Abhishek Yadav
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Abhishek Yadav has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Jonathan Michael Hagedorn
Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, Minnesota, USA
4 shared publications - Timothy Ray Deer
The Spine and Nerve Center of The Virginias, Charleston, WV 25301, USA
3 shared publications Nathan DeTemple
West Virginia School of Medicine Charleston West Virginia USA
2 shared publications- Ryan Steven D'SOuza
Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, Minnesota, USA
2 shared publications - Ajax Yang
The Spine & Pain Institute of New York New York New York USA
1 shared publication - Alon Y. Mogilner
Department of Neurosurgery, NYU Langone Health, New York, US
1 shared publication
Latest Publications
- 12 April 2024
- Published by Wiley in Pain Practice
- Vol. 24 (7) , 882-890
Relationship between number of prior lumbar spine surgeries and outcomes following spinal cord stimulator implantation: A multisite, retrospective pooled analysis
Objectives: Lumbar spine surgery is a common procedure for treating disabling spine‐related pain. In recent decades, both the number and cost of spine surgeries have increased despite technological advances and modification in surgical technique. For those patients that have continued uncontrolled back and/or lower extremity pain following lumbar spine surgery, spinal cord stimulation (SCS) has emerged as a viable treatment option. However, the impact of lumbar spine surgical history remains largely unstudied. Specifically, the current study considers the impact of number of prior lumbar spine surgeries on pain relief outcomes following SCS implantation.Materials and Methods: We queried the electronic medical record of five separate pain practices for all patients who have undergone a SCS implant between January 1, 2017, and March 1, 2020. Inclusion criteria consisted of any patients with an SCS implant who underwent a prior lumbar spine surgery. The primary outcome was the mean calculated percentage pain relief in patients based on number of prior lumbar spine surgeries.Results: There was a total of 1974 total SCS implant cases identified across five separate pain clinics. There was no difference in mean calculated pain relief in patients with one prior spine surgery versus those with two or more prior spine surgeries (28.2% vs. 25.8%, adjusted β‐coefficient –3.1, 95% CI –8.9 to 2.7, p = 0.290). Similarly, when analyzing number of spine surgeries as a continuous variable, there was no association between number of spine surgeries and calculated pain relief (adjusted β‐coefficient –1.5, 95% CI –4.0 to 1.1, p = 0.257). Additionally, after patients were stratified based on waveform, there was no association between number of prior lumbar spine surgeries (analyzed both as a categorical and continuous variable) and calculated percentage pain relief.Conclusions: This multicentered retrospective study found that there was no significant difference in pain scores in individuals who received SCS following one or more lumbar spine surgeries. Additionally, the waveform of the SCS device had no statistically significant impact on post‐operative pain scores following one or more lumbar spine surgeries.
- 12 April 2024
- Published by Wiley in Pain Practice
- Vol. 24 (7) , 882-890
Relationship between number of prior lumbar spine surgeries and outcomes following spinal cord stimulator implantation: A multisite, retrospective pooled analysis
Objectives: Lumbar spine surgery is a common procedure for treating disabling spine‐related pain. In recent decades, both the number and cost of spine surgeries have increased despite technological advances and modification in surgical technique. For those patients that have continued uncontrolled back and/or lower extremity pain following lumbar spine surgery, spinal cord stimulation (SCS) has emerged as a viable treatment option. However, the impact of lumbar spine surgical history remains largely unstudied. Specifically, the current study considers the impact of number of prior lumbar spine surgeries on pain relief outcomes following SCS implantation.Materials and Methods: We queried the electronic medical record of five separate pain practices for all patients who have undergone a SCS implant between January 1, 2017, and March 1, 2020. Inclusion criteria consisted of any patients with an SCS implant who underwent a prior lumbar spine surgery. The primary outcome was the mean calculated percentage pain relief in patients based on number of prior lumbar spine surgeries.Results: There was a total of 1974 total SCS implant cases identified across five separate pain clinics. There was no difference in mean calculated pain relief in patients with one prior spine surgery versus those with two or more prior spine surgeries (28.2% vs. 25.8%, adjusted β‐coefficient –3.1, 95% CI –8.9 to 2.7, p = 0.290). Similarly, when analyzing number of spine surgeries as a continuous variable, there was no association between number of spine surgeries and calculated pain relief (adjusted β‐coefficient –1.5, 95% CI –4.0 to 1.1, p = 0.257). Additionally, after patients were stratified based on waveform, there was no association between number of prior lumbar spine surgeries (analyzed both as a categorical and continuous variable) and calculated percentage pain relief.Conclusions: This multicentered retrospective study found that there was no significant difference in pain scores in individuals who received SCS following one or more lumbar spine surgeries. Additionally, the waveform of the SCS device had no statistically significant impact on post‐operative pain scores following one or more lumbar spine surgeries.
- Open Access
- 1 November 2023
- Published by Taylor & Francis in Advances in Medical Education and Practice
- Vol. ume 14, 1347-1355
Impact of a Preclinical Medical Student Anesthesiology Elective on the Attitudes and Perceptions of Medical Students Regarding Anesthesiology
Purpose: First- and second-year medical students typically have limited exposure to the field of anesthesiology, yet recent match data shows growing interest in the specialty. Early, structured exposure to anesthesiology in the form of a preclinical elective may allow medical students to make more informed decisions on their specialty of choice. Methods: The anesthesiology preclinical elective, BIOL 6704: “Anesthesia: Much More than Putting you to Sleep”, is a one-credit course taught at The Warren Alpert Medical School of Brown University. A survey consisting of fifteen questions assessing changes in attitudes, perceptions, and interest in anesthesiology was distributed to first- and second-year medical students before and after course participation. The results were analyzed using the Wilcoxon’s signed-rank test for paired samples. Results: The biggest impact of the preclinical elective was observed in the students’ subjective understanding of key aspects of the practice of anesthesiology. Statistically significant improvement was seen in the understanding of airway management, anesthetic pharmacology, basics of ultrasound, vascular access, anesthesiology subspecialties, and an understanding of anesthesiology residency. Overall, results were limited by our small sample size. Conclusion: Our elective allows medical students to explore anesthesiology early in their medical school career. After taking this course, students noted more familiarity with various topics in anesthesiology. Peer institutions lacking a similar course may consider using our experience to increase interest about the specialty of anesthesiology for future students.
- 1 November 2023
- Published by Taylor & Francis in Advances in Medical Education and Practice
- Vol. ume 14, 1347-1355
Open AccessImpact of a Preclinical Medical Student Anesthesiology Elective on the Attitudes and Perceptions of Medical Students Regarding Anesthesiology
Purpose: First- and second-year medical students typically have limited exposure to the field of anesthesiology, yet recent match data shows growing interest in the specialty. Early, structured exposure to anesthesiology in the form of a preclinical elective may allow medical students to make more informed decisions on their specialty of choice. Methods: The anesthesiology preclinical elective, BIOL 6704: “Anesthesia: Much More than Putting you to Sleep”, is a one-credit course taught at The Warren Alpert Medical School of Brown University. A survey consisting of fifteen questions assessing changes in attitudes, perceptions, and interest in anesthesiology was distributed to first- and second-year medical students before and after course participation. The results were analyzed using the Wilcoxon’s signed-rank test for paired samples. Results: The biggest impact of the preclinical elective was observed in the students’ subjective understanding of key aspects of the practice of anesthesiology. Statistically significant improvement was seen in the understanding of airway management, anesthetic pharmacology, basics of ultrasound, vascular access, anesthesiology subspecialties, and an understanding of anesthesiology residency. Overall, results were limited by our small sample size. Conclusion: Our elective allows medical students to explore anesthesiology early in their medical school career. After taking this course, students noted more familiarity with various topics in anesthesiology. Peer institutions lacking a similar course may consider using our experience to increase interest about the specialty of anesthesiology for future students.
- 12 April 2022
- Published by Wiley in Pain Practice
- Vol. 22 (5) , 516-521
The incidence of lumbar spine surgery following Minimally Invasive Lumbar Decompression and Superion Indirect Decompression System for treatment of lumbar spinal stenosis: a retrospective review
Introduction: Lumbar spinal stenosis affects more than 200,000 adults in the United States, resulting in approximately 38,000 operations among the Medicare population and greater than $1.5 billion in hospital bills alone. Fortunately, Minimally Invasive Lumbar Decompression (MILD) and the Superion Indirect Decompression System have shown lasting benefit and cost savings compared to more aggressive surgical options.Objective: Our primary objective was to retrospectively determine the rate of lumbar decompression surgery following the MILD and Superion procedures.Materials and Methods: This was a pooled retrospective review of LSS patients who received MILD and/or Superion procedures between January 2011 and July 2019. Adult patients with CPT codes for MILD and Superion procedures were identified. Patients were included if they had a follow‐up visit at least 2 years from the procedure date, preprocedural MRI results, and surgical notes.Results: A total of 199 patients were included in the final analysis, of which 57 patients (28.6%) underwent MILD procedure only, 124 patients (62.3%) underwent Superion only, and 18 patients (9.0%) underwent an MILD procedure initially followed by a Superion procedure. Two patients had an MILD procedure performed twice at the same level at separate encounters. A total of four patients in the entire cohort (2.0%; MILD 5.3%, Superion 0.8%) underwent subsequent lumbar spine surgery when followed for at least 2 years. It is notable that some of these patients may not have been surgical candidates and this may have skewed the results.Conclusions: Patients undergoing minimally invasive decompression treatment of lumbar spinal stenosis have low rates of subsequent open surgery which potentially results in cost savings and a reduction in severe adverse events. The reason for low surgical rate may reflect improvement in their symptoms, a preference to avoid surgery, or being deemed not a surgical candidate.
- 12 April 2022
- Published by Wiley in Pain Practice
- Vol. 22 (5) , 516-521
The incidence of lumbar spine surgery following Minimally Invasive Lumbar Decompression and Superion Indirect Decompression System for treatment of lumbar spinal stenosis: a retrospective review
Introduction: Lumbar spinal stenosis affects more than 200,000 adults in the United States, resulting in approximately 38,000 operations among the Medicare population and greater than $1.5 billion in hospital bills alone. Fortunately, Minimally Invasive Lumbar Decompression (MILD) and the Superion Indirect Decompression System have shown lasting benefit and cost savings compared to more aggressive surgical options.Objective: Our primary objective was to retrospectively determine the rate of lumbar decompression surgery following the MILD and Superion procedures.Materials and Methods: This was a pooled retrospective review of LSS patients who received MILD and/or Superion procedures between January 2011 and July 2019. Adult patients with CPT codes for MILD and Superion procedures were identified. Patients were included if they had a follow‐up visit at least 2 years from the procedure date, preprocedural MRI results, and surgical notes.Results: A total of 199 patients were included in the final analysis, of which 57 patients (28.6%) underwent MILD procedure only, 124 patients (62.3%) underwent Superion only, and 18 patients (9.0%) underwent an MILD procedure initially followed by a Superion procedure. Two patients had an MILD procedure performed twice at the same level at separate encounters. A total of four patients in the entire cohort (2.0%; MILD 5.3%, Superion 0.8%) underwent subsequent lumbar spine surgery when followed for at least 2 years. It is notable that some of these patients may not have been surgical candidates and this may have skewed the results.Conclusions: Patients undergoing minimally invasive decompression treatment of lumbar spinal stenosis have low rates of subsequent open surgery which potentially results in cost savings and a reduction in severe adverse events. The reason for low surgical rate may reflect improvement in their symptoms, a preference to avoid surgery, or being deemed not a surgical candidate.
- 18 June 2021
- Published by Wiley in Pain Practice
- Vol. 21 (8) , 859-870
Lead migration and fracture rate in dorsal root ganglion stimulation using anchoring and non‐anchoring techniques: A multicenter pooled data analysis
Introduction: Dorsal root ganglion stimulation (DRG‐S) is a neuromodulation technique introduced in the last decade with evolving implant methods. Initial prospective research found low incidences of lead migration and lead fracture with DRG‐S. However, several recent studies have highlighted high lead migration and lead fracture rates with DRG‐S. We investigated the influence of lead anchoring on migrations and fractures.Methods: We performed a retrospective review between 2016 and 2020 of individuals implanted with DRG‐S leads by 4 experienced implanters. The implanters independently changed their standard practice regarding lead anchoring over time, with opposing trends (no anchoring > anchoring, anchoring > no anchoring). We compared lead migration and lead fracture rates between anchored and unanchored DRG‐S leads in the entire study cohort. Cox regression was performed on lead migration and fracture distributions.Results: We included 756 leads (n = 565 anchored andn = 191 unanchored) from 249 patients. In unanchored leads, migration occurred in 16 leads (8.4%) from 13 patients (21.0%). In anchored leads, migration occurred in 8 leads (1.4%) from 5 patients (2.7%). Fracture in unanchored leads occurred in 6 leads (3.1%) from 6 patients (9.7%). Fractures in anchored leads occurred in 11 leads (1.9%) from 9 patients (4.8%). The migration survival distributions for the anchored and unanchored leads were statistically significantly different (p < 0.01) with decreased survival for unanchored leads (hazard ratio = 5.8, 95% confidence interval [CI] = 2.2–15.5).Discussion: We found that anchoring DRG‐S leads significantly reduces lead migration when compared to leads placed without an anchor. There was no significant difference in fracture rate between anchored and unanchored leads.
- 18 June 2021
- Published by Wiley in Pain Practice
- Vol. 21 (8) , 859-870
Lead migration and fracture rate in dorsal root ganglion stimulation using anchoring and non‐anchoring techniques: A multicenter pooled data analysis
Introduction: Dorsal root ganglion stimulation (DRG‐S) is a neuromodulation technique introduced in the last decade with evolving implant methods. Initial prospective research found low incidences of lead migration and lead fracture with DRG‐S. However, several recent studies have highlighted high lead migration and lead fracture rates with DRG‐S. We investigated the influence of lead anchoring on migrations and fractures.Methods: We performed a retrospective review between 2016 and 2020 of individuals implanted with DRG‐S leads by 4 experienced implanters. The implanters independently changed their standard practice regarding lead anchoring over time, with opposing trends (no anchoring > anchoring, anchoring > no anchoring). We compared lead migration and lead fracture rates between anchored and unanchored DRG‐S leads in the entire study cohort. Cox regression was performed on lead migration and fracture distributions.Results: We included 756 leads (n = 565 anchored andn = 191 unanchored) from 249 patients. In unanchored leads, migration occurred in 16 leads (8.4%) from 13 patients (21.0%). In anchored leads, migration occurred in 8 leads (1.4%) from 5 patients (2.7%). Fracture in unanchored leads occurred in 6 leads (3.1%) from 6 patients (9.7%). Fractures in anchored leads occurred in 11 leads (1.9%) from 9 patients (4.8%). The migration survival distributions for the anchored and unanchored leads were statistically significantly different (p < 0.01) with decreased survival for unanchored leads (hazard ratio = 5.8, 95% confidence interval [CI] = 2.2–15.5).Discussion: We found that anchoring DRG‐S leads significantly reduces lead migration when compared to leads placed without an anchor. There was no significant difference in fracture rate between anchored and unanchored leads.
- 28 January 2021
- Published by Elsevier in Neuromodulation: Technology at the Neural Interface
- Vol. 24 (4) , 695-699
Effect of Patient Characteristics on Clinical Outcomes More Than 12 Months Following Dorsal Root Ganglion Stimulation Implantation: A Retrospective Review
- 28 January 2021
- Published by Elsevier in Neuromodulation: Technology at the Neural Interface
- Vol. 24 (4) , 695-699
Effect of Patient Characteristics on Clinical Outcomes More Than 12 Months Following Dorsal Root Ganglion Stimulation Implantation: A Retrospective Review
- Open Access
- 1 December 2020
- Published by Taylor & Francis in Journal of Pain Research
- Vol. ume 13, 3349-3353
An Observational Study of Intraoperative Neuromonitoring as a Safety Mechanism in Placement of Percutaneous Dorsal Root Ganglion Stimulation and Spinal Cord Stimulation Systems
Introduction: Percutaneous neurostimulator device placement, specifically dorsal root ganglion (DRG) stimulation and spinal cord stimulation (SCS), involves the placement of thin wires within the spinal canal at specific locations, the DRG or dorsal column of the spinal cord, respectively, to provide an electrical current that modifies the pain signal as it enters the central nervous system from the periphery. Placement of neurostimulator devices is generally safe overall, but not without risk of major and minor complications. In this study, we assess the use of intraoperative neuromonitoring (IONM) as a tool to improve the safety of placing neurostimulator devices and subsequently minimizing postoperative complications. Methods: After IRB approval, an observational study was performed in 115 procedures to evaluate safety during placement of both temporary and permanent DRG and SCS systems and to document retrospectively any long-standing adverse events. Results: The rate of intraoperative neuromonitoring abnormal activity was 1.7% (n = 2), which allowed prompt recognition of nerve irritation and lead repositioning. Of the 115 consecutive implant cases performed with IONM, the postoperative minor adverse event rate was 1.7% (n = 2), which were transient and corrected with reprogramming. There were no long-standing neurological complications. Conclusion: In the largest observational study to date, we show that IONM creates a safe environment for patients undergoing SCS and DRG neurostimulator placement with the potential to decrease neurological complication rates. The use of IONM may be an alternative method to improve patient safety and outcomes as compared to monitor anesthesia care.
- 1 December 2020
- Published by Taylor & Francis in Journal of Pain Research
- Vol. ume 13, 3349-3353
Open AccessAn Observational Study of Intraoperative Neuromonitoring as a Safety Mechanism in Placement of Percutaneous Dorsal Root Ganglion Stimulation and Spinal Cord Stimulation Systems
Introduction: Percutaneous neurostimulator device placement, specifically dorsal root ganglion (DRG) stimulation and spinal cord stimulation (SCS), involves the placement of thin wires within the spinal canal at specific locations, the DRG or dorsal column of the spinal cord, respectively, to provide an electrical current that modifies the pain signal as it enters the central nervous system from the periphery. Placement of neurostimulator devices is generally safe overall, but not without risk of major and minor complications. In this study, we assess the use of intraoperative neuromonitoring (IONM) as a tool to improve the safety of placing neurostimulator devices and subsequently minimizing postoperative complications. Methods: After IRB approval, an observational study was performed in 115 procedures to evaluate safety during placement of both temporary and permanent DRG and SCS systems and to document retrospectively any long-standing adverse events. Results: The rate of intraoperative neuromonitoring abnormal activity was 1.7% (n = 2), which allowed prompt recognition of nerve irritation and lead repositioning. Of the 115 consecutive implant cases performed with IONM, the postoperative minor adverse event rate was 1.7% (n = 2), which were transient and corrected with reprogramming. There were no long-standing neurological complications. Conclusion: In the largest observational study to date, we show that IONM creates a safe environment for patients undergoing SCS and DRG neurostimulator placement with the potential to decrease neurological complication rates. The use of IONM may be an alternative method to improve patient safety and outcomes as compared to monitor anesthesia care.