DODenis A. Ogurtsov

Denis A. Ogurtsov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Denis A. Ogurtsov has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Ankle replacement for severe post-traumatic deformation of the distal tibia: a case report

    by G.P. Kotelnikov, A.V. Kolsanov, A.N. Nikolaenko, V.V. Ivanov, D.A. Dolgushkin, A.S. Pankratov, D.O. Ogurtsov, S.O. Doroganov, A.D. Stroikova

    Objective. To evaluate the immediate results of ankle replacement with original prosthesis in a patient with severe post-traumatic deformation of the distal tibia. Material and methods. When developing the original design of ankle prosthesis, we considered foreign analogues of classical and revision models of ankle prostheses taking into account their shortcomings. In this case, an integrated approach was used. Extensive work has been carried out to select materials for prosthetic components. Experimental work with mesenchymal stromal cells of bone marrow was aimed at testing cytotoxicity and biological compatibility. The staff of the department of designing biomechanical structures of the Research Institute of Bionics and Personalized Medicine of the Samara State Medical University carefully studied the proposed design of endoprosthesis using the Ansys software. After cadaver tests on full-scale models, we performed surgical intervention in a patient with severe post-traumatic deformity of the lower third of the left tibia. Results. Our studies revealed convenience and certain advantages of intraoperative installation of original ankle prosthesis. Along with this, this clinical example indicated come features that must be taken into account in revision ankle replacement to avoid possible postoperative consequences. Conclusion. Original ankle prosthesis makes it possible to replace the distal tibia and preserve limb function.


  • Open Access

    Application of 3D modeling in a personalized approach to bone osteosynthesis (A literature review)

    by A. S. Pankratov, Yu. V. Lartsev, A. A. Rubtsov, D. A. Ogurtsov, Yu. D. Kim, A. V. Shmel'KOv, N. A. Knyazev, Ю. В. Ларцев, Никита Алексеевич Князев

    Three-dimensional printing opens up many opportunities for use in traumatology and orthopedics, because it takes into account personal characteristics of the patients. Modern methods of high-resolution medical imaging can process data to create threedimensional images for printing physical objects. Today, three-dimensional printers are able to create a model of any complexity of shape and geometry. The article provides a review of the literature about three-dimensional digital modeling in shaping implants for osteosynthesis. Data search was carried out on the Scopus, Web of Scince, Pubmed, RSCI databases for the period 2012–2022. The effectiveness of three-dimensional printing for preoperative modeling of bone plates has been confirmed: implants perfectly corresponds with the unique anatomy of the patient, since the template for it is based on the materials of computed tomography. Individual templates can be useful when the geometry of patients' bones goes beyond the standard, and when improved results of surgery are expected due to better matching of implants to the anatomical needs of patients.

  • Open Access

    Current trends in the development of long tubular bones osteosynthesis

    by Aleksandr S. Pankratov, Artemii A. Rubtsov, Denis A. Ogurtsov, Yurii D. Kim, Dmitrii S. Shitikov, Andrei V. Shmelkov

    We reviewed scientific literature on the problem of osteosynthesis of long tubular human bones, published during the last 10 years. The Scopus, Web of Scince, Pubmed, RSCI databases were searched for the articles reporting the results of clinical studies and biomechanical experiments using plate osteosynthesis. The advantages and disadvantages of minimally invasive plate osteosynthesis for different segments have been revealed. The articles reported a lower probability of displacement development in minimally invasive plate osteosynthesis in comparison with intramedullary osteosynthesis, good biological conditions for fracture healing, decreased rate of complications of postoperative wounds due to reduced incisions. In the concept of biological osteosynthesis, the advantage of axial dynamization and fracture micro-mobility over absolute rigidity was noted. The study also revealed the influence of the parameters of a plate and osteosynthesis technique on the rigidity of the plate-bone system, such as: the working length of the plate, the number of screws on the plate, types of screws (cortical or locking), the plate material and its profile. The bone osteosynthesis seemed to have new directions of evolution. These include far cortical locking screws allowing micromobility under the plate, providing a "controlled dynamization". An experimental technology of Active Locking Plates has been reported, where the screws with angular stability are locked in holes on elastic sliding elements providing micromobility of the screw relative to the plate. In general, all the visible results differed in various studies and, sometimes, contradicted each other.


  • Open Access

    Treatment of severe planovalgus foot deformity in a child

    by Olga D. Bagdulina, Yurii V. Lartsev, Andrei V. Shmelkov, Aleksandr S. Pankratov, Nikita E. Likholatov, Denis A. Ogurtsov, Ларцев Юрий В.

    Planovalgus foot deformity is one of the most common orthopedic conditions detected in childhood. According to the literature, it is present in 70% of children under 11 years with various degree of severity. Without timely correction, the common complications of this deformity are: arthrosis of the talonavicular joint, valgus deformity of the knee joints, impaired posture and functional scoliosis, pain syndrome, impaired function of the lower extremities, which is an indication for surgical treatment of this pathology. The article presents a clinical case report of surgical treatment of a patient with severe planovalgus foot deformity. The main stages of surgical correction were tendon-muscle plasty, subtalar arthroeresis and Cotton osteotomy (wedging osteotomy of the medial sphenoid bone). Relying on the results of surgical treatment of the patient, we conclude that the use of the combination of methods is valid for the treatment of patients with severe planovalgus foot deformity.

  • Open Access

    Surgical treatment of patients with chronic posttraumatic lateral ankle instability using the Brostrom – Gould procedure

    by Vladimir A. Larionov, Dmitrii S. Shitikov, Yurii D. Kim, Denis A. Ogurtsov, Aleksandr S. Pankratov

    Aim to evaluate the effectiveness of restoring the lateral ankle ligament complex using local tissues according to the Brostrom Gould technique in patients with different post-traumatic periods. Material and methods. In 2021, in total 15 patients with lateral ankle instability underwent clinical and instrumental examination and received surgical treatment for this pathology. The patients were divided into three groups depending on the time passed from the primary injury. Group 1 included patients with a post-traumatic period up to 5 years, Group 2 up to 10 years and Group 3 more than 10 years. The ankle instability was assessed before and after surgery using the AOFAS and Karlsson Peterson scales. Results. In Groups 1 and 2, the patients were satisfied with the results of treatment They could restore the intensity of their physical activity to the level they had before the injury. The patients from Group 3 were not content with the results of treatment and reported the remaining pain, swelling, and joint instability. Conclusion. With a disease duration of up to 5 years, Brostrom Gould procedure provides excellent results and remains the preferred treatment for lateral ankle instability. This technique can be successfully used in patients with the post-injury period up to 10 years, if their life-style does not imply the regular intensive load on the ankle. If the history of the disease is more than 10 years, the Brostrom Gould procedure is ineffective, in such cases other complex treatment methods should be used.


  • A PREOPERATIVE PLANNING METHOD FOR LONG TUBULAR BONE OSTEOSYNTHESIS

    by Samara State Medical University, G.P. Kotelnikov, A.V. Kolsanov, A.S. Pankratov, S.V. Ardatov, D.A. Ogurtsov, P.M. Zelter, A.A. Rubtsov

    Objective. To compare the shape and size of human contralateral humerus bones based on the «Autoplan» program to justify the possibility of using healthy bone in a preoperative planning for bone osteosynthesis (on the example of the humerus). Methods. 20 patients underwent computed tomography of the chest, shoulder girdleand upper extremities. Two-dimensional medical imaging of separate layers were converted into three-dimensional models of the humerus bone STL format, which is used for 3D printing in all 3D printers. Preliminary registration to superimpose the mirrored left humerus bone on the right one was carried out for at least 4 key points; their matching in shape and size was analyzed. A comparison was made of the contralateral humerus bones of one patient according to computed tomograms of 20 people. The main anatomical landmarks of the humerus bones and the distance between adjacent points were selected for comparison when the bones were superimposed on each other. Superimposed humeral bones were compared using the Hausdorff distance calculation algorithm, which is used to measure the difference between scanned models and the ground-truth model separately. To visualize the result of calculating of Hausdorff distance, that is, the difference between the bones, color mapping of the latter was performed, where the proximity to red color means the difference tends to zero, the proximity to blue - to 1 cm (the maximal obtained difference). Results. The greatest difference was recorded in humeral heads - up to 6.8 mm, and in the epicondyle: the medial epicondyle - up to 4.5 mm, the lateral epicondyle - up to 4.4 mm. Color mapping allowed to see that the difference between the heads of the humerus increases from the center of the articular surface to the attachment points of the capsule. At the level of the diaphysis, from the anatomical neck to the condyles, the size differencesamong allbones in 20 patients was no more than 1.5 mm. Conclusion. Thereby, the comparison of the shape and size of the contralateral bones of the human humerus based on the «Autoplan» program will allow applying a three-dimensional model of healthy contralateral bone in the preoperative planning for bone osteosynthesis: thus reducing the surgical risks and injury for the patient. What this paper adds For the first time, the use of a 3-dimensional model for a preoperative planning method for long tubular bone osteosynthesis using the contralateral healthy bone for affected bone has been proposed. It has been found that in the preoperative period during osteosynthesis of the diaphysis of long tubular bones, it is possible to use a healthy contralateral bone for plate of the damaged bone (on the example of the humerus fracture). The identity of the shape and size of the humerus diaphyses with an accuracy of 1.5 mm has been proved, and the possibility of using a 3-dimensional model of a healthy bone for preoperative planning for long tubular bone osteosynthesis is justified.

  • Open Access

    A preoperative planning method for long tubular bone osteosynthesis

    by A. S. Pankratov, Yu. V. Lartsev, J. G. Alayo, S. V. Ardatov, D. A. Ogurtsov, A. A. Rubtsov, Ларцев Ю. В., Алайо Х. Г.

    Objectives the development of a preoperative planning method for long tubular bone osteosynthesis using the contralateral healthy bone. Material and methods.To justify the usage of the opposite limbs intact segment model in order to reconstruct the damaged one, their matching in shape and size was analyzed. We built three-dimensional models of the right and left segments of the upper limbs of 20 people and compared them using the Hausdorff distance calculation algorithm. For treatment of a 24-year-old patient with a closed humerus fracture, an individual stereolithographic surgical template with fracture lines was created with the help of computed tomography data of the healthy humerus bone processed by AUTOPLAN EXPERT software. This template was used for pre-bending the plate for osteosynthesis. The plate positioning on the template defined the surgical approach, taking into account the anatomical structures located in the projection of the fracture line and the plate. The technique of "reverse bone reposition" on the prepared plate was applied. Results.With the help of the created 3D models we revealed the size differences of the symmetrical segments of upper limbs. The greatest difference in the limits was registered in the area of the epiphyses (heads of the humeri) up to 6.8 mm, and the smallest throughout the entire diaphysis, less than 1.5 mm. Due to preoperative planning there were no intraoperative and postoperative complications, the installation of the plate and osteosynthesis was convenient. The fracture consolidation took place in 3 months. Conclusion.The proposed method has a number of advantages. It is possible to make a stereolithographic template even for a seriously damaged bone with a copied fracture line. This allows the surgeon to plan the details of osteosynthesis, to model the plate according to the template, to determine the required length and shape of the surgical approach, thus reducing the surgical risks and injury for the patient.