Maria Eduarda Canellas de Castro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Maria Eduarda Canellas de Castro has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Alexandre Anderson de Sousa Munhoz Soares
Universidade de Brasília, Programa de Pós-Graduação em Ciências Médicas, Brasília, Distrito Federal, Brazil
2 shared publications - Augusta Luize Harff
University Hospital of Canoas, Universidade Luterana do Brasil, Brazil
2 shared publications - Ciro Martins Gomes
Universidade de Brasília, Brasil
2 shared publications - Gabriela Luíza Nogueira Vitral
Department of Pediatrics, Faculty of Medicine, Universidade Federal de Minas Gerais, Brazil
2 shared publications - Gabriela Silveira Neves
Hospital Sofia Feldman, Brazil. Department of Pediatrics, Faculty of Medicine, Universidade Federal de Minas Gerais, Brazil
2 shared publications - Gisele Lobo Pappa
Universidade Federal de Minas Gerais, Belo Horizonte, Brazil
2 shared publications
Latest Publications
- Open Access
- 14 March 2026
- Published by Elsevier in Immunology Letters
- Vol. 280, 107169
Baseline immune signatures are associated with prospective COVID-19 infection and clinical outcomes in healthcare workers: Evidence from a cohort study in Brazil
- 14 March 2026
- Published by Elsevier in Immunology Letters
- Vol. 280, 107169
Open AccessBaseline immune signatures are associated with prospective COVID-19 infection and clinical outcomes in healthcare workers: Evidence from a cohort study in Brazil
- Open Access
- 7 September 2022
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 24 (9) , e38727
Newborn Skin Maturity Medical Device Validation for Gestational Age Prediction: Clinical Trial
Background: Early access to antenatal care and high-cost technologies for pregnancy dating challenge early neonatal risk assessment at birth in resource-constrained settings. To overcome the absence or inaccuracy of postnatal gestational age (GA), we developed a new medical device to assess GA based on the photobiological properties of newborns’ skin and predictive models. Objective: This study aims to validate a device that uses the photobiological model of skin maturity adjusted to the clinical data to detect GA and establish its accuracy in discriminating preterm newborns. Methods: A multicenter, single-blinded, and single-arm intention-to-diagnosis clinical trial evaluated the accuracy of a novel device for the detection of GA and preterm newborns. The first-trimester ultrasound, a second comparator ultrasound, and data regarding the last menstrual period (LMP) from antenatal reports were used as references for GA at birth. The new test for validation was performed using a portable multiband reflectance photometer device that assessed the skin maturity of newborns and used machine learning models to predict GA, adjusted for birth weight and antenatal corticosteroid therapy exposure. Results: The study group comprised 702 pregnant women who gave birth to 781 newborns, of which 366 (46.9%) were preterm newborns. As the primary outcome, the GA as predicted by the new test was in line with the reference GA that was calculated by using the intraclass correlation coefficient (0.969, 95% CI 0.964-0.973). The paired difference between predicted and reference GAs was −1.34 days, with Bland-Altman limits of −21.2 to 18.4 days. As a secondary outcome, the new test achieved 66.6% (95% CI 62.9%-70.1%) agreement with the reference GA within an error of 1 week. This agreement was similar to that of comparator-LMP-GAs (64.1%, 95% CI 60.7%-67.5%). The discrimination between preterm and term newborns via the device had a similar area under the receiver operating characteristic curve (0.970, 95% CI 0.959-0.981) compared with that for comparator-LMP-GAs (0.957, 95% CI 0.941-0.974). In newborns with absent or unreliable LMPs (n=451), the intent-to-discriminate analysis showed correct preterm versus term classifications with the new test, which achieved an accuracy of 89.6% (95% CI 86.4%-92.2%), while the accuracy for comparator-LMP-GA was 69.6% (95% CI 65.3%-73.7%). Conclusions: The assessment of newborn’s skin maturity (adjusted by learning models) promises accurate pregnancy dating at birth, even without the antenatal ultrasound reference. Thus, the novel device could add value to the set of clinical parameters that direct the delivery of neonatal care in birth scenarios where GA is unknown or unreliable.
- 7 September 2022
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 24 (9) , e38727
Open AccessNewborn Skin Maturity Medical Device Validation for Gestational Age Prediction: Clinical Trial
Background: Early access to antenatal care and high-cost technologies for pregnancy dating challenge early neonatal risk assessment at birth in resource-constrained settings. To overcome the absence or inaccuracy of postnatal gestational age (GA), we developed a new medical device to assess GA based on the photobiological properties of newborns’ skin and predictive models. Objective: This study aims to validate a device that uses the photobiological model of skin maturity adjusted to the clinical data to detect GA and establish its accuracy in discriminating preterm newborns. Methods: A multicenter, single-blinded, and single-arm intention-to-diagnosis clinical trial evaluated the accuracy of a novel device for the detection of GA and preterm newborns. The first-trimester ultrasound, a second comparator ultrasound, and data regarding the last menstrual period (LMP) from antenatal reports were used as references for GA at birth. The new test for validation was performed using a portable multiband reflectance photometer device that assessed the skin maturity of newborns and used machine learning models to predict GA, adjusted for birth weight and antenatal corticosteroid therapy exposure. Results: The study group comprised 702 pregnant women who gave birth to 781 newborns, of which 366 (46.9%) were preterm newborns. As the primary outcome, the GA as predicted by the new test was in line with the reference GA that was calculated by using the intraclass correlation coefficient (0.969, 95% CI 0.964-0.973). The paired difference between predicted and reference GAs was −1.34 days, with Bland-Altman limits of −21.2 to 18.4 days. As a secondary outcome, the new test achieved 66.6% (95% CI 62.9%-70.1%) agreement with the reference GA within an error of 1 week. This agreement was similar to that of comparator-LMP-GAs (64.1%, 95% CI 60.7%-67.5%). The discrimination between preterm and term newborns via the device had a similar area under the receiver operating characteristic curve (0.970, 95% CI 0.959-0.981) compared with that for comparator-LMP-GAs (0.957, 95% CI 0.941-0.974). In newborns with absent or unreliable LMPs (n=451), the intent-to-discriminate analysis showed correct preterm versus term classifications with the new test, which achieved an accuracy of 89.6% (95% CI 86.4%-92.2%), while the accuracy for comparator-LMP-GA was 69.6% (95% CI 65.3%-73.7%). Conclusions: The assessment of newborn’s skin maturity (adjusted by learning models) promises accurate pregnancy dating at birth, even without the antenatal ultrasound reference. Thus, the novel device could add value to the set of clinical parameters that direct the delivery of neonatal care in birth scenarios where GA is unknown or unreliable.
- Open Access
- 13 April 2022
- Published by Springer Nature in Research Square
Newborn skin maturity model for gestational age prediction: a clinical trial for a novel medical device validation
Background: The early access to prenatal care and high-cost technologies for pregnancy dating challenge the early neonatal risks assessment at birth in resource-constrained settings. To overcome the absence or low accuracy of postnatal gestational age, we developed a frugal innovation based on the photobiological properties of the newborn's skin and predictive models. Methods: A multicenter single-blinding, and single-arm clinical trial intention-to-diagnosis evaluated the accuracy of a novel device to detect gestational age and preterm newborns. The first-trimester ultrasound (US), a second comparator US, and the last menstrual period (LMP) data from antenatal reports were the references for gestational age at birth. A portable multiband reflectance photometer assessed 781 newborns’ skin maturity and used machine learning models to predict gestational age, adjusted to birth weight and antenatal corticosteroid therapy exposure. Results: As the primary outcome, the predicted gestational by the new test had high agreement with the reference gestational age calculated with the intraclass correlation coefficient (0.970 [95%CI: 0.965, 0.974]) similar values to the comparator-US and better than the comparator-LMP gestational ages. As secondary outcomes, the new test achieved 97.7% (95%CI: 96.5%, 98.6%) agreement with the reference gestational age within one-week error. This value surpassed those of comparator-US (91.3% [95%CI: 89.2%, 93.1%]), and of comparator-LMP gestational ages (64.1% [60.7% to 67.5%]). Bland-Altman limits of the new test were -7.1 to 4.7 days. Prematurity discrimination with the novel device had the area under the receiver operating characteristic curve (AUROC) (0.998 [95%CI: 0.997, 1.000]), similar to comparator-US (0.996 [95% CI: 0.993, 0.999)]; and superior to comparator-LMP gestational ages (0.957 [95%CI:0.941, 0.974]). In newborns with absent or unreliable LMP (n=451), the intent-to-discriminate analysis showed correct classifications with the new test of 96.5% (95%CI: 94.3%, 98.0%), while with the comparator-LMP gestational age was 69.6% (95% CI: 65.3%, 73.7%). Interpretation: The assessment of the newborn's skin maturity adjusted by learning models promises accurate pregnancy dating at birth even without the antenatal ultrasound reference. Funding: Grand Challenges Exploration from the Bill & Melinda Gates Foundation, Fundação de Amparo a Pesquisa de Minas Gerais, Brazilian Ministry of Health, CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico.
- 13 April 2022
- Published by Springer Nature in Research Square
Open AccessNewborn skin maturity model for gestational age prediction: a clinical trial for a novel medical device validation
Background: The early access to prenatal care and high-cost technologies for pregnancy dating challenge the early neonatal risks assessment at birth in resource-constrained settings. To overcome the absence or low accuracy of postnatal gestational age, we developed a frugal innovation based on the photobiological properties of the newborn's skin and predictive models. Methods: A multicenter single-blinding, and single-arm clinical trial intention-to-diagnosis evaluated the accuracy of a novel device to detect gestational age and preterm newborns. The first-trimester ultrasound (US), a second comparator US, and the last menstrual period (LMP) data from antenatal reports were the references for gestational age at birth. A portable multiband reflectance photometer assessed 781 newborns’ skin maturity and used machine learning models to predict gestational age, adjusted to birth weight and antenatal corticosteroid therapy exposure. Results: As the primary outcome, the predicted gestational by the new test had high agreement with the reference gestational age calculated with the intraclass correlation coefficient (0.970 [95%CI: 0.965, 0.974]) similar values to the comparator-US and better than the comparator-LMP gestational ages. As secondary outcomes, the new test achieved 97.7% (95%CI: 96.5%, 98.6%) agreement with the reference gestational age within one-week error. This value surpassed those of comparator-US (91.3% [95%CI: 89.2%, 93.1%]), and of comparator-LMP gestational ages (64.1% [60.7% to 67.5%]). Bland-Altman limits of the new test were -7.1 to 4.7 days. Prematurity discrimination with the novel device had the area under the receiver operating characteristic curve (AUROC) (0.998 [95%CI: 0.997, 1.000]), similar to comparator-US (0.996 [95% CI: 0.993, 0.999)]; and superior to comparator-LMP gestational ages (0.957 [95%CI:0.941, 0.974]). In newborns with absent or unreliable LMP (n=451), the intent-to-discriminate analysis showed correct classifications with the new test of 96.5% (95%CI: 94.3%, 98.0%), while with the comparator-LMP gestational age was 69.6% (95% CI: 65.3%, 73.7%). Interpretation: The assessment of the newborn's skin maturity adjusted by learning models promises accurate pregnancy dating at birth even without the antenatal ultrasound reference. Funding: Grand Challenges Exploration from the Bill & Melinda Gates Foundation, Fundação de Amparo a Pesquisa de Minas Gerais, Brazilian Ministry of Health, CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico.
- Open Access
- 20 April 2021
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 10 (4) , e26477
Pregnancy Outcomes and Child Development Effects of SARS-CoV-2 Infection (PROUDEST Trial): Protocol for a Multicenter, Prospective Cohort Study
Background: A growing body of evidence suggests that SARS-COV-2 infection during pregnancy may affect maternal-fetal outcomes and possibly result in implications for the long-term development of SARS-CoV-2–exposed children. Objective: The PROUDEST (Pregnancy Outcomes and Child Development Effects of SARS-CoV-2 Infection Study) is a multicenter, prospective cohort study designed to elucidate the repercussions of COVID-19 for the global health of mothers and their children. Methods: The PROUDEST trial comprises 2 prospective, sequential substudies. The PREGNANT substudy will clinically assess the effects of SARS-CoV-2 infection on pregnancy, childbirth, and puerperium from a mechanistic standpoint to elucidate the pregnancy-related inflammatory and immunological phenomena underlying COVID-19. Pregnant women aged 18-40 years who have been exposed (proven with laboratory tests) to SARS-CoV-2 (group A; n=300) will be compared to control subjects with no laboratory evidence of in-pregnancy exposure to the virus (group B; n=300). Subjects exposed to other infections during pregnancy will be excluded. The BORN substudy is a long-term follow-up study that will assess the offspring of women who enrolled in the prior substudy. It will describe the effects of SARS-CoV-2 exposure during pregnancy on children’s growth, neurodevelopment, and metabolism from birth up to 5 years of age. It includes two comparison groups; group A (exposed; n=300) comprises children born from SARS-CoV-2–exposed pregnancies, and group B (controls; n=300) comprises children born from nonexposed mothers. Results: Recruitment began in July 2020, and as of January 2021, 260 pregnant women who were infected with SARS-CoV-2 during pregnancy and 160 newborns have been included in the study. Data analysis is scheduled to start after all data are collected. Conclusions: Upon completion of the study, we expect to have comprehensive data that will provide a better understanding of the effects of SARS-CoV-2 infection and related inflammatory and immunological processes on pregnancy, puerperium, and infancy. Our findings will inform clinical decisions regarding the care of SARS-CoV-2–exposed mothers and children and support the development of evidence-based public health policies. Trial Registration: Brazilian Register of Clinical Trials RBR65QXS2; https://ensaiosclinicos.gov.br/rg/RBR-65qxs2 International Registered Report Identifier (IRRID): DERR1-10.2196/26477
- 20 April 2021
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 10 (4) , e26477
Open AccessPregnancy Outcomes and Child Development Effects of SARS-CoV-2 Infection (PROUDEST Trial): Protocol for a Multicenter, Prospective Cohort Study
Background: A growing body of evidence suggests that SARS-COV-2 infection during pregnancy may affect maternal-fetal outcomes and possibly result in implications for the long-term development of SARS-CoV-2–exposed children. Objective: The PROUDEST (Pregnancy Outcomes and Child Development Effects of SARS-CoV-2 Infection Study) is a multicenter, prospective cohort study designed to elucidate the repercussions of COVID-19 for the global health of mothers and their children. Methods: The PROUDEST trial comprises 2 prospective, sequential substudies. The PREGNANT substudy will clinically assess the effects of SARS-CoV-2 infection on pregnancy, childbirth, and puerperium from a mechanistic standpoint to elucidate the pregnancy-related inflammatory and immunological phenomena underlying COVID-19. Pregnant women aged 18-40 years who have been exposed (proven with laboratory tests) to SARS-CoV-2 (group A; n=300) will be compared to control subjects with no laboratory evidence of in-pregnancy exposure to the virus (group B; n=300). Subjects exposed to other infections during pregnancy will be excluded. The BORN substudy is a long-term follow-up study that will assess the offspring of women who enrolled in the prior substudy. It will describe the effects of SARS-CoV-2 exposure during pregnancy on children’s growth, neurodevelopment, and metabolism from birth up to 5 years of age. It includes two comparison groups; group A (exposed; n=300) comprises children born from SARS-CoV-2–exposed pregnancies, and group B (controls; n=300) comprises children born from nonexposed mothers. Results: Recruitment began in July 2020, and as of January 2021, 260 pregnant women who were infected with SARS-CoV-2 during pregnancy and 160 newborns have been included in the study. Data analysis is scheduled to start after all data are collected. Conclusions: Upon completion of the study, we expect to have comprehensive data that will provide a better understanding of the effects of SARS-CoV-2 infection and related inflammatory and immunological processes on pregnancy, puerperium, and infancy. Our findings will inform clinical decisions regarding the care of SARS-CoV-2–exposed mothers and children and support the development of evidence-based public health policies. Trial Registration: Brazilian Register of Clinical Trials RBR65QXS2; https://ensaiosclinicos.gov.br/rg/RBR-65qxs2 International Registered Report Identifier (IRRID): DERR1-10.2196/26477