Ming-Hua Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ming-Hua Li has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Wu Wang
Institute of Diagnostic and Interventional Radiology, The Sixth Affiliated People’s Hospital, Shanghai Jiao Tong University, Shanghai, China
3 shared publications Bin-Xian Gu
Institute of Diagnostic and Interventional Radiology, The Sixth Affiliated People’s Hospital, Shanghai Jiao Tong University, Shanghai, China
2 shared publications- Yuehua Li
Department of Radiology, Shanghai Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
2 shared publications - Yuwu Zhao
Department of Neurology, Shanghai Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
2 shared publications - Aihua Liu
Beijing Neurosurgical Institute, Beijing Tiantan Hospital, Capital Medical University
1 shared publication Aizada Aldiyarova
Chemotherapy Department, Multidisciplinary Medical Center of the Akimat of Astana, Astana, 010009, Kazakhstan
1 shared publication
Latest Publications
- Open Access
- 1 August 2023
- Published by KEAI Publishing in Journal of Interventional Medicine
- Vol. 6 (3) , 116-120
Stent-assisted coiling of intracranial carotid ophthalmic segment aneurysm segment aneurysms: Long-term follow-up from a single center
To evaluate the efficacy of stent-assisted coiling (SAC) for the treatment of carotid ophthalmic segment aneurysm segment aneurysms (OSAs) of the internal carotid artery (ICA) through detailed long-term follow-up of a large patient cohort. We retrospectively analyzed 88 consecutive patients with OSAs between January 2009 and January 2020 at our center. Angiographic results were evaluated using the modified Raymond grading system and clinical outcomes were evaluated using the mRS scale. The primary endpoints were major aneurysm recurrence and poor clinical outcomes for at least 18 months of follow-up. The patients were asked to attend clinical follow-up assessments and possibly undergo DSA or MR via telephone. We enrolled 88 patients with 99 OSAs treated with coiling, of whom 76 were treated with SAC. The coiling procedures were successful in all 88 patients. Overall, complications occurred in 8 patients (9.1%). No procedure-related mortality was observed. 67 (76.1%) experienced immediate aneurysm occlusion at the end of the procedure. Long-term angiographic follow-up (18 months) was available in 45/88 aneurysms (51%) (average 18.7 ± 5.2 months). Four patients continued their follow-up for 5 years after initial aneurysm treatment. After a clinical follow-up time of 28.7 months (range, 12–51 months), 85 patients (95.5%) achieved favorable clinical outcomes (mRS scores of 0–2). This study indicates that SAC treatment is a safe and effective therapeutic alternative for ruptured and unruptured OSAs. The procedural risks are low with relatively long-term effectiveness.
- 1 August 2023
- Published by KEAI Publishing in Journal of Interventional Medicine
- Vol. 6 (3) , 116-120
Open AccessStent-assisted coiling of intracranial carotid ophthalmic segment aneurysm segment aneurysms: Long-term follow-up from a single center
To evaluate the efficacy of stent-assisted coiling (SAC) for the treatment of carotid ophthalmic segment aneurysm segment aneurysms (OSAs) of the internal carotid artery (ICA) through detailed long-term follow-up of a large patient cohort. We retrospectively analyzed 88 consecutive patients with OSAs between January 2009 and January 2020 at our center. Angiographic results were evaluated using the modified Raymond grading system and clinical outcomes were evaluated using the mRS scale. The primary endpoints were major aneurysm recurrence and poor clinical outcomes for at least 18 months of follow-up. The patients were asked to attend clinical follow-up assessments and possibly undergo DSA or MR via telephone. We enrolled 88 patients with 99 OSAs treated with coiling, of whom 76 were treated with SAC. The coiling procedures were successful in all 88 patients. Overall, complications occurred in 8 patients (9.1%). No procedure-related mortality was observed. 67 (76.1%) experienced immediate aneurysm occlusion at the end of the procedure. Long-term angiographic follow-up (18 months) was available in 45/88 aneurysms (51%) (average 18.7 ± 5.2 months). Four patients continued their follow-up for 5 years after initial aneurysm treatment. After a clinical follow-up time of 28.7 months (range, 12–51 months), 85 patients (95.5%) achieved favorable clinical outcomes (mRS scores of 0–2). This study indicates that SAC treatment is a safe and effective therapeutic alternative for ruptured and unruptured OSAs. The procedural risks are low with relatively long-term effectiveness.
- 1 February 2021
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 298 (2) , 374-381
Visualization of Thrombus Enhancement on Thin-Slab Maximum Intensity Projection of CT Angiography: An Imaging Sign for Predicting Stroke Source and Thrombus Compositions
Thrombus enhancement can be used to predict cardioembolic and cryptogenic strokes and to identify thrombus enhancement–positive thrombi, which have a higher fibrin-to-platelet fraction and a lower ... Background Thrombus enhancement (TE) in large vessel occlusion in patients with acute ischemic stroke can be visualized with thin-slab maximum intensity projection (TS-MIP) image reconstruction of ...
- 1 February 2021
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 298 (2) , 374-381
Visualization of Thrombus Enhancement on Thin-Slab Maximum Intensity Projection of CT Angiography: An Imaging Sign for Predicting Stroke Source and Thrombus Compositions
Thrombus enhancement can be used to predict cardioembolic and cryptogenic strokes and to identify thrombus enhancement–positive thrombi, which have a higher fibrin-to-platelet fraction and a lower ... Background Thrombus enhancement (TE) in large vessel occlusion in patients with acute ischemic stroke can be visualized with thin-slab maximum intensity projection (TS-MIP) image reconstruction of ...
- 1 September 2015
- Published by SAGE Publications in Acta Radiologica
- Vol. 56 (9) , 1119-1126
Timing of recanalization and outcome in ischemic-stroke patients treated with recombinant tissue plasminogen activator
Intravenous administration of recombinant tissue plasminogen activator (rtPA) is approved treatment for acute ischemic stroke P < 0.05). The 24-h, 7-d NHISS and mRS scores of DR patients were significantly higher than NR patients (P = 0.001, 0.002, 0.049, respectively). Three patients in the DR group died during follow-up. These data suggest that DR is associated with clinical deterioration. Patients treated with rtPA thrombolysis should be under close observation for 6–24 h. Corresponding treatment should be considered once DR appears.
- 1 September 2015
- Published by SAGE Publications in Acta Radiologica
- Vol. 56 (9) , 1119-1126
Timing of recanalization and outcome in ischemic-stroke patients treated with recombinant tissue plasminogen activator
Intravenous administration of recombinant tissue plasminogen activator (rtPA) is approved treatment for acute ischemic stroke P < 0.05). The 24-h, 7-d NHISS and mRS scores of DR patients were significantly higher than NR patients (P = 0.001, 0.002, 0.049, respectively). Three patients in the DR group died during follow-up. These data suggest that DR is associated with clinical deterioration. Patients treated with rtPA thrombolysis should be under close observation for 6–24 h. Corresponding treatment should be considered once DR appears.
- 1 May 2015
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 9 (3) , 202-208
Coronary competitive reverse flow: Imaging findings at CT angiography and correlation with invasive coronary angiography
- 1 May 2015
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 9 (3) , 202-208
Coronary competitive reverse flow: Imaging findings at CT angiography and correlation with invasive coronary angiography
- 1 May 2015
- Published by Wolters Kluwer Health in Neurosurgery Quarterly
- Vol. 25 (2) , 174-180
Correlation Between Angiographic Features and Subtypes of Fusiform Aneurysm of Vertebral and Basilar Artery
Objects: We retrospectively investigated the radiologic differences in subtypes of fusiform aneurysms (FA) of vertebral and basilar arteries. Methods: The study included 37 patients with 39 nonperipheral posterior circulation FAs detected by 3D-TOF-magnetic resonance angiography or by digital subtract angiography. Patient-specific and aneurysm-specific data were summarized. FAs were divided into 3 subtypes: focal FA (type I); classic dissecting aneurysm (type II); and dolichoectatic aneurysm (type III). Correlations between the subtypes and their angiographic features, including location, size, and rupture or not were analyzed. Results: Thirty-nine posterior FAs, including 28 aneurysms located at vertebral artery (VA), 8 at basilar artery (BA) and 3 at vertebrobasilar junction area, were detected in 37 patients. Twenty-one aneurysms in VA and 1 in BA were type II, among them 15 in VA and 1 in BA were ruptured. Focal FAs, including 7 in VA, 6 in BA, and 3 in vertebrobasilar junction area, were type I. One aneurysm in BA was type III. The subtypes of FAs were location specific (P=0.002). Ruptured FAs seemed closely associated with intracranial segment of VA (P=0.037). Conclusions: The subtypes of FAs were location specific, whereas ruptured FAs were mainly type II at VA without correlation with aneurysmal size.
- 1 May 2015
- Published by Wolters Kluwer Health in Neurosurgery Quarterly
- Vol. 25 (2) , 174-180
Correlation Between Angiographic Features and Subtypes of Fusiform Aneurysm of Vertebral and Basilar Artery
Objects: We retrospectively investigated the radiologic differences in subtypes of fusiform aneurysms (FA) of vertebral and basilar arteries. Methods: The study included 37 patients with 39 nonperipheral posterior circulation FAs detected by 3D-TOF-magnetic resonance angiography or by digital subtract angiography. Patient-specific and aneurysm-specific data were summarized. FAs were divided into 3 subtypes: focal FA (type I); classic dissecting aneurysm (type II); and dolichoectatic aneurysm (type III). Correlations between the subtypes and their angiographic features, including location, size, and rupture or not were analyzed. Results: Thirty-nine posterior FAs, including 28 aneurysms located at vertebral artery (VA), 8 at basilar artery (BA) and 3 at vertebrobasilar junction area, were detected in 37 patients. Twenty-one aneurysms in VA and 1 in BA were type II, among them 15 in VA and 1 in BA were ruptured. Focal FAs, including 7 in VA, 6 in BA, and 3 in vertebrobasilar junction area, were type I. One aneurysm in BA was type III. The subtypes of FAs were location specific (P=0.002). Ruptured FAs seemed closely associated with intracranial segment of VA (P=0.037). Conclusions: The subtypes of FAs were location specific, whereas ruptured FAs were mainly type II at VA without correlation with aneurysmal size.
- 9 August 2012
- Published by Springer Nature in La radiologia medica
- Vol. 118 (8) , 1379-1387
Evaluation of intracranial aneurysms with high-resolution MR angiography using single-artery highlighting technique: correlation with digital subtraction angiography
Purpose The authors investigated the effectiveness of high-resolution magnetic resonance angiography (MRA) using a single-artery highlighting technique for the accurate diagnosis of intracranial aneurysms at 3.0 T in a large cohort of patients with suspected intracranial aneurysms against the current gold standard, i.e. cerebral angiography. Methods A total of 307 patients with suspected aneurysms were referred for three-dimensional time-of-flight MRA (3D-TOF-MRA) prior to digital subtraction angiography (DSA). We summarised patient-based, aneurysm-based and vessel-based diagnostic performance parameters, namely, accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for detecting intracranial aneurysms with 3D-TOF-MRA. Interobserver agreement was calculated with the kappa (κ) statistic. Results Patient-based accuracy was 98.1%, sensitivity 99.5%, specificity 95.3%, PPV 97.6% and NPV 99% according to observer A; and 97.7%, 99.5%, 94.3%, 97.1% and 99%, respectively, according to observer B. Aneurysmbased accuracy was 98.3%, sensitivity 99.6%, specificity 95.2%, PPV 98.1% and NPV 99% according to observer A, and 98.0%, 99.6%, 94.3%, 97.7% and 99%, respectively, according to observer B. Vessel-based accuracy was 99.0%, sensitivity 99.6%, specificity 98.7%, PPV 97.8%, and NPV 99.7% according to observer A, and 98.9%, 99.6%, 98.5%, 97.3%, and 99.7%, respectively, according to observer B. Interobserver reading differences were not significant. The interobserver agreement was good, with a kappa (κ) value of 0.931 for patient-based evaluation, 0.934 for aneurysmbased evaluation and 0.953 for vessel-based evaluation. Conclusions Our results demonstrate the effectiveness of high-resolution MRA using a single-artery-highlighting technique for accurate diagnosis of intracranial aneurysms in a large cohort of patients with suspected aneurysms.
- 9 August 2012
- Published by Springer Nature in La radiologia medica
- Vol. 118 (8) , 1379-1387
Evaluation of intracranial aneurysms with high-resolution MR angiography using single-artery highlighting technique: correlation with digital subtraction angiography
Purpose The authors investigated the effectiveness of high-resolution magnetic resonance angiography (MRA) using a single-artery highlighting technique for the accurate diagnosis of intracranial aneurysms at 3.0 T in a large cohort of patients with suspected intracranial aneurysms against the current gold standard, i.e. cerebral angiography. Methods A total of 307 patients with suspected aneurysms were referred for three-dimensional time-of-flight MRA (3D-TOF-MRA) prior to digital subtraction angiography (DSA). We summarised patient-based, aneurysm-based and vessel-based diagnostic performance parameters, namely, accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for detecting intracranial aneurysms with 3D-TOF-MRA. Interobserver agreement was calculated with the kappa (κ) statistic. Results Patient-based accuracy was 98.1%, sensitivity 99.5%, specificity 95.3%, PPV 97.6% and NPV 99% according to observer A; and 97.7%, 99.5%, 94.3%, 97.1% and 99%, respectively, according to observer B. Aneurysmbased accuracy was 98.3%, sensitivity 99.6%, specificity 95.2%, PPV 98.1% and NPV 99% according to observer A, and 98.0%, 99.6%, 94.3%, 97.7% and 99%, respectively, according to observer B. Vessel-based accuracy was 99.0%, sensitivity 99.6%, specificity 98.7%, PPV 97.8%, and NPV 99.7% according to observer A, and 98.9%, 99.6%, 98.5%, 97.3%, and 99.7%, respectively, according to observer B. Interobserver reading differences were not significant. The interobserver agreement was good, with a kappa (κ) value of 0.931 for patient-based evaluation, 0.934 for aneurysmbased evaluation and 0.953 for vessel-based evaluation. Conclusions Our results demonstrate the effectiveness of high-resolution MRA using a single-artery-highlighting technique for accurate diagnosis of intracranial aneurysms in a large cohort of patients with suspected aneurysms.