Mingyu Zhou
Mingyu Zhou has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Haitian Wang
Global Energy Interconnection Research Institute Europe GmbH,Berlin,Germany
3 shared publicationsChong Zhang
Global Energy Interconnection Research Institute Co., Ltd., State Key Laboratory of Adcanced Transmission Technology,Beijing,China
2 shared publications- Ruoyu Xu
Global Energy Interconnection Research Institute Europe GmbH
2 shared publications - Shanika Yasantha Matharage
The University of Manchester Manchester UK
2 shared publications Yuzhen Zhou
Global Energy Interconnect Res Inst Europe GmbH, Kantstr 162, D-10623 Berlin, Germany
2 shared publications- Zhongdong Wang
The University of Manchester Manchester UK
2 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 148732-148744
Investigation Into Effects of Advanced Material Modifications on Dynamic Cathode Spot Evolution
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 148732-148744
Open AccessInvestigation Into Effects of Advanced Material Modifications on Dynamic Cathode Spot Evolution
- Open Access
- 26 September 2023
- Published by Elsevier in Mechanics of Materials
- Vol. 187
Effects of the graphene/metal interface on elastic properties of Cu and W matrices: Molecular dynamics simulation
- 26 September 2023
- Published by Elsevier in Mechanics of Materials
- Vol. 187
Open AccessEffects of the graphene/metal interface on elastic properties of Cu and W matrices: Molecular dynamics simulation
- 11 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Interface Stress Simulation of 200kV Gas-filled Plug-in DC Cable Termination
The cable termination is one of the vulnerable parts of the whole system. For oil-filled terminations, internal breakdown can produce severe damage to the surrounding equipment and human beings. At present, the rated voltage of gas-filled plug-in AC cable terminations is up to 550 kV and a lot of engineering and application experience shows that the gas-filled plug-in cable terminations have the benefits of no isolation liquids, shorter installation time and compacter design. In order to introduce the advantages of plug-in cable termination of AC power systems for DC power systems, it is necessary to carry out simulation modeling research on plug-in DC cable terminations. Based on the accumulated experience in the development of DC cable accessories, in this paper, a model of a 200 kV plug-in DC cable termination is presented and used to simulate the interfacial electric field under typical conditions according to relevant type test standards for DC cable systems.
- 11 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Interface Stress Simulation of 200kV Gas-filled Plug-in DC Cable Termination
The cable termination is one of the vulnerable parts of the whole system. For oil-filled terminations, internal breakdown can produce severe damage to the surrounding equipment and human beings. At present, the rated voltage of gas-filled plug-in AC cable terminations is up to 550 kV and a lot of engineering and application experience shows that the gas-filled plug-in cable terminations have the benefits of no isolation liquids, shorter installation time and compacter design. In order to introduce the advantages of plug-in cable termination of AC power systems for DC power systems, it is necessary to carry out simulation modeling research on plug-in DC cable terminations. Based on the accumulated experience in the development of DC cable accessories, in this paper, a model of a 200 kV plug-in DC cable termination is presented and used to simulate the interfacial electric field under typical conditions according to relevant type test standards for DC cable systems.
- 11 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Partial Discharge Measurement of Power Module Packaging Insulation Under Square Wave with Short Transition Time Based on SHF-Down-Mixing Method
Exploring the partial discharge (PD) characteristics of power modules under square wave high electric fields with short rise and fall time is of great significance for improving the reliability of its packaging insulation. In this paper, a PD detection method based on super high frequency (SHF, 3-30 GHz) technique and signal down-mixing principle is applied to detect the PD under square wave. The power module packaging insulation specimen consisting of metal baseplate, direct bonding copper (DBC), substrate and housing is fabricated. A repetitive square wave generator is built to supply high voltage square waves with short transition time. PD experiments are performed under square wave and sinusoidal wave. Experimental results show that the SHF-down-mixing PD detection system can effectively suppress the electromagnetic interference (EMI) from the square wave and extract PD signals successfully. As the radius of the electrode corner increases, the partial discharge inception voltage (PDIV) values under the sinusoidal wave also gradually increases. The PDIV under square wave does not show a monotonically increasing and is usually higher than that under sinusoidal wave probably because of the effect of space charge accumulation.
- 11 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Partial Discharge Measurement of Power Module Packaging Insulation Under Square Wave with Short Transition Time Based on SHF-Down-Mixing Method
Exploring the partial discharge (PD) characteristics of power modules under square wave high electric fields with short rise and fall time is of great significance for improving the reliability of its packaging insulation. In this paper, a PD detection method based on super high frequency (SHF, 3-30 GHz) technique and signal down-mixing principle is applied to detect the PD under square wave. The power module packaging insulation specimen consisting of metal baseplate, direct bonding copper (DBC), substrate and housing is fabricated. A repetitive square wave generator is built to supply high voltage square waves with short transition time. PD experiments are performed under square wave and sinusoidal wave. Experimental results show that the SHF-down-mixing PD detection system can effectively suppress the electromagnetic interference (EMI) from the square wave and extract PD signals successfully. As the radius of the electrode corner increases, the partial discharge inception voltage (PDIV) values under the sinusoidal wave also gradually increases. The PDIV under square wave does not show a monotonically increasing and is usually higher than that under sinusoidal wave probably because of the effect of space charge accumulation.
- 6 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Partial Discharge Detection on 80 kV DC XLPE Cable with Artificial Defects under DC Voltage
Extruded cross-linked polyethylene (XLPE) cables have become the preferred choice for the VSC-HVDC, due to benefits like easier production, transportation, and installation compared with MI cable. For AC cables, partial discharge testing is a vital method to evaluate the condition of the cable. However, there is significantly less experience regarding the behavior of partial discharge under DC conditions. It is well known that failures arise more often in accessories than in the cable itself. In order to evaluate partial discharges for a typical installation defect, a sharp transition edge between the outer semicon and the insulation layer has been prepared on an 80kV DC-cable system. Under different cable conductor temperatures, partial discharge tests with DC voltage steps have been performed with and without pulsed xray. For comparison, PD measurements at AC have also been performed on the DC-cable. Finally, the partial discharge inception voltage (PDIV) under DC and AC has been compared, and the dependence of temperature and X-ray pulses for DC partial discharge is investigated.
- 6 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Partial Discharge Detection on 80 kV DC XLPE Cable with Artificial Defects under DC Voltage
Extruded cross-linked polyethylene (XLPE) cables have become the preferred choice for the VSC-HVDC, due to benefits like easier production, transportation, and installation compared with MI cable. For AC cables, partial discharge testing is a vital method to evaluate the condition of the cable. However, there is significantly less experience regarding the behavior of partial discharge under DC conditions. It is well known that failures arise more often in accessories than in the cable itself. In order to evaluate partial discharges for a typical installation defect, a sharp transition edge between the outer semicon and the insulation layer has been prepared on an 80kV DC-cable system. Under different cable conductor temperatures, partial discharge tests with DC voltage steps have been performed with and without pulsed xray. For comparison, PD measurements at AC have also been performed on the DC-cable. Finally, the partial discharge inception voltage (PDIV) under DC and AC has been compared, and the dependence of temperature and X-ray pulses for DC partial discharge is investigated.
- 6 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Research progress of advanced fluoropolymer dielectric materials for solid film capacitors
The performances of dielectric film capacitors depend directly on the dielectric materials. High-performance capacitors must be supported by dielectric materials with high dielectric properties and high energy storage density. The dielectric constant of conventional dielectric materials has inherent contradiction with its dielectric strength, therefore, the development of a new film dielectric material with excellent dielectric performance and suitable for efficient energy storage density is conducive to greatly increasing the capacity of capacitors and miniaturization of applications. This paper introduces the research progress of high-performance with nanofiller modified film materials, discusses the modification technology on improving the electrical properties, and discusses the feasible blending, grafting and nano modification technologies of polypropylene. The analysis shows that the modification of nano - blend polypropylene can improve the dielectric constant and dielectric strength of materials.
- 6 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Research progress of advanced fluoropolymer dielectric materials for solid film capacitors
The performances of dielectric film capacitors depend directly on the dielectric materials. High-performance capacitors must be supported by dielectric materials with high dielectric properties and high energy storage density. The dielectric constant of conventional dielectric materials has inherent contradiction with its dielectric strength, therefore, the development of a new film dielectric material with excellent dielectric performance and suitable for efficient energy storage density is conducive to greatly increasing the capacity of capacitors and miniaturization of applications. This paper introduces the research progress of high-performance with nanofiller modified film materials, discusses the modification technology on improving the electrical properties, and discusses the feasible blending, grafting and nano modification technologies of polypropylene. The analysis shows that the modification of nano - blend polypropylene can improve the dielectric constant and dielectric strength of materials.