Sebastian Burgmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sebastian Burgmann has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Uwe Janoske
5 shared publicationsJürgen Czarske
3 shared publicationsLars Büttner
3 shared publications- Martin Rohde3 shared publications
Michael Dues
3 shared publications- Uwe Janoske
University Wuppertal
3 shared publications
Latest Publications
- Open Access
- 15 August 2026
- Published by Wiley in Advanced Materials Technologies
- Vol. 11 (20) , e71236
Upscaling Pulsed Laser Fragmentation in Liquids by Advanced Free‐Flow Setups
Among the various nanoparticle synthesis techniques to address the growing demand for nanoparticles, pulsed laser fragmentation in liquids (PLFL) stands out as a simple, versatile, and sustainable method for obtaining nanoparticles (NPs) with unprecedented purity. Despite the potential to tailor the size, composition, structure, and defects of NPs via laser irradiation of a free‐flowing colloid jet, upscaling PLFL is oftentimes realized by employing costly high‐power laser sources. Herein, two improved flat‐film setups are introduced and compared with the conventional PLFL setup for the synthesis of ZnO NPs, which represent a promising model material for manifold applications. Indeed, a twofold reduction of average NP size down to less than 7 nm at 60% productivity increase and constant energy input can be achieved. Moreover, the microparticle conversion efficiency increases up to 65%, while crucial upscaling criteria, such as colloid heating, are optimized to prevent NP ripening and colloid evaporation. Numerical simulations reveal that a flat liquid surface reduces nonlinear interactions and provides more consistent irradiation conditions. The results emphasize the potential of synergistic optimization of the laser and liquid parameters for upscaled PLFL as a competitive technique for obtaining ligand‐free, green, and ultra‐small NPs.
- 15 August 2026
- Published by Wiley in Advanced Materials Technologies
- Vol. 11 (20) , e71236
Open AccessUpscaling Pulsed Laser Fragmentation in Liquids by Advanced Free‐Flow Setups
Among the various nanoparticle synthesis techniques to address the growing demand for nanoparticles, pulsed laser fragmentation in liquids (PLFL) stands out as a simple, versatile, and sustainable method for obtaining nanoparticles (NPs) with unprecedented purity. Despite the potential to tailor the size, composition, structure, and defects of NPs via laser irradiation of a free‐flowing colloid jet, upscaling PLFL is oftentimes realized by employing costly high‐power laser sources. Herein, two improved flat‐film setups are introduced and compared with the conventional PLFL setup for the synthesis of ZnO NPs, which represent a promising model material for manifold applications. Indeed, a twofold reduction of average NP size down to less than 7 nm at 60% productivity increase and constant energy input can be achieved. Moreover, the microparticle conversion efficiency increases up to 65%, while crucial upscaling criteria, such as colloid heating, are optimized to prevent NP ripening and colloid evaporation. Numerical simulations reveal that a flat liquid surface reduces nonlinear interactions and provides more consistent irradiation conditions. The results emphasize the potential of synergistic optimization of the laser and liquid parameters for upscaled PLFL as a competitive technique for obtaining ligand‐free, green, and ultra‐small NPs.
- 1 August 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (8)
Vibration-induced droplet drainage on filter fleeces for compressed air filtration
The improvement of drainage behavior of small oil droplets on a filter fleece due to vibration excitation is investigated. In compressed air filtration, deposited oil droplets increase the pressure loss, which raises operating costs. Earlier drainage reduces this pressure loss. In the experimental setup, droplets are generated using an injection pump, while a constant volumetric flow passes through the filter media. The substrate, including the fleece, is positioned as in a real filter configuration, and vibration is applied in a targeted manner with respect to direction and frequency. Using high-speed imaging and a transmitted light method, droplet contours are captured. Changes in droplet parameters over time with and without excitation are analyzed. The study demonstrates how filter media and vibration characteristics influence droplet drainage. For volume flows below 1 μl/s, vibration reduces drainage time and may thus lower pressure loss. A simplified theoretical model is introduced to describe the critical droplet volume under vibration. It incorporates gravitational, inertial, and viscosity-dependent damping forces as well as adhesion via contact angle hysteresis. The normalized model relates dynamic and static contact angles and predicts a decreasing drainage threshold for lower viscosities. Fitted to experimental data, the model achieves excellent agreement and reflects the diminishing effect of vibration with increasing viscosity. The model suggests that beyond a critical viscosity, droplet motion is no longer enhanced by vibration under the tested conditions.
- 1 August 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (8)
Vibration-induced droplet drainage on filter fleeces for compressed air filtration
The improvement of drainage behavior of small oil droplets on a filter fleece due to vibration excitation is investigated. In compressed air filtration, deposited oil droplets increase the pressure loss, which raises operating costs. Earlier drainage reduces this pressure loss. In the experimental setup, droplets are generated using an injection pump, while a constant volumetric flow passes through the filter media. The substrate, including the fleece, is positioned as in a real filter configuration, and vibration is applied in a targeted manner with respect to direction and frequency. Using high-speed imaging and a transmitted light method, droplet contours are captured. Changes in droplet parameters over time with and without excitation are analyzed. The study demonstrates how filter media and vibration characteristics influence droplet drainage. For volume flows below 1 μl/s, vibration reduces drainage time and may thus lower pressure loss. A simplified theoretical model is introduced to describe the critical droplet volume under vibration. It incorporates gravitational, inertial, and viscosity-dependent damping forces as well as adhesion via contact angle hysteresis. The normalized model relates dynamic and static contact angles and predicts a decreasing drainage threshold for lower viscosities. Fitted to experimental data, the model achieves excellent agreement and reflects the diminishing effect of vibration with increasing viscosity. The model suggests that beyond a critical viscosity, droplet motion is no longer enhanced by vibration under the tested conditions.
- Open Access
- 2 June 2025
- Published by Elsevier in International Journal of Multiphase Flow
- Vol. 191
Interface reconstruction of adhering droplets for distortion correction using color-coded glare points and deep learning
- 2 June 2025
- Published by Elsevier in International Journal of Multiphase Flow
- Vol. 191
Open AccessInterface reconstruction of adhering droplets for distortion correction using color-coded glare points and deep learning
- Open Access
- 17 May 2025
- Published by Springer Nature in The European Physical Journal Special Topics
- Vol. 235 (2) , 379-387
Numerical analysis and experimental validation of the interaction of droplet oscillation and gas flow separation for two adhering droplets in a channel flow
Droplets and their movement on solid walls can be observed in many technical applications. The droplets can be moved by external forces, e.g. aerodynamic or vibrational forces. If the velocity of the gas flow is higher than a critical one, the gliding motion of the droplet starts. Before the gliding motion, i.e. the droplet is still pinned, an oscillation of the contour can be observed. In this work, the interaction of the droplet oscillation and the surrounding gas flow is studied experimentally and numerically for two droplets with different diameters and in a channel flow which are positioned at various distances in flow direction. It can be shown, that the frequency of the gas flow separation corresponds to the Eigenfrequencies (EFs) of the droplets. For larger distances between droplets, only the second EF of the droplet in the backflow can be detected in the frequency spectra of the gas flow. If the distance is smaller than two droplet diameters, the first and second EF can be measured.
- 17 May 2025
- Published by Springer Nature in The European Physical Journal Special Topics
- Vol. 235 (2) , 379-387
Open AccessNumerical analysis and experimental validation of the interaction of droplet oscillation and gas flow separation for two adhering droplets in a channel flow
Droplets and their movement on solid walls can be observed in many technical applications. The droplets can be moved by external forces, e.g. aerodynamic or vibrational forces. If the velocity of the gas flow is higher than a critical one, the gliding motion of the droplet starts. Before the gliding motion, i.e. the droplet is still pinned, an oscillation of the contour can be observed. In this work, the interaction of the droplet oscillation and the surrounding gas flow is studied experimentally and numerically for two droplets with different diameters and in a channel flow which are positioned at various distances in flow direction. It can be shown, that the frequency of the gas flow separation corresponds to the Eigenfrequencies (EFs) of the droplets. For larger distances between droplets, only the second EF of the droplet in the backflow can be detected in the frequency spectra of the gas flow. If the distance is smaller than two droplet diameters, the first and second EF can be measured.
- Open Access
- 25 October 2024
- Published by Elsevier in International Journal of Multiphase Flow
- Vol. 182
3D-3C measurements of flow reversal in small sessile drops in shear flow
- 25 October 2024
- Published by Elsevier in International Journal of Multiphase Flow
- Vol. 182
Open Access3D-3C measurements of flow reversal in small sessile drops in shear flow
- 10 November 2023
- Published by Elsevier in International Journal of Multiphase Flow
- Vol. 171
The impact of a two-dimensional vibration excitation on the critical incident flow velocity of a sessile droplet
- 10 November 2023
- Published by Elsevier in International Journal of Multiphase Flow
- Vol. 171
The impact of a two-dimensional vibration excitation on the critical incident flow velocity of a sessile droplet
- 26 May 2022
- Published by Elsevier in International Journal of Multiphase Flow
- Vol. 153
Inner and outer flow of an adhering droplet in shear flow
- 26 May 2022
- Published by Elsevier in International Journal of Multiphase Flow
- Vol. 153
Inner and outer flow of an adhering droplet in shear flow
- 24 March 2022
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 154
3D Imaging with Double-Helix Point Spread Function and Dynamic Aberration Correction Using a Deformable Mirror
- 24 March 2022
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 154
3D Imaging with Double-Helix Point Spread Function and Dynamic Aberration Correction Using a Deformable Mirror
- 29 January 2022
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 89 (3) , 178-188
Flow-measurements in the wake of an oscillating sessile droplet using laser-Doppler velocity profile sensor
Although relevant in many technical applications, the removal of sessile droplets on surfaces by an (air-) flow is still hard to predict. The flow around the droplet has not been investigated in detail so far but knowledge on the flow structure is essential for the assessment of appropriate drag force correlation. Small droplets (in the range of 5–40 µl) on PMMA substrate in an air flow are investigated. Due to the small size of the droplet the laser-Doppler velocity profile sensor with frequency shift is applied to measure the flow in the wake of the oscillating, still adhering droplet. Thanks to the high spatial and temporal resolution of Laser-Doppler velocity profile sensor and its capability to measure bidirectional flows, the flow behind the droplet can be precisely analyzed. Additional hot-film measurements are used to investigate the temporal behavior of the flow. Complementary, numerical simulation is performed applying a modified VOF (Volume-of-Fluid) method. The combination of the experimental and numerical data gives new insight in the wake flow structure of sessile droplets: With increasing Reynolds number, a backflow can be detected in the wake of the droplet. A separated shear layer stemming from the upper side of the droplet leads to a vortex shedding with formation of a recirculation region in the temporal mean. In contrast to rigid hemispheres, the movement of the air-liquid interface of the droplet leads to an internal flow which is driven by the outer flow structure and vice versa. This is a hint that drag coefficients of sessile droplets cannot be simply derived by analyzing flows of rigid hemispherical structures. Additionally, droplet contour and wake flow exhibit the same characteristic oscillation frequency. The corresponding Strouhal number is almost constant at 0.03 compared to the Strouhal number of a rigid hemisphere of 0.28. Therefore, it can be assumed that an aeroelastic self-excitation effect may be present that eventually leads to droplet movement.
- 29 January 2022
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 89 (3) , 178-188
Flow-measurements in the wake of an oscillating sessile droplet using laser-Doppler velocity profile sensor
Although relevant in many technical applications, the removal of sessile droplets on surfaces by an (air-) flow is still hard to predict. The flow around the droplet has not been investigated in detail so far but knowledge on the flow structure is essential for the assessment of appropriate drag force correlation. Small droplets (in the range of 5–40 µl) on PMMA substrate in an air flow are investigated. Due to the small size of the droplet the laser-Doppler velocity profile sensor with frequency shift is applied to measure the flow in the wake of the oscillating, still adhering droplet. Thanks to the high spatial and temporal resolution of Laser-Doppler velocity profile sensor and its capability to measure bidirectional flows, the flow behind the droplet can be precisely analyzed. Additional hot-film measurements are used to investigate the temporal behavior of the flow. Complementary, numerical simulation is performed applying a modified VOF (Volume-of-Fluid) method. The combination of the experimental and numerical data gives new insight in the wake flow structure of sessile droplets: With increasing Reynolds number, a backflow can be detected in the wake of the droplet. A separated shear layer stemming from the upper side of the droplet leads to a vortex shedding with formation of a recirculation region in the temporal mean. In contrast to rigid hemispheres, the movement of the air-liquid interface of the droplet leads to an internal flow which is driven by the outer flow structure and vice versa. This is a hint that drag coefficients of sessile droplets cannot be simply derived by analyzing flows of rigid hemispherical structures. Additionally, droplet contour and wake flow exhibit the same characteristic oscillation frequency. The corresponding Strouhal number is almost constant at 0.03 compared to the Strouhal number of a rigid hemisphere of 0.28. Therefore, it can be assumed that an aeroelastic self-excitation effect may be present that eventually leads to droplet movement.
- 1 June 2021
- Published by Elsevier in Journal of Biomechanics
- Vol. 123, 110529
Experimental study on the influence of model variations on the airway occlusion of an obstructive sleep apnea patient
- 1 June 2021
- Published by Elsevier in Journal of Biomechanics
- Vol. 123, 110529
Experimental study on the influence of model variations on the airway occlusion of an obstructive sleep apnea patient