Kee-Deog Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kee-Deog Kim has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Wonse Park
Department of Advanced General Dentistry, Yonsei University College of Dentistry, Seoul, Republic of Korea
17 shared publications - Bock-Young Jung
Department of Advanced General Dentistry, College of Dentistry, Yonsei University, Seoul, Korea
4 shared publications Jin-Sun Jeong
School of Nursing and Rehabilitation, Cheeloo College of Medicine, Shandong University, Jinan, China
4 shared publicationsKyeong-Mee Park
Researcher, Department of Advanced General Dentistry, Yonsei University College of Dentistry, Seoul, Korea
3 shared publications- Kyeong-Seop Kim
Konkuk University
3 shared publications - Nan-Sim Pang
Department of Advanced General Dentistry, College of Dentistry, Yonsei University, Seoul, Korea
3 shared publications
Latest Publications
- Open Access
Comparative Analysis of Fracture Resistance of Endodontic Sealer Types and Filling Methods
With the advent of bioceramic sealers, sealers have become a more important filling material for endodontic treatment. When a solid sealer, rather than an elastic gutta-percha, occupies a significant portion of the root canal, it is unclear whether the tooth structure will be strengthened to withstand stress or whether the increased stiffness will transmit the load directly to the entire root, potentially causing root fracture. This study compared the fracture resistance and fracture patterns of roots filled with various root canal sealers, including bioceramic sealers, and each corresponding filling technique. Five groups (n = 10) were tested, including no endodontic treatment, no canal obturation, resin-based sealers with continuous-wave compaction, bioceramic sealers with single-cone technique, and mineral trioxide aggregate (MTA) orthograde obturation. The specimens were radiographed to assess the filling quality. After embedding the specimens in acrylic resin, fracture resistance was tested by a universal testing machine, and fracture features were examined microscopically. The results showed that the bioceramic sealer group using the single-cone technique had the highest fracture strength. Radiographic analysis revealed that achieving void-free filling was more difficult with MTA orthograde obturation compared to resin-based and bioceramic sealer groups. No significant variation in fracture features was observed across the groups.
Open AccessComparative Analysis of Fracture Resistance of Endodontic Sealer Types and Filling Methods
With the advent of bioceramic sealers, sealers have become a more important filling material for endodontic treatment. When a solid sealer, rather than an elastic gutta-percha, occupies a significant portion of the root canal, it is unclear whether the tooth structure will be strengthened to withstand stress or whether the increased stiffness will transmit the load directly to the entire root, potentially causing root fracture. This study compared the fracture resistance and fracture patterns of roots filled with various root canal sealers, including bioceramic sealers, and each corresponding filling technique. Five groups (n = 10) were tested, including no endodontic treatment, no canal obturation, resin-based sealers with continuous-wave compaction, bioceramic sealers with single-cone technique, and mineral trioxide aggregate (MTA) orthograde obturation. The specimens were radiographed to assess the filling quality. After embedding the specimens in acrylic resin, fracture resistance was tested by a universal testing machine, and fracture features were examined microscopically. The results showed that the bioceramic sealer group using the single-cone technique had the highest fracture strength. Radiographic analysis revealed that achieving void-free filling was more difficult with MTA orthograde obturation compared to resin-based and bioceramic sealer groups. No significant variation in fracture features was observed across the groups.
- 24 November 2023
- Published by Springer Nature in Oral Radiology
- Vol. 40  (2) , 93-108
Generative adversarial networks in dental imaging: a systematic review
Objectives This systematic review on generative adversarial network (GAN) architectures for dental image analysis provides a comprehensive overview to readers regarding current GAN trends in dental imagery and potential future applications. Methods Electronic databases (PubMed/MEDLINE, Scopus, Embase, and Cochrane Library) were searched to identify studies involving GANs for dental image analysis. Eighteen full-text articles describing the applications of GANs in dental imagery were reviewed. Risk of bias and applicability concerns were assessed using the QUADAS-2 tool. Results GANs were used for various imaging modalities, including two-dimensional and three-dimensional images. In dental imaging, GANs were utilized for tasks such as artifact reduction, denoising, and super-resolution, domain transfer, image generation for augmentation, outcome prediction, and identification. The generated images were incorporated into tasks such as landmark detection, object detection and classification. Because of heterogeneity among the studies, a meta-analysis could not be conducted. Most studies (72%) had a low risk of bias in all four domains. However, only three (17%) studies had a low risk of applicability concerns. Conclusions This extensive analysis of GANs in dental imaging highlighted their broad application potential within the dental field. Future studies should address limitations related to the stability, repeatability, and overall interpretability of GAN architectures. By overcoming these challenges, the applicability of GANs in dentistry can be enhanced, ultimately benefiting the dental field in its use of GANs and artificial intelligence.
- 24 November 2023
- Published by Springer Nature in Oral Radiology
- Vol. 40  (2) , 93-108
Generative adversarial networks in dental imaging: a systematic review
Objectives This systematic review on generative adversarial network (GAN) architectures for dental image analysis provides a comprehensive overview to readers regarding current GAN trends in dental imagery and potential future applications. Methods Electronic databases (PubMed/MEDLINE, Scopus, Embase, and Cochrane Library) were searched to identify studies involving GANs for dental image analysis. Eighteen full-text articles describing the applications of GANs in dental imagery were reviewed. Risk of bias and applicability concerns were assessed using the QUADAS-2 tool. Results GANs were used for various imaging modalities, including two-dimensional and three-dimensional images. In dental imaging, GANs were utilized for tasks such as artifact reduction, denoising, and super-resolution, domain transfer, image generation for augmentation, outcome prediction, and identification. The generated images were incorporated into tasks such as landmark detection, object detection and classification. Because of heterogeneity among the studies, a meta-analysis could not be conducted. Most studies (72%) had a low risk of bias in all four domains. However, only three (17%) studies had a low risk of applicability concerns. Conclusions This extensive analysis of GANs in dental imaging highlighted their broad application potential within the dental field. Future studies should address limitations related to the stability, repeatability, and overall interpretability of GAN architectures. By overcoming these challenges, the applicability of GANs in dentistry can be enhanced, ultimately benefiting the dental field in its use of GANs and artificial intelligence.
- Open Access
- 1 January 2023
- Published by XMLink in Journal of Dental Anesthesia and Pain Medicine
- Vol. 23  (3) , 173-177
Allergic reactions to local anesthetic mepivacaine in dental procedures: a case report
Nam Y, et al. J Dent Anesth Pain Med. 2023 Jun;23(3):173-177. https://doi.org/10.17245/jdapm.2023.23.3.173
- 1 January 2023
- Published by XMLink in Journal of Dental Anesthesia and Pain Medicine
- Vol. 23  (3) , 173-177
Open AccessAllergic reactions to local anesthetic mepivacaine in dental procedures: a case report
Nam Y, et al. J Dent Anesth Pain Med. 2023 Jun;23(3):173-177. https://doi.org/10.17245/jdapm.2023.23.3.173
- Open Access
- 1 January 2023
- Published by XMLink in Journal of Dental Anesthesia and Pain Medicine
- Vol. 23  (1) , 9-17
Evaluation of dental status using a questionnaire before administration of general anesthesia for the prevention of dental injuries
Lee K, et al. J Dent Anesth Pain Med. 2023 Feb;23(1):9-17. https://doi.org/10.17245/jdapm.2023.23.1.9
- 1 January 2023
- Published by XMLink in Journal of Dental Anesthesia and Pain Medicine
- Vol. 23  (1) , 9-17
Open AccessEvaluation of dental status using a questionnaire before administration of general anesthesia for the prevention of dental injuries
Lee K, et al. J Dent Anesth Pain Med. 2023 Feb;23(1):9-17. https://doi.org/10.17245/jdapm.2023.23.1.9
- Open Access
- 22 December 2022
- Published by Springer Nature in BMC Oral Health
- Vol. 22  (1) , 1-8
Efficacy of tooth brushing via a three-dimensional motion tracking system for dental plaque control in school children: a randomized controlled clinical trial
Background: School children are in a developmental period in which permanent teeth replace primary dentition. It is also a period with a high incidence of gingivitis and caries, which can be improved with adequate tooth brushing. Advances in information technology have led to the development of smart health devices that assist in tooth brushing. We compared the effectiveness of computer-assisted toothbrushing using a toothbrushing instruction (TBI) method called the smart toothbrush and smart mirror (STM) system with that of conventional TBI (verbal instructions) for plaque control in school children. Methods: This randomized controlled clinical trial analyzed and compared the reduction of the modified Quigley-Hein plaque index between the two methods in 42 school children. The participants were randomly assigned to the STM system group (n = 21) or conventional-TBI group (n = 21). The plaque indices were evaluated at baseline, immediately after TBI (day 0), and 1 week and 1 month after TBI. Results: The STM system and conventional TBI led to an average reduction of 40.50% and 40.57%, respectively, in whole mouth plaque. Reductions in the plaque indices within each tested time period were observed in both groups (P < 0.001), and the mean plaque reduction did not differ between the two groups (P = 0.44). Conclusions: The present study tested a computer assisted system for TBI, more studies are needed to confirm its usefulness in different objectives. Clinical relevance The computer-assisted STM system may be an alternative of TBI for children. Trial registration ClinicalTrials.gov (NCT04627324) Registered 13/11/2020—Retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT04627324.
- 22 December 2022
- Published by Springer Nature in BMC Oral Health
- Vol. 22  (1) , 1-8
Open AccessEfficacy of tooth brushing via a three-dimensional motion tracking system for dental plaque control in school children: a randomized controlled clinical trial
Background: School children are in a developmental period in which permanent teeth replace primary dentition. It is also a period with a high incidence of gingivitis and caries, which can be improved with adequate tooth brushing. Advances in information technology have led to the development of smart health devices that assist in tooth brushing. We compared the effectiveness of computer-assisted toothbrushing using a toothbrushing instruction (TBI) method called the smart toothbrush and smart mirror (STM) system with that of conventional TBI (verbal instructions) for plaque control in school children. Methods: This randomized controlled clinical trial analyzed and compared the reduction of the modified Quigley-Hein plaque index between the two methods in 42 school children. The participants were randomly assigned to the STM system group (n = 21) or conventional-TBI group (n = 21). The plaque indices were evaluated at baseline, immediately after TBI (day 0), and 1 week and 1 month after TBI. Results: The STM system and conventional TBI led to an average reduction of 40.50% and 40.57%, respectively, in whole mouth plaque. Reductions in the plaque indices within each tested time period were observed in both groups (P < 0.001), and the mean plaque reduction did not differ between the two groups (P = 0.44). Conclusions: The present study tested a computer assisted system for TBI, more studies are needed to confirm its usefulness in different objectives. Clinical relevance The computer-assisted STM system may be an alternative of TBI for children. Trial registration ClinicalTrials.gov (NCT04627324) Registered 13/11/2020—Retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT04627324.
- 1 August 2022
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 44  (8) , 1139-1146
Identifying the course of the greater palatine artery using intraoral ultrasonography: cohort study
Aims The greater palatine artery (GPA) is one of the most important anatomical structure for free gingival grafts or connective-tissue grafts during soft tissue surgery for dental implants. Several studies have identified the approximate location of the GPA, but it is impossible to detect its exact location during surgery due to large variability between individuals. The authors, therefore, investigated the course of the GPA using intraoral ultrasonography to determine the feasibility of using real-time nonionizing ultrasonography for implant surgery. Materials and methods This study included 40 healthy young participants. The courses of the GPA were identified using intraoral ultrasound probes from the first premolar to the second molar. The distance from the gingival margin to the GPA (GM-GPA) and the depth of the palatal gingiva from the GPA (PG-GPA) were measured by two independent examiners. Measurements were analyzed statistically, and interexaminer reliability was determined. Results The distance of the GM-GPA and the mean depth of the PG-GPA were 14.8 ± 1.6 mm and 4.10 ± 0.51 mm (mean ± SD), respectively. GM-GPA decreased when the GPA ran from the second molar to the first molar, and GM-GPA was significantly shorter in females (P < 0.05). PG-GPA increased when the GPA ran to the posterior teeth. Interexaminer measurement agreements were excellent, with intraclass correlation coefficient values of 0.983 and 0.918 for GM-GPA and PG-GPA, respectively. Conclusions Using an intraoral ultrasound probe, real-time GPA tracking is possible, which is expected to help reduce the possibility of bleeding during surgery.
- 1 August 2022
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 44  (8) , 1139-1146
Identifying the course of the greater palatine artery using intraoral ultrasonography: cohort study
Aims The greater palatine artery (GPA) is one of the most important anatomical structure for free gingival grafts or connective-tissue grafts during soft tissue surgery for dental implants. Several studies have identified the approximate location of the GPA, but it is impossible to detect its exact location during surgery due to large variability between individuals. The authors, therefore, investigated the course of the GPA using intraoral ultrasonography to determine the feasibility of using real-time nonionizing ultrasonography for implant surgery. Materials and methods This study included 40 healthy young participants. The courses of the GPA were identified using intraoral ultrasound probes from the first premolar to the second molar. The distance from the gingival margin to the GPA (GM-GPA) and the depth of the palatal gingiva from the GPA (PG-GPA) were measured by two independent examiners. Measurements were analyzed statistically, and interexaminer reliability was determined. Results The distance of the GM-GPA and the mean depth of the PG-GPA were 14.8 ± 1.6 mm and 4.10 ± 0.51 mm (mean ± SD), respectively. GM-GPA decreased when the GPA ran from the second molar to the first molar, and GM-GPA was significantly shorter in females (P < 0.05). PG-GPA increased when the GPA ran to the posterior teeth. Interexaminer measurement agreements were excellent, with intraclass correlation coefficient values of 0.983 and 0.918 for GM-GPA and PG-GPA, respectively. Conclusions Using an intraoral ultrasound probe, real-time GPA tracking is possible, which is expected to help reduce the possibility of bleeding during surgery.
- Open Access
- 1 January 2022
- Published by XMLink in Journal of Dental Anesthesia and Pain Medicine
- Vol. 22  (3) , 187-195
Foreign body aspiration and ingestion in dental clinic: a seven-year retrospective study
Huh J, et al. J Dent Anesth Pain Med. 2022 Jun;22(3):187-195. https://doi.org/10.17245/jdapm.2022.22.3.187
- 1 January 2022
- Published by XMLink in Journal of Dental Anesthesia and Pain Medicine
- Vol. 22  (3) , 187-195
Open AccessForeign body aspiration and ingestion in dental clinic: a seven-year retrospective study
Huh J, et al. J Dent Anesth Pain Med. 2022 Jun;22(3):187-195. https://doi.org/10.17245/jdapm.2022.22.3.187
- Open Access
- 10 December 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Efficacy of toothbrushing via a 3D motion tracking system for dental plaque control in schoolchildren: Randomized controlled trials (Preprint)
BACKGROUND Schoolchildren are in a developmental period whose permanent teeth replace primary dentition. It is also a period with a high incidence of gingivitis and caries, which can be improved with correct tooth brushing. Advances in information technology have led to the development of smart health devices that assist in tooth brushing. OBJECTIVE To compare the effectiveness of computer-assisted toothbrushing using a toothbrushing instruction (TBI) method called the smart toothbrush and smart mirror (STM) system with that of conventional TBI for plaque control in schoolchildren. METHODS This randomized controlled clinical trials analyzed and compared the reduction of the modified Quigley-Hein plaque index between the two methods in 42 schoolchildren. The participants were randomly assigned to an STM system group (n=21) or a conventional-TBI group (n=21). The plaque indexes were evaluated at baseline, immediately after TBI (day 0), and 1 week and 1 month after TBI. RESULTS The STM system and conventional TBI led to an average reduction of 40.50% and 40.57%, respectively, in whole mouth plaque. Reductions in the plaque indexes in each time period tested were observed in both groups (P<.001), and the mean plaque reduction did not differ between the two groups (P=.42). Non-inferiority was validated in the STM system for a limited time (immediately and 1 week) after TBI. CONCLUSIONS The computer-assisted STM system showed a similar efficacy for dental plaque control in children compared with conventional TBI. The STM system may be beneficial for maintaining oral hygiene by improving tooth brushing ability. CLINICALTRIAL ClinicalTrials.gov NCT04627324ï¼› https://clinicaltrials.gov/ct2/show/NCT04627324
- 10 December 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessEfficacy of toothbrushing via a 3D motion tracking system for dental plaque control in schoolchildren: Randomized controlled trials (Preprint)
BACKGROUND Schoolchildren are in a developmental period whose permanent teeth replace primary dentition. It is also a period with a high incidence of gingivitis and caries, which can be improved with correct tooth brushing. Advances in information technology have led to the development of smart health devices that assist in tooth brushing. OBJECTIVE To compare the effectiveness of computer-assisted toothbrushing using a toothbrushing instruction (TBI) method called the smart toothbrush and smart mirror (STM) system with that of conventional TBI for plaque control in schoolchildren. METHODS This randomized controlled clinical trials analyzed and compared the reduction of the modified Quigley-Hein plaque index between the two methods in 42 schoolchildren. The participants were randomly assigned to an STM system group (n=21) or a conventional-TBI group (n=21). The plaque indexes were evaluated at baseline, immediately after TBI (day 0), and 1 week and 1 month after TBI. RESULTS The STM system and conventional TBI led to an average reduction of 40.50% and 40.57%, respectively, in whole mouth plaque. Reductions in the plaque indexes in each time period tested were observed in both groups (P<.001), and the mean plaque reduction did not differ between the two groups (P=.42). Non-inferiority was validated in the STM system for a limited time (immediately and 1 week) after TBI. CONCLUSIONS The computer-assisted STM system showed a similar efficacy for dental plaque control in children compared with conventional TBI. The STM system may be beneficial for maintaining oral hygiene by improving tooth brushing ability. CLINICALTRIAL ClinicalTrials.gov NCT04627324ï¼› https://clinicaltrials.gov/ct2/show/NCT04627324
- Open Access
- 1 June 2018
- Published by The Korean Academy of Oral and Maxillofacial Implantology in The Korean Academy of Oral and Maxillofacial Implantology
- Vol. 22  (2) , 80-86
Assessment of Bone Quality in Pre-dental Implant Site Using Periapical, Panoramic and Computed Tomography
- 1 June 2018
- Published by The Korean Academy of Oral and Maxillofacial Implantology in The Korean Academy of Oral and Maxillofacial Implantology
- Vol. 22  (2) , 80-86
Open AccessAssessment of Bone Quality in Pre-dental Implant Site Using Periapical, Panoramic and Computed Tomography
- 15 January 2018
- Published by Springer Nature in Oral Radiology
- Vol. 35  (1) , 73-76
Foreign body removal assisted by an intraoral ultrasound probe
Ultrasonography has recently been applied to the field of oral and maxillofacial surgery because of its noninvasiveness and ease of use. However, traditional transducers are not used in the intraoral area because of their large size. A novel intraoral transducer was introduced with size, volume, and axis modifications. This new transducer allows the surgeon to approach the intraoral region during dental procedures. This report describes a case of successful removal of a foreign body using the newly developed intraoral ultrasound probe. Precise localization and minimally invasive removal of the foreign body using the intraoral transducer were simultaneously conducted. Because of its many advantages, this intraoral ultrasound transducer has the potential to be applied in oral and maxillofacial surgery.
- 15 January 2018
- Published by Springer Nature in Oral Radiology
- Vol. 35  (1) , 73-76
Foreign body removal assisted by an intraoral ultrasound probe
Ultrasonography has recently been applied to the field of oral and maxillofacial surgery because of its noninvasiveness and ease of use. However, traditional transducers are not used in the intraoral area because of their large size. A novel intraoral transducer was introduced with size, volume, and axis modifications. This new transducer allows the surgeon to approach the intraoral region during dental procedures. This report describes a case of successful removal of a foreign body using the newly developed intraoral ultrasound probe. Precise localization and minimally invasive removal of the foreign body using the intraoral transducer were simultaneously conducted. Because of its many advantages, this intraoral ultrasound transducer has the potential to be applied in oral and maxillofacial surgery.