Venkata Sree Charan Kupp
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Venkata Sree Charan Kupp has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Christoph Rau
Diamond Light Source, Harwell Campus, Didcot, UK
2 shared publicationsDarren Batey
Diamond Light Source, Harwell Campus, Didcot, UK
2 shared publicationsKathryn Dodds
Department of Earth Sciences, University of Cambridge, Cambridge, UK
2 shared publicationsKaz Wanelik
Diamond Light Source, Harwell Campus, Didcot, UK
2 shared publicationsMatthew Ball
Department of Earth Sciences, University of Cambridge, Cambridge, UK
2 shared publicationsRoger Fu
Department of Earth and Planetary Sciences, Harvard University, Cambridge, USA
2 shared publications
Latest Publications
- Open Access
- 25 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-13
Investigating the limits of hard X-ray coherence length measurement employing Young’s double slit experiment
Young’s double slit experiment has been the most explored technique to gauge a system’s coherence properties. The limits of this technique in characterizing spatial coherence properties of high emittance, hard X-ray synchrotron sources have been performed at the BXDS-IVU beamline, Canadian Light Source (CLS). High emittance synchrotron sources have been assumed to possess sub-optimal coherence properties. While this is largely true, it’s important to understand the limits of coherence for these sources. We demonstrate that the Young’s double slit experiment has harsher limits than what is normally expected. We present data obtained at multiple energies in both spatial directions leading to a thorough understanding of the limitations of employing Young’s double slit experiment to characterize low coherence length systems. We propose a numerical technique to estimate the source size directly from the double slit interference patterns. With these results, we have demonstrated that CLS has functional coherent beam properties in the hard X-ray regime with spatial coherence lengths ranging from 5.37 to 17.61 µm in the horizontal direction. The spatial coherence lengths in the vertical direction were at least 3 times larger. Finally, we present theoretical calculations showcasing the limits of Young’s double slit experiment in characterizing diffraction limited sources.
- 25 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-13
Open AccessInvestigating the limits of hard X-ray coherence length measurement employing Young’s double slit experiment
Young’s double slit experiment has been the most explored technique to gauge a system’s coherence properties. The limits of this technique in characterizing spatial coherence properties of high emittance, hard X-ray synchrotron sources have been performed at the BXDS-IVU beamline, Canadian Light Source (CLS). High emittance synchrotron sources have been assumed to possess sub-optimal coherence properties. While this is largely true, it’s important to understand the limits of coherence for these sources. We demonstrate that the Young’s double slit experiment has harsher limits than what is normally expected. We present data obtained at multiple energies in both spatial directions leading to a thorough understanding of the limitations of employing Young’s double slit experiment to characterize low coherence length systems. We propose a numerical technique to estimate the source size directly from the double slit interference patterns. With these results, we have demonstrated that CLS has functional coherent beam properties in the hard X-ray regime with spatial coherence lengths ranging from 5.37 to 17.61 µm in the horizontal direction. The spatial coherence lengths in the vertical direction were at least 3 times larger. Finally, we present theoretical calculations showcasing the limits of Young’s double slit experiment in characterizing diffraction limited sources.
- Open Access
- 1 March 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-18
Nanoscale imaging of Fe-rich inclusions in single-crystal zircon using X-ray ptycho-tomography
We apply X-ray ptycho-tomography to perform high-resolution, non-destructive, three-dimensional (3D) imaging of Fe-rich inclusions in paleomagnetically relevant materials (zircon single crystals from the Bishop Tuff ignimbrite). Correlative imaging using quantum diamond magnetic microscopy combined with X-ray fluorescence mapping was used to locate regions containing potential ferromagnetic remanence carriers. Ptycho-tomographic reconstructions with voxel sizes 85 nm and 21 nm were achievable across a field-of-view > 80 µm; voxel sizes as small as 5 nm were achievable over a limited field-of-view using local ptycho-tomography. Fe-rich inclusions 300 nm in size were clearly resolved. We estimate that particles as small as 100 nm—approaching single-domain threshold for magnetite—could be resolvable using this “dual-mode” methodology. Fe-rich inclusions (likely magnetite) are closely associated with apatite inclusions that have no visible connection to the exterior surface of the zircon (e.g., via intersecting cracks). There is no evidence of radiation damage, alteration, recrystallisation or deformation in the host zircon or apatite that could provide alternative pathways for Fe infiltration, indicating that magnetite and apatite grew separately as primary phases in the magma, that magnetite adhered to the surfaces of the apatite, and that the magnetite-coated apatite was then encapsulated as primary inclusions within the growing zircon. Rarer examples of Fe-rich inclusions entirely encapsulated by zircon are also observed. These observations support the presence of primary inclusions in relatively young and pristine zircon crystals. Combining magnetic and tomography results we deduce the presence of magnetic carriers that are in the optimal size range for carrying strong and stable paleomagnetic signals but that remain below the detection limits of even the highest-resolution X-ray tomography reconstructions. We recommend the use of focused ion beam nanotomography and/or correlative transmission electron microscopy to directly confirm the presence of primary magnetite in the sub 300 nm range as a necessary step in targeted paleomagnetic workflows.
- 1 March 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-18
Open AccessNanoscale imaging of Fe-rich inclusions in single-crystal zircon using X-ray ptycho-tomography
We apply X-ray ptycho-tomography to perform high-resolution, non-destructive, three-dimensional (3D) imaging of Fe-rich inclusions in paleomagnetically relevant materials (zircon single crystals from the Bishop Tuff ignimbrite). Correlative imaging using quantum diamond magnetic microscopy combined with X-ray fluorescence mapping was used to locate regions containing potential ferromagnetic remanence carriers. Ptycho-tomographic reconstructions with voxel sizes 85 nm and 21 nm were achievable across a field-of-view > 80 µm; voxel sizes as small as 5 nm were achievable over a limited field-of-view using local ptycho-tomography. Fe-rich inclusions 300 nm in size were clearly resolved. We estimate that particles as small as 100 nm—approaching single-domain threshold for magnetite—could be resolvable using this “dual-mode” methodology. Fe-rich inclusions (likely magnetite) are closely associated with apatite inclusions that have no visible connection to the exterior surface of the zircon (e.g., via intersecting cracks). There is no evidence of radiation damage, alteration, recrystallisation or deformation in the host zircon or apatite that could provide alternative pathways for Fe infiltration, indicating that magnetite and apatite grew separately as primary phases in the magma, that magnetite adhered to the surfaces of the apatite, and that the magnetite-coated apatite was then encapsulated as primary inclusions within the growing zircon. Rarer examples of Fe-rich inclusions entirely encapsulated by zircon are also observed. These observations support the presence of primary inclusions in relatively young and pristine zircon crystals. Combining magnetic and tomography results we deduce the presence of magnetic carriers that are in the optimal size range for carrying strong and stable paleomagnetic signals but that remain below the detection limits of even the highest-resolution X-ray tomography reconstructions. We recommend the use of focused ion beam nanotomography and/or correlative transmission electron microscopy to directly confirm the presence of primary magnetite in the sub 300 nm range as a necessary step in targeted paleomagnetic workflows.
- Open Access
- 12 May 2023
- Published by Springer Nature in Research Square
Detection of primary paleomagnetic remanence carriers in zircon crystals using high-resolution X-ray ptycho-tomography
We present the first application of X-ray ptycho-tomography to perform high-resolution, non-destructive, three-dimensional (3D) imaging of magnetic inclusions in paleomagnetically relevant materials (zircon crystals from the Bishop Tuff ignimbrite). Correlative microscopy using quantum diamond magnetic microscopy combined with X-ray fluorescence mapping was used to locate regions containing Fe-bearing magnetic remanence carriers. Ptycho-tomographic reconstructions with voxel sizes 85 nm and 21 nm were achievable across a field-of-view > 80 µm; voxel sizes as small as 5 nm were achievable over a limited field-of-view using local ptycho-tomography. Magnetite particles 300 nm in size were clearly resolved. We estimate that particles as small as 100 nm – approaching single-domain threshold for magnetite – could be resolvable using this “dual-mode” methodology. Our combined magnetic and tomography results support the presence of primary magnetic inclusions in relatively young and pristine zircon crystals, majority of which are in the optimal size range for carrying strong and stable paleomagnetic signals.
- 12 May 2023
- Published by Springer Nature in Research Square
Open AccessDetection of primary paleomagnetic remanence carriers in zircon crystals using high-resolution X-ray ptycho-tomography
We present the first application of X-ray ptycho-tomography to perform high-resolution, non-destructive, three-dimensional (3D) imaging of magnetic inclusions in paleomagnetically relevant materials (zircon crystals from the Bishop Tuff ignimbrite). Correlative microscopy using quantum diamond magnetic microscopy combined with X-ray fluorescence mapping was used to locate regions containing Fe-bearing magnetic remanence carriers. Ptycho-tomographic reconstructions with voxel sizes 85 nm and 21 nm were achievable across a field-of-view > 80 µm; voxel sizes as small as 5 nm were achievable over a limited field-of-view using local ptycho-tomography. Magnetite particles 300 nm in size were clearly resolved. We estimate that particles as small as 100 nm – approaching single-domain threshold for magnetite – could be resolvable using this “dual-mode” methodology. Our combined magnetic and tomography results support the presence of primary magnetic inclusions in relatively young and pristine zircon crystals, majority of which are in the optimal size range for carrying strong and stable paleomagnetic signals.
- Open Access
- 7 December 2020
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 8 (12) , 998
An Improved Cleaning Protocol for Foraminiferal Calcite from Unconsolidated Core Sediments: HyPerCal—A New Practice for Micropaleontological and Paleoclimatic Proxies
Paleoclimatic and paleoceanographic studies routinely rely on the usage of foraminiferal calcite through faunal, morphometric and physico-chemical proxies. The application of such proxies presupposes the extraction and cleaning of these biomineralized components from ocean sediments in the most efficient way, a process which is often labor intensive and time consuming. In this respect, in this study we performed a systematic experiment for planktonic foraminiferal specimen cleaning using different chemical treatments and evaluated the resulting data of a Late Quaternary gravity core sample from the Aegean Sea. All cleaning procedures adopted here were made on the basis of their minimum potential bias upon foraminiferal proxies, such as the faunal assemblages, degree of fragmentation, stable isotope composition (δ18O and δ13C) and/or Mg/Ca ratios that are frequently used as proxies for surface-ocean climate parameters (e.g., sea surface temperature, sea surface salinity). Six different protocols were tested, involving washing, sieving, and chemical treatment of the samples with hydrogen peroxide and/or sodium hexametaphosphate (Calgon®). Single species foraminifera shell weighing was combined with high-resolution scanning electron microscopy (SEM) and synchrotron X-ray microtomography (SμCT) of the material processed by each of the cleaning protocols, in order to assess the decontamination degree of specimen’s ultrastructure and interior. It appeared that a good compromise between time and cleaning efficiency is the simultaneous treatment of samples with a mixed hydrogen peroxide and Calgon solution, while the most effective way to almost completely decontaminate the calcareous components from undesirable sedimentary material is a two-step treatment—initially with hydrogen peroxide and subsequently with Calgon solutions.
- 7 December 2020
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 8 (12) , 998
Open AccessAn Improved Cleaning Protocol for Foraminiferal Calcite from Unconsolidated Core Sediments: HyPerCal—A New Practice for Micropaleontological and Paleoclimatic Proxies
Paleoclimatic and paleoceanographic studies routinely rely on the usage of foraminiferal calcite through faunal, morphometric and physico-chemical proxies. The application of such proxies presupposes the extraction and cleaning of these biomineralized components from ocean sediments in the most efficient way, a process which is often labor intensive and time consuming. In this respect, in this study we performed a systematic experiment for planktonic foraminiferal specimen cleaning using different chemical treatments and evaluated the resulting data of a Late Quaternary gravity core sample from the Aegean Sea. All cleaning procedures adopted here were made on the basis of their minimum potential bias upon foraminiferal proxies, such as the faunal assemblages, degree of fragmentation, stable isotope composition (δ18O and δ13C) and/or Mg/Ca ratios that are frequently used as proxies for surface-ocean climate parameters (e.g., sea surface temperature, sea surface salinity). Six different protocols were tested, involving washing, sieving, and chemical treatment of the samples with hydrogen peroxide and/or sodium hexametaphosphate (Calgon®). Single species foraminifera shell weighing was combined with high-resolution scanning electron microscopy (SEM) and synchrotron X-ray microtomography (SμCT) of the material processed by each of the cleaning protocols, in order to assess the decontamination degree of specimen’s ultrastructure and interior. It appeared that a good compromise between time and cleaning efficiency is the simultaneous treatment of samples with a mixed hydrogen peroxide and Calgon solution, while the most effective way to almost completely decontaminate the calcareous components from undesirable sedimentary material is a two-step treatment—initially with hydrogen peroxide and subsequently with Calgon solutions.