Van Nam Tran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Van Nam Tran has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Etienne Pruvot
Heart and Vessel Department, Service of Cardiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
1 shared publication - Hyun Wook Kang
Pukyong National University
1 shared publication Patrice Carroz
Department of Heart and Vessel, Service of Cardiology, University Hospital of Lausanne (CHUV), Rue du Bugnon 46, CH-1011 Lausanne, Switzerland
1 shared publication- Samuel Rotman
Service of Clinical Pathology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
1 shared publication - Suhyun Park
Department of Electronic and Electrical Engineering, Ewha Womans University, Seoul, South Korea
1 shared publication - Van Gia Truong
Interdisciplinary Program of Marine-Bio, Electrical & Mechanical Engineering, Pukyong National University, Busan, South Korea
1 shared publication
Latest Publications
- Open Access
- 1 December 2020
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 4 (6) , 1-7
Re-entrant ventricular tachycardia as a complication of ablation of idiopathic ventricular premature beats from the right outflow tract: a case report
Background: We report an unusual case of non-sustained ventricular tachycardia (NSVT) from the epicardial part of the right ventricular outflow tract (RVOT). Case summary: A 37-year-old woman who underwent in 2006 an ablation for idiopathic ventricular premature beats (VPBs) from the RVOT presented with pre-syncopal NSVT in 2016. A cardiac workup showed no coronary disease, normal biventricular function, and no enhancement on cardiac magnetic resonance imaging. A metabolic positron emission tomography scan excluded inflammation. Biopsies revealed normal desmosomal proteins. An endocardial mapping revealed an area of low voltage potential (<0.5 mV) at the antero-septal aspect of the RVOT corresponding to the initial site of ablation from 2006. Activation mapping revealed poor prematurity and pace-mapping showed unsatisfactory morphologies in the RVOT, the left ventricle outflow tract and the right coronary cusp. An epicardial map revealed a low voltage area at the antero-septal aspect of the RVOT with fragmented potentials opposite to the endocardial scar. Pace-mapping demonstrated perfect match. An NSVT was induced and local electrocardiogram showed mid-diastolic potentials. Ablation was applied epicardially and endocardially without any complication. The patient was arrhythmia free at 4-year follow-up. Discussion: Cardiac workup allowed to exclude specific conditions such as arrhythmogenic cardiomyopathy, tetralogy of Fallot, sarcoidosis, or myocarditis as a cause for NSVT from the RVOT. The epi and endocardial map showed residual scar subsequent to the first ablation which served as substrate for the re-entrant NSVT. This is the first case which describes NSVT from the epicardial RVOT as a complication from a previous endocardial ablation for idiopathic VPB.
- 1 December 2020
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 4 (6) , 1-7
Open AccessRe-entrant ventricular tachycardia as a complication of ablation of idiopathic ventricular premature beats from the right outflow tract: a case report
Background: We report an unusual case of non-sustained ventricular tachycardia (NSVT) from the epicardial part of the right ventricular outflow tract (RVOT). Case summary: A 37-year-old woman who underwent in 2006 an ablation for idiopathic ventricular premature beats (VPBs) from the RVOT presented with pre-syncopal NSVT in 2016. A cardiac workup showed no coronary disease, normal biventricular function, and no enhancement on cardiac magnetic resonance imaging. A metabolic positron emission tomography scan excluded inflammation. Biopsies revealed normal desmosomal proteins. An endocardial mapping revealed an area of low voltage potential (<0.5 mV) at the antero-septal aspect of the RVOT corresponding to the initial site of ablation from 2006. Activation mapping revealed poor prematurity and pace-mapping showed unsatisfactory morphologies in the RVOT, the left ventricle outflow tract and the right coronary cusp. An epicardial map revealed a low voltage area at the antero-septal aspect of the RVOT with fragmented potentials opposite to the endocardial scar. Pace-mapping demonstrated perfect match. An NSVT was induced and local electrocardiogram showed mid-diastolic potentials. Ablation was applied epicardially and endocardially without any complication. The patient was arrhythmia free at 4-year follow-up. Discussion: Cardiac workup allowed to exclude specific conditions such as arrhythmogenic cardiomyopathy, tetralogy of Fallot, sarcoidosis, or myocarditis as a cause for NSVT from the RVOT. The epi and endocardial map showed residual scar subsequent to the first ablation which served as substrate for the re-entrant NSVT. This is the first case which describes NSVT from the epicardial RVOT as a complication from a previous endocardial ablation for idiopathic VPB.
- Open Access
- 16 November 2017
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 8 (12) , 5663-5674
Spatial effect of conical angle on optical-thermal distribution for circumferential photocoagulation
A uniformly diffusing applicator can be advantageous for laser treatment of tubular tissue. The current study investigated various conical angles for diffuser tips as a critical factor for achieving radially uniform light emission. A customized goniometer was employed to characterize the spatial uniformity of the light propagation. An ex vivo model was developed to quantitatively compare the temperature development and irreversible tissue coagulation. The 10-mm diffuser tip with angle at 25° achieved a uniform longitudinal intensity profile (i.e., 0.90 ± 0.07) as well as a consistent thermal denaturation on the tissue. The proposed conical angle can be instrumental in determining the uniformity of light distribution for the photothermal treatment of tubular tissue.
- 16 November 2017
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 8 (12) , 5663-5674
Open AccessSpatial effect of conical angle on optical-thermal distribution for circumferential photocoagulation
A uniformly diffusing applicator can be advantageous for laser treatment of tubular tissue. The current study investigated various conical angles for diffuser tips as a critical factor for achieving radially uniform light emission. A customized goniometer was employed to characterize the spatial uniformity of the light propagation. An ex vivo model was developed to quantitatively compare the temperature development and irreversible tissue coagulation. The 10-mm diffuser tip with angle at 25° achieved a uniform longitudinal intensity profile (i.e., 0.90 ± 0.07) as well as a consistent thermal denaturation on the tissue. The proposed conical angle can be instrumental in determining the uniformity of light distribution for the photothermal treatment of tubular tissue.