Abdul Raheem Junaidi
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Abdul Raheem Junaidi has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- K. Ram Chandra Murthy
BITS Pilani, Hyderabad Campus
3 shared publications - Udayashankar Shivaramakrishna
Department of Mechanical Engineering, VTU, Belgaum, India
3 shared publications - Aju Jo Sankarathil
Mechanical Engineering Department, Saintgits College of Engineering, Kottayam, India
2 shared publications Alla Gopala Krishna Gokhale
Apollo Hospital, Apollo Health City, Hyderabad, India
2 shared publicationsHarsha Sista
BITS Pilani, Hyderabad Campus
2 shared publications- K. Revanna
Department of Mechanical Engineering, Government Engineering College, Krishnarajapet, India
2 shared publications
Latest Publications
- 8 November 2025
- Published by Elsevier in Next Research
- Vol. 2 (4)
Experimental verification of newtonian fluid flow in proposed multi-functional laparoscopic forceps
- 8 November 2025
- Published by Elsevier in Next Research
- Vol. 2 (4)
Experimental verification of newtonian fluid flow in proposed multi-functional laparoscopic forceps
- 10 March 2025
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 150 (7) , 4851-4872
Influence of advanced composite phase change materials on thermal energy storage and thermal energy conversion
- 10 March 2025
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 150 (7) , 4851-4872
Influence of advanced composite phase change materials on thermal energy storage and thermal energy conversion
- Open Access
- 5 December 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 455, 02006
Experimental Findings and Analysis of a Split Unit Evaporative Cooler for Efficient and Eco-Friendly Cooling Applications
As the global energy demand surges, there is a pressing need to develop energy conservation methods to ensure future comfort requirements are met sustainably. Traditional air conditioners, employing vapor compression refrigeration systems, consume substantial power (around 1.5KW) and entail high costs. Alternatively, evaporative coolers offer a cost-effective and lower-power option for comfort maintenance. However, their drawback lies in the excessive humidity in the cooled air, leading to discomfort for individuals. To address this issue, our article focuses on designing and manufacturing a split cooling unit that efficiently cools the air without increasing its humidity. By recirculating the air through the split unit, we aim to maintain optimal room conditions for comfort. This becomes increasingly vital as inefficient building designs in India contribute to 20-25% of electricity wastage in government buildings, resulting in significant annual energy-related financial losses. Conventional heating, ventilation, and air conditioning (HVAC) systems further exacerbate the problem, consuming about 50% of building energy, mostly sourced from fossil fuels, rendering them environmentally unfriendly and unsustainable. Our split cooling unit seeks to provide an eco-friendly and sustainable solution to tackle this energy challenge.
- 5 December 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 455, 02006
Open AccessExperimental Findings and Analysis of a Split Unit Evaporative Cooler for Efficient and Eco-Friendly Cooling Applications
As the global energy demand surges, there is a pressing need to develop energy conservation methods to ensure future comfort requirements are met sustainably. Traditional air conditioners, employing vapor compression refrigeration systems, consume substantial power (around 1.5KW) and entail high costs. Alternatively, evaporative coolers offer a cost-effective and lower-power option for comfort maintenance. However, their drawback lies in the excessive humidity in the cooled air, leading to discomfort for individuals. To address this issue, our article focuses on designing and manufacturing a split cooling unit that efficiently cools the air without increasing its humidity. By recirculating the air through the split unit, we aim to maintain optimal room conditions for comfort. This becomes increasingly vital as inefficient building designs in India contribute to 20-25% of electricity wastage in government buildings, resulting in significant annual energy-related financial losses. Conventional heating, ventilation, and air conditioning (HVAC) systems further exacerbate the problem, consuming about 50% of building energy, mostly sourced from fossil fuels, rendering them environmentally unfriendly and unsustainable. Our split cooling unit seeks to provide an eco-friendly and sustainable solution to tackle this energy challenge.
- 21 July 2021
- Published by Springer Nature
- p. 437-449
Challenges in the Design of a Laparoscopic Surgical Forceps
- 21 July 2021
- Published by Springer Nature
- p. 437-449
Challenges in the Design of a Laparoscopic Surgical Forceps
- 17 June 2021
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 24 (16) , 1794-1806
Simulation of non-Newtonian flow of blood in a modified laparoscopic forceps used in minimally invasive surgery
During surgeries, blood often oozes out of the operated tissue and this has to be sucked out by the S–I device. Blood is more viscous than saline, the cleaning fluid is used in the S–I process. Therefore, for a more comprehensive CFD flow analysis of the improved forceps is simulated in the present work for different driving pressures. The resulting flow rate of blood is compared among the prospective designs and the S–I device currently in use. The new surgical forceps eliminates re-insertion of dissector with suction-irrigator and is reusable, multi-functional, non-toxic, corrosion resistant, toughened, and cost-effective.
- 17 June 2021
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 24 (16) , 1794-1806
Simulation of non-Newtonian flow of blood in a modified laparoscopic forceps used in minimally invasive surgery
During surgeries, blood often oozes out of the operated tissue and this has to be sucked out by the S–I device. Blood is more viscous than saline, the cleaning fluid is used in the S–I process. Therefore, for a more comprehensive CFD flow analysis of the improved forceps is simulated in the present work for different driving pressures. The resulting flow rate of blood is compared among the prospective designs and the S–I device currently in use. The new surgical forceps eliminates re-insertion of dissector with suction-irrigator and is reusable, multi-functional, non-toxic, corrosion resistant, toughened, and cost-effective.