Michael Antivachis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Michael Antivachis has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Johann Walter Kolar
Swiss Federal Institute of Technology (ETH) Zurich
4 shared publications - Dominik Bortis
Power Electronic Systems Laboratory, ETH Zurich, Zurich, Switzerland
3 shared publications - Pascal Samuel Niklaus
Power Electronic Systems Laboratory, ETH Zurich, Zurich, Switzerland
2 shared publications - Dan Wu
Power Electronic Systems Laboratory, Swiss Federal Institute of Technology (ETH) Zrich, Zrich, Switzerland
1 shared publication - David Menzi
Power Electronic Systems Laboratory, ETH Zrich, Zrich, Switzerland
1 shared publication - Davide Cittanti
Dipartimento Energia G. Ferraris Politecnico di Torino, Torino, Italy
1 shared publication
Latest Publications
- 12 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 27.7.1-27.7.4
Application of WBG Power Devices in Future 3-Φ Variable Speed Drive Inverter Systems "How to Handle a Double-Edged Sword"
Latest research results on three-phase wide-bandgap (WBG) inverter systems with full-sinewave output voltage filtering are reported. A new soft-switching modulation scheme for two-level 1200 V SiC inverters is described. Furthermore, a new Figure-of-Merit for determining maximum multi-level (ML) bridge-leg efficiency is defined and low-voltage GaN devices are evaluated considering ML flying capacitor (FC) and multi-cell inverter structures. Finally, new integrated-filter buck-boost current DC-link inverter topologies are discussed.
- 12 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 27.7.1-27.7.4
Application of WBG Power Devices in Future 3-Φ Variable Speed Drive Inverter Systems "How to Handle a Double-Edged Sword"
Latest research results on three-phase wide-bandgap (WBG) inverter systems with full-sinewave output voltage filtering are reported. A new soft-switching modulation scheme for two-level 1200 V SiC inverters is described. Furthermore, a new Figure-of-Merit for determining maximum multi-level (ML) bridge-leg efficiency is defined and low-voltage GaN devices are evaluated considering ML flying capacitor (FC) and multi-cell inverter structures. Finally, new integrated-filter buck-boost current DC-link inverter topologies are discussed.
- 25 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (3) , 3459-3476
Three-Phase Sinusoidal Output Buck-Boost GaN Y-Inverter for Advanced Variable Speed AC Drives
Motor drive systems supplied by a fuel-cell/battery are especially demanding when it comes to the design of the inverter. Besides a high performance (high efficiency ${\eta }$ and power density ${\rho }$ ), the inverter has to cope with the wide dc voltage variation of the fuel-cell/battery that supplies the motor drive. A promising three-phase inverter topology, denoted as Y-voltage source inverter (VSI), is presented in this article. The Y-VSI is a modular three-phase inverter and comprises three identical phase-modules connected to a common star “Y” point. Each phase-module is equivalent to a buck-boost dc/dc converter, which allows the ac output voltages to be higher or lower than the dc input voltage. Thereby, the Y-VSI effectively copes with the wide variation of the fuel-cell/battery voltage. Each phase-module can be operated in a similar fashion to a conventional dc/dc converter, independently of the remaining two phases. Accordingly, a straightforward and simple operation/control of the Y-VSI is possible. In addition, the Y-VSI features an integrated output filter. This allows for continuous/sinusoidal motor voltage waveforms, eliminating the need for an additional filter between the inverter and the motor. This article details the operating principle of the Y-VSI and comparatively evaluates two modulation strategies. In order to validate the proposed concepts, a Y-VSI hardware prototype is assembled within the context of a high-speed motor drive. In the investigated drive system, a fuel-cell supplies the Y-VSI, which in return controls a 280-kr/min 1-kW electric compressor. The Y-VSI hardware prototype is compared against a state-of-the-art hardware prototype, which features two energy conversion stages. It is shown that the Y-VSI is ${\Delta \eta = +2.3 \%}$ more efficient and at the same time ${\Delta \rho = +10 \%}$ more power-dense compared with the conventional inverter solution.
- 25 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (3) , 3459-3476
Three-Phase Sinusoidal Output Buck-Boost GaN Y-Inverter for Advanced Variable Speed AC Drives
Motor drive systems supplied by a fuel-cell/battery are especially demanding when it comes to the design of the inverter. Besides a high performance (high efficiency ${\eta }$ and power density ${\rho }$ ), the inverter has to cope with the wide dc voltage variation of the fuel-cell/battery that supplies the motor drive. A promising three-phase inverter topology, denoted as Y-voltage source inverter (VSI), is presented in this article. The Y-VSI is a modular three-phase inverter and comprises three identical phase-modules connected to a common star “Y” point. Each phase-module is equivalent to a buck-boost dc/dc converter, which allows the ac output voltages to be higher or lower than the dc input voltage. Thereby, the Y-VSI effectively copes with the wide variation of the fuel-cell/battery voltage. Each phase-module can be operated in a similar fashion to a conventional dc/dc converter, independently of the remaining two phases. Accordingly, a straightforward and simple operation/control of the Y-VSI is possible. In addition, the Y-VSI features an integrated output filter. This allows for continuous/sinusoidal motor voltage waveforms, eliminating the need for an additional filter between the inverter and the motor. This article details the operating principle of the Y-VSI and comparatively evaluates two modulation strategies. In order to validate the proposed concepts, a Y-VSI hardware prototype is assembled within the context of a high-speed motor drive. In the investigated drive system, a fuel-cell supplies the Y-VSI, which in return controls a 280-kr/min 1-kW electric compressor. The Y-VSI hardware prototype is compared against a state-of-the-art hardware prototype, which features two energy conversion stages. It is shown that the Y-VSI is ${\Delta \eta = +2.3 \%}$ more efficient and at the same time ${\Delta \rho = +10 \%}$ more power-dense compared with the conventional inverter solution.
- 18 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (4) , 4066-4080
Analysis of the Influence of Measurement Circuit Asymmetries on Three-Phase CM/DM Conducted EMI Separation
EMI conducted emissions are of increasing concern in power electronics given the high switching frequency and fast switching speeds of latest generation wide-bandgap semiconductors. The decomposition of the total conducted EMI noise into its Common-Mode (CM) and Differential-Mode (DM) part by means of a CM/DM noise separator allows for a systematic EMI filter design. Carefully designed realizations achieve a Common-Mode Rejection Ratio (CMRR) and Differential-Mode Rejection Ratio (DMRR) of 50dB at 30MHz. However, a very high performance CM/DM noise separator is not sufficient. It is theoretically analyzed and experimentally proven that asymmetries in the EMI test setup result in an unwanted conversion between CM and DM EMI noise and therefore significantly influence the CM/DM separation. In particular, three main influences are identified: the line impedance stabilization network, the connection cables and the converter EMI filter. The unwanted noise conversion is pronounced for frequencies in the MHz range, where parasitic resonances occur. The impact of asymmetries in the EMI filter is most severe and clearly limits the EMI noise splitting at high frequencies. A high performance noise separator can be used to investigate filter asymmetries and helps to improve the filter design process and facilitates the modeling of EMI noise sources.
- 18 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (4) , 4066-4080
Analysis of the Influence of Measurement Circuit Asymmetries on Three-Phase CM/DM Conducted EMI Separation
EMI conducted emissions are of increasing concern in power electronics given the high switching frequency and fast switching speeds of latest generation wide-bandgap semiconductors. The decomposition of the total conducted EMI noise into its Common-Mode (CM) and Differential-Mode (DM) part by means of a CM/DM noise separator allows for a systematic EMI filter design. Carefully designed realizations achieve a Common-Mode Rejection Ratio (CMRR) and Differential-Mode Rejection Ratio (DMRR) of 50dB at 30MHz. However, a very high performance CM/DM noise separator is not sufficient. It is theoretically analyzed and experimentally proven that asymmetries in the EMI test setup result in an unwanted conversion between CM and DM EMI noise and therefore significantly influence the CM/DM separation. In particular, three main influences are identified: the line impedance stabilization network, the connection cables and the converter EMI filter. The unwanted noise conversion is pronounced for frequencies in the MHz range, where parasitic resonances occur. The impact of asymmetries in the EMI filter is most severe and clearly limits the EMI noise splitting at high frequencies. A high performance noise separator can be used to investigate filter asymmetries and helps to improve the filter design process and facilitates the modeling of EMI noise sources.
- 17 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (3) , 3427-3442
Analysis of Double-Bridge Inverters for Drive Systems With Open-End Winding Motors
The double-bridge voltage source inverter (DB-VSI) is a promising inverter topology for high performing motor drives. A DB-VSI comprises two VSIs, connected to the opposite sides of an open-end winding motor (no floating neutral point). Due to its inherent properties, a DB-VSI requires only half dc supply voltage, compared with a simple VSI, in order to generate the same motor voltage. Thereafter, by processing/switching only half of the dc supply voltage, the DB-VSI benefits from significantly lower semiconductor devices’ switching losses. The DB-VSI technology is the main focus of this article. Namely, two different DB-VSI variants and/or modulation strategies are comparatively evaluated. After detailing the operating principle of each modulation strategy, the stresses on the inverter components are analytically derived. It is shown that the selection of the DB-VSI modulation strategy impacts the efficiency/power density of the inverter and the voltage quality of the motor. The theoretical considerations are subsequently verified within the context of a high-speed motor drive. In the investigated drive system, a fuel-cell supplies the inverter, which in return controls a 280-kr/min 1-kW electric compressor. Two DB-VSI hardware prototypes are purposely assembled and compared against a third state-of-the-art hardware prototype of the same specifications. It is shown that due to the DB-VSI technology, it is possible to reduce simultaneously the volume and the losses by up to 50% compared with the state-of-the-art solution. The low DB-VSI volume enables a seamless integration of the inverter in the motor housing. Accordingly, the open-end winding motor is directly attached to the inverter, eliminating the need for cumbersome and costly interconnecting cables. A final, integrated (inverter/motor) hardware prototype is presented, which further highlights the advantages of DB-VSI technology.
- 17 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (3) , 3427-3442
Analysis of Double-Bridge Inverters for Drive Systems With Open-End Winding Motors
The double-bridge voltage source inverter (DB-VSI) is a promising inverter topology for high performing motor drives. A DB-VSI comprises two VSIs, connected to the opposite sides of an open-end winding motor (no floating neutral point). Due to its inherent properties, a DB-VSI requires only half dc supply voltage, compared with a simple VSI, in order to generate the same motor voltage. Thereafter, by processing/switching only half of the dc supply voltage, the DB-VSI benefits from significantly lower semiconductor devices’ switching losses. The DB-VSI technology is the main focus of this article. Namely, two different DB-VSI variants and/or modulation strategies are comparatively evaluated. After detailing the operating principle of each modulation strategy, the stresses on the inverter components are analytically derived. It is shown that the selection of the DB-VSI modulation strategy impacts the efficiency/power density of the inverter and the voltage quality of the motor. The theoretical considerations are subsequently verified within the context of a high-speed motor drive. In the investigated drive system, a fuel-cell supplies the inverter, which in return controls a 280-kr/min 1-kW electric compressor. Two DB-VSI hardware prototypes are purposely assembled and compared against a third state-of-the-art hardware prototype of the same specifications. It is shown that due to the DB-VSI technology, it is possible to reduce simultaneously the volume and the losses by up to 50% compared with the state-of-the-art solution. The low DB-VSI volume enables a seamless integration of the inverter in the motor housing. Accordingly, the open-end winding motor is directly attached to the inverter, eliminating the need for cumbersome and costly interconnecting cables. A final, integrated (inverter/motor) hardware prototype is presented, which further highlights the advantages of DB-VSI technology.