MDMarine Deville

Marine Deville

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marine Deville has a total of 27 co-authors. Here are the top co-authors by number of shared publications:

  • Corinne Charlier

    Laboratory of Clinical, Forensic and Environmental Toxicology, Center for Interdisciplinary Research on Medicines (CIRM) University Hospital of Liege Liège Belgium

    5 shared publications
  • Corinne Charlier

    Laboratory of Clinical, Forensic and Environmental Toxicology, CHU of Liege, B35, 4000 Liege, Belgium; Center for Interdisciplinary Research on Medicines (CIRM), University of Liege (ULg), CHU (B35), 4000 Liege, Belgium

    3 shared publications
  • Nathalie Dubois

    Laboratory of Clinical, Forensic and Environmental Toxicology, Center for Interdisciplinary Research on Medicines (CIRM), Central University Hospital of Liege, Liege 4000, Belgium

    2 shared publications
  • Alexandru Tutunaru

    Department of Clinical Sciences, Faculty of Veterinary Medicine, University of Liège, Liège, Belgium

    1 shared publication
  • Aline Fastrès

    Department of Companion Animal Teaching and Clinical Practice, Faculty of Veterinary Medicine, FARAH, University of Liège, Quartier Vallée 2, Avenue de Cureghem 3 - B67, Liège 4000, Belgium

    1 shared publication
  • Anna Lechanteur

    University of Liege, Laboratory of Pharmaceutical Technology and Biopharmacy, Center for Interdisciplinary Research on Medicines (CIRM), Avenue Hippocrate 15, 4000 Liege, Belgium

    1 shared publication

Latest Publications

  • Barbie drug identification: Not a child's play

    by Marine Deville, Corinne Charlier

    Various samples—including two vials with a pharmaceutical appearance—were submitted to the laboratory for identification. The aim of this work was to describe the unique characteristics observed during the analysis of the powder contained in the vial. Samples were submitted to HPLC‐DAD, UHPLC‐TOF‐MS, and/or UPLC‐MS–MS analysis. The majority of the samples were easily identified as standard drugs of abuse. The main difficulty lay in identifying the powder in the vials. No match was found in the library through HPLC‐DAD analysis. Fortunately, the vials were labeled as “Melanotan II”, although the UV spectrum was not available. Mass spectrometric analysis of melanotan II was challenging, as it is a small peptide with a molecular weight of 1024 Da, which is significantly heavier than classical drugs that the laboratory usually handles. As a result, mass spectrometer's parameters can be limited to detect masses up to 1000 Da. Additionally, melanotan II is multi‐charged which is also unusual for compounds typically targeted in our daily work. Finally, the reference standard allowed us to confirm the identification with both instruments, and determine the purity of 30%. Melanotan II is not approved on the market due to safety concerns. It is used illegally mainly for tanning, explaining its nickname “Barbie drug”. To conclude, analysis of melanotan II was challenging as it is heavy and doubly charged. Moreover, its UV spectrum was initially not available in the literature. The difficulties faced by forensic scientists in detecting this drug may explain its popularity on the illicit market.


  • Open Access

    An Intravenous Pharmacokinetic Study of Cannabidiol Solutions in Piglets through the Application of a Validated Ultra-High-Pressure Liquid Chromatography Coupled to Tandem Mass Spectrometry Method for the Simultaneous Quantification of CBD and Its Carboxylated Metabolite in Plasma

    by Nathan Koch, Olivier Jennotte, Anna Lechanteur, Marine Deville, Corinne Charlier, Jean-Michel Cardot, Patrice Chiap, Brigitte Evrard

    Cannabidiol (CBD) has multiple therapeutic benefits that need to be maximized by optimizing its bioavailability. Numerous formulations are therefore being developed and their pharmacokinetics need to be studied, requiring analytical methods and data from intravenous administration. As CBD is susceptible to hepatic metabolism, the requirement of any method is to quantify metabolites such as 7-COOH-CBD. We demonstrated that CBD and 7-COOH-CBD could be simultaneously and correctly quantified in piglet plasma by using an UHPLC–MS/MS technique. The validated method allowed for an accurate bioanalysis of an intravenously injected solution consisting of CBD-HPβCD complexes. The experimental pharmacokinetic profile of CBD showed multi-exponential decay characterized by a fast apparent distribution half-life (0.25 h) and an elimination half-life of two hours. The profile of 7-COOH-CBD was not linked with the first-pass metabolism, since 80% of the maximum metabolite concentration was reached at the first sampling time point, without any decrease during the period of study. A two-compartment model was optimal to describe the experimental CBD profile. This model allowed us to calculate macro–micro constants and volumes of distribution (Vss = 3260.35 ± 2286.66 mL) and clearance (1514.5 ± 261.16 mL·h−1), showing that CBD is rapidly distributed to peripheral tissues once injected and slowly released into the bloodstream.


  • Open Access

    Intranasal and Serum Gentamicin Concentration: Comparison of Three Topical Administration Protocols in Dogs

    by Tom Biénès, Aurélie Lyssens, Hélène Machiels, Marie Eve Hercot, Aline Fastres, Tutunaru Alexandru-Cosmin, Marine Deville, Corinne Charlier, Frédéric Billen, Cécile Clercx

    Antimicrobials’ topical administration efficacy has not been assessed in dogs with upper respiratory tract disease. The aim was to compare the concentration of gentamicin in nasal lavage fluid (NALF) and in serum after three topical protocols. This was a prospective crossover study of ten healthy dogs. Gentamicin was nebulized for a duration of 1 week, twice a day, for 10 min in the first protocol (10-min protocol) and for 3 min in the second protocol (3-min protocol), while the third protocol consisted of the administration of 0.25 mL of gentamicin in each nostril (drop protocol). Median concentrations of gentamicin in NALF were 9.39 µg/mL (8.12–19.97 interquartile range), 4.96 µg/mL (4.60–6.43) and 137.00 µg/mL (110.5–162.00) in the 10-min protocol, 3-min protocol and drop protocol, respectively. The result for the drop protocol was significantly higher than those of both nebulization protocols in NALF (p = 0.039). In serum, the gentamicin concentration was 0.98 µg/mL (0.65–1.53) and 0.25 µg/mL (0.25–0.44) in the 10-min and 3-min protocols, respectively. Gentamicin was not detected in the serum of seven out of ten dogs in the drop protocol, and gentamicin was significantly higher in the 10-min protocol compared to the drop protocol (p = 0.001). This study found that the 10-min, 3-min and drop protocols achieved superior concentrations in NALF compared to the minimum inhibitory concentration for gentamicin-sensitive bacteria, while remaining below the toxic values in blood.


  • Cannabidiol in urine is not a proof of CBD consumption—lesson learned from urine sample analysis in routine caseworks

    by Marine Deville, Corinne Charlier

    Purpose Cannabidiol (CBD) has been gaining popularity in recent years. Knowing that CBD products can contain more tetrahydrocannabinol (THC) than expected, interpretation of cannabinoids concentration in urine can be tricky, especially when low amounts of THC and CBD are found. Moreover, interpretation can also be difficult due to interindividual variation in pharmacokinetics. The objective of this work was to take a critical look at the data from our daily practice as a toxicology laboratory. Methods We have collected results obtained in a first batch of 1074 urine samples submitted to cannabinoids analysis, and results of cannabinoids content of a second batch of 719 seized materials. Results CBD was detected in 163 urine specimens (15%). Its concentration was higher than the limit of quantification of 5 ng/mL in 108 samples only (10% of the sampling population). Most of CBD-positive samples were associated with a high THC-COOH concentration (> 500 ng/mL in 63.8% of CBD-positive samples) suggesting only a few CBD consumers in our population. Cannabinoids composition of seized plant materials (drug type at first glance) revealed CBD in 110 of them (15% of the sampling population), with a concentration mostly below 1%. All of the resin samples were CBD positive, and contained more THC compared to flowers. Conclusions We can conclude that urine samples from drug-type cannabis users contained a low amount of CBD, what was not described previously. These findings are useful for the interpretation of cannabinoids results in daily practice.


  • Synthetic Cathinones in Belgium: Two Case Reports with Different Outcomes Observed in the Emergency Room

    by M Deville, R Fedorowicz, F Grandjean, M Simon, C Charlier

    We report herein two cases of cathinone intoxication. The first case is about a drug addict who was admitted to the emergency room after the injection of an unknown compound. He presented with tachycardia, palpitations, mydriasis, dyspnea, dizziness, headache and nausea. After leaving the hospital against medical advice, he returned the next day with police escort, presenting aggressiveness and agitation signs. One month later, he came one more time for sleeping disorders, hallucinations and anxiety. He was finally transferred for his 21st detoxification treatment. The second case concerns a man who was wandering the streets and triedto escape when police officers called him. He confessed the snorting of n-ethylpentedrone and was admitted with severe agitation including delusion of persecution, tachycardia, mydriasis and fever. Because of his renal failure, rhabdomyolysis and metabolic acidosis, he was transferred to the ICU where he manifested worsening of the symptoms, turning into coma. He was intubated during 3 days before a complete resolution of the symptoms. A screening was performed by high resolution mass spectrometry followed by quantifications made by HPLC-DAD. In the first case, alpha-PHP was identified only during the first 2 admissions. However, as plenty of other psychotropic substances were also found, the cathinone alone could not be held directly responsible for the symptoms. In the second case, more than 2000 ng/mL of n-ethylpentedrone were found without any decrease in the next 17 hours, underlying the long half-life of this compound. Unlike the first case, symptoms could be clearly attributed to the cathinone. To conclude, cathinones can be found on the Belgian illicit drug market, with various routes of administration and clinical consequences. In these two case reports, some common points were observedinitially. However, one patient was finally able to leave the hospital without any treatment, whereas the otherwould most likely have died without intensive care.


  • Biochip array technology for new psychoactive substances detection in biological samples: Evaluation of the specificity of the Randox Evidence Investigator ®

    by Marine Deville, Ronald Bailly, Nicolas Gauthier, Pauline Pitti, Audrey Wachtelaer, Corinne Charlier

    Background: The need to detect new psychoactive substances in biological samples is of crucial interest. In this paper, the specificity of a benchtop immunoanalyzer commercialized by Randox was evaluated on real patient samples. Method: The Evidence Investigator was assessed to screen for NPS on 80 serum and urine samples coming from patients admitted to the emergency department. Targeted NPS were included in various categories such as synthetic cannabinoids, opioids and benzodiazepines. Results were compared with a chromatographic technique coupled with mass spectrometry. Results: No NPS was detected by the reference technique. Concerning immunoanalysis, some piperazines were positive, caused by the presence of medicine containing this chemical structure. Clonazepam and fentanyl derivatives were confirmed in some cases, but sometimes the positivity was explained by other opiates or benzodiazepines, which also explained two samples falsely positive for etizolam. Conclusions: The Randox Evidence Investigator was rapid and easy to use. It can be used as a first intention but always followed by a more specific technique in order to detect false positive result.


  • Potential 2-Aminoindane Fatality Invalidated by Careful Mass Spectrometric Analysis

    by Marine Deville, Nathalie Dubois, Corinne Charlier

    We describe herewith the case of a patient presenting to the emergency department for worsening ear–nose–throat symptoms. As chemsex was evocated by the family, patient’s serum was submitted to a new psychoactive substances screening. After a simple liquid–liquid extraction, serum was injected on a high-resolution mass spectrometer using quite usual conditions (C18 column, gradient mode with acidic buffer, methanol and acetonitrile). An almost perfect match with 2-aminoindane (2-AI) was observed considering that the precursor ion was present in the sample but absent in the commercial library. Literature concerning 2-AI is sparse, and further investigations were undertaken. After injection of the reference standard, a small retention time shift has been observed (0.3 min) between the standard and the sample. The case was only closed while spiking the sample with the standard, giving rise to two distinct peaks. As a result, 2-AI was then considered as absent from the sample and death was attributed only to infection. Moreover, a rapid liquid chromatography–tandem mass spectrometry method dedicated to 2-AI was developed. It generated the same false-positive result highlighted by significant differences observed in ion ratios (2.37 for the sample versus 6.62 for the neat standard).


  • L’alcool en questions

    by Marine Deville, Raphael Denooz, Corinne Charlier