VKVladimir Yu. Konev

Vladimir Yu. Konev

*This is an algorithmically generated author record based on publicly available information.

Vladimir Yu. Konev has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Investigation of bioresorbable materials remodeling in aseptic bone defect model in vivo

    by Божкова Светлана Анатольевна, Svetlana A. Bozhkova, Авдеев Александр Игоревич, Alexandr I. Avdeev, Конев Владимир Александрович, Vladimir A. Konev, Корнева Юлия Сергеевна, Yulia S. Korneva

    BACKGROUND: The choice of an optimal bone substitute material for bone defect reconstruction remains a significant challenge. Bioresorbable glass-ceramic materials, such as silicoaluminophosphate, are of great interest as alternatives to auto- and allografts due to their unique physicochemical properties. AIM: To conduct a comparative analysis of tissue reactions to the implantation of silicoaluminophosphate glass-ceramic material and a β-tricalcium phosphate-hydroxyapatite based bone graft substitute into an aseptic bone defect in an in vivo experiment. METHODS: The experiment was conducted on 12 legs of Chinchilla rabbits. A defect was created in the proximal tibia and filled with either silicoaluminophosphate (experimental group) or β-tricalcium phosphate-hydroxyapatite (comparison group). The follow-up period was 45 days, after which a histological examination of the implantation site was performed. RESULTS: Histological analysis at 45 days showed that in the silicoaluminophosphate group, osteogenesis occurred via "creeping substitution" with the formation of a tight bond between the material and the host bone. In the β-tricalcium phosphate-hydroxyapatite group, classical osteoconduction was observed, with the material being replaced by trabecular bone. Both materials demonstrated high biocompatibility and partial resorption. CONCLUSION: The silicoaluminophosphate material (biosital) exhibits pronounced osteoinductive properties comparable to foreign analogues and provides a rigid scaffold in the defect zone. These findings support the potential for further study of silicoaluminophosphate in the reconstruction of segmental long bone defects.

  • Coaxial Load for Absorbing High-Power Voltage Pulses Modulated by Microwave Oscillations

    by Vladimir Yu. Konev, Aleksei I. Klimov, Pavel V. Priputnev, Roman K. Sobyanin, Valery V. Barmin, Sergei N. Maltsev

    The article discusses several design options for a coaxial matched load operating in the range from 0 to 2 GHz. Ceramic thin-film resistors, series-connected carbon fiber tubes of a special design, and a cylindrical load made of polymer material placed in a caprolon case were used as resistors. The materials and design of the loads were selected in such a way that the DC load resistance was about 23 Ω, which corresponds to the wave resistance of the tested nonlinear gyromagnetic line. It is shown that various versions of resistors, together with the volume of a conductive liquid such as water, can be used as an element that absorbs video and radio pulses in laboratory samples of high-power gyromagnetic lines. During the experiments, it was found that, depending on the amplitude of the signals incident on the line, the loads behave differently. It is also shown that these load cases have high electrical strength and can be used in systems with a pulse repetition rate reaching tens of Hertz.

  • Influence on the Parameters of GaAs-based HG PCSS Switching in Lock-On Mode at Laser Radiation With a Wavelength of 355 nm and 1064 nm

    by Valerii V. Barmin, Vladimir Yu. Konev, Ilya V. Romanchenko

    In this paper, it has been experimentally found that the efficiency of HG PCSS switching based on GaAs:Cr is higher from radiation with a wavelength of 355 nm with an average front duration of 2.7 ns in comparison to triggered by an optical pulse with a wavelength of 1064 nm and a front duration of 11.6 ns. The difference in optical energy for 355 and 1064 nm is 14 times $(25\ \mu\mathbf{J}$ vs. $345\ \mu \mathbf{J}$ ) and in duration is 3 times (5.7 ns vs. 16 ns). The experiment was carried out at a charging voltage of ∼ 13.7 kV with output pulses with an amplitude of 6.6 kV and 5.9 kV, which corresponds to the PCSS resistance at the time of switching 2.3 and 7.7 Ohm with currents of 132 A and 118 A. Application of a laser pulse with a shorter wavelength PCSS switching leads to a 3-times decrease in PCSS resistance. The temporal characteristics of the output pulse obtained during the experiment for laser beam with wavelength of 1064 nm are the front duration of 4.3 ns and the pulse FWHM of 39.3 ns. Under switching by radiation with a wavelength of 355 nm, the duration of the front of the output pulse equals 6 ns, but the FWHM duration is 33 ns. A longer pulse front demonstrates an increased value of the inductance of the conducting channel, which accordingly indicates a decrease in its cross-section. These factors indicate a significant increase in conductivity when the key is irradiated at a wavelength of 355 nm.

  • Open Access

    High efficiency radio frequency pulse generation in a nonlinear corrugated coaxial transmission line with ferrite saturated by permanent magnets

    by P. Priputnev, I. Romanchenko, S. Maltsev, R. Sobyanin, V. Konev

    The work on the development of a generator of high-power, high-frequency pulses based on a nonlinear transmission line with saturated ferrite is presented. A feature of the generator is that the ferrite rings are saturated in the field of permanent magnets, unlike traditional generators with a solenoid wrapped around the transmission line. Due to the changed structure of the inner conductor, which is a corrugated conductor, the line has spatial dispersion. The paper demonstrates the generation of high-frequency pulses with a duration of up to 6 ns and a center frequency of 2.7 GHz. This pulse duration with a frequency above 2 GHz was not previously observed in traditional nonlinear transmission line geometry. The maximal peak power achieved was 70 MW for an incident voltage pulse of 90 kV. The energy efficiency of video pulse energy conversion into radio pulse was 6% [G. Kataev, Electromagnetic Shock Waves (Sov. Radio, Moscow, 1963)]. The paper discusses the performance of RF and microwave NiZn ferrites for the purposes of radio pulse generation.


  • Open Access

    The phase stability of nanosecond Gunn oscillators

    by Vasily Y Kozhevnikov, Andrey V Kozyrev, Vladimir Y Konev, Aleksey Klimov

    Introduction/purpose: Detailed theoretical and experimental studies have been carried out in order to investigate the problem of a phase stability in electrodynamically uncoupled Gunn oscillators. Methods: The influence of modulating pulse instabilities has been investigated by means of computer simulation in the framework of a nonlinear one-dimensional theoretical model of the GaAs Gunn diode semiconductor active region. Experimental observations were also conducted including microwave measurements and antenna far-field estimation. They confirm the main theoretical results and extend the key work conclusions. Results: It was shown that the initial phase of the microwave oscillation out of the Gunn oscillator is independent of internal noises of the semiconductor structure and can be fixed only by the modulating voltage pulse. Conclusion: Gunn-diodes based microwave oscillators were stabilized using the leading edge of the voltage pulse from the modulating power supply. These results open up serious prospects for designing antenna phased arrays based on Gunn oscillators without mutual feedback (electrodynamically independent).


  • Stable Operation of a Repetitively Pulsed X-Band Relativistic Backward Wave Oscillator

    by Vladislav V. Rostov, R. V. Tsygankov, P. V. Vykhodsev, V. Y. Konev, A. S. Stepchenko

    This paper describes a recent activity in the development of a high-power microwave source based on a modified relativistic backward wave oscillator that is driven by an advanced version of a SINUS-family accelerator using a double-width pulse-forming line insulated with a modern synthetic oil. The relatively compact source of microwave pulses (0.6 GW, 20 ns, 9.4 GHz) can operate at a 100 pps repetition rate in a batch mode with batches of duration up to 15 s. The long-term stability of the oscillator performances during 106 pulses was achieved due to the improved conditions for explosive emission of the graphite cathode and the use of a titanium slow wave structure. Both factors prevented the shortening of the microwave pulses. With a proper choice of the magnetic field strength and longitudinal distribution and of the position of the resonant reflector, the pulse-to-pulse deviation of the microwave power was reduced with sacrifice in efficiency, which decreased from a simulated maximum efficiency of 44% to 40% in the simulation and to 35 ± 4% in the experiment. At an accelerating voltage of 418 kV and a magnetic induction of 0.64 T at the cathode, the standard deviation of the microwave pulsed power could be close to the voltage deviation.


  • Open Access

    Experimental justification for clinical application of bone growth stimulators in traumatology and orthopaedics (a review)

    by R. R. Vreden National Medical Research Center, V.A. Konev, D.V. Labutin, S.A. Bozhkova, Scientific Department of Prevention and Treatment of Wound Infection

    Analysis of scientifi c publications devoted to effi cacy assessment and experimental justifi cation of cell technology and growth factors application for osteogenesis stimulation in clinical practice of traumatologists-orthopaedists.The search was performed for papers published in PubMed and E-library digital databases within the period of 2010-2020. The search filter was set to explore randomised clinical trials. Th e key words were: “platelet growth factor OR vascular endothelial growth factor OR bone morphogenetic proteins OR autologous bone marrow stromal cells AND bone defect AND human”. Works dated 2010-2020 were selected for analysis of experimental studies using the following key word combinations: “mesenchymal stromal cells AND osteogenesis OR bone regeneration”, “growth factors AND mesenchymal stromal cells AND osteogenesis OR bone regeneration”. In addition, essential literatures describing properties of multipotent mesenchymal stromal cells (MSCs) were cited as well as issues in their osteogenic diff erentiation. Despite the great number of experimental works related to cell technology application for bone growth stimulation, a large variety of unresolved issues associated with optimal means to create such cells, their cultivation and combined application with morphogenetic proteins and growth factors remains. Clinical application of rhBMP-2, PDGF has demonstrated effi cacy in complex treatment of patients with bone defects. Th erewith, growth factors may be effi caciously used in diff erent combinations with MSCs. In a number of cases, application of implants enriched with growth factors may become an alternative for autogenic grafts. To the present day, there is crucial defi cit in the number of works presenting results of randomised controlled clinical trials devoted to stimulation of bone tissue repair. The controversial results of the publications analysed may be based on a low number of patients enrolled. With consideration for active development of reparative medicine as a whole, further investigation of possibilities in bone growth stimulation with local application of cell-engineering constructions is considered to be a promising trend for traumatology and orthopaedics.


  • Open Access

    A nonlinear transmission line based on periodically placed silicon high voltage switches

    by Ilya V. Romanchenko, Vladimir Yu. Konev, Valery V. Barmin, Pavel V. Priputnev, Sergey N. Maltsev

    The generation of high-power nanosecond radio frequency pulses is obtained by means of sequential commutation of silicon high voltage switches periodically placed in a nonlinear transmission line. The coaxial transmission line had the inner conductor made in the form of a corrugated periodic structure. The dispersive characteristics of the transmission line were optimized for RF generation by an electromagnetic shock front using numerical simulation. In the experiment, nanosecond RF pulses at frequency near 1 GHz were obtained for 2 kV incident pulses. The peak-to-peak amplitude of the excited oscillations reached about 30% of the amplitude of the incident pulse.


  • Four channel high power rf source with beam steering based on gyromagnetic nonlinear transmission lines

    by I. V. Romanchenko, M. R. Ulmaskulov, K. A. Sharypov, S. A. Shunailov, V. G. Shpak, M. I. Yalandin, M. S. Pedos, S. N. Rukin, V. Yu. Konev, V. V. Rostov

    The synchronized operation of four gyromagnetic nonlinear transmission lines (NLTLs) was tested with a pulse repetition frequency up to 1 kHz during 1 s bursts. High voltage pulses with a duration of ∼5 ns from the solid state driver S-500 were split into four 48 Ω channels reaching about −200 kV in each channel with ∼10% variation in the amplitude. The maximum peak voltage at the NLTL output was within 220-235 kV with the maximum modulation depth of decaying oscillations up to 90% at the center frequency near 2.1 GHz. The relative delay between channels reached the half-period of the center frequency of oscillations. The associated beam steering by four element array of conical helical antennas was demonstrated in a horizontal plane at 17°. The effective potential of radiation reached 360 kV at the radiation axis. The effect of ferrite temperature on the shock wave velocity in gyromagnetic NLTL is observed.