Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Li-Han Lin has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effects of Tapered-Strut Design on Fatigue Life Enhancement of Peripheral Stents

    by Li-Han Lin, Kuang-Lei Ho, Yu-Min Jian, Kuang-Hsing Chiang, Hao-Ming Hsiao

    Peripheral stent could fracture from cyclic loadings as a result of our blood pressures or daily activities. Fatigue performance has therefore become a key issue for peripheral stent design. A simple yet powerful tapered-strut design concept for fatigue life enhancement was investigated. This concept is to move the stress concentration away from the crown and re-distribute the stresses along the strut by narrowing the strut geometry. Finite element analysis was performed to evaluate the stent fatigue performance under various conditions consistent with the current clinical practice. Thirty stent prototypes were manufactured in-house by laser with a series of post-laser treatments, followed by the validation of bench fatigue tests for proof of concept. FEA simulation results show that the fatigue safety factor of the 40% tapered-strut design increased by 4.2 times that of a standard counterpart, which was validated by bench tests with 6.6-times and 5.9-times fatigue enhancement at room temperature and body temperature, respectively. Bench fatigue test results agreed very well with the increasing trend predicted by FEA simulation. The effects of the tapered-strut design were significant and could be considered as an option for fatigue optimization of future stent designs.


  • Open Access

    Detection of Carotid Artery Stenosis Based on Video Motion Analysis for Fast Screening

    by Cheng‐Hsuan Tsai, Ching‐Chang Huang, Hao‐Ming Hsiao, Ming‐Ya Hung, Guan‐Jie Su, Li‐Han Lin, Ying‐Hsien Chen, Mao‐Shin Lin, Chih‐Fan Yeh, Chi‐Sheng Hung, et al.

    Background: Carotid artery stenosis (CAS) is a common cause of ischemic stroke, and the early detection of CAS may improve patient outcomes. Carotid Doppler ultrasound is commonly used to diagnose CAS. However, it is costly and may not be practical for regular screening practice. This article presents a novel noninvasive and noncontact detection technique using video‐based motion analysis (VMA) to extract useful information from subtle pulses on the skin surface to screen for CAS. Methods and Results: We prospectively enrolled 202 patients with prior carotid Doppler ultrasound data. A short 30‐second video clip of the neck was taken using a commercial mobile device and analyzed by VMA with mathematical quantification of the amplitude of skin motion changes in a blinded manner. The first 40 subjects were used to set up the VMA protocol and define cutoff values, and the following 162 subjects were used for validation. Overall, 54% of the 202 subjects had ultrasound‐confirmed CAS. Using receiver operating characteristic curve analysis, the area under the curve of VMA‐derived discrepancy values to differentiate patients with and without CAS was excellent (area under the curve, 0.914 [95% CI, 0.874–0.954]; P <0.01). The best cutoff value of VMA‐derived discrepancy values to screen for CAS was 5.1, with a sensitivity of 87% and a specificity of 87%. The diagnostic accuracy was consistently high in different subject subgroups. Conclusions: A simple and accurate screening technique to quickly screen for CAS using a VMA system is feasible, with acceptable sensitivity and specificity.


  • Open Access

    Novel Blood Clot Retriever for Ischemic Stroke

    by Ming-Ya Hung, Chun-Kai Yang, Jiong-Hong Chen, Li-Han Lin, Hao-Ming Hsiao

    Stroke is the second leading cause of death in the world. Ischemic stroke, caused by the blockage of intracranial arteries, accounts for approximately 80% of strokes. Among this proportion, acute ischemic stroke, usually caused by the sudden formation of blood clots, can cause fatal blockages in arteries. We proposed a unique blood clot retriever for the treatment of acute ischemic stroke, and conducted a series of tasks, including design, computer simulation, prototyping, and bench testing, for the proof of concept. Unlike most blood clot retrievers used today, our novel design deviates from traditional stent-like blood clot retrievers and uses large closed cells, irregular spikes, and strut protrusions to achieve maximum entanglement for better retrieval performance. Experimental results showed that the retrieval rate of our blood clot retriever was 79%, which demonstrated the feasibility of our new design concept.


  • Open Access

    Characterization of a Sandwich PLGA-Gallic Acid-PLGA Coating on Mg Alloy ZK60 for Bioresorbable Coronary Artery Stents

    by Li-Han Lin, Hung-Pang Lee, Ming-Long Yeh

    Absorbable magnesium stents have become alternatives for treating restenosis owing to their better mechanical properties than those of bioabsorbable polymer stents. However, without modification, magnesium alloys cannot provide the proper degradation rate required to match the vascular reform speed. Gallic acid is a phenolic acid with attractive biological functions, including anti-inflammation, promotion of endothelial cell proliferation, and inhibition of smooth muscle cell growth. Thus, in the present work, a small-molecule eluting coating is designed using a sandwich-like configuration with a gallic acid layer enclosed between poly (d,l-lactide-co-glycolide) layers. This coating was deposited on ZK60 substrate, a magnesium alloy that is used to fabricate bioresorbable coronary artery stents. Electrochemical analysis showed that the corrosion rate of the specimen was ~2000 times lower than that of the bare counterpart. The released gallic acid molecules from sandwich coating inhibit oxidation by capturing free radicals, selectively promote the proliferation of endothelial cells, and inhibit smooth muscle cell growth. In a cell migration assay, sandwich coating delayed wound closure in smooth muscle cells. The sandwich coating not only improved the corrosion resistance but also promoted endothelialization, and it thus has great potential for the development of functional vascular stents that prevent late-stent restenosis.