Pichoy Danial
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Pichoy Danial has a total of 103 co-authors. Here are the top co-authors by number of shared publications:
Emmanuel Lansac
8 shared publicationsPascal Leprince
Department of Cardiovascular and Thoracic Surgery, Sorbonne University, Institute of Cardiology, Pitié-Salpêtrière Hospital, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France
8 shared publicationsMathieu Debauchez
Department of Cardiovascular and Thoracic Surgery, Sorbonne University, Pitié-Salpêtrière Hospital, AP-HP, 47-83, boulevard de l'Hôpital, 75013 Paris, France
5 shared publicationsPierre Demondion
Department of Cardiovascular and Thoracic Surgery, Institute of Cardiology, Sorbonne University, Pitié-Salpêtrière Hospital, Assistance Publique-Hôpitaux de Paris (AP-HP) , Paris
5 shared publicationsGuillaume Lebreton
Department of Cardiovascular and Thoracic Surgery, Sorbonne University, Institute of Cardiology, Pitié-Salpêtrière Hospital, Public Assistance Hospitals of Paris (AP-HP), Paris, France
3 shared publicationsAdrien Bouglé
Clinical Research Group (GRC) 29, Sorbonne University, Public Assistance Hospitals of Paris (AP-HP), Diagnostics, Radiology, Functional Investigations, Anatomopathology, Nuclear Medicine Medical University Departments, Department of Anesthesia and Resuscitation-, Institute of Cardiology, Pitié-Salpêtrière Hospital, Paris, France
2 shared publications
Latest Publications
- 24 September 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Traitement de l'insuffisance cardiaque à fraction d'éjection préservée par une mini-pompe centrifuge de décharge
L'insuffisance cardiaque à fraction d'éjection préservée (ICFEP) représente environ 50 % des cas d'insuffisance cardiaque et constitue un enjeu majeur de santé publique en raison de sa prévalence croissante et de l'absence de traitement efficace sur la mortalité. Elle se caractérise par une élévation des pressions de remplissage du ventricule gauche, responsable d'une congestion pulmonaire et de symptômes invalidants. Les traitements pharmacologiques actuels ont montré des résultats décevants, avec un impact limité sur la survie, justifiant le développement de nouvelles approches thérapeutiques interventionnelles. Parmi celles-ci, les stratégies de décharge du cœur gauche ont émergé comme une piste prometteuse. Les dispositifs de shunt interauriculaire, bien que physiopathologiquement pertinents, n'ont pas démontré de bénéfice clinique significatif et exposent à un risque de surcharge du cœur droit. D'autres approches, telles que la péricardectomie percutanée ou la neuromodulation, présentent des résultats encore préliminaires. Dans ce contexte, cette thèse propose une approche innovante reposant sur l'utilisation d'une micro-pompe centrifuge de décharge atriale gauche, implantable entre l'oreillette gauche et le système artériel, permettant de réduire les pressions atrio-pulmonaires sans augmenter le débit pulmonaire. L'objectif principal est d'évaluer la faisabilité, l'efficacité hémodynamique et l'hémocompatibilité de ce dispositif dans un modèle in vitro. Le travail s'articule en plusieurs étapes. Une première étude a permis de concevoir et d'optimiser le design de la pompe à l'aide de simulations numériques et de tests sur banc en boucle fermée. Les résultats montrent une capacité efficace de décharge du cœur gauche avec des performances hydrauliques adaptées à un faible débit. Une deuxième étude a évalué l'hémocompatibilité du dispositif, en analysant les contraintes de cisaillement et leur impact sur les éléments figurés du sang. Des optimisations géométriques, notamment du diamètre de la roue, ont permis de réduire significativement le risque de traumatisme sanguin. Enfin, une étude expérimentale d'hémolyse sur sang hépariné a été réalisée. Elle a permis de proposer un modèle original de « spectre hémolytique » décrivant le comportement de la pompe selon ses conditions de fonctionnement. Une modélisation algébrique des surfaces hémolytiques a été développée, permettant de prédire le niveau d'hémolyse et d'optimiser le fonctionnement du dispositif. Le niveau d'hémolyse de la pompe s'est trouvé compatible avec une implantation humaine. En conclusion, ce travail démontre la faisabilité et le potentiel thérapeutique d'une micro-pompe centrifuge de décharge atriale dans l'ICFEP. Cette approche pourrait représenter une alternative prometteuse aux stratégies actuelles, sous réserve de validations précliniques et cliniques complémentaires.
- 24 September 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Traitement de l'insuffisance cardiaque à fraction d'éjection préservée par une mini-pompe centrifuge de décharge
L'insuffisance cardiaque à fraction d'éjection préservée (ICFEP) représente environ 50 % des cas d'insuffisance cardiaque et constitue un enjeu majeur de santé publique en raison de sa prévalence croissante et de l'absence de traitement efficace sur la mortalité. Elle se caractérise par une élévation des pressions de remplissage du ventricule gauche, responsable d'une congestion pulmonaire et de symptômes invalidants. Les traitements pharmacologiques actuels ont montré des résultats décevants, avec un impact limité sur la survie, justifiant le développement de nouvelles approches thérapeutiques interventionnelles. Parmi celles-ci, les stratégies de décharge du cœur gauche ont émergé comme une piste prometteuse. Les dispositifs de shunt interauriculaire, bien que physiopathologiquement pertinents, n'ont pas démontré de bénéfice clinique significatif et exposent à un risque de surcharge du cœur droit. D'autres approches, telles que la péricardectomie percutanée ou la neuromodulation, présentent des résultats encore préliminaires. Dans ce contexte, cette thèse propose une approche innovante reposant sur l'utilisation d'une micro-pompe centrifuge de décharge atriale gauche, implantable entre l'oreillette gauche et le système artériel, permettant de réduire les pressions atrio-pulmonaires sans augmenter le débit pulmonaire. L'objectif principal est d'évaluer la faisabilité, l'efficacité hémodynamique et l'hémocompatibilité de ce dispositif dans un modèle in vitro. Le travail s'articule en plusieurs étapes. Une première étude a permis de concevoir et d'optimiser le design de la pompe à l'aide de simulations numériques et de tests sur banc en boucle fermée. Les résultats montrent une capacité efficace de décharge du cœur gauche avec des performances hydrauliques adaptées à un faible débit. Une deuxième étude a évalué l'hémocompatibilité du dispositif, en analysant les contraintes de cisaillement et leur impact sur les éléments figurés du sang. Des optimisations géométriques, notamment du diamètre de la roue, ont permis de réduire significativement le risque de traumatisme sanguin. Enfin, une étude expérimentale d'hémolyse sur sang hépariné a été réalisée. Elle a permis de proposer un modèle original de « spectre hémolytique » décrivant le comportement de la pompe selon ses conditions de fonctionnement. Une modélisation algébrique des surfaces hémolytiques a été développée, permettant de prédire le niveau d'hémolyse et d'optimiser le fonctionnement du dispositif. Le niveau d'hémolyse de la pompe s'est trouvé compatible avec une implantation humaine. En conclusion, ce travail démontre la faisabilité et le potentiel thérapeutique d'une micro-pompe centrifuge de décharge atriale dans l'ICFEP. Cette approche pourrait représenter une alternative prometteuse aux stratégies actuelles, sous réserve de validations précliniques et cliniques complémentaires.
- Open Access
- 12 September 2026
- Published by Elsevier in JTCVS Techniques
Use of pulmonary wall patch as leaflet replacement material during aortic valve repair
- 12 September 2026
- Published by Elsevier in JTCVS Techniques
Open AccessUse of pulmonary wall patch as leaflet replacement material during aortic valve repair
- Open Access
- 19 March 2026
- Published by Elsevier in JTCVS Techniques
- Vol. 37, 102314
Quadricuspid aortic valve repair: Tricuspidization with a double-ring annuloplasty
- 19 March 2026
- Published by Elsevier in JTCVS Techniques
- Vol. 37, 102314
Open AccessQuadricuspid aortic valve repair: Tricuspidization with a double-ring annuloplasty
- 26 December 2024
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 120 (3) , 487-493
Lower Ministernotomy: An Approach for Treating All Valvulopathies?
- 26 December 2024
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 120 (3) , 487-493
Lower Ministernotomy: An Approach for Treating All Valvulopathies?
- 26 August 2024
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 66 (5)
Incidence and outcomes of prosthetic valve thrombosis during peripheral extracorporeal membrane oxygenation
OBJECTIVES: In the context of postcardiotomy cardiogenic shock (PCCS) following valve replacement surgery, it may be necessary to implant a peripheral veno-arterial extracorporeal membrane oxygenation (pVA-ECMO). This procedure, however, carries a risk of prosthetic valve thrombosis. The aim of this retrospective study was to describe the incidence and outcomes of prosthetic valve thrombosis after VA-ECMO support for PCCS and to report the associated risk factors. METHODS: All consecutive adult patients who received pVA-ECMO for PCCS following a valve replacement procedure between January 2015 and October 2019 in our institution were included in this retrospective study. Outcome variables were prosthetic valve thrombosis, 30-day and hospital survival, pVA-ECMO-associated adverse events and surgery-related adverse events. RESULTS: During the 4-year study period, 549 patients received pVA-ECMO for PCCS. Among them, 152 had undergone a valve replacement procedure and 9 of these developed prosthetic valve thrombosis. The incidence of valve thrombosis at 30 days was 7.5 ± 2%. The cumulative incidence of prosthetic valve thrombosis was significantly lower with pVA-ECMO + intra-aortic balloon pump versus VA-ECMO alone (1.4 ± 1.4% vs 13.7 ± 4.7%, P = 0.021, respectively). Intra-aortic balloon pump use associated with pVA-ECMO (versus pVA-ECMO alone) was an independent protective factor against hospital death [odds ratio = 0.180 (0.068–0.478), P = 0.001]. CONCLUSIONS: After PCCS following valve replacement surgery, peripheral femoro-femoral VA-ECMO is associated with a low risk of acute valve thrombosis especially when associated with an intra-aortic balloon pump.
- 26 August 2024
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 66 (5)
Incidence and outcomes of prosthetic valve thrombosis during peripheral extracorporeal membrane oxygenation
OBJECTIVES: In the context of postcardiotomy cardiogenic shock (PCCS) following valve replacement surgery, it may be necessary to implant a peripheral veno-arterial extracorporeal membrane oxygenation (pVA-ECMO). This procedure, however, carries a risk of prosthetic valve thrombosis. The aim of this retrospective study was to describe the incidence and outcomes of prosthetic valve thrombosis after VA-ECMO support for PCCS and to report the associated risk factors. METHODS: All consecutive adult patients who received pVA-ECMO for PCCS following a valve replacement procedure between January 2015 and October 2019 in our institution were included in this retrospective study. Outcome variables were prosthetic valve thrombosis, 30-day and hospital survival, pVA-ECMO-associated adverse events and surgery-related adverse events. RESULTS: During the 4-year study period, 549 patients received pVA-ECMO for PCCS. Among them, 152 had undergone a valve replacement procedure and 9 of these developed prosthetic valve thrombosis. The incidence of valve thrombosis at 30 days was 7.5 ± 2%. The cumulative incidence of prosthetic valve thrombosis was significantly lower with pVA-ECMO + intra-aortic balloon pump versus VA-ECMO alone (1.4 ± 1.4% vs 13.7 ± 4.7%, P = 0.021, respectively). Intra-aortic balloon pump use associated with pVA-ECMO (versus pVA-ECMO alone) was an independent protective factor against hospital death [odds ratio = 0.180 (0.068–0.478), P = 0.001]. CONCLUSIONS: After PCCS following valve replacement surgery, peripheral femoro-femoral VA-ECMO is associated with a low risk of acute valve thrombosis especially when associated with an intra-aortic balloon pump.
- 24 November 2023
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 167 (5) , 1533-1542.e6
Outcomes of aortic valve repair in children stratified by complexity: Which outcome for which lesion?
- 24 November 2023
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 167 (5) , 1533-1542.e6
Outcomes of aortic valve repair in children stratified by complexity: Which outcome for which lesion?
- 18 August 2023
- Published by Elsevier in Archives of Cardiovascular Diseases
- Vol. 116 (10) , 453-459
Outcomes of aortic valve-sparing root replacement with cusp repair in connective tissue disease
- 18 August 2023
- Published by Elsevier in Archives of Cardiovascular Diseases
- Vol. 116 (10) , 453-459
Outcomes of aortic valve-sparing root replacement with cusp repair in connective tissue disease
- 1 August 2023
- Published by AME Publishing Company in ASVIDE
- Vol. 10, 132
Annular stabilization in remodelling technique.
- 1 August 2023
- Published by AME Publishing Company in ASVIDE
- Vol. 10, 132
Annular stabilization in remodelling technique.
- Open Access
- 1 July 2023
- Published by AME Publishing Company in Annals of Cardiothoracic Surgery
- Vol. 12 (4) , 386-388
Annular stabilization in remodelling technique
Annular stabilization in remodelling technique
- 1 July 2023
- Published by AME Publishing Company in Annals of Cardiothoracic Surgery
- Vol. 12 (4) , 386-388
Open AccessAnnular stabilization in remodelling technique
Annular stabilization in remodelling technique
- Open Access
- 17 March 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (3) , 366
Hemodynamic Evaluation of a Centrifugal Left Atrial Decompression Pump for Heart Failure with Preserved Ejection Fraction
This article discusses a new continuous flow mini pump that has been developed to improve symptoms and prognosis in patients with Heart Failure with Preserved Ejection Fraction (HFpEF), for which there are currently no established treatments. The pump is designed to discharge a reduced percentage of blood volume from the left atrium to the subclavian artery, clamped at the bifurcation with the aortic arch. The overall specifications, design parameters, and hemodynamics of this new device are discussed, along with data from in vitro circulation loop tests and numerical simulations. The article also compares the results for two configurations of the pump with respect to key indicators of hemocompatibility used in blood pump development.
- 17 March 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (3) , 366
Open AccessHemodynamic Evaluation of a Centrifugal Left Atrial Decompression Pump for Heart Failure with Preserved Ejection Fraction
This article discusses a new continuous flow mini pump that has been developed to improve symptoms and prognosis in patients with Heart Failure with Preserved Ejection Fraction (HFpEF), for which there are currently no established treatments. The pump is designed to discharge a reduced percentage of blood volume from the left atrium to the subclavian artery, clamped at the bifurcation with the aortic arch. The overall specifications, design parameters, and hemodynamics of this new device are discussed, along with data from in vitro circulation loop tests and numerical simulations. The article also compares the results for two configurations of the pump with respect to key indicators of hemocompatibility used in blood pump development.