Han Young Eom
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Han Young Eom has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Jong-Hwa Lee
Bioanalytical and Pharmacokinetic Research Group, Korea Institute of Toxicology, Daejeon 34114, Republic of Korea
2 shared publications - Byoung-Seok Lee
Department of Advanced Toxicology Research, Korea Institute of Toxicology, Daejeon, Republic of Korea
1 shared publication - Hye Yeon Lee
Department of Anatomy, Yonsei University College of Medicine, Seoul, Republic of Korea
1 shared publication Hyun-Deok Cho
Department of Advanced Toxicology Research, Korea Institute of Toxicology, Daejeon 34114, Republic of Korea
1 shared publicationHyun‐Deok Cho
Department of Pharmaceutical Analysis, College of Pharmacy Chung‐Ang University Seoul South Korea
1 shared publication- Jeong Ho Hwang
Department of Animal Science and Technology, Konkuk University, Seoul 05029, Korea
1 shared publication
Latest Publications
- Open Access
- 31 August 2024
- Published by Elsevier in Phytomedicine
- Vol. 134, 156014
Potential of 6′‑hydroxy justicidin B from Justicia procumbens as a therapeutic agent against coronavirus disease 2019
- 31 August 2024
- Published by Elsevier in Phytomedicine
- Vol. 134, 156014
Open AccessPotential of 6′‑hydroxy justicidin B from Justicia procumbens as a therapeutic agent against coronavirus disease 2019
- Open Access
- 26 October 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (44) , 41728-41736
LC–MS-Based Direct Quantification of MicroRNAs in Rat Blood
MicroRNA (miRNA) has recently garnered significant research attention, owing to its potential as a diagnostic biomarker and therapeutic target. Liquid chromatography-mass spectrometry (LC-MS) offers accurate quantification, multiplexing capacity, and high compatibility with various matrices. These advantages establish it as a preferred technique for detecting miRNA in biological samples. In this study, we presented an LC-MS method for directly quantifying seven miRNAs (rno-miR-150, 146a, 21, 155, 223, 181a, and 125a) associated with immune and inflammatory responses in rat whole blood. To ensure miRNA stability in the samples and efficiently purify target analytes, we compared Trizol- and proteinase K-based extraction methods, and the Trizol extraction proved to be superior in terms of analytical sensitivity and convenience. Chromatographic separation was carried out using an oligonucleotide C18 column with a mobile phase composed of N-butyldimethylamine, 1,1,1,3,3,3-hexafluoro-2-propanol, and methanol. For MS detection, we performed high-resolution full scan analysis using an orbitrap mass analyzer with negative electrospray ionization. The established method was validated by assessing its selectivity, linearity, limit of quantification, accuracy, precision, recovery, matrix effect, carry-over, and stability. The proposed assay was then applied to simultaneously monitor target miRNAs in lipopolysaccharide-treated rats. Although potentially less sensitive than conventional methods, such as qPCR and microarray, this direct-detection-based LC-MS method can accurately and precisely quantify miRNA. Given these promising results, this method could be effectively deployed in various miRNA-related applications.
- 26 October 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (44) , 41728-41736
Open AccessLC–MS-Based Direct Quantification of MicroRNAs in Rat Blood
MicroRNA (miRNA) has recently garnered significant research attention, owing to its potential as a diagnostic biomarker and therapeutic target. Liquid chromatography-mass spectrometry (LC-MS) offers accurate quantification, multiplexing capacity, and high compatibility with various matrices. These advantages establish it as a preferred technique for detecting miRNA in biological samples. In this study, we presented an LC-MS method for directly quantifying seven miRNAs (rno-miR-150, 146a, 21, 155, 223, 181a, and 125a) associated with immune and inflammatory responses in rat whole blood. To ensure miRNA stability in the samples and efficiently purify target analytes, we compared Trizol- and proteinase K-based extraction methods, and the Trizol extraction proved to be superior in terms of analytical sensitivity and convenience. Chromatographic separation was carried out using an oligonucleotide C18 column with a mobile phase composed of N-butyldimethylamine, 1,1,1,3,3,3-hexafluoro-2-propanol, and methanol. For MS detection, we performed high-resolution full scan analysis using an orbitrap mass analyzer with negative electrospray ionization. The established method was validated by assessing its selectivity, linearity, limit of quantification, accuracy, precision, recovery, matrix effect, carry-over, and stability. The proposed assay was then applied to simultaneously monitor target miRNAs in lipopolysaccharide-treated rats. Although potentially less sensitive than conventional methods, such as qPCR and microarray, this direct-detection-based LC-MS method can accurately and precisely quantify miRNA. Given these promising results, this method could be effectively deployed in various miRNA-related applications.
- 1 February 2021
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 195, 113827
Development and validation of a bioanalytical method of analyzing 3′- and 6′-sialyllactose using liquid chromatography–tandem mass spectrometry in minipig plasma and its application in a pharmacokinetic study
- 1 February 2021
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 195, 113827
Development and validation of a bioanalytical method of analyzing 3′- and 6′-sialyllactose using liquid chromatography–tandem mass spectrometry in minipig plasma and its application in a pharmacokinetic study
- 24 November 2015
- Published by Wiley in Journal of Separation Science
- Vol. 38 (24) , 4276-4285
Simultaneous determination of benzene, toluene, ethylbenzene, and xylene metabolites in human urine using electromembrane extraction combined with liquid chromatography and tandem mass spectrometry
For the first time, electromembrane extraction combined with liquid chromatography and tandem mass spectrometry was applied for the determination of urinary benzene, toluene, ethylbenzene, and xylene metabolites. S‐Phenylmercapturic acid, hippuric acid, phenylglyoxylic acid, and methylhippuric acid isomers were extracted from human urine through a supported liquid membrane consisting of 1‐octanol into an alkaline acceptor solution filling the inside of a hollow fiber by application of an electric field. Various extraction factors were investigated and optimized using response surface methodology, the statistical method. The optimum conditions were established to be 300 V applied voltage, 15 min extraction time, 1500 rpm stirring speed, and 5 mM ammonium acetate (pH 10.2) acceptor solution. The method was validated with respect to selectivity, linearity, accuracy, precision, limit of detection, limit of quantification, recovery, and reproducibility. The results showed good linearity (r2 > 0.995), precision, and accuracy. The extract recoveries were 52.8–79.0%. Finally, we applied this method to real samples and successfully measured benzene, toluene, ethylbenzene, and xylene metabolites.
- 24 November 2015
- Published by Wiley in Journal of Separation Science
- Vol. 38 (24) , 4276-4285
Simultaneous determination of benzene, toluene, ethylbenzene, and xylene metabolites in human urine using electromembrane extraction combined with liquid chromatography and tandem mass spectrometry
For the first time, electromembrane extraction combined with liquid chromatography and tandem mass spectrometry was applied for the determination of urinary benzene, toluene, ethylbenzene, and xylene metabolites. S‐Phenylmercapturic acid, hippuric acid, phenylglyoxylic acid, and methylhippuric acid isomers were extracted from human urine through a supported liquid membrane consisting of 1‐octanol into an alkaline acceptor solution filling the inside of a hollow fiber by application of an electric field. Various extraction factors were investigated and optimized using response surface methodology, the statistical method. The optimum conditions were established to be 300 V applied voltage, 15 min extraction time, 1500 rpm stirring speed, and 5 mM ammonium acetate (pH 10.2) acceptor solution. The method was validated with respect to selectivity, linearity, accuracy, precision, limit of detection, limit of quantification, recovery, and reproducibility. The results showed good linearity (r2 > 0.995), precision, and accuracy. The extract recoveries were 52.8–79.0%. Finally, we applied this method to real samples and successfully measured benzene, toluene, ethylbenzene, and xylene metabolites.