment depression in atrioventricular reentrant tachycardia. Background: ST segment deviation is common in patients with narrow QRS complex tachycardia. It mainly concerns young people in whom ischemic backgr...

  • Open Access

    ST-segment depression in atrioventricular nodal reentrant tachycardia: Preliminary results

    by Jakub Mercik, Jadwiga Radziejewska, Katarzyna Pach, Dorota Zyśko, Jacek Gajek

    The ST-segment is part of the electrocardiogram and physiologically, it forms an isoelectric line. The ST-segment depression is often observed in young, healthy people with paroxysmal tachycardia with narrow QRS complexes. In this group of patients, the 'mysterious tachycardia-induced ST-segment depression', 'subendocardial myocardial ischemia' and other not fully understood terms are used to explain this phenomenon. To assess the presence and possible mechanisms of ST-segment depression during atrioventricular nodal reentrant tachycardia (AVNRT) in patients undergoing radiofrequency (RF) ablation of the underlying arrhythmia. The study included 50 patients (35 women and 15 men) aged about 49 years with clinically relevant paroxysmal narrow QRS complex tachycardia. During electrophysiological study (EPS), all patients had measured QRS components - QR, RS and RJ during the tachycardia and during the sinus rhythm. All of the measurements were done in lead V5. There was a statistically significant difference in cycle length during sinus rhythm and tachycardia (707.0 ±137.8 ms compared to 327.5 ±29.1 ms, p = 0.000), the RJ component (0.819 ±0.381 mV compared to 0.878 ±0.376 mV, p = 0.003) and the difference RJ-QR (0.081 ±0.083 mV compared to 0.163 ±0.108 mV, p = 0.000). The differences in RS and QR components during sinus rhythm and tachycardia did not reach the statistical significance. The difference RJ-QR during tachycardia correlated negatively with tachycardia cycle length (R = -0.39, p = 0.0049). The tachycardia cycle length correlated positively with the age of the studied patients (R = 0.28, p = 0.043). In patients with AVNRT, there is a ST-segment depression during the episodes of tachycardia and the degree of this change is related to tachycardia cycle length. The most probable explanation of the ST-segment depression is the overlap of the QRS complex on the preceded T wave. Some intrinsic properties of individual electrocardiogram (ECG) also influence this phenomenon. The ischemic origin of the presented ST-segment change can be excluded.


  • Open Access

    The true nature of P wave dispersion

    by Jacek Marcin Zawadzki, Katarzyna Zimmer, Wojciech Przywara, Dorota Zyśko, Jadwiga Radziejewska, Agnieszka Sławuta, Jacek Gajek

    The electrophysiological activity of the heart is recorded and presented in form of electrocardiography (ECG). In 1998, the concept of P wave dispersion as the risk factor for atrial fibrillation (AF) recurrence was introduced. It was calculated as the difference between the longest and the shortest P wave. To prove that the P wave dispersion is an artifact of low accuracy in P wave measurement. The study included 104 patients (48 women, 56 men), aged 63 ±14 years, undergoing various electrophysiological procedures. The P wave was measured twice - firstly at the paper speed of 50 mm/s, enhancement ×8 (standard - imprecise), and secondly at 200 mm/s, ×64-256 (precise). The imprecise measurement method resulted in different duration of all P wave parameters in comparison with precise measurement. The longest P wave duration (Pmax) measured imprecisely was 105.1 ±22.1, the Pmax measured precisely was 134.0 ±21.3 (p < 0.001). The P dispersion measured imprecisely was 44.1 ±16.8 and the P dispersion measured precisely was 2.8 ±3.4 (p < 0.0001). The correlation between imprecise Pmax and imprecise Pmin was r = 0.664 (p < 0.05). The correlation between imprecise Pmax and imprecise P wave dispersion was r = 0.612 (p < 0.05). The correlation between precise Pmax and Pmin was almost 1.0 (r = 0.987, p < 0.05). The P wave dispersion does not exist. The measurements of the P wave have to be precise to assure the highest scientific and medical sincerity. The highest clinical value is related to the P wave duration.


  • Open Access

    Can the in-hospital mortality rate in patients with ST-elevation myocardial infarctions be lowered any further?

    by Jadwiga Radziejewska, Martek Frączkowski, Agnieszka Sławuta, Bernard Panaszek

    A myocardial infarction is a specific clinical condition characterized by a relatively high acute mortality rate. Earlier reperfusion results in a smaller infarct size and a lower mortality rate. To assess the in-hospital mortality in patients with ST-elevation myocardial infarction (STEMI) regarding patients' characteristics, and the mechanisms behind the deterioration in hemodynamic and clinical status, in order to assess the possibility of preventing this type of death. A group of 106 patients aged 64.5 ±11.3 years was divided into 2 groups: patients who died while hospitalized (group I; n = 5) and patients who survived while hospitalized for STEMI (group II; n = 101). Primary coronary intervention was performed in all individuals, with direct stent implantation in all but 1 patient. In all patients the standard medication was started or continued, depending on the patient's status. The demographic and selected clinical and biochemical parameters were compared between the study groups. The patients in group I were significantly older than the survivors (76.2 ±12.7 compared to 64.0 ±11.0 years; p < 0.05). The group with fatal myocardial infarction had a lower left ventricular ejection fraction (LVEF) (31.7 ±12.8% compared to 60.4 ±11.0%; p < 0.05) and a higher maximal serum troponin level (973.6 ±1121.8 ng/mL compared to 453.2 ±924.2 ng/mL; p < 0.05). Interestingly, among the patients who died, the pain-to-balloon time was significantly shorter than in the myocardial infarction survivors (84 ±48 min compared to 342 ±504 min; p < 0.05). The development of the medical care system has made invasive procedures available, improving outcomes in patients with acute myocardial infarction. This form of treatment is likely optimized to such an extent that any changes in the time before intervention will not substantially improve mortality rates.


  • Open Access

    P wave duration in paroxysmal and persistent atrial fibrillation

    by Malte Unkell, Maxim Marinov, Peter Stephan Wolff, Jadwiga Radziejewska, Jakub Szymon Mercik, Jacek Gajek

    Functional and structural changes in the atrial muscle constitute a substrate for atrial fibrillation (AF). The pathological changes in the left atrium decrease the conduction velocity and result in prolongation of the P wave duration. To assess the duration of the P wave in patients with AF in different clinical presentations of arrhythmia. The study group consisted of 119 patients diagnosed with AF: 57 women and 62 men, aged 65.3 ±9.4 years. There were 65 patients with paroxysmal AF and 54 with persistent AF. In this group, electrical cardioversion was performed. The P wave duration was measured using an electrophysiological system in all leads at a paper speed of 200 mm/s. The patients did not differ in terms of age, gender or comorbidities. The patients with persistent AF had longer P wave duration (159.9 ±22.3 ms compared to 144.6 ±17.2 ms; p < 0.001) and higher glucose concentration (119.4 ±33.4 mg/dL compared to 108.0 ±24.6 mg/dL; p = 0.015). These results were not influenced by the anti-arrhythmic treatment. Persistent AF shows a longer P wave duration than the paroxysmal AF, independent of age, gender and anti-arrhythmic medication. The prolongation of the P wave related to persistent arrhythmia should force physicians to restore the sinus rhythm earlier in order to more successfully maintain it in the long term.