Vincent Obiozo Eze
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vincent Obiozo Eze has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Okenwa Izeji Okoli
Department of Mechanical Engineering, Herff College of Engineering, University of Memphis, Memphis, TN 38152, USA
2 shared publications - Chetanna Iwuagwu
High-Performance Materials Institute, College of Engineering, Florida A&M University–Florida State University, 2525 Pottsdamer Street, Tallahassee, FL 32310, USA
1 shared publication - Lucas Braga Carani
High-Performance Materials Institute, FAMU-FSU College of Engineering, 2525 Pottsdamer Street, Tallahassee, FL 32310, USA
1 shared publication - Nafiza Anjum
High-Performance Materials Institute, College of Engineering, Florida Agricultural and Mechanical University (FAMU)-Florida State University (FSU), Tallahassee, FL 32310, USA
1 shared publication - Okunzuwa Austine Ekuase
Department of Industrial and Manufacturing Engineering, Florida A&M University, S M L King Jr Blvd, Tallahassee, FL 32307, USA
1 shared publication
Latest Publications
- Top Cited PapersOpen Access
- 13 June 2022
- Published by MDPI AG in Journal of Composites Science
- Vol. 6 (6) , 172
A Review on the Out-of-Autoclave Process for Composite Manufacturing
Composite materials have gained increased usage due to their unique characteristic of a high-stiffness-to-weight ratio. High-performing composite materials are produced in the autoclave by applying elevated pressure and temperature. However, the process is characterized by numerous disadvantages, such as long cycle time, massive investment, costly tooling, and excessive energy consumption. As a result, composite manufacturers seek a cheap alternative to reduce cost and increase productivity. The out-of-autoclave (OoA) process manufactures composites by applying vacuum, pressure, and heat outside of the autoclave. This review discusses the common out-of-autoclave processes for various applications. The theoretical and practical merits and demerits are presented, and areas for future research are discussed.
- 13 June 2022
- Published by MDPI AG in Journal of Composites Science
- Vol. 6 (6) , 172
Top Cited PapersOpen AccessA Review on the Out-of-Autoclave Process for Composite Manufacturing
Composite materials have gained increased usage due to their unique characteristic of a high-stiffness-to-weight ratio. High-performing composite materials are produced in the autoclave by applying elevated pressure and temperature. However, the process is characterized by numerous disadvantages, such as long cycle time, massive investment, costly tooling, and excessive energy consumption. As a result, composite manufacturers seek a cheap alternative to reduce cost and increase productivity. The out-of-autoclave (OoA) process manufactures composites by applying vacuum, pressure, and heat outside of the autoclave. This review discusses the common out-of-autoclave processes for various applications. The theoretical and practical merits and demerits are presented, and areas for future research are discussed.
- Open Access
- 18 December 2020
- Published by MDPI AG in Journal of Composites Science
- Vol. 4 (4) , 190
Performance Analysis of Embedded Mechanoluminescence-Perovskite Self-Powered Pressure Sensor for Structural Health Monitoring
Recent developments in sensing technologies have triggered a lot of research interest in exploring novel self-powered, inexpensive, compact and flexible pressure sensors with the potential for structural health monitoring (SHM) applications. Herein, we assessed the performance of an embedded mechanoluminescent (ML) and perovskite pressure sensor that integrates the physical principles of mechanoluminescence and perovskite materials. For a continuous in-situ SHM, it is crucial to evaluate the capabilities of the sensing device when embedded into a composite structure. An experimental study of how the sensor is affected by the embedment process into a glass fiber-reinforced composite has been conducted. A series of devices with and without ML were embedded within a composite laminate, and the signal responses were collected under different conditions. We also demonstrated a successful encapsulation process in order for the device to withstand the composite manufacturing conditions. The results show that the sensor exhibits distinct signals when subjected to different load conditions and can be used for the in-situ SHM of advanced composite structures.
- 18 December 2020
- Published by MDPI AG in Journal of Composites Science
- Vol. 4 (4) , 190
Open AccessPerformance Analysis of Embedded Mechanoluminescence-Perovskite Self-Powered Pressure Sensor for Structural Health Monitoring
Recent developments in sensing technologies have triggered a lot of research interest in exploring novel self-powered, inexpensive, compact and flexible pressure sensors with the potential for structural health monitoring (SHM) applications. Herein, we assessed the performance of an embedded mechanoluminescent (ML) and perovskite pressure sensor that integrates the physical principles of mechanoluminescence and perovskite materials. For a continuous in-situ SHM, it is crucial to evaluate the capabilities of the sensing device when embedded into a composite structure. An experimental study of how the sensor is affected by the embedment process into a glass fiber-reinforced composite has been conducted. A series of devices with and without ML were embedded within a composite laminate, and the signal responses were collected under different conditions. We also demonstrated a successful encapsulation process in order for the device to withstand the composite manufacturing conditions. The results show that the sensor exhibits distinct signals when subjected to different load conditions and can be used for the in-situ SHM of advanced composite structures.