Matthias Bungartz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Matthias Bungartz has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Frank Layher
Orthopedic Department of the Waldkliniken Eisenberg, Professorship of the University Hospital Jena, 07607 Eisenberg, Germany
4 shared publications - Georg Matziolis
Orthopaedics, Campus Waldkliniken Eisenberg University Hospital Jena, Friedrich Schiller University Jena Germany
4 shared publications - Olaf Brinkmann
Department of Orthopaedics, Friedrich-Schiller-University of Jena, Campus Eisenberg, Klosterlausnitzer Straße 81, D-07607, Eisenberg, Germany
4 shared publications - Alexander Maslaris
Academic Orthopaedic Department, Papageorgiou General Hospital, School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece
3 shared publications - Emmanouil Liodakis
Klinik für Unfall-, Hand- und Wiederherstellungschirurgie, UKS Universitätsklinikum des Saarlandes, Kirrberger Straße 100, 66424 Homburg, Germany
2 shared publications Alexander Maslaris
Department of Orthopaedics, Waldkliniken Eisenberg, Chair of the Jena University Hospital, Klosterlausnitzer Straße 81, 07607 Eisenberg, Germany
1 shared publication
Latest Publications
- 1 January 2022
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 27 (1) , 146-152
Reliability analysis of CT torsion assessment after closed cephalomedullary nailing of trochanteric femoral fractures. A comparison study of six established methods
- 1 January 2022
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 27 (1) , 146-152
Reliability analysis of CT torsion assessment after closed cephalomedullary nailing of trochanteric femoral fractures. A comparison study of six established methods
- Open Access
Minimally Invasive Internal Fixation of Femoral Shaft Fractures—A Biomechanical Study with a Disruptive Technique
(1) Background: In polytrauma patients, femur fractures are usually stabilised by external fixation for damage control, later being treated with definitive plate or nail osteosynthesis. Screw/rod systems established in spinal surgery might be inserted for internal fixation, providing sufficient fracture stability that subsequent intervention is unnecessary. This was to be investigated biomechanically. (2) Methods: The unilaterally applied spinal internal fixator (IF) was subjected to load and deformation analysis on artificial femurs with 32-A3 fracture according to AO classification. Distance of screws to fracture and rod to cortical bone were analysed as parameters influenced surgically as stiffness and deformation of the treated fracture. In addition, the stability of another construct with a second screw/rod system was determined. The axial load in stance phase during walking was simulated. The results were compared against an established fixed-angle plate osteosynthesis (IP). (3) Results: There were no implant failures in the form of fractures, avulsions or deformations. All unilateral IF combinations were inferior to IP in terms of stability and stiffness. The bilateral construct with two screw/rod systems achieved biomechanical properties comparable to IP. 4) Conclusion: Biomechanically, a biplanar screw/rod system is suitable for definitive fracture stabilisation of the femur, despite a damage control approach.
Open AccessMinimally Invasive Internal Fixation of Femoral Shaft Fractures—A Biomechanical Study with a Disruptive Technique
(1) Background: In polytrauma patients, femur fractures are usually stabilised by external fixation for damage control, later being treated with definitive plate or nail osteosynthesis. Screw/rod systems established in spinal surgery might be inserted for internal fixation, providing sufficient fracture stability that subsequent intervention is unnecessary. This was to be investigated biomechanically. (2) Methods: The unilaterally applied spinal internal fixator (IF) was subjected to load and deformation analysis on artificial femurs with 32-A3 fracture according to AO classification. Distance of screws to fracture and rod to cortical bone were analysed as parameters influenced surgically as stiffness and deformation of the treated fracture. In addition, the stability of another construct with a second screw/rod system was determined. The axial load in stance phase during walking was simulated. The results were compared against an established fixed-angle plate osteosynthesis (IP). (3) Results: There were no implant failures in the form of fractures, avulsions or deformations. All unilateral IF combinations were inferior to IP in terms of stability and stiffness. The bilateral construct with two screw/rod systems achieved biomechanical properties comparable to IP. 4) Conclusion: Biomechanically, a biplanar screw/rod system is suitable for definitive fracture stabilisation of the femur, despite a damage control approach.
- 1 April 2021
- Published by Elsevier in Clinical Biomechanics
- Vol. 84, 105327
Biodegradable cement augmentation of gamma nail osteosynthesis reduces migration in pertrochanteric fractures, a biomechanical in vitro study
- 1 April 2021
- Published by Elsevier in Clinical Biomechanics
- Vol. 84, 105327
Biodegradable cement augmentation of gamma nail osteosynthesis reduces migration in pertrochanteric fractures, a biomechanical in vitro study
- 6 November 2019
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 140 (6) , 727-734
A novel method for intraoperative osseomechanical strength measurements: a biomechanical ex vivo evaluation on proximal femora
The increasing number of geriatric traumatology cases has intensified the need to reliably and objectively evaluate local bone quality, the latter poses a decisive factor for the choice of an optimal approach to treat osteoporotic fractures. Osteodensitometry imaging techniques are not routinely available in acute operative settings, nor do they provide objective information on local bone properties specifically needed for the prognosis of implant stability.
- 6 November 2019
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 140 (6) , 727-734
A novel method for intraoperative osseomechanical strength measurements: a biomechanical ex vivo evaluation on proximal femora
The increasing number of geriatric traumatology cases has intensified the need to reliably and objectively evaluate local bone quality, the latter poses a decisive factor for the choice of an optimal approach to treat osteoporotic fractures. Osteodensitometry imaging techniques are not routinely available in acute operative settings, nor do they provide objective information on local bone properties specifically needed for the prognosis of implant stability.
- 29 March 2019
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 139 (7) , 991-998
Sagittal profile has a significant impact on the explantability of well-fixed cemented stems in revision knee arthroplasty: a biomechanical comparison study of five established knee implant models
Easy revisability is gaining increasingly in importance. The removal of well-fixed cemented stems is very demanding and is often associated with increased operative morbidity. Implant design may be here a decisive impact factor, and the best way to ascertain it is experimentally. Aim of this study is to assess different cemented stems of established knee revision implants in regard to their removal capability.
- 29 March 2019
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 139 (7) , 991-998
Sagittal profile has a significant impact on the explantability of well-fixed cemented stems in revision knee arthroplasty: a biomechanical comparison study of five established knee implant models
Easy revisability is gaining increasingly in importance. The removal of well-fixed cemented stems is very demanding and is often associated with increased operative morbidity. Implant design may be here a decisive impact factor, and the best way to ascertain it is experimentally. Aim of this study is to assess different cemented stems of established knee revision implants in regard to their removal capability.