Xiaoguang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xiaoguang Li has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Kazutaka Mitsuishi
Transmission Electron Microscopy Analysis Station, National Institute for Materials Science (NIMS) , 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047, Japan
2 shared publications- Masaki Takeguchi
Research Center for Energy and Environmental Materials National Institute for Materials Science Tsukuba Ibaraki Japan
2 shared publications - Guang Jin
Zhengzhou Railway Vocational & Technical College, Zhengzhou, Henan 451460, China
1 shared publication - Kazutaka Mitsuishi
Center for Basic Research on Materials, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki, Japan
1 shared publication Masaki Takeguchi
National Institute for Materials Science (NIMS) , Sengen 1-2-1, Tsukuba, Japan
1 shared publication
Latest Publications
- Open Access
- 20 April 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (SD) , SD1021
High-resolution STEM observation of the dynamics of Pt nanoparticles in a liquid
The dynamics of Pt nanoparticles (NPs) in water are observed by high-resolution scanning transmission electron microscopy with a home-made static sandwich-type liquid cell (LC). Carbon is coated on both sides of the membrane windows of the LC to make them conductive. The slow motion of Pt NPs in thin water droplets enables us to acquire high-resolution scanning transmission electron microscopy images. Using a dose rate of 3 × 10 5 e nm −2 s, some Pt NPs with a diameter of less than 2 nm disappear into the water, some move around, and others repeatedly attach to and detach from each other. The density of Pt NPs larger than 2 nm remains unchanged with further observation. However, by increasing the dose rate to 5.3 × 10 5 e nm −2 s, the Pt NPs gather at the beam illumination area, and then form aggregates with chain network structures. It is also determined that the NPs attach to each other at their {111} surfaces.
- 20 April 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (SD) , SD1021
Open AccessHigh-resolution STEM observation of the dynamics of Pt nanoparticles in a liquid
The dynamics of Pt nanoparticles (NPs) in water are observed by high-resolution scanning transmission electron microscopy with a home-made static sandwich-type liquid cell (LC). Carbon is coated on both sides of the membrane windows of the LC to make them conductive. The slow motion of Pt NPs in thin water droplets enables us to acquire high-resolution scanning transmission electron microscopy images. Using a dose rate of 3 × 10 5 e nm −2 s, some Pt NPs with a diameter of less than 2 nm disappear into the water, some move around, and others repeatedly attach to and detach from each other. The density of Pt NPs larger than 2 nm remains unchanged with further observation. However, by increasing the dose rate to 5.3 × 10 5 e nm −2 s, the Pt NPs gather at the beam illumination area, and then form aggregates with chain network structures. It is also determined that the NPs attach to each other at their {111} surfaces.
- Open Access
- 11 March 2022
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 71 (3) , 181-186
Effect of amorphous carbon coating on the performance of liquid phase transmission electron microscopy (LP-TEM) and the dynamics of enclosed Pt nano-colloids
Ultra-thin silicon nitride (SiN) membranes are critical in microfabrication-based liquid cells (LCs) for transmission electron microscopy (TEM). This study used a homemade LC with a 50-nm SiN membrane to study the dynamics of 2.58-nm platinum (Pt) nanoparticles (NPs) in approximately 200-nm-deep water. When a strong beam with electron flux ranging from 2.5 × 103 to 1.4 × 106 e−/(nm2 s) was applied to resolve the NPs, the beam caused NP aggregation and even drilled a hole on the top membrane. The hole drilling was prevented by coating a 1–4-nm-thick amorphous carbon layer on both sides of the membrane. The NP aggregation rate also decreased with increasing carbon thickness. After overcoming the aforementioned issues, lattice fringes of the Pt NPs were visible when the NPs were attached to the membrane of the 4-nm-carbon-coated LC containing a thin liquid layer. The effects of the electron beam and carbon on the LC and Pt NPs were investigated and discussed. This work provides a reference for LC-TEM research using strong electron beams.
- 11 March 2022
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 71 (3) , 181-186
Open AccessEffect of amorphous carbon coating on the performance of liquid phase transmission electron microscopy (LP-TEM) and the dynamics of enclosed Pt nano-colloids
Ultra-thin silicon nitride (SiN) membranes are critical in microfabrication-based liquid cells (LCs) for transmission electron microscopy (TEM). This study used a homemade LC with a 50-nm SiN membrane to study the dynamics of 2.58-nm platinum (Pt) nanoparticles (NPs) in approximately 200-nm-deep water. When a strong beam with electron flux ranging from 2.5 × 103 to 1.4 × 106 e−/(nm2 s) was applied to resolve the NPs, the beam caused NP aggregation and even drilled a hole on the top membrane. The hole drilling was prevented by coating a 1–4-nm-thick amorphous carbon layer on both sides of the membrane. The NP aggregation rate also decreased with increasing carbon thickness. After overcoming the aforementioned issues, lattice fringes of the Pt NPs were visible when the NPs were attached to the membrane of the 4-nm-carbon-coated LC containing a thin liquid layer. The effects of the electron beam and carbon on the LC and Pt NPs were investigated and discussed. This work provides a reference for LC-TEM research using strong electron beams.
- Open Access
- 15 December 2020
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 70 (4) , 327-332
Fabrication of a liquid cell for in situ transmission electron microscopy
Liquid cell transmission electron microscopy (LCTEM) enables imaging of dynamic processes in liquid with high spatial and temporal resolution. The widely used liquid cell (LC) consists of two stacking microchips with a thin wet sample sandwiched between them. The vertically overlapped electron-transparent membrane windows on the microchips provide passage for the electron beam. However, microchips with imprecise dimensions usually cause poor alignment of the windows and difficulty in acquiring high-quality images. In this study, we developed a new and efficient microchip fabrication process for LCTEM with a large viewing area (180 µm × 40 µm) and evaluated the resultant LC. The new positioning reference marks on the surface of the Si wafer dramatically improve the precision of dicing the wafer, making it possible to accurately align the windows on two stacking microchips. The precise alignment led to a liquid thickness of 125.6 nm close to the edge of the viewing area. The performance of our LC was demonstrated by in situ transmission electron microscopy imaging of the dynamic motions of 2-nm Pt particles. This versatile and cost-effective microchip production method can be used to fabricate other types of microchips for in situ electron microscopy.
- 15 December 2020
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 70 (4) , 327-332
Open AccessFabrication of a liquid cell for in situ transmission electron microscopy
Liquid cell transmission electron microscopy (LCTEM) enables imaging of dynamic processes in liquid with high spatial and temporal resolution. The widely used liquid cell (LC) consists of two stacking microchips with a thin wet sample sandwiched between them. The vertically overlapped electron-transparent membrane windows on the microchips provide passage for the electron beam. However, microchips with imprecise dimensions usually cause poor alignment of the windows and difficulty in acquiring high-quality images. In this study, we developed a new and efficient microchip fabrication process for LCTEM with a large viewing area (180 µm × 40 µm) and evaluated the resultant LC. The new positioning reference marks on the surface of the Si wafer dramatically improve the precision of dicing the wafer, making it possible to accurately align the windows on two stacking microchips. The precise alignment led to a liquid thickness of 125.6 nm close to the edge of the viewing area. The performance of our LC was demonstrated by in situ transmission electron microscopy imaging of the dynamic motions of 2-nm Pt particles. This versatile and cost-effective microchip production method can be used to fabricate other types of microchips for in situ electron microscopy.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 265-268
Adaptive Inverse Control for Two-Links Flexible Manipulator
The elastic vibrations of two-link manipulators are decoupled from the flexible manipulator for vertical planar two-links flexible manipulators. And the system was decomposed into two subsystems, slow-changing subsystem and fast-changing subsystem. An adaptive inverse controller based on model-reference is established for slow-changing subsystem. The fast-changing subsystem was deal with as disturb signal from system. The simulation results show that the proposed method not only can accurately and fast track the tip trajectory of manipulator, but also can effectively damp the elastic vibrations of two links manipulator, and is strongly robust to the variation of system parameters. The characteristic of this method is that each equivalent vibration parameters can be adaptively estimated and compensated respectively, so it is simple and easy to implement.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 265-268
Adaptive Inverse Control for Two-Links Flexible Manipulator
The elastic vibrations of two-link manipulators are decoupled from the flexible manipulator for vertical planar two-links flexible manipulators. And the system was decomposed into two subsystems, slow-changing subsystem and fast-changing subsystem. An adaptive inverse controller based on model-reference is established for slow-changing subsystem. The fast-changing subsystem was deal with as disturb signal from system. The simulation results show that the proposed method not only can accurately and fast track the tip trajectory of manipulator, but also can effectively damp the elastic vibrations of two links manipulator, and is strongly robust to the variation of system parameters. The characteristic of this method is that each equivalent vibration parameters can be adaptively estimated and compensated respectively, so it is simple and easy to implement.