Ibrahim Önder Yeniçeri
Ibrahim Önder Yeniçeri has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Emrah Doğan
Muğla Sıtkı Koçman Üniversitesi,Tıp Fakültesi
2 shared publications - Funda Dinç Elibol
Mugla Sitki Kocman Universitesi
2 shared publications Mehmet Deveer
Muğla Sıtkı Koçman University
2 shared publications- Nesat Cullu
MUĞLA SITKI KOÇMAN ÜNİVERSİTESİ, TIP FAKÜLTESİ
2 shared publications Neşat Çullu
Department of Radiology, Mugla Sıtkı Koçman University, Faculty of Medicine, Mugla, Turkey
2 shared publications- Alp Dinçer
Center for Neuroradiological Applications and Research Acibadem University Istanbul Turkey
1 shared publication
Latest Publications
- 29 April 2022
- Published by Mugla Sitki Kocman University in Muğla Sıtkı Koçman Üniversitesi Tıp Dergisi
- Vol. 9 (1) , 17-21
Serebral Kavernöz Malformasyonların Tanısında Duyarlılık Ağırlıklı ve Gre T2* Görüntüleme: 3 Tesla Deneyimimiz
Bu çalışma serebral kavernöz malformasyonların (SKM), SWI ve Gradient eko T2* (GRE T2*) görüntülerde saptanabilirliği ve lezyonların her iki sekanstaki boyutsal farklılıklarının karşılaştırılmasıdır. Çalışmamıza yaşları 14 ile 80 (42.4±17.58) arasında değişen toplam 57 SKM'li hasta (32 erkek, 25 kadın) dahil edildi. Kranial MR görüntülemede, rutin sekanslara ek olarak SWI ve GRE T2* görüntüleme yapıldı. SKM lezyonlarının sayısı, boyutu ve alınan sekansta görülebilirliği açısından retrospektif olarak tekrar değerlendirildi. SWI görüntülemede saptanmış SKM sayısı (n=97), GRE T2* görüntülerde saptananlara (n=69) göre yüksekti. Lezyonların medyan (min-max) boyutu, SWI görüntülerde 7.9 (3.7-45) mm, GRE T2* görüntülerde 7.7 (3.6-42) mm olup aradaki fark istatistiksel olarak anlamlıydı (p<0.001). Ayrıca çalışmamızda 7 olguda SKM’ye eşlik eden gelişimsel venöz anomali ve 4 olguda eşlik eden fokal tip yüzeyel siderozis saptandı. SKM’ye eşlik eden fokal tip yüzeyel siderozis bulgusu SWI görüntülemede daha keskin ve ayrıntılı izlendi. SKM düşünülen olgularda tanısal üstünlüğü nedeni ile rutin kranial MR görüntülemeye SWI sekansı eklenmesi literatürde pek çok çalışmada önerilmektedir. Biz bu çalışmada mevcut literatüre ek olarak, SWI sekansının GRE T2* sekansında alınan görüntülere kıyasla lezyonları morfolojik olarak daha büyük gösterdiğini saptadık. Ayrıca SWI görüntüleme, SKM’ye eşlik eden okkült vasküler malformasyon saptanmasında ve fokal tip yüzeyel siderozis tanısında GRE T2* görüntülemeye kıyasla kesin bir tanısal üstünlüğe sahiptir.
- 29 April 2022
- Published by Mugla Sitki Kocman University in Muğla Sıtkı Koçman Üniversitesi Tıp Dergisi
- Vol. 9 (1) , 17-21
Serebral Kavernöz Malformasyonların Tanısında Duyarlılık Ağırlıklı ve Gre T2* Görüntüleme: 3 Tesla Deneyimimiz
Bu çalışma serebral kavernöz malformasyonların (SKM), SWI ve Gradient eko T2* (GRE T2*) görüntülerde saptanabilirliği ve lezyonların her iki sekanstaki boyutsal farklılıklarının karşılaştırılmasıdır. Çalışmamıza yaşları 14 ile 80 (42.4±17.58) arasında değişen toplam 57 SKM'li hasta (32 erkek, 25 kadın) dahil edildi. Kranial MR görüntülemede, rutin sekanslara ek olarak SWI ve GRE T2* görüntüleme yapıldı. SKM lezyonlarının sayısı, boyutu ve alınan sekansta görülebilirliği açısından retrospektif olarak tekrar değerlendirildi. SWI görüntülemede saptanmış SKM sayısı (n=97), GRE T2* görüntülerde saptananlara (n=69) göre yüksekti. Lezyonların medyan (min-max) boyutu, SWI görüntülerde 7.9 (3.7-45) mm, GRE T2* görüntülerde 7.7 (3.6-42) mm olup aradaki fark istatistiksel olarak anlamlıydı (p<0.001). Ayrıca çalışmamızda 7 olguda SKM’ye eşlik eden gelişimsel venöz anomali ve 4 olguda eşlik eden fokal tip yüzeyel siderozis saptandı. SKM’ye eşlik eden fokal tip yüzeyel siderozis bulgusu SWI görüntülemede daha keskin ve ayrıntılı izlendi. SKM düşünülen olgularda tanısal üstünlüğü nedeni ile rutin kranial MR görüntülemeye SWI sekansı eklenmesi literatürde pek çok çalışmada önerilmektedir. Biz bu çalışmada mevcut literatüre ek olarak, SWI sekansının GRE T2* sekansında alınan görüntülere kıyasla lezyonları morfolojik olarak daha büyük gösterdiğini saptadık. Ayrıca SWI görüntüleme, SKM’ye eşlik eden okkült vasküler malformasyon saptanmasında ve fokal tip yüzeyel siderozis tanısında GRE T2* görüntülemeye kıyasla kesin bir tanısal üstünlüğe sahiptir.
- 20 November 2021
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 27 (6) , 796-801
The reliability and interobserver reproducibility of T2/FLAIR mismatch in the diagnosis of IDH-mutant astrocytomas
The reliability and reproducibility of T2-weighted imaging/fluid-attenuated inversion recovery (T2/FLAIR) mismatch were investigated in the diagnosis of isocitrate dehydrogenase (IDH) mutant astrocytoma between WHO grade II and III diffuse hemispheric gliomas. WHO grade II and grade III diffuse hemispheric gliomas (n=133) treated in our institute were included in the study. Pathological findings and molecular markers of the cases were reviewed with the criteria of WHO 2016. The finding of mismatch between T2-weighted and FLAIR images in preoperative magnetic resonance imaging (MRI) of the cases was evaluated by two different radiologists. The readers reviewed MRIs independently, blinded to the histopathologic diagnosis or molecular subset of tumors. The cases were classified as IDH-mutant astrocytoma, oligodendroglioma and IDH-wildtype (IDH-wt) astrocytoma according to molecular and genetic features. T2/FLAIR mismatch positivity was observed in 46 patients (34.6%). T2/FLAIR mismatch positivity was observed in 42 of 75 IDH-mutant astrocytomas (56%) and 4 of 43 oligodendrogliomas (9.30%), while it was not seen among IDH-wt astrocytomas (0/15, 0%). The T2/FLAIR mismatch ratio was significantly different between IDH-mutant astrocytomas (WHO grade II and grade III) and oligodendrogliomas (chi-square, p <0.05). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of T2/FLAIR mismatch in predicting IDH-mutant astrocytomas were 58.7%, 90.7%, 91.7%, 61.4%, and 70.3% respectively. Radiologist 1 diagnosed T2/FLAIR mismatch in 48 of 133 cases (36.1%) and Radiologist 2 in 66 of 133 cases (49.6%). The interrater agreement for the T2/FLAIR mismatch sign was 0.61 (p <0.05), 95% CI (0.55, 0.67). T2/FLAIR mismatch appears to be an important MRI finding in distinguishing IDH-mutant astrocytomas from other diffuse hemispheric gliomas. However, it should be kept in mind that T2/FLAIR mismatch sign can be seen in a minority of oligodendrogliomas besides IDH-mutant astrocytomas.
- 20 November 2021
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 27 (6) , 796-801
The reliability and interobserver reproducibility of T2/FLAIR mismatch in the diagnosis of IDH-mutant astrocytomas
The reliability and reproducibility of T2-weighted imaging/fluid-attenuated inversion recovery (T2/FLAIR) mismatch were investigated in the diagnosis of isocitrate dehydrogenase (IDH) mutant astrocytoma between WHO grade II and III diffuse hemispheric gliomas. WHO grade II and grade III diffuse hemispheric gliomas (n=133) treated in our institute were included in the study. Pathological findings and molecular markers of the cases were reviewed with the criteria of WHO 2016. The finding of mismatch between T2-weighted and FLAIR images in preoperative magnetic resonance imaging (MRI) of the cases was evaluated by two different radiologists. The readers reviewed MRIs independently, blinded to the histopathologic diagnosis or molecular subset of tumors. The cases were classified as IDH-mutant astrocytoma, oligodendroglioma and IDH-wildtype (IDH-wt) astrocytoma according to molecular and genetic features. T2/FLAIR mismatch positivity was observed in 46 patients (34.6%). T2/FLAIR mismatch positivity was observed in 42 of 75 IDH-mutant astrocytomas (56%) and 4 of 43 oligodendrogliomas (9.30%), while it was not seen among IDH-wt astrocytomas (0/15, 0%). The T2/FLAIR mismatch ratio was significantly different between IDH-mutant astrocytomas (WHO grade II and grade III) and oligodendrogliomas (chi-square, p <0.05). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of T2/FLAIR mismatch in predicting IDH-mutant astrocytomas were 58.7%, 90.7%, 91.7%, 61.4%, and 70.3% respectively. Radiologist 1 diagnosed T2/FLAIR mismatch in 48 of 133 cases (36.1%) and Radiologist 2 in 66 of 133 cases (49.6%). The interrater agreement for the T2/FLAIR mismatch sign was 0.61 (p <0.05), 95% CI (0.55, 0.67). T2/FLAIR mismatch appears to be an important MRI finding in distinguishing IDH-mutant astrocytomas from other diffuse hemispheric gliomas. However, it should be kept in mind that T2/FLAIR mismatch sign can be seen in a minority of oligodendrogliomas besides IDH-mutant astrocytomas.
- Open Access
- 30 April 2021
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF MEDICAL SCIENCES
- Vol. 51 (2) , 583-588
The effect of measurement area size on the reliability of myocardial iron load measurement in cardiac magnetic resonance imaging examinations of thalassemia patients
Background/aim: The aim of this study was to evaluate the intraobserver and interobserver reliability of cardiac T2* MRI measurements in different region of interest (ROI) sizes. Materials and methods: Cardiac T2* MRIs of 24 thalassemia major patients were evaluated. Two different ROI sizes were used for measurement. In the first measurement, an ROI approximately 5 mm in diameter was used in the interventricular septal myocardium. In the other method, the whole ventricular septal myocardium was used as the measurement. The intraobserver and interobserver variabilities were assessed with the intraclass correlation coefficient (ICC). Results: The measurement of the first observer, the ICC of the small-sized ROI (ssROI), was 0.869, and the measurement for the second observer, the ICC of the ssROI, was 0.659. The ICC of the whole-septal ROI (wsROI) was 0.991 for the first observer and 0.980 for the second observer. Interobserver variability, for the mean measurement, was 0.442 for the ICC of ssROI and 0.883 for the ICC of wsROI. Conclusion: For the evaluation of myocardial iron load with T2* MRI we suggest making measurements with ROI, including all of the interventricular septum, as a consequence of high intraobserver and interobserver consistency.
- 30 April 2021
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF MEDICAL SCIENCES
- Vol. 51 (2) , 583-588
Open AccessThe effect of measurement area size on the reliability of myocardial iron load measurement in cardiac magnetic resonance imaging examinations of thalassemia patients
Background/aim: The aim of this study was to evaluate the intraobserver and interobserver reliability of cardiac T2* MRI measurements in different region of interest (ROI) sizes. Materials and methods: Cardiac T2* MRIs of 24 thalassemia major patients were evaluated. Two different ROI sizes were used for measurement. In the first measurement, an ROI approximately 5 mm in diameter was used in the interventricular septal myocardium. In the other method, the whole ventricular septal myocardium was used as the measurement. The intraobserver and interobserver variabilities were assessed with the intraclass correlation coefficient (ICC). Results: The measurement of the first observer, the ICC of the small-sized ROI (ssROI), was 0.869, and the measurement for the second observer, the ICC of the ssROI, was 0.659. The ICC of the whole-septal ROI (wsROI) was 0.991 for the first observer and 0.980 for the second observer. Interobserver variability, for the mean measurement, was 0.442 for the ICC of ssROI and 0.883 for the ICC of wsROI. Conclusion: For the evaluation of myocardial iron load with T2* MRI we suggest making measurements with ROI, including all of the interventricular septum, as a consequence of high intraobserver and interobserver consistency.
- 9 April 2021
- Published by SAGE Publications in Journal of Diagnostic Medical Sonography
- Vol. 37 (4) , 321-326
The Relationship Between Posterior Communicating Artery Formation and Vertebral Artery Flow Parameters
Objectives: It is important to know the range of normal vertebral artery (VA) flow volume. Diminished VA flow volume is associated with vertebrobasilar insufficiency. The study aim was to investigate the relationship between the posterior communicating artery (PCoA) calibration and the VA flow parameters, in patients with no underlying cerebrovascular disease, below 50 years of age. Materials and Methods: The study population consisted of 102 cases below 50 years of age. The basilar artery (BA), internal carotid artery (ICA), and the PCoA calibrations were measured with magnetic resonance angiography. The VA flow parameters (maximum systolic velocity, end-diastolic velocity, mean velocity, VA flow volume, and VA calibration) were measured with duplex sonography. Results: There was no statistically significant difference between these two imaging groups, in terms of VA Vmax, VA flow volumes, VA calibrations, and BA calibrations. However, the mean right ICA and mean left ICA calibrations were significantly higher in group 2 than group 1 ( P < .01). There was no significant correlation between mean PCoA calibration and mean Vmax, mean calibration, and the total flow volume of vertebral arteries. Conclusion: The findings indicate that the VA flow rate may be relatively maintained, regardless of PCoA measurements in this study.
- 9 April 2021
- Published by SAGE Publications in Journal of Diagnostic Medical Sonography
- Vol. 37 (4) , 321-326
The Relationship Between Posterior Communicating Artery Formation and Vertebral Artery Flow Parameters
Objectives: It is important to know the range of normal vertebral artery (VA) flow volume. Diminished VA flow volume is associated with vertebrobasilar insufficiency. The study aim was to investigate the relationship between the posterior communicating artery (PCoA) calibration and the VA flow parameters, in patients with no underlying cerebrovascular disease, below 50 years of age. Materials and Methods: The study population consisted of 102 cases below 50 years of age. The basilar artery (BA), internal carotid artery (ICA), and the PCoA calibrations were measured with magnetic resonance angiography. The VA flow parameters (maximum systolic velocity, end-diastolic velocity, mean velocity, VA flow volume, and VA calibration) were measured with duplex sonography. Results: There was no statistically significant difference between these two imaging groups, in terms of VA Vmax, VA flow volumes, VA calibrations, and BA calibrations. However, the mean right ICA and mean left ICA calibrations were significantly higher in group 2 than group 1 ( P < .01). There was no significant correlation between mean PCoA calibration and mean Vmax, mean calibration, and the total flow volume of vertebral arteries. Conclusion: The findings indicate that the VA flow rate may be relatively maintained, regardless of PCoA measurements in this study.
- Open Access
- 1 January 2021
- Published by Termedia Sp. z.o.o. in Polish Journal of Cardio-Thoracic Surgery
- Vol. 18 (2) , 87-91
Evaluation of the morphological and clinical features of left anterior descending myocardial bridging with multi-detector computed tomography
Introduction The aim of the study was to assess the incidence, localization, depth, length of myocardial bridging (MB) with left anterior descending (LAD), systolic compression ratio, atherosclerotic plaque localization and degree of stenosis by 256-slice multi-detector computed tomography...
- 1 January 2021
- Published by Termedia Sp. z.o.o. in Polish Journal of Cardio-Thoracic Surgery
- Vol. 18 (2) , 87-91
Open AccessEvaluation of the morphological and clinical features of left anterior descending myocardial bridging with multi-detector computed tomography
Introduction The aim of the study was to assess the incidence, localization, depth, length of myocardial bridging (MB) with left anterior descending (LAD), systolic compression ratio, atherosclerotic plaque localization and degree of stenosis by 256-slice multi-detector computed tomography...
- 14 December 2020
- Published by SAGE Publications in Journal of Diagnostic Medical Sonography
- Vol. 37 (2) , 146-155
Contribution of Sonoelastographic Scoring to B-Mode Sonography in the Evaluation of Breast Masses
The study aims were to evaluate the contribution of sonoelastography to Breast Imaging Reporting, and Data System (BI-RADS) scoring of breast images. Two observers evaluated the BI-RADS category, Tsukuba score, and the strain index of 83 lesions of 73 consecutive patients. A new scoring system was established to evaluate the lesions by using the BI-RADS score, Tsukuba score, and strain index ratio. There was a statistically significant difference between the strain index value of benign (3.08 ± 2.71) and malignant group (4.62 ± 2.70) (P < .05). The sensitivity and specificity were 59.1% and 65.1% for the 3.12 cut-off value for the strain index. In the receiver operating characteristic (ROC) analysis, the area under the curve (AUC) of the only BI-RADS score was 0.834, both BT (BI-RADS + revised Tsukuba score) score and the total score (BI-RADS + revised Tsukuba score + strain index score) was 0.843. The interclass correlation coefficient for the two observers’ measurements of the strain index was weak, with .266 (P < .05). The potential contribution of sonoelastography on lesion characterization is still controversial. In this study, the agreement among the observers was inadequate, and the contribution of sonoelastography on BI-RADS classification was limited. In addition, in the daily practice of sonoelastograpic evaluation, the Tsukuba score, was easier to apply and should be used rather than strain index measurements.
- 14 December 2020
- Published by SAGE Publications in Journal of Diagnostic Medical Sonography
- Vol. 37 (2) , 146-155
Contribution of Sonoelastographic Scoring to B-Mode Sonography in the Evaluation of Breast Masses
The study aims were to evaluate the contribution of sonoelastography to Breast Imaging Reporting, and Data System (BI-RADS) scoring of breast images. Two observers evaluated the BI-RADS category, Tsukuba score, and the strain index of 83 lesions of 73 consecutive patients. A new scoring system was established to evaluate the lesions by using the BI-RADS score, Tsukuba score, and strain index ratio. There was a statistically significant difference between the strain index value of benign (3.08 ± 2.71) and malignant group (4.62 ± 2.70) (P < .05). The sensitivity and specificity were 59.1% and 65.1% for the 3.12 cut-off value for the strain index. In the receiver operating characteristic (ROC) analysis, the area under the curve (AUC) of the only BI-RADS score was 0.834, both BT (BI-RADS + revised Tsukuba score) score and the total score (BI-RADS + revised Tsukuba score + strain index score) was 0.843. The interclass correlation coefficient for the two observers’ measurements of the strain index was weak, with .266 (P < .05). The potential contribution of sonoelastography on lesion characterization is still controversial. In this study, the agreement among the observers was inadequate, and the contribution of sonoelastography on BI-RADS classification was limited. In addition, in the daily practice of sonoelastograpic evaluation, the Tsukuba score, was easier to apply and should be used rather than strain index measurements.
- 7 September 2017
- Published by VM Media Group sp. z o.o in Folia Morphologica
- Vol. 76 (3) , 420-425
Circle of Willis variations and artery diameter measurements in the Turkish population
Background: The aim of this study was to evaluate the frequency of COW variations and the measurements of the COW vessel diameters in the Turkish population. Materials and methods: The patient population for this single-centre, retrospective study was formed of patients who had brain MRA. A total of 384 subjects were included in the study. The 3D TOF technique was used for MRA imaging to evaluate the anatomy of the COW. Variations in the COW were recorded. The diameter of the critical arteries of the COW were measured. Results: Adult configuration of the COW was determined in 326 (85%) cases, fetal configuration in 50 (13%) cases and transitional configuration in 8 (2%) cases. The COW was normal in 328 (85.4%). In the remaining 56 (14.6%) cases, agenesis was determined in 62 vessels. The mean calibrations of the vessels were measured as 2.85 mm in the basilar artery, 4.24 mm in the right ICA, 4.32 mm in the left ICA, 1.58 mm in the right A1, 1.64 mm in the left A1, 2.13 mm in the right M1, 2.10 mm in the left M1, 1.80 mm in the right P1, 1.88 mm in the left P1, 1.12 mm in the right PCoA, and 1.12 mm in the left PCoA. Conclusions: COW variations may show geographic and ethnic differences. Knowledge of the frequency and types of variation in the population is important for neurosurgeons and in radiological interventional procedures as a guide for entry and in respect of collateral which could develop later. Background: The aim of this study was to evaluate the frequency of COW variations and the measurements of the COW vessel diameters in the Turkish population. Materials and methods: The patient population for this single-centre, retrospective study was formed of patients who had brain MRA. A total of 384 subjects were included in the study. The 3D TOF technique was used for MRA imaging to evaluate the anatomy of the COW. Variations in the COW were recorded. The diameter of the critical arteries of the COW were measured. Results: Adult configuration of the COW was determined in 326 (85%) cases, fetal configuration in 50 (13%) cases and transitional configuration in 8 (2%) cases. The COW was normal in 328 (85.4%). In the remaining 56 (14.6%) cases, agenesis was determined in 62 vessels. The mean calibrations of the vessels were measured as 2.85 mm in the basilar artery, 4.24 mm in the right ICA, 4.32 mm in the left ICA, 1.58 mm in the right A1, 1.64 mm in the left A1, 2.13 mm in the right M1, 2.10 mm in the left M1, 1.80 mm in the right P1, 1.88 mm in the left P1, 1.12 mm in the right PCoA, and 1.12 mm in the left PCoA. Conclusions: COW variations may show geographic and ethnic differences. Knowledge of the frequency and types of variation in the population is important for neurosurgeons and in radiological interventional procedures as a guide for entry and in respect of collateral which could develop later.
- 7 September 2017
- Published by VM Media Group sp. z o.o in Folia Morphologica
- Vol. 76 (3) , 420-425
Circle of Willis variations and artery diameter measurements in the Turkish population
Background: The aim of this study was to evaluate the frequency of COW variations and the measurements of the COW vessel diameters in the Turkish population. Materials and methods: The patient population for this single-centre, retrospective study was formed of patients who had brain MRA. A total of 384 subjects were included in the study. The 3D TOF technique was used for MRA imaging to evaluate the anatomy of the COW. Variations in the COW were recorded. The diameter of the critical arteries of the COW were measured. Results: Adult configuration of the COW was determined in 326 (85%) cases, fetal configuration in 50 (13%) cases and transitional configuration in 8 (2%) cases. The COW was normal in 328 (85.4%). In the remaining 56 (14.6%) cases, agenesis was determined in 62 vessels. The mean calibrations of the vessels were measured as 2.85 mm in the basilar artery, 4.24 mm in the right ICA, 4.32 mm in the left ICA, 1.58 mm in the right A1, 1.64 mm in the left A1, 2.13 mm in the right M1, 2.10 mm in the left M1, 1.80 mm in the right P1, 1.88 mm in the left P1, 1.12 mm in the right PCoA, and 1.12 mm in the left PCoA. Conclusions: COW variations may show geographic and ethnic differences. Knowledge of the frequency and types of variation in the population is important for neurosurgeons and in radiological interventional procedures as a guide for entry and in respect of collateral which could develop later. Background: The aim of this study was to evaluate the frequency of COW variations and the measurements of the COW vessel diameters in the Turkish population. Materials and methods: The patient population for this single-centre, retrospective study was formed of patients who had brain MRA. A total of 384 subjects were included in the study. The 3D TOF technique was used for MRA imaging to evaluate the anatomy of the COW. Variations in the COW were recorded. The diameter of the critical arteries of the COW were measured. Results: Adult configuration of the COW was determined in 326 (85%) cases, fetal configuration in 50 (13%) cases and transitional configuration in 8 (2%) cases. The COW was normal in 328 (85.4%). In the remaining 56 (14.6%) cases, agenesis was determined in 62 vessels. The mean calibrations of the vessels were measured as 2.85 mm in the basilar artery, 4.24 mm in the right ICA, 4.32 mm in the left ICA, 1.58 mm in the right A1, 1.64 mm in the left A1, 2.13 mm in the right M1, 2.10 mm in the left M1, 1.80 mm in the right P1, 1.88 mm in the left P1, 1.12 mm in the right PCoA, and 1.12 mm in the left PCoA. Conclusions: COW variations may show geographic and ethnic differences. Knowledge of the frequency and types of variation in the population is important for neurosurgeons and in radiological interventional procedures as a guide for entry and in respect of collateral which could develop later.
- 8 June 2016
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 7, 115-117
Fracture of the scapholunate coalition
- 8 June 2016
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 7, 115-117
Fracture of the scapholunate coalition