Nhat Minh Dang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nhat Minh Dang has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Ming-Tzer Lin
Graduate Institute of Precision Engineering, National Chung Hsing University, Taichung, Taiwan
9 shared publications - Zhao-Ying Wang
Graduate Institute of Precision Engineering, National Chung Hsing University, Taichung 40749, Taiwan
4 shared publications - Terry Yuan-Fang Chen
Department of Mechanical Engineering, National Cheng Kung University, Tainan 70101, Taiwan
3 shared publications - Tra Anh Khoa Nguyen
Graduate Institute of Precision Engineering, National Chung Hsing University, Taichung 402, Taiwan
3 shared publications - Chi-Hang Lin
Graduate Institute of Precision Engineering, National Chung Hsing University, Taichung 402, Taiwan
2 shared publications - Zhao-Ying Wang
Graduate Institute of Precision Engineering, National Chung Hsing University Taichung, Taichung 402, Taiwan
2 shared publications
Latest Publications
- Open Access
- 16 November 2026
- Published by Ho Chi Minh City University of Technology and Engineering in Journal of Technical Education Science
Xử lý và đánh giá đặc trưng hóa học của mùn dừa dùng làm giá thể trồng cây
Nghiên cứu đánh giá tiềm năng sử dụng mùn dừa làm giá thể qua hàm lượng lignin và phenolic tổng tại ba thời điểm phơi – lưu trữ. Mùn dừa và xơ dừa được tách bằng máy băm vỏ dừa trục dao nghiêng. Lignin được xác định bằng phương pháp Klason thủy phân acid hai giai đoạn, gồm lignin không tan trong acid (AIL) đo theo khối lượng và lignin tan trong acid (ASL) đo bằng quang phổ; phenolic tổng liên quan đến tannin được xác định bằng Folin–Ciocalteu. Lignin tổng tăng theo thời gian lưu trữ do AIL tăng và ASL giảm, chủ yếu phản ánh sự làm giàu tương đối của lignin khi các thành phần kém bền phân hủy, dù chưa loại trừ khả năng lignin ngưng tụ một phần trong điều kiện phơi – lưu trữ tự nhiên. Đồng thời, hàm lượng chất chiết giảm, còn hàm lượng tro tăng nhẹ. Phenolic tổng trong dịch chiết tăng, cho thấy phơi kéo dài chưa đủ loại bỏ các hợp chất phenolic, bao gồm tannin. Khi loại bỏ chất chiết trước thủy phân, kết quả Klason tương đương giá trị lignin Klason đã công bố cho mùn dừa; Folin–Ciocalteu phản ánh tốt xu hướng biến đổi phenolic nhưng chưa đặc hiệu với tannin. Kết quả cung cấp dữ liệu ban đầu về biến đổi thành phần mùn dừa khi phơi – lưu trữ, hỗ trợ đánh giá tiếp khả năng làm giá thể trồng cây.
- 16 November 2026
- Published by Ho Chi Minh City University of Technology and Engineering in Journal of Technical Education Science
Open AccessXử lý và đánh giá đặc trưng hóa học của mùn dừa dùng làm giá thể trồng cây
Nghiên cứu đánh giá tiềm năng sử dụng mùn dừa làm giá thể qua hàm lượng lignin và phenolic tổng tại ba thời điểm phơi – lưu trữ. Mùn dừa và xơ dừa được tách bằng máy băm vỏ dừa trục dao nghiêng. Lignin được xác định bằng phương pháp Klason thủy phân acid hai giai đoạn, gồm lignin không tan trong acid (AIL) đo theo khối lượng và lignin tan trong acid (ASL) đo bằng quang phổ; phenolic tổng liên quan đến tannin được xác định bằng Folin–Ciocalteu. Lignin tổng tăng theo thời gian lưu trữ do AIL tăng và ASL giảm, chủ yếu phản ánh sự làm giàu tương đối của lignin khi các thành phần kém bền phân hủy, dù chưa loại trừ khả năng lignin ngưng tụ một phần trong điều kiện phơi – lưu trữ tự nhiên. Đồng thời, hàm lượng chất chiết giảm, còn hàm lượng tro tăng nhẹ. Phenolic tổng trong dịch chiết tăng, cho thấy phơi kéo dài chưa đủ loại bỏ các hợp chất phenolic, bao gồm tannin. Khi loại bỏ chất chiết trước thủy phân, kết quả Klason tương đương giá trị lignin Klason đã công bố cho mùn dừa; Folin–Ciocalteu phản ánh tốt xu hướng biến đổi phenolic nhưng chưa đặc hiệu với tannin. Kết quả cung cấp dữ liệu ban đầu về biến đổi thành phần mùn dừa khi phơi – lưu trữ, hỗ trợ đánh giá tiếp khả năng làm giá thể trồng cây.
- 16 April 2024
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 42 (3)
Materials’ properties of low temperature deposited Cu/W and Cu/Cr multilayer thin films using high power impulse magnetron sputtering
In this study, copper/tungsten (Cu/W) and copper/chromium (Cu/Cr) multilayers were created by stacking bilayer films in a 3:1 ratio, with layer thicknesses ranging from 400 to 800 nm, deposited on Si (100) substrates using high power impulse magnetron sputtering (HiPIMS). The microstructural and surface properties of these films were examined through x-ray diffraction, atomic force microscopy, and scanning electron microscopy. Electrical properties were assessed using a four-point probe, while mechanical properties were measured via nanoindentation. Both multilayer systems showed a decrease in the hardness accompanied by an increase in the elastic modulus with each stacking bilayer. The Cu/W system experienced a gradual hardness reduction (down to 19%), compared to the Cu/Cr system, which exhibited a similar decrease (14.5%). The Cu/W and Cu/Cr multilayer film samples consistently demonstrate a softer nature compared to their bilayer counterparts due to the influence of the underlying Cu soft layers. A distinctive surface smoothness in these multilayer systems correlates with the elastic modulus in a manner unlike that with hardness. These multilayer films also demonstrated altered electrical resistivity, enhancing our understanding and capabilities in fabricating films with an increased number of layers.
- 16 April 2024
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 42 (3)
Materials’ properties of low temperature deposited Cu/W and Cu/Cr multilayer thin films using high power impulse magnetron sputtering
In this study, copper/tungsten (Cu/W) and copper/chromium (Cu/Cr) multilayers were created by stacking bilayer films in a 3:1 ratio, with layer thicknesses ranging from 400 to 800 nm, deposited on Si (100) substrates using high power impulse magnetron sputtering (HiPIMS). The microstructural and surface properties of these films were examined through x-ray diffraction, atomic force microscopy, and scanning electron microscopy. Electrical properties were assessed using a four-point probe, while mechanical properties were measured via nanoindentation. Both multilayer systems showed a decrease in the hardness accompanied by an increase in the elastic modulus with each stacking bilayer. The Cu/W system experienced a gradual hardness reduction (down to 19%), compared to the Cu/Cr system, which exhibited a similar decrease (14.5%). The Cu/W and Cu/Cr multilayer film samples consistently demonstrate a softer nature compared to their bilayer counterparts due to the influence of the underlying Cu soft layers. A distinctive surface smoothness in these multilayer systems correlates with the elastic modulus in a manner unlike that with hardness. These multilayer films also demonstrated altered electrical resistivity, enhancing our understanding and capabilities in fabricating films with an increased number of layers.
- 15 April 2024
- Published by Elsevier in Surface and Coatings Technology
- Vol. 483
FIB-DIC ring-core measurement of the residual stress on HiPIMS W/Cu and Cr/Cu multilayer thin films
- 15 April 2024
- Published by Elsevier in Surface and Coatings Technology
- Vol. 483
FIB-DIC ring-core measurement of the residual stress on HiPIMS W/Cu and Cr/Cu multilayer thin films
- Open Access
- 29 September 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (19) , 2677
Effects of RF Magnetron Sputtering Power on the Mechanical Behavior of Zr-Cu-Based Metallic Glass Thin Films
Zirconium-based metallic glass films are promising materials for nanoelectronic and biomedical applications, but their mechanical behavior under different conditions is not well understood. This study investigates the effects of radio frequency (RF) power and test temperature on the nanostructure, morphology, and creep behavior of Zr55Cu30Al10Ni5 metallic glass films prepared by RF magnetron sputtering. The films were characterized by X-ray diffraction and microscopy, and their mechanical properties were measured by a bulge test system. The results show that the films were amorphous and exhibited a transition from noncolumnar to columnar morphology as the RF power increased from 75 W to 125 W. The columnar morphology reduced the creep resistance, Young’s modulus, residual stress, and hardness of the films. The creep behavior of the films was also influenced by the test temperature, with higher temperature leading to higher creep strain and lower creep stress. The findings of this study provide insights into the optimization of the sputtering parameters and the design of zirconium-based metallic glass films for various applications.
- 29 September 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (19) , 2677
Open AccessEffects of RF Magnetron Sputtering Power on the Mechanical Behavior of Zr-Cu-Based Metallic Glass Thin Films
Zirconium-based metallic glass films are promising materials for nanoelectronic and biomedical applications, but their mechanical behavior under different conditions is not well understood. This study investigates the effects of radio frequency (RF) power and test temperature on the nanostructure, morphology, and creep behavior of Zr55Cu30Al10Ni5 metallic glass films prepared by RF magnetron sputtering. The films were characterized by X-ray diffraction and microscopy, and their mechanical properties were measured by a bulge test system. The results show that the films were amorphous and exhibited a transition from noncolumnar to columnar morphology as the RF power increased from 75 W to 125 W. The columnar morphology reduced the creep resistance, Young’s modulus, residual stress, and hardness of the films. The creep behavior of the films was also influenced by the test temperature, with higher temperature leading to higher creep strain and lower creep stress. The findings of this study provide insights into the optimization of the sputtering parameters and the design of zirconium-based metallic glass films for various applications.
- 7 July 2022
- Published by Springer Nature in Experimental Mechanics
- Vol. 62 (8) , 1489-1499
Incremental FIB-DIC Ring-Core Methods for the Residual Stress Measurement of Bilayer Thin Films
- 7 July 2022
- Published by Springer Nature in Experimental Mechanics
- Vol. 62 (8) , 1489-1499
Incremental FIB-DIC Ring-Core Methods for the Residual Stress Measurement of Bilayer Thin Films
- Open Access
Mechanical Properties and Residual Stress Measurement of TiN/Ti Duplex Coating Using HiPIMS TiN on Cold Spray Ti
This study investigated the mechanical properties and the residual stress of high-power impulse magnetron sputtering (HiPIMS) titanium nitride (TiN) thin film capping on cold spray titanium (Ti) coating. This TiN/Ti duplex coating was deposited on the Ti substrate, and the cold spray titanium (Ti) coating was prepared in three cases with different numbers of layers. The study determined Young’s modulus, hardness, and roughness of TiN thin film and cold spray Ti coatings by nano-indentation and AFM. The residual stress measurement of TiN/Ti duplex coating was conducted using the ring-core drilling method. A focused ion beam (FIB) drilled the TiN/Ti duplex coating with various milling depth steps. The corresponding images were obtained with a scanning electron microscope (SEM). The relationship between surface deformations and relaxation stress after each milling depth step was obtained using the digital image correlation (DIC) method. The results showed TiN/Ti duplex coating exhibited excellent mechanical properties, and the residual stresses were not significantly changing with different Ti cold spray substrates, showing the feasibility of coating technology for the future applications in the aerospace industry.
Open AccessMechanical Properties and Residual Stress Measurement of TiN/Ti Duplex Coating Using HiPIMS TiN on Cold Spray Ti
This study investigated the mechanical properties and the residual stress of high-power impulse magnetron sputtering (HiPIMS) titanium nitride (TiN) thin film capping on cold spray titanium (Ti) coating. This TiN/Ti duplex coating was deposited on the Ti substrate, and the cold spray titanium (Ti) coating was prepared in three cases with different numbers of layers. The study determined Young’s modulus, hardness, and roughness of TiN thin film and cold spray Ti coatings by nano-indentation and AFM. The residual stress measurement of TiN/Ti duplex coating was conducted using the ring-core drilling method. A focused ion beam (FIB) drilled the TiN/Ti duplex coating with various milling depth steps. The corresponding images were obtained with a scanning electron microscope (SEM). The relationship between surface deformations and relaxation stress after each milling depth step was obtained using the digital image correlation (DIC) method. The results showed TiN/Ti duplex coating exhibited excellent mechanical properties, and the residual stresses were not significantly changing with different Ti cold spray substrates, showing the feasibility of coating technology for the future applications in the aerospace industry.
- Open Access
- 20 January 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (3) , 329
The Effects of Stresses and Interfaces on Texture Transformation in Silver Thin Films
Thin metal films are critical elements in nano- and micro-fabricated technologies. The texture orientation of thin films has a significant effect on applied devices. For Face-Centered Cubic (FCC) metal thin films, when the critical thickness is reached, the texture orientation can transform from (111) to (100) based on the model related to the balance between interfacial energy and strain energy. This research focused on the texture transformation of thin films under two conditions: (1) with or without an adhesion layer in the thin film and (2) with or without initial stress applied through a four-point bending load. In the experiment, two samples (silicon/silver and silicon/titanium/silver) were used to apply different initial stress/strain values and different annealing times. After annealing, an X-ray Diffractometer (XRD) was used to ascertain the preferred orientation of the thin films and the percentage of (111) and (100). Finally, Electron Back-Scattered Diffraction (EBSD) was used to observe the grain size of the thin films. The results showed that, regardless of the existence of an adhesion layer, texture transformation occurred, and this was relatively significant with Ti adhesion layers. Further, the initial stress was found to be small compared to the internal stress; thus, the initial stress imposed in the tests in this research was not significantly influenced by the texture transformation.
- 20 January 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (3) , 329
Open AccessThe Effects of Stresses and Interfaces on Texture Transformation in Silver Thin Films
Thin metal films are critical elements in nano- and micro-fabricated technologies. The texture orientation of thin films has a significant effect on applied devices. For Face-Centered Cubic (FCC) metal thin films, when the critical thickness is reached, the texture orientation can transform from (111) to (100) based on the model related to the balance between interfacial energy and strain energy. This research focused on the texture transformation of thin films under two conditions: (1) with or without an adhesion layer in the thin film and (2) with or without initial stress applied through a four-point bending load. In the experiment, two samples (silicon/silver and silicon/titanium/silver) were used to apply different initial stress/strain values and different annealing times. After annealing, an X-ray Diffractometer (XRD) was used to ascertain the preferred orientation of the thin films and the percentage of (111) and (100). Finally, Electron Back-Scattered Diffraction (EBSD) was used to observe the grain size of the thin films. The results showed that, regardless of the existence of an adhesion layer, texture transformation occurred, and this was relatively significant with Ti adhesion layers. Further, the initial stress was found to be small compared to the internal stress; thus, the initial stress imposed in the tests in this research was not significantly influenced by the texture transformation.
- Open Access
Use of Digital Image Correlation Method to Measure Bio-Tissue Deformation
Traditionally, strain gauge, extensometer, and reflection tracking markers have been used to measure the deformation of materials under loading. However, the anisotropy and inhomogeneity of most biological materials restricted the accessibility of the real strain field. Compared to the video extensometer, digital image correlation has the advantage of providing full-field displacement as well as strain information. In this study, a digital image correlation method (DIC) measurement system was employed for chicken breast bio-tissue deformation measurement. To increase the contrast for better correlation, a mixture of ground black pepper and white sesame was sprayed on the surface of samples. The first step was to correct the distorted image caused by the lens using the inverse distorted calibration method and then the influence of subset size and correlation criteria, sum of squared differences (SSD), and zero-normalized sum of squared differences (ZNSSD) were investigated experimentally for accurate measurement. Test results of the sample was translated along the horizontal direction from 0 mm to 3 mm, with an increment of 0.1 mm and the measurement result was compared, and the displacement set on the translation stage. The result shows that the error is less than 3%, and accurate measurement can be achieved with proper surface preparation, subset size, correlation criterion, and image correction. Detailed examination of the strain values show that the strain εx is proportional to the displacement of crosshead, but the strain εy indicates the viscoelastic behavior of tested bio-tissue. In addition, the tested bio-tissue’s linear birefringence extracted by a Mueller matrix polarimetry is for comparison and is in good agreement. As noted above, the integration of the optical parameter measurement system and the digital image correlation method is proposed in this paper to analyze the relationship between the strain changes and optical parameters of biological tissue, and thus the relative optic-stress coefficient can be significantly characterized if Young’s modulus of biological tissue is known.
Open AccessUse of Digital Image Correlation Method to Measure Bio-Tissue Deformation
Traditionally, strain gauge, extensometer, and reflection tracking markers have been used to measure the deformation of materials under loading. However, the anisotropy and inhomogeneity of most biological materials restricted the accessibility of the real strain field. Compared to the video extensometer, digital image correlation has the advantage of providing full-field displacement as well as strain information. In this study, a digital image correlation method (DIC) measurement system was employed for chicken breast bio-tissue deformation measurement. To increase the contrast for better correlation, a mixture of ground black pepper and white sesame was sprayed on the surface of samples. The first step was to correct the distorted image caused by the lens using the inverse distorted calibration method and then the influence of subset size and correlation criteria, sum of squared differences (SSD), and zero-normalized sum of squared differences (ZNSSD) were investigated experimentally for accurate measurement. Test results of the sample was translated along the horizontal direction from 0 mm to 3 mm, with an increment of 0.1 mm and the measurement result was compared, and the displacement set on the translation stage. The result shows that the error is less than 3%, and accurate measurement can be achieved with proper surface preparation, subset size, correlation criterion, and image correction. Detailed examination of the strain values show that the strain εx is proportional to the displacement of crosshead, but the strain εy indicates the viscoelastic behavior of tested bio-tissue. In addition, the tested bio-tissue’s linear birefringence extracted by a Mueller matrix polarimetry is for comparison and is in good agreement. As noted above, the integration of the optical parameter measurement system and the digital image correlation method is proposed in this paper to analyze the relationship between the strain changes and optical parameters of biological tissue, and thus the relative optic-stress coefficient can be significantly characterized if Young’s modulus of biological tissue is known.
- Open Access
Size Effects in Internal Friction of Nanocrystalline Aluminum Films
Al thin film is extensively used in micro-electromechanical systems (MEMS) and electronic interconnections; however, most previous research has concentrated on their quasi-static properties and applied their designs on larger scales. The present study designed a paddle-like cantilever specimen with metal films deposited on the upper surface to investigate the quasi-static properties of Al thin film at room temperature under high vacuum conditions at microscopic scales. Energy loss was determined using a decay technique in the oscillation amplitude of a vibrating structure following resonant excitation. Grain size and film thickness size were strictly controlled considering the quasi-static properties of the films. This study found that the internal friction of ultra-thin and thin Al films was more dependent on the grain boundaries than film thickness.
Open AccessSize Effects in Internal Friction of Nanocrystalline Aluminum Films
Al thin film is extensively used in micro-electromechanical systems (MEMS) and electronic interconnections; however, most previous research has concentrated on their quasi-static properties and applied their designs on larger scales. The present study designed a paddle-like cantilever specimen with metal films deposited on the upper surface to investigate the quasi-static properties of Al thin film at room temperature under high vacuum conditions at microscopic scales. Energy loss was determined using a decay technique in the oscillation amplitude of a vibrating structure following resonant excitation. Grain size and film thickness size were strictly controlled considering the quasi-static properties of the films. This study found that the internal friction of ultra-thin and thin Al films was more dependent on the grain boundaries than film thickness.
- Open Access
- 15 January 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (1) , 85
Measurement of Effects of Different Substrates on the Mechanical Properties of Submicron Titanium Nickel Shape Memory Alloy Thin Film Using the Bulge Test
This study investigated the effects of different substrates on the mechanical properties of Ti-60at%Ni shape memory alloys (SMA). Two types of samples were prepared for this experiment: (1) a Ti-60at%Ni deposited on SiNx, and (2) a Ti-60at%Ni deposited on SiNx/Cr; both had a 600 nm thick film of Ti-60at%Ni. Deposition was done using the physical vapor deposition (PVD) process, and the microstructural changes and crystallization phase changes were observed through scanning electron microscopy (SEM) and X-ray diffraction (XRD). The results showed that the TiNi thin film with a Cr adhesion layer had better mechanical properties. The bulge test showed that TiNi thin film with a Cr adhesion had a higher Young’s modulus and lower residual stress. From the thermal cycling experiment, it was found that the Cr adhesion layer buffered the mismatch between TiNi and SiNx. Additionally, the thermal cycling test was also used to measure the thermal expansion coefficient of the films, and the fatigue test showed that the Cr layer significantly improved the fatigue resistance of the TiNi film.
- 15 January 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (1) , 85
Open AccessMeasurement of Effects of Different Substrates on the Mechanical Properties of Submicron Titanium Nickel Shape Memory Alloy Thin Film Using the Bulge Test
This study investigated the effects of different substrates on the mechanical properties of Ti-60at%Ni shape memory alloys (SMA). Two types of samples were prepared for this experiment: (1) a Ti-60at%Ni deposited on SiNx, and (2) a Ti-60at%Ni deposited on SiNx/Cr; both had a 600 nm thick film of Ti-60at%Ni. Deposition was done using the physical vapor deposition (PVD) process, and the microstructural changes and crystallization phase changes were observed through scanning electron microscopy (SEM) and X-ray diffraction (XRD). The results showed that the TiNi thin film with a Cr adhesion layer had better mechanical properties. The bulge test showed that TiNi thin film with a Cr adhesion had a higher Young’s modulus and lower residual stress. From the thermal cycling experiment, it was found that the Cr adhesion layer buffered the mismatch between TiNi and SiNx. Additionally, the thermal cycling test was also used to measure the thermal expansion coefficient of the films, and the fatigue test showed that the Cr layer significantly improved the fatigue resistance of the TiNi film.