Seungman Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Seungman Kim has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Jeong Seok Oh
Department of Ultra Precision Machines and Systems, Korea Institute of Machinery and Materials, Daejeon, South Korea
2 shared publications - Seung-Woo Kim
Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Science Town, Daejeon 34141, South Korea
2 shared publications - Wooram Kim
Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Yuseong-gu, Daejeon 34141, Republic of Korea
2 shared publications - Young-Jin Kim
Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Science Town, Daejeon, 34141, South Korea.
2 shared publications Dong Jun Kim
Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
1 shared publication- Heesuk Jang
4th Research and Development Institute, Agency for Defense Development, Yuseong, Daejeon, South Korea
1 shared publication
Latest Publications
- Open Access
- 27 September 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-10
Graphene-enabled laser lift-off for ultrathin displays
Laser lift-off (LLO) of ultrathin polyimide (PI) films is important in the manufacturing of ultrathin displays. However, conventional LLO technologies face challenges in separating the ultrathin PI films without causing mechanical and electrical damage to integrated devices. Here, we propose a graphene-enabled laser lift-off (GLLO) method to address the challenges. The GLLO method is developed by integrating chemical vapor deposition (CVD)-grown graphene at the interface between a transparent carrier and an ultrathin PI film, exhibiting improved processability and lift-off quality. In particular, the GLLO method significantly mitigates plastic deformation of the PI film and minimizes carbonaceous residues remaining on the carrier. The role of graphene is attributed to three factors: enhancement of interfacial UV absorption, lateral heat diffusion, and adhesion reduction, and experimentations and numerical simulations verify the mechanism. Finally, it is demonstrated that the GLLO method separates ultrathin organic light-emitting diode (OLED) devices without compromising performance. We believe that this work will pave the way for utilizing CVD graphene in various laser-based manufacturing applications.
- 27 September 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-10
Open AccessGraphene-enabled laser lift-off for ultrathin displays
Laser lift-off (LLO) of ultrathin polyimide (PI) films is important in the manufacturing of ultrathin displays. However, conventional LLO technologies face challenges in separating the ultrathin PI films without causing mechanical and electrical damage to integrated devices. Here, we propose a graphene-enabled laser lift-off (GLLO) method to address the challenges. The GLLO method is developed by integrating chemical vapor deposition (CVD)-grown graphene at the interface between a transparent carrier and an ultrathin PI film, exhibiting improved processability and lift-off quality. In particular, the GLLO method significantly mitigates plastic deformation of the PI film and minimizes carbonaceous residues remaining on the carrier. The role of graphene is attributed to three factors: enhancement of interfacial UV absorption, lateral heat diffusion, and adhesion reduction, and experimentations and numerical simulations verify the mechanism. Finally, it is demonstrated that the GLLO method separates ultrathin organic light-emitting diode (OLED) devices without compromising performance. We believe that this work will pave the way for utilizing CVD graphene in various laser-based manufacturing applications.
- Open Access
Open-Air Testing of Dual-Comb Time-of-Flight Measurement
We configured a long-distance ranging apparatus to test the principle of dual-comb time-of-flight measurement using ultrashort lasers. Emphasis was given to the evaluation of open-air performance quantitatively in terms of the measurement resolution and stability. The test results revealed that our dual-comb asynchronous optical pulse sampling permits micrometer-resolved ranging with a repeatability of 2.05 μm over a 648 m distance in dry weather conditions. Further atmospheric effects were evaluated in three different weather conditions with corresponding Allan deviations. Finally, the capability of simultaneous determination of multiple targets was verified with the potential of advanced industrial applications, such as manufacturing, surveying, metrology, and geodesy.
Open AccessOpen-Air Testing of Dual-Comb Time-of-Flight Measurement
We configured a long-distance ranging apparatus to test the principle of dual-comb time-of-flight measurement using ultrashort lasers. Emphasis was given to the evaluation of open-air performance quantitatively in terms of the measurement resolution and stability. The test results revealed that our dual-comb asynchronous optical pulse sampling permits micrometer-resolved ranging with a repeatability of 2.05 μm over a 648 m distance in dry weather conditions. Further atmospheric effects were evaluated in three different weather conditions with corresponding Allan deviations. Finally, the capability of simultaneous determination of multiple targets was verified with the potential of advanced industrial applications, such as manufacturing, surveying, metrology, and geodesy.
- Open Access
Improved Self-Calibration of a Multilateration System Based on Absolute Distance Measurement
Multilateration tracking systems (MLTSs) are used in industrial three-dimensional (3D) coordinate measuring applications. For high-precision measurement, system parameters must be calibrated properly in advance. For an MLTS using absolute distance measurement (ADM), the conventional self-calibration method significantly reduces estimation efficiency because all system parameters are estimated simultaneously using a complicated residual function. This paper presents a novel self-calibration method that optimizes ADM to reduce the number of system parameters via highly precise and separate estimations of dead paths. Therefore, the residual function to estimate the tracking station locations can be simplified. By applying a suitable mathematical procedure and solving the initial guess problem without the aid of an external device, estimation accuracy of the system parameters is significantly improved. In three self-calibration experiments, with ADM repeatability of approximately 3.4 µm, the maximum deviation of the system parameters estimated by the proposed self-calibration method was 68.6 µm, while the maximum deviation estimated by the conventional self-calibration method was 711.9 µm. Validation of 3D coordinate measurements in a 1000 mm × 1000 mm × 1000 mm volume showed good agreement between the proposed ADM-based MLTS and a commercial laser tracker, where the maximum difference based on the standard deviation was 17.7 µm. Conversely, the maximum difference was 98.8 µm using the conventional self-calibration method. These results confirmed the efficiency and feasibility of the proposed self-calibration method.
Open AccessImproved Self-Calibration of a Multilateration System Based on Absolute Distance Measurement
Multilateration tracking systems (MLTSs) are used in industrial three-dimensional (3D) coordinate measuring applications. For high-precision measurement, system parameters must be calibrated properly in advance. For an MLTS using absolute distance measurement (ADM), the conventional self-calibration method significantly reduces estimation efficiency because all system parameters are estimated simultaneously using a complicated residual function. This paper presents a novel self-calibration method that optimizes ADM to reduce the number of system parameters via highly precise and separate estimations of dead paths. Therefore, the residual function to estimate the tracking station locations can be simplified. By applying a suitable mathematical procedure and solving the initial guess problem without the aid of an external device, estimation accuracy of the system parameters is significantly improved. In three self-calibration experiments, with ADM repeatability of approximately 3.4 µm, the maximum deviation of the system parameters estimated by the proposed self-calibration method was 68.6 µm, while the maximum deviation estimated by the conventional self-calibration method was 711.9 µm. Validation of 3D coordinate measurements in a 1000 mm × 1000 mm × 1000 mm volume showed good agreement between the proposed ADM-based MLTS and a commercial laser tracker, where the maximum difference based on the standard deviation was 17.7 µm. Conversely, the maximum difference was 98.8 µm using the conventional self-calibration method. These results confirmed the efficiency and feasibility of the proposed self-calibration method.