NKNetiwit Kaongoen

Netiwit Kaongoen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Netiwit Kaongoen has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The future of wearable EEG: a review of ear-EEG technology and its applications

    by Netiwit Kaongoen, Jaehoon Choi, Jin Woo Choi, Haram Kwon, Chaeeun Hwang, Guebin Hwang, Byung Hyung Kim, Sungho Jo

    Objective. This review paper provides a comprehensive overview of ear-electroencephalogram (EEG) technology, which involves recording EEG signals from electrodes placed in or around the ear, and its applications in the field of neural engineering. Approach. We conducted a thorough literature search using multiple databases to identify relevant studies related to ear-EEG technology and its various applications. We selected 123 publications and synthesized the information to highlight the main findings and trends in this field. Main results. Our review highlights the potential of ear-EEG technology as the future of wearable EEG technology. We discuss the advantages and limitations of ear-EEG compared to traditional scalp-based EEG and methods to overcome those limitations. Through our review, we found that ear-EEG is a promising method that produces comparable results to conventional scalp-based methods. We review the development of ear-EEG sensing devices, including the design, types of sensors, and materials. We also review the current state of research on ear-EEG in different application areas such as brain–computer interfaces, and clinical monitoring. Significance. This review paper is the first to focus solely on reviewing ear-EEG research articles. As such, it serves as a valuable resource for researchers, clinicians, and engineers working in the field of neural engineering. Our review sheds light on the exciting future prospects of ear-EEG, and its potential to advance neural engineering research and become the future of wearable EEG technology.


  • Decoding auditory-evoked response in affective states using wearable around-ear EEG system

    by Jaehoon Choi, Netiwit Kaongoen, HyoSeon Choi, Minuk Kim, Byung Hyung Kim, Sungho Jo

    Objective. In this paper, an around-ear EEG system is investigated as an alternative methodology to conventional scalp-EEG-based systems in classifying human affective states in the arousal-valence domain evoked in response to auditory stimuli. Approach. EEG recorded from around the ears is compared to EEG collected according to the international 10–20 system in terms of efficacy in an affective state classification task. A wearable device with eight dry EEG channels is designed for ear-EEG acquisition in this study. Twenty-one subjects participated in an experiment consisting of six sessions over three days using both ear and scalp-EEG acquisition methods. Experimental tasks consisted of listening to an auditory stimulus and self-reporting the elicited emotion in response to the said stimulus. Various features were used in tandem with asymmetry methods to evaluate binary classification performances of arousal and valence states using ear-EEG signals in comparison to scalp-EEG. Main results. We achieve an average accuracy of 67.09% ± 6.14 for arousal and 66.61% ± 6.14 for valence after training a multi-layer extreme learning machine with ear-EEG signals in a subject-dependent context in comparison to scalp-EEG approach which achieves an average accuracy of 68.59% ± 6.26 for arousal and 67.10% ± 4.99 for valence. In a subject-independent context, the ear-EEG approach achieves 63.74% ± 3.84 for arousal and 64.32% ± 6.38 for valence while the scalp-EEG approach achieves 64.67% ± 6.91 for arousal and 64.86% ± 5.95 for valence. The best results show no significant differences between ear-EEG and scalp-EEG signals for classifications of affective states. Significance. To the best of our knowledge, this paper is the first work to explore the use of around-ear EEG signals in emotion monitoring. Our results demonstrate the potential use of around-ear EEG systems for the development of emotional monitoring setups that are more suitable for use in daily affective life log systems compared to conventional scalp-EEG setups.


  • Open Access

    Neural Applications Using Immersive Virtual Reality: A Review on EEG Studies

    by Jin Woo Choi, Haram Kwon, Jaehoon Choi, Netiwit Kaongoen, Chaeeun Hwang, Minuk Kim, Byung Hyung Kim, Sungho Jo

    Recent advancements in immersive virtual reality head-mounted displays allowed users to better engage with simulated graphical environments. Having the screen egocentrically stabilized in a way such that the users may freely rotate their heads to observe virtual surroundings, head-mounted displays present virtual scenarios with rich immersion. With such an enhanced degree of freedom, immersive virtual reality displays have also been integrated with electroencephalograms, which make it possible to study and utilize brain signals non-invasively, to analyze and apply their capabilities. In this review, we introduce recent progress that utilized immersive head-mounted displays along with electroencephalograms across various fields, focusing on the purposes and experimental designs of their studies. The paper also highlights the effects of using immersive virtual reality discovered through the electroencephalogram analysis and discusses existing limitations, current trends as well as future research opportunities that may hopefully act as a useful source of information for further improvement of electroencephalogram-based immersive virtual reality applications.


  • Speech-imagery-based brain–computer interface system using ear-EEG

    by Netiwit Kaongoen, Jae Hoon Choi, Sungho Jo

    Objective. This study investigates the efficacy of electroencephalography (EEG) centered around the user’s ears (ear-EEG) for a speech-imagery-based brain–computer interface (BCI) system. Approach . A wearable ear-EEG acquisition tool was developed and its performance was directly compared to that of a conventional 32-channel scalp-EEG setup in a multi-class speech imagery classification task. Riemannian tangent space projections of EEG covariance matrices were used as input features to a multi-layer extreme learning machine classifier. Ten subjects participated in an experiment consisting of six sessions spanning three days. The experiment involves imagining four speech commands (‘Left,’ ‘Right,’ ‘Forward,’ and ‘Go back’) and staying in a rest condition. Main results. The classification accuracy of our system is significantly above the chance level (20%). The classification result averaged across all ten subjects is 38.2% and 43.1% with a maximum (max) of 43.8% and 55.0% for ear-EEG and scalp-EEG, respectively. According to an analysis of variance, seven out of ten subjects show no significant difference between the performance of ear-EEG and scalp-EEG. Significance. To our knowledge, this is the first study that investigates the performance of ear-EEG in a speech-imagery-based BCI. The results indicate that ear-EEG has great potential as an alternative to the scalp-EEG acquisition method for speech-imagery monitoring. We believe that the merits and feasibility of both speech imagery and ear-EEG acquisition in the proposed system will accelerate the development of the BCI system for daily-life use.


  • An Ear-EEG-based Brain-Computer Interface using Concentration Level for Control

    by Netiwit Kaongoen, Sungho Jo

    Ear-EEG is an alternative EEG acquisition method to the scalp-EEG conventionally used in Brain-Computer Interface (BCI). It is a more comfortable, discreet, and fashionable method comparing to the scalp-EEG. This work proposes an Ear-EEG-based BCI system that detects and utilizes the concentration level as the BCI signal. The experiments conducted in this study shows that the concentration level can be detected from the Ear-EEG acquiring around the user's ears. In the online experiment, our BCI system achieve the average true positive rate of 83% with the performance time of 3.98 seconds and false discovery rate of 16%. This study serves as another proof that Ear-EEG is a reliable EEG acquisition method especially for the BCI system that aims for the daily-life applications for normal healthy users.


  • An auditory P300-based brain-computer interface using Ear-EEG

    by Netiwit Kaongoen, Sungho Jo

    Ear-EEG is an EEG acquisition method that record EEG signal from inside the user's ear. This study fabricated an ear-EEG device and tested its ability to detect alpha activity when the subject is in a wakeful relaxation state and its performance in binary auditory P300 BCI system. The ear-EEG fabricated in this study were able to detect the alpha activity from the subjects. In auditory P300 experiment, the highest accuracy and ITR was 95.61% and 2.9685 bits/min, respectively. The surveys given to the participants point out that the ear-EEG devices in this work were easily wearable and very comfortably. These results suggest that ear-EEG is a promising alternative EEG-acquisition method that is more user-friendly and suitable for BCI system that aims for daily-life usage comparing to the conventional scalp-EEG method.


  • Two-Factor Authentication System Using P300 Response to a Sequence of Human Photographs

    by Netiwit Kaongoen, Moonwon Yu, Sungho Jo

    This paper proposes a two-factor authentication system that utilizes the knowledge factor: the knowledge of client's acquaintances as the key and inherence factor: P300 ERP responses to the visual stimuli as the medium. The system works by presenting a sequence of human photographs consisting of random people photographs mixed with a few of client's acquaintances photographs that trigger P300 responses. The system then verifies the client by considering the correctness of P300 responses to the client's acquaintances photographs. The proposed system achieves an error rate of nearly zero outperforming other brain-signal-based systems and has advantages over other conventional systems in the situations where the key is exposed to the imposer.


  • The effect of selective attention on multiple ASSRs for future BCI application

    by Netiwit Kaongoen, Sungho Jo

    Brain-computer interfaces (BCIs) that utilize auditory stimuli have been designed to support users or patients with visual impairment that are incapable of using the conventional visual-based BCI. As an alternative to auditory P300-based BCI, researchers have reported the possibility of using the auditory steady state response (ASSR) in the binary-class BCI system. In the present work, we investigated the effect of selective attention on the amplitude of ASSRs when three ASSR stimuli are simultaneously given. The result shows that the amplitude of ASSR is significantly increased by approximately 20% when the subject selectively attend to the target stimulus. There is also no difference in the effect of selective attention between when two stimuli and three stimuli are given. This current work suggests the possibility of incooperating ASSR into the auditory BCI system that deal with multiple-class problem.