Joost Walraven
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Joost Walraven has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Beatrice Belletti
Department of Engineering and Architecture, University of Parma, Parco Area delle Scienze 181/A, 43124 Parma, Italy
4 shared publications - Eva Olivia Leontien Lantsoght
Concrete Structures, Department of Engineering Structures, Faculty of Civil Engineering and Geosciences Delft University of Technology Delft The Netherlands
3 shared publications - Ane de Boer
Senior Advisor, Rijkswaterstaat, Ministry of Infrastructure and the Environment, P.O. Box 24057, 3502MB, Utrecht, Netherlands
2 shared publications Cor van der Veen
2 shared publications- Cor van der Veen
Concrete Structures, Delft University of Technology, 2628 CN Delft, The Netherlands
2 shared publications - Rita Esposito
Delft University of Technology
2 shared publications
Latest Publications
- 28 April 2023
- Published by Wiley in Structural Concrete
- Vol. 24 (4) , 4387-4395
Approach to assessment of existing structures in the fib Model Code 2020
Existing structures often no longer meet the demands formulated in contemporary design codes with respect to structural safety and serviceability. This occurs, for instance, if the loads on existing structures, like traffic loads on bridges, are larger than assumed in the original design. A second potential reason is that structures are subject to deterioration, like alkali–silica reaction within the concrete or corrosion of the reinforcement due to chloride attack or carbonation. A third possible reason is that in recent codes, additional criteria have been introduced based on new theories and/or negative experiences with older structures. The new fib Model Code for Concrete Structures 2020 will be valid both for the design of new structures and the assessment of existing structures. This paper shows how the design and assessment of concrete structures are integrated into this new code concept.
- 28 April 2023
- Published by Wiley in Structural Concrete
- Vol. 24 (4) , 4387-4395
Approach to assessment of existing structures in the fib Model Code 2020
Existing structures often no longer meet the demands formulated in contemporary design codes with respect to structural safety and serviceability. This occurs, for instance, if the loads on existing structures, like traffic loads on bridges, are larger than assumed in the original design. A second potential reason is that structures are subject to deterioration, like alkali–silica reaction within the concrete or corrosion of the reinforcement due to chloride attack or carbonation. A third possible reason is that in recent codes, additional criteria have been introduced based on new theories and/or negative experiences with older structures. The new fib Model Code for Concrete Structures 2020 will be valid both for the design of new structures and the assessment of existing structures. This paper shows how the design and assessment of concrete structures are integrated into this new code concept.
- 4 April 2023
- Published by Wiley in Structural Concrete
- Vol. 24 (4) , 4424-4432
Assessment of existing structures in fib modelcode 2020: Solutions and examples
- 4 April 2023
- Published by Wiley in Structural Concrete
- Vol. 24 (4) , 4424-4432
Assessment of existing structures in fib modelcode 2020: Solutions and examples
- Open Access
- 12 January 2022
- Published by Wiley in Structural Concrete
- Vol. 23 (2) , 1018-1035
Self‐compacting high performance fiber concrete for foundations: Part 2—Fiber orientation and distribution
An investigation was executed into the applicability of self‐compacting high performance fiber concrete in foundations. The applied concrete has a concrete cube strength of about 110 MPa and contains 60 kg/m3 hooked‐end steel fibers (LF = 30 mm, DF = 0.38 mm). This publication consists of two parts: (1) Experimental assessment and verification of design rules and (2) assessment of fiber orientation and distribution. In the first part, experiments are described which were carried out to determine the pre‐ and post‐cracking strength properties, the shear resistance of short beams, the anchorage length of rebars, and the shear capacity of foundation slabs supported on piles. The test results were used for a verification and extension of design rules for fiber reinforced concrete (FRC) found in the fib Model Code 2010. The application of the FRC developed can lead to substantial savings in concrete and reinforcing steel. In the present second part, cross‐sections of two slabs and a beam of this testing series have been analyzed with regard to fiber orientation and distribution. An image analysis, executed on 111 concrete areas, indicates that a preferred fiber orientation could not be identified throughout the assessed elements. The data supports the conclusion of a good fiber distribution as well; a strong correlation was obtained for the data set of full images between measured and theoretical relation of fiber orientation and fiber density.
- 12 January 2022
- Published by Wiley in Structural Concrete
- Vol. 23 (2) , 1018-1035
Open AccessSelf‐compacting high performance fiber concrete for foundations: Part 2—Fiber orientation and distribution
An investigation was executed into the applicability of self‐compacting high performance fiber concrete in foundations. The applied concrete has a concrete cube strength of about 110 MPa and contains 60 kg/m3 hooked‐end steel fibers (LF = 30 mm, DF = 0.38 mm). This publication consists of two parts: (1) Experimental assessment and verification of design rules and (2) assessment of fiber orientation and distribution. In the first part, experiments are described which were carried out to determine the pre‐ and post‐cracking strength properties, the shear resistance of short beams, the anchorage length of rebars, and the shear capacity of foundation slabs supported on piles. The test results were used for a verification and extension of design rules for fiber reinforced concrete (FRC) found in the fib Model Code 2010. The application of the FRC developed can lead to substantial savings in concrete and reinforcing steel. In the present second part, cross‐sections of two slabs and a beam of this testing series have been analyzed with regard to fiber orientation and distribution. An image analysis, executed on 111 concrete areas, indicates that a preferred fiber orientation could not be identified throughout the assessed elements. The data supports the conclusion of a good fiber distribution as well; a strong correlation was obtained for the data set of full images between measured and theoretical relation of fiber orientation and fiber density.
- Open Access
- 16 September 2021
- Published by Wiley in Structural Concrete
- Vol. 23 (1) , 172-186
Self‐compacting high‐performance fiber concrete for foundations: Part 1 ‐experimental verification and design considerations
An investigation is carried out into the applicability of self‐compacting high‐performance fiber concrete (HPFC) in foundations. A concrete mixture has been designed with a concrete cube strength of about 110 MPa. The concrete contains 60 kg/m3 steel fibers. The properties of the HPFC developed are very suitable for structural applications, especially because the post‐cracking tensile strength, provided by the fibers, is higher than the axial tensile strength of the concrete so that hardening in tension occurs after crack formation, often characterized by multiple cracking. This not only results in a high bearing capacity but as well in substantial durability. As a potential application foundation elements are considered. Experiments have been carried out to determine the pre‐ and post‐cracking strength properties, the shear resistance of short beams with loads near to the supports, the anchorage length of reinforcing bars, and the shear capacity of pile caps. The results of the tests are used for verification of the applicability of the general design rules for fiber concrete, as found in the fib Model Code 2010, to the HPFC developed. The HPFC developed is characterized by high strength and ductility, is durable and self‐compacting. The research program showed that the design of structures with the HPFC considered can be based on existing design rules with some extensions.
- 16 September 2021
- Published by Wiley in Structural Concrete
- Vol. 23 (1) , 172-186
Open AccessSelf‐compacting high‐performance fiber concrete for foundations: Part 1 ‐experimental verification and design considerations
An investigation is carried out into the applicability of self‐compacting high‐performance fiber concrete (HPFC) in foundations. A concrete mixture has been designed with a concrete cube strength of about 110 MPa. The concrete contains 60 kg/m3 steel fibers. The properties of the HPFC developed are very suitable for structural applications, especially because the post‐cracking tensile strength, provided by the fibers, is higher than the axial tensile strength of the concrete so that hardening in tension occurs after crack formation, often characterized by multiple cracking. This not only results in a high bearing capacity but as well in substantial durability. As a potential application foundation elements are considered. Experiments have been carried out to determine the pre‐ and post‐cracking strength properties, the shear resistance of short beams with loads near to the supports, the anchorage length of reinforcing bars, and the shear capacity of pile caps. The results of the tests are used for verification of the applicability of the general design rules for fiber concrete, as found in the fib Model Code 2010, to the HPFC developed. The HPFC developed is characterized by high strength and ductility, is durable and self‐compacting. The research program showed that the design of structures with the HPFC considered can be based on existing design rules with some extensions.
- Open Access
- 6 December 2020
- Published by Wiley in Structural Concrete
- Vol. 22 (2) , 590-592
Synthesized intervention method to prolong service life of reinforced concrete structures: ICCP‐SS
- 6 December 2020
- Published by Wiley in Structural Concrete
- Vol. 22 (2) , 590-592
Open AccessSynthesized intervention method to prolong service life of reinforced concrete structures: ICCP‐SS
- 1 July 2019
- Published by American Concrete Institute in ACI Structural Journal
- Vol. 116 (4) , 169-181
Punching Shear in Prestressed Concrete Deck Slabs: Parametric Study
- 1 July 2019
- Published by American Concrete Institute in ACI Structural Journal
- Vol. 116 (4) , 169-181
Punching Shear in Prestressed Concrete Deck Slabs: Parametric Study
- 1 January 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 143 (1)
Shear Behavior of Reinforced Concrete Beams without Transverse Reinforcement Based on Critical Shear Displacement
This paper presents a new concept to evaluate the shear capacity of reinforced concrete beams without shear reinforcement having flexural shear failure. Based on experimental observations, it is proposed that the opening of the critical inclined crack can be considered as the lower bound for the shear capacity of a structural member. It is also proposed that the unstable opening of the critical inclined crack is triggered when the shear displacement in an existing flexural crack reaches a critical value . Thus the critical shear displacement is used as a failure criterion, and based on that a new shear evaluation method is proposed. The method shows agreeable accuracy when compared with test results in literature.- 1 January 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 143 (1)
Shear Behavior of Reinforced Concrete Beams without Transverse Reinforcement Based on Critical Shear Displacement
This paper presents a new concept to evaluate the shear capacity of reinforced concrete beams without shear reinforcement having flexural shear failure. Based on experimental observations, it is proposed that the opening of the critical inclined crack can be considered as the lower bound for the shear capacity of a structural member. It is also proposed that the unstable opening of the critical inclined crack is triggered when the shear displacement in an existing flexural crack reaches a critical value . Thus the critical shear displacement is used as a failure criterion, and based on that a new shear evaluation method is proposed. The method shows agreeable accuracy when compared with test results in literature.- 11 May 2016
- Published by Wiley in Beton- und Stahlbetonbau
- Vol. 111 (5) , 288-300
Querkrafttragfähigkeit von Platten nahe Auflagern
- 11 May 2016
- Published by Wiley in Beton- und Stahlbetonbau
- Vol. 111 (5) , 288-300
Querkrafttragfähigkeit von Platten nahe Auflagern
- 1 May 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 21 (5)
Case Study on Aggregate Interlock Capacity for the Shear Assessment of Cracked Reinforced-Concrete Bridge Cross Sections
A 55-year-old bridge showed large cracking in the approach bridge caused by restraint of deformation and support settlement. After repair, it was uncertain at which crack width the traffic loads on the bridge should be further restricted. The shear capacity was calculated by counting on the aggregate interlock capacity of a supposedly fully cracked cross section. An aggregate interlock relationship between shear capacity and crack width based on an unreinforced section was used to find the maximum allowable crack width. Limits for crack widths at which load restrictions should be imposed were found. The large structural capacity of the cracked concrete section shows that the residual bearing resistance based on the aggregate interlock capacity of reinforced concrete slab bridges with existing cracks is higher than expected. This expected capacity could be calculated with the inclined cracking load from the code provisions. The procedure outlined in this paper can thus be used for the shear assess...
- 1 May 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 21 (5)
Case Study on Aggregate Interlock Capacity for the Shear Assessment of Cracked Reinforced-Concrete Bridge Cross Sections
A 55-year-old bridge showed large cracking in the approach bridge caused by restraint of deformation and support settlement. After repair, it was uncertain at which crack width the traffic loads on the bridge should be further restricted. The shear capacity was calculated by counting on the aggregate interlock capacity of a supposedly fully cracked cross section. An aggregate interlock relationship between shear capacity and crack width based on an unreinforced section was used to find the maximum allowable crack width. Limits for crack widths at which load restrictions should be imposed were found. The large structural capacity of the cracked concrete section shows that the residual bearing resistance based on the aggregate interlock capacity of reinforced concrete slab bridges with existing cracks is higher than expected. This expected capacity could be calculated with the inclined cracking load from the code provisions. The procedure outlined in this paper can thus be used for the shear assess...