Sneh Talwar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sneh Talwar has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Todd Do Jaeblon
University of Maryland Capital Region Medical Center, Department of Orthopaedic Traumatology, Largo, MD
2 shared publications - Brent A. Bauer
Division of General Internal Medicine, Mayo Clinic, Rochester, MN, USA
1 shared publication Brent J Bauer
University of Maryland Capital Region Medical Center, Department of Orthopaedic Traumatology, Largo, MD
1 shared publication- Brian Fochtman
The Department of Biochemistry & Molecular Medicine, The George Washington University Medical Center, Washington, DC 20037
1 shared publication Carlos Pa-C Molestina
University of Maryland Capital Region Medical Center, Department of Orthopaedic Traumatology, Largo, MD
1 shared publication- Charles Hadley King
University of California, Irvine, Institute for Clinical and Translational Science
1 shared publication
Latest Publications
- 5 May 2026
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 40 (10) , 517-523
Modified CT Sagittal Angle Measure: Accuracy in Determining Hip Stability for Posterior Wall Acetabulum Fractures and Observer Reliability and Agreement Among Inexperienced Observers.
OBJECTIVES: To describe modifications to the original CT sagittal angle measure (SAM) for predicting hip stability after posterior wall acetabular fractures (PWF), and to assess modified sagittal angle measure (mSAM) accuracy and resident agreement and accuracy with the mSAM relative to examination under anesthesia (EUA). METHODS: Design: Retrospective review of prospectively collected data Setting: Academic Level 2 Trauma Center Intervention: Results of a modification of the sagittal CT based PWF measurement (mSAM) and gold standard exam under anesthesia (EUA) were collected and evaluated. Patient Selection Criteria: Patients with PWFs (AO/OTA 62A.1) requiring an EUA from June, 2017, through July, 2025 were included. Outcome Measures and Comparisons: The accuracy of mSAMs by the lead author and residents in predicting hip stability was quantified by sensitivity, specificity, positive predictive value, and negative predictive value using EUA, performed by fellowship trained orthopaedic surgeons, as the reference standard. A receiver operating characteristic (ROC) curve analysis was used to determine whether mSAM reproduced the published SAM threshold angles most closely associated with hip stability, using EUA as the reference standard. Modified SAM reliability and agreement was assessed with intraclass correlation coefficients (ICC) after measurements in two rounds, separated by one month. Resident agreement for mSAM in predicting hip stability after PWF was compared with their agreement for the axial CT-based percentage of posterior wall fracture (PPWF) measurement. RESULTS: The mSAM sensitivity and specificity for predicting hip stability from 84 subjects (male: 65 [77%]; median age: 35.0 years [range: 17–75] years) was 97.7% and 100.0%, respectively (95% CI 87.7-99.9%, 91.4-100%). ROC analysis identified the optimal mSAM thresholds of ≥71° for instability, and ≤70° for stability. Resident measurements of mSAM resulted in 100.0% sensitivity and 94.4% specificity for predicting stability in round 1 (95% confidence interval [CI] 91.6-100.0%, 72.7-99.9%) and 100.0% sensitivity and specificity in round 2 (95% CI 91.6 -100%, 81.5-100.0%). Interrater reliability for mSAM was good in round 1 (ICC = 0.83, 95% CI 0.70-0.93) and round 2 (ICC = 0.86, 95% CI 0.74-0.95). Intrarater reliability was good for two residents and excellent for four (range 0.79-0.99). Interrater reliability for PPWF was good (ICC = 0.78, 95% CI 0.62-0.91). CONCLUSIONS: Optimal mSAM measures predictive of hip instability were ≥71° and ≤70° for stability following PWF. The mSAM demonstrated good to excellent intrarater reliability among residents, and the intraclass correlation coefficient was higher than the PPWF measure. LEVEL OF EVIDENCE: Level III, Diagnostic.
- 5 May 2026
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 40 (10) , 517-523
Modified CT Sagittal Angle Measure: Accuracy in Determining Hip Stability for Posterior Wall Acetabulum Fractures and Observer Reliability and Agreement Among Inexperienced Observers.
OBJECTIVES: To describe modifications to the original CT sagittal angle measure (SAM) for predicting hip stability after posterior wall acetabular fractures (PWF), and to assess modified sagittal angle measure (mSAM) accuracy and resident agreement and accuracy with the mSAM relative to examination under anesthesia (EUA). METHODS: Design: Retrospective review of prospectively collected data Setting: Academic Level 2 Trauma Center Intervention: Results of a modification of the sagittal CT based PWF measurement (mSAM) and gold standard exam under anesthesia (EUA) were collected and evaluated. Patient Selection Criteria: Patients with PWFs (AO/OTA 62A.1) requiring an EUA from June, 2017, through July, 2025 were included. Outcome Measures and Comparisons: The accuracy of mSAMs by the lead author and residents in predicting hip stability was quantified by sensitivity, specificity, positive predictive value, and negative predictive value using EUA, performed by fellowship trained orthopaedic surgeons, as the reference standard. A receiver operating characteristic (ROC) curve analysis was used to determine whether mSAM reproduced the published SAM threshold angles most closely associated with hip stability, using EUA as the reference standard. Modified SAM reliability and agreement was assessed with intraclass correlation coefficients (ICC) after measurements in two rounds, separated by one month. Resident agreement for mSAM in predicting hip stability after PWF was compared with their agreement for the axial CT-based percentage of posterior wall fracture (PPWF) measurement. RESULTS: The mSAM sensitivity and specificity for predicting hip stability from 84 subjects (male: 65 [77%]; median age: 35.0 years [range: 17–75] years) was 97.7% and 100.0%, respectively (95% CI 87.7-99.9%, 91.4-100%). ROC analysis identified the optimal mSAM thresholds of ≥71° for instability, and ≤70° for stability. Resident measurements of mSAM resulted in 100.0% sensitivity and 94.4% specificity for predicting stability in round 1 (95% confidence interval [CI] 91.6-100.0%, 72.7-99.9%) and 100.0% sensitivity and specificity in round 2 (95% CI 91.6 -100%, 81.5-100.0%). Interrater reliability for mSAM was good in round 1 (ICC = 0.83, 95% CI 0.70-0.93) and round 2 (ICC = 0.86, 95% CI 0.74-0.95). Intrarater reliability was good for two residents and excellent for four (range 0.79-0.99). Interrater reliability for PPWF was good (ICC = 0.78, 95% CI 0.62-0.91). CONCLUSIONS: Optimal mSAM measures predictive of hip instability were ≥71° and ≤70° for stability following PWF. The mSAM demonstrated good to excellent intrarater reliability among residents, and the intraclass correlation coefficient was higher than the PPWF measure. LEVEL OF EVIDENCE: Level III, Diagnostic.
- 28 April 2026
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 40 (9) , 503-511
Interpretation Accuracy between Orthopaedic Surgeons and Qualified Remote Spanish Interpreters in a Trauma Setting
OBJECTIVES: To assess the interpretation accuracy of remote qualified Spanish medical interpreters (QMI) in an orthopaedic trauma setting and determine whether interpretation method (telephonic or video), delivery speed, and subject complexity were associated with interpretation accuracy. METHODS: Three clinical vignettes—simple, moderate, and complex—describing fictitious orthopaedic trauma injuries, treatments, complications, and outcomes were written by the investigators. An investigator read each vignette type to a simulated patient through twenty randomly selected QMIs (ten via telephone and ten via video), all of whom were trained, proficiency-tested, and blinded to the study design, yielding 60 total interpretations. Data collected included interpretation method, English delivery speed (words per minute) and vignette complexity. One orthopaedic traumatologist and one bilingual physician assistant evaluated transcriptions of recorded QMI Spanish interpretations using a nonvalidated, criterion-referenced, expert-derived categorical assessment reflecting the degree to which an interpreter preserved the fidelity of the original vignette for patient ascertainment of diagnosis, treatment, risks, and prognosis, termed overall interpretation designation (OID). OID was classified, “acceptable,” “borderline,” or “unacceptable.” A second orthopaedist, blinded to the first two investigators’ preliminary translation designations, independently evaluated disputed translations and adjudicated them to consensus OID. RESULTS: Of the 60 interpretations, 46.7% were designated acceptable, 18.3% as borderline, and 35.0% unacceptable. Interpretation accuracy was not associated with vignette complexity (moderate odds ratio [OR] :reference; simple OR: 0.81, 95% CI 0.21–2.95, p = 0.75; complex OR: 1.49, 95% CI 0.36–6.74, p = 0.59) or delivery speed (Avg: 148 words per minute, range: 129.1–169.0, OR 0.98, 95% CI 0.92–1.04, p = 0.53). Odds of an acceptable interpretation were higher with video compared with telephonic interpretation (OR 6.21, 95% CI 2.17–19.48, p < 0.01). CONCLUSIONS: Less than half of Spanish interpretations delivered to simulated orthopaedic trauma patients by qualified medical interpreters were designated as acceptable by provider investigators, and 35% were unacceptable. The odds of an acceptable interpretation were over six times greater with remote video interpretation compared with telephonic interpretation. LEVEL OF EVIDENCE: Level III, Prognostic case control.
- 28 April 2026
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 40 (9) , 503-511
Interpretation Accuracy between Orthopaedic Surgeons and Qualified Remote Spanish Interpreters in a Trauma Setting
OBJECTIVES: To assess the interpretation accuracy of remote qualified Spanish medical interpreters (QMI) in an orthopaedic trauma setting and determine whether interpretation method (telephonic or video), delivery speed, and subject complexity were associated with interpretation accuracy. METHODS: Three clinical vignettes—simple, moderate, and complex—describing fictitious orthopaedic trauma injuries, treatments, complications, and outcomes were written by the investigators. An investigator read each vignette type to a simulated patient through twenty randomly selected QMIs (ten via telephone and ten via video), all of whom were trained, proficiency-tested, and blinded to the study design, yielding 60 total interpretations. Data collected included interpretation method, English delivery speed (words per minute) and vignette complexity. One orthopaedic traumatologist and one bilingual physician assistant evaluated transcriptions of recorded QMI Spanish interpretations using a nonvalidated, criterion-referenced, expert-derived categorical assessment reflecting the degree to which an interpreter preserved the fidelity of the original vignette for patient ascertainment of diagnosis, treatment, risks, and prognosis, termed overall interpretation designation (OID). OID was classified, “acceptable,” “borderline,” or “unacceptable.” A second orthopaedist, blinded to the first two investigators’ preliminary translation designations, independently evaluated disputed translations and adjudicated them to consensus OID. RESULTS: Of the 60 interpretations, 46.7% were designated acceptable, 18.3% as borderline, and 35.0% unacceptable. Interpretation accuracy was not associated with vignette complexity (moderate odds ratio [OR] :reference; simple OR: 0.81, 95% CI 0.21–2.95, p = 0.75; complex OR: 1.49, 95% CI 0.36–6.74, p = 0.59) or delivery speed (Avg: 148 words per minute, range: 129.1–169.0, OR 0.98, 95% CI 0.92–1.04, p = 0.53). Odds of an acceptable interpretation were higher with video compared with telephonic interpretation (OR 6.21, 95% CI 2.17–19.48, p < 0.01). CONCLUSIONS: Less than half of Spanish interpretations delivered to simulated orthopaedic trauma patients by qualified medical interpreters were designated as acceptable by provider investigators, and 35% were unacceptable. The odds of an acceptable interpretation were over six times greater with remote video interpretation compared with telephonic interpretation. LEVEL OF EVIDENCE: Level III, Prognostic case control.
- Open Access
Communicating Regulatory High Throughput Sequencing Data Using BioCompute Objects
For regulatory submissions of next generation sequencing (NGS) data it is vital for the analysis workflow to be robust, reproducible, and understandable. This project demonstrates that the use of the IEEE 2791-2020 Standard, (BioCompute objects [BCO]) enables complete and concise communication of NGS data analysis results. One arm of a clinical trial was replicated using synthetically generated data made to resemble real biological data. Two separate, independent analyses were then carried out using BCOs as the tool for communication of analysis: one to simulate a pharmaceutical regulatory submission to the FDA, and another to simulate the FDA review. The two results were compared and tabulated for concordance analysis: of the 118 simulated patient samples generated, the final results of 117 (99.15%) were in agreement. This high concordance rate demonstrates the ability of a BCO, when a verification kit is included, to effectively capture and clearly communicate NGS analyses within regulatory submissions. BCO promotes transparency and induces reproducibility, thereby reinforcing trust in the regulatory submission process.
Open AccessCommunicating Regulatory High Throughput Sequencing Data Using BioCompute Objects
For regulatory submissions of next generation sequencing (NGS) data it is vital for the analysis workflow to be robust, reproducible, and understandable. This project demonstrates that the use of the IEEE 2791-2020 Standard, (BioCompute objects [BCO]) enables complete and concise communication of NGS data analysis results. One arm of a clinical trial was replicated using synthetically generated data made to resemble real biological data. Two separate, independent analyses were then carried out using BCOs as the tool for communication of analysis: one to simulate a pharmaceutical regulatory submission to the FDA, and another to simulate the FDA review. The two results were compared and tabulated for concordance analysis: of the 118 simulated patient samples generated, the final results of 117 (99.15%) were in agreement. This high concordance rate demonstrates the ability of a BCO, when a verification kit is included, to effectively capture and clearly communicate NGS analyses within regulatory submissions. BCO promotes transparency and induces reproducibility, thereby reinforcing trust in the regulatory submission process.