Mrudang Mathur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mrudang Mathur has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
- Manuel K. Rausch
Department of Biomedical Engineering, The University of Texas at Austin, Austin, USA
12 shared publications - William D. Meador
Department of Biomedical Engineering, The University of Texas at Austin
7 shared publications - Marcin Malinowski
Department of Cardiac Surgery, Faculty of Medical Sciences in Katowice, Medical University of Silesia, 40-007 Katowice, Poland
6 shared publications Tomasz A. Timek
Division of Cardiothoracic Surgery, Corewell Health, Grand Rapids, MI, USA
6 shared publicationsTomasz Jazwiec
Division of Cardiothoracic Surgery, Corewell Health, Grand Rapids, MI, USA; Department of Cardiac, Vascular, and Endovascular Surgery and Transplantology, Medical University of Silesia in Katowice, Silesian Centre for Heart Disease, Zabrze, Poland
6 shared publications- Gabriella Paige Sugerman
Department of Biomedical Engineering, The University of Texas at Austin
4 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 154 (9) , 789-800
A Multitask Deep Learning Model for Pediatric Echocardiography Analysis
BACKGROUND: Congenital heart defects afflict ≈1% of all births worldwide. Although deep learning has shown significant promise in automating and improving adult echocardiography analysis, existing pediatric-based models are often limited to single tasks and specific echocardiographic views. To address this, we introduce EchoAI-Peds, a multitask deep learning model for pediatric echocardiography. Our model was developed using the most comprehensive set of pediatric labels to date and is designed to integrate information from multiple views simultaneously. METHODS: We trained a video-based vision transformer to simultaneously detect 28 congenital heart defects, structural and functional abnormalities, repairs, and interventions directly from complete pediatric echocardiography studies with multiple videos. Our model was developed using >700 000 videos derived from >12 000 studies performed at Stanford Medicine between 2014 and 2021. Specifically, our model was trained on 10 815 studies (median age, 8 [IQR 2–14] years; 45% female) and validated on 1294 studies (median age, 9 [IQR 2–15] years; 46% female). Model efficacy was tested on an internal held-out data set of 1336 studies from that same period. In addition, model generalizability was tested on a spatially and temporally distinct patient cohort at the Children’s Hospital of Philadelphia using 2121 studies performed between 2024 and 2025. RESULTS: Our model achieved macroaveraged area under the receiver operating characteristic curve (AUROC) values of 0.91 (95% CI, 0.90–0.92) on the internal test set (median age, 8 [IQR 2–14] years; 47% female) and AUROC values of 0.89 (95% CI, 0.88–0.90) on the external test set (median age, 6 [IQR 0.92–13] years; 44.4% female). Moreover, EchoAI-Peds significantly outperformed adult-based echocardiography foundation models trained on substantially larger data sets, including EchoCLIP (internal AUROC=0.58, 95% CI, 0.56–0.60; external AUROC=0.61, 95% CI, 0.59–0.62) and EchoPrime (internal AUROC=0.58, 95% CI, 0.57–0.61; external AUROC=0.60, 95% CI, 0.59–0.62). Finally, our model demonstrated robust performance across patient age, patient sex, and studies with varying numbers of videos. CONCLUSIONS: Our findings demonstrate the remarkable potential for multitask deep learning models to aid the interpretation of pediatric echocardiograms. In addition, our results underscore the need for models that are specifically tailored to pediatric populations.
- 1 September 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 154 (9) , 789-800
Open AccessA Multitask Deep Learning Model for Pediatric Echocardiography Analysis
BACKGROUND: Congenital heart defects afflict ≈1% of all births worldwide. Although deep learning has shown significant promise in automating and improving adult echocardiography analysis, existing pediatric-based models are often limited to single tasks and specific echocardiographic views. To address this, we introduce EchoAI-Peds, a multitask deep learning model for pediatric echocardiography. Our model was developed using the most comprehensive set of pediatric labels to date and is designed to integrate information from multiple views simultaneously. METHODS: We trained a video-based vision transformer to simultaneously detect 28 congenital heart defects, structural and functional abnormalities, repairs, and interventions directly from complete pediatric echocardiography studies with multiple videos. Our model was developed using >700 000 videos derived from >12 000 studies performed at Stanford Medicine between 2014 and 2021. Specifically, our model was trained on 10 815 studies (median age, 8 [IQR 2–14] years; 45% female) and validated on 1294 studies (median age, 9 [IQR 2–15] years; 46% female). Model efficacy was tested on an internal held-out data set of 1336 studies from that same period. In addition, model generalizability was tested on a spatially and temporally distinct patient cohort at the Children’s Hospital of Philadelphia using 2121 studies performed between 2024 and 2025. RESULTS: Our model achieved macroaveraged area under the receiver operating characteristic curve (AUROC) values of 0.91 (95% CI, 0.90–0.92) on the internal test set (median age, 8 [IQR 2–14] years; 47% female) and AUROC values of 0.89 (95% CI, 0.88–0.90) on the external test set (median age, 6 [IQR 0.92–13] years; 44.4% female). Moreover, EchoAI-Peds significantly outperformed adult-based echocardiography foundation models trained on substantially larger data sets, including EchoCLIP (internal AUROC=0.58, 95% CI, 0.56–0.60; external AUROC=0.61, 95% CI, 0.59–0.62) and EchoPrime (internal AUROC=0.58, 95% CI, 0.57–0.61; external AUROC=0.60, 95% CI, 0.59–0.62). Finally, our model demonstrated robust performance across patient age, patient sex, and studies with varying numbers of videos. CONCLUSIONS: Our findings demonstrate the remarkable potential for multitask deep learning models to aid the interpretation of pediatric echocardiograms. In addition, our results underscore the need for models that are specifically tailored to pediatric populations.
- Top Cited PapersOpen Access
- 25 March 2026
- Published by Springer Nature in Nature Biomedical Engineering
- p. 1-16
A generalizable deep learning system for cardiac MRI
Cardiac MRI allows for a comprehensive assessment of myocardial structure, function and tissue characteristics. Here we describe a foundational vision system for cardiac MRI, capable of representing the breadth of human cardiovascular disease and health. Our deep-learning model is trained via self-supervised contrastive learning, in which visual concepts in cine-sequence cardiac MRI scans are learned from the raw text of the accompanying radiology reports. We train and evaluate our model on data from four large academic clinical institutions in the United States. We additionally showcase the performance of our models on the UK BioBank and two additional publicly available external datasets. We explore emergent capabilities of our system and demonstrate remarkable performance across a range of tasks, including the problem of left-ventricular ejection fraction regression and the diagnosis of 39 different conditions such as cardiac amyloidosis and hypertrophic cardiomyopathy. We show that our deep-learning system is capable of not only contextualizing the staggering complexity of human cardiovascular disease but can be directed towards clinical problems of interest, yielding impressive, clinical-grade diagnostic accuracy with a fraction of the training data typically required for such tasks.
- 25 March 2026
- Published by Springer Nature in Nature Biomedical Engineering
- p. 1-16
Top Cited PapersOpen AccessA generalizable deep learning system for cardiac MRI
Cardiac MRI allows for a comprehensive assessment of myocardial structure, function and tissue characteristics. Here we describe a foundational vision system for cardiac MRI, capable of representing the breadth of human cardiovascular disease and health. Our deep-learning model is trained via self-supervised contrastive learning, in which visual concepts in cine-sequence cardiac MRI scans are learned from the raw text of the accompanying radiology reports. We train and evaluate our model on data from four large academic clinical institutions in the United States. We additionally showcase the performance of our models on the UK BioBank and two additional publicly available external datasets. We explore emergent capabilities of our system and demonstrate remarkable performance across a range of tasks, including the problem of left-ventricular ejection fraction regression and the diagnosis of 39 different conditions such as cardiac amyloidosis and hypertrophic cardiomyopathy. We show that our deep-learning system is capable of not only contextualizing the staggering complexity of human cardiovascular disease but can be directed towards clinical problems of interest, yielding impressive, clinical-grade diagnostic accuracy with a fraction of the training data typically required for such tasks.
- Open Access
Understanding the Mechanisms Behind the Annuloplasty Effect in Tricuspid Valve TEER: A Computational Study
Background: An annuloplasty effect has been observed following tricuspid transcatheter edge-to-edge repair (TEER) and has been shown to have a therapeutic benefit. However, the mechanisms underlying the annuloplasty effect remain unknown. Objectives: We investigate the impact of TEER-induced annular forces on the annuloplasty effect. Additionally, we explored the impact of clip size, clip orientation, leaflet pair, and leaflet site on TEER-induced annular forces. Methods: We simulated 36 TEER repairs in finite element models of three human tricuspid valves. We used either a NTW or XTW TriClip. The clip was placed between either the anterior-septal or anterior-posterior leaflet pairs, in either the central or near-annulus site. For each scenario, we quantified the reduction in annular area, septal-lateral (SL) diameter, and anterior-posterior (AP) diameter. We also report the total annular force, orientation of maximum annular force, total papillary muscle force, leaflet stress, and coaptation area ratio following TEER. Results: TEER induced annular forces, which strongly predicted the annuloplasty effect as measured by reduction in annular area and SL diameter. The maximum annular force aligned with the orientation of the clip. Furthermore, XTW clips induced more annular force and leaflet stress than NTW clips. A central anterior-posterior site induced more force than a near-annulus anterior-posterior site, but showed no difference from an anterior-septal pair. Conclusions: TEER procedural parameters, such as clip size and site, strongly influence the magnitude of induced annular forces, which, in turn, correlate with the degree of annuloplasty effect.
Open AccessUnderstanding the Mechanisms Behind the Annuloplasty Effect in Tricuspid Valve TEER: A Computational Study
Background: An annuloplasty effect has been observed following tricuspid transcatheter edge-to-edge repair (TEER) and has been shown to have a therapeutic benefit. However, the mechanisms underlying the annuloplasty effect remain unknown. Objectives: We investigate the impact of TEER-induced annular forces on the annuloplasty effect. Additionally, we explored the impact of clip size, clip orientation, leaflet pair, and leaflet site on TEER-induced annular forces. Methods: We simulated 36 TEER repairs in finite element models of three human tricuspid valves. We used either a NTW or XTW TriClip. The clip was placed between either the anterior-septal or anterior-posterior leaflet pairs, in either the central or near-annulus site. For each scenario, we quantified the reduction in annular area, septal-lateral (SL) diameter, and anterior-posterior (AP) diameter. We also report the total annular force, orientation of maximum annular force, total papillary muscle force, leaflet stress, and coaptation area ratio following TEER. Results: TEER induced annular forces, which strongly predicted the annuloplasty effect as measured by reduction in annular area and SL diameter. The maximum annular force aligned with the orientation of the clip. Furthermore, XTW clips induced more annular force and leaflet stress than NTW clips. A central anterior-posterior site induced more force than a near-annulus anterior-posterior site, but showed no difference from an anterior-septal pair. Conclusions: TEER procedural parameters, such as clip size and site, strongly influence the magnitude of induced annular forces, which, in turn, correlate with the degree of annuloplasty effect.
- 4 April 2025
- Published by Elsevier in Acta Biomaterialia
- Vol. 198, 234-244
Tricuspid valve leaflet remodeling in sheep with biventricular heart failure: A comparison between leaflets
- 4 April 2025
- Published by Elsevier in Acta Biomaterialia
- Vol. 198, 234-244
Tricuspid valve leaflet remodeling in sheep with biventricular heart failure: A comparison between leaflets
- 2 February 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 152, 106453
Leaflet remodeling reduces tricuspid valve function in a computational model
- 2 February 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 152, 106453
Leaflet remodeling reduces tricuspid valve function in a computational model
- Open Access
- 9 January 2024
- Published by Elsevier in Data in Brief
- Vol. 52, 110051
Geometric data of commercially available tricuspid valve annuloplasty devices
- 9 January 2024
- Published by Elsevier in Data in Brief
- Vol. 52, 110051
Open AccessGeometric data of commercially available tricuspid valve annuloplasty devices
- 4 October 2023
- Published by Elsevier in Acta Biomaterialia
- Vol. 171, 155-165
Untangling the mechanisms of pulmonary arterial hypertension-induced right ventricular stiffening in a large animal model
- 4 October 2023
- Published by Elsevier in Acta Biomaterialia
- Vol. 171, 155-165
Untangling the mechanisms of pulmonary arterial hypertension-induced right ventricular stiffening in a large animal model
- 2 June 2022
- Published by Elsevier in Extreme Mechanics Letters
- Vol. 55
Biomechanical phenotyping of minuscule soft tissues: An example in the rodent tricuspid valve
- 2 June 2022
- Published by Elsevier in Extreme Mechanics Letters
- Vol. 55
Biomechanical phenotyping of minuscule soft tissues: An example in the rodent tricuspid valve
- 24 May 2022
- Published by Springer Nature in Engineering with Computers
- Vol. 38 (5) , 3835-3848
Texas TriValve 1.0 : a reverse-engineered, open model of the human tricuspid valve
- 24 May 2022
- Published by Springer Nature in Engineering with Computers
- Vol. 38 (5) , 3835-3848
Texas TriValve 1.0 : a reverse-engineered, open model of the human tricuspid valve
- 15 December 2020
- Published by Elsevier in Acta Biomaterialia
- Vol. 123, 154-166
Right ventricular myocardial mechanics: Multi-modal deformation, microstructure, modeling, and comparison to the left ventricle
- 15 December 2020
- Published by Elsevier in Acta Biomaterialia
- Vol. 123, 154-166
Right ventricular myocardial mechanics: Multi-modal deformation, microstructure, modeling, and comparison to the left ventricle