GTGeorgios Tziatzios

Georgios Tziatzios

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Georgios Tziatzios has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Covid-19: exploring the “new normal” in gastroenterology training

    by K Ekmektzoglou, G Tziatzios, K Siau, K.M. Pawlak, T Rokkas, K Triantafyllou, M Arvanitakis, P Gkolfakis

    The coronavirus disease 2019 (COVID-19) pandemic has led to unprecedented disruptions in fellowship training programs worldwide. In gastroenterology, the strain in healthcare service provision and the emphasis on preventing viral transmission has adversely impacted hands-on training opportunities, with trainees facing the constant pressure to meet training requirements under the continuous threat of viral transmission. Emerging evidence highlight the scale of the problem, specifically with regard to endoscopy competence due to cancellation of elective endoscopic procedures, provision of inpatient and outpatient consultative care as well as academic education and the mental well-being of trainees. As such, it has been necessary for trainees, trainers and training programs collectively to adapt to these challenges and incorporate novel and adaptive solutions to circumvent these training barriers. This review aims to summarise data on the global impact of COVID-19 on gastroenterology training and the practical interventions that could be implemented.


  • Open Access

    Left Atrial Strain Identifies Increased Atrial Ectopy in Patients with Beta-Thalassemia Major

    by Maria Vlachou, Vasileios Kamperidis, Efthymia Vlachaki, Georgios Tziatzios, Despoina Pantelidou, Afroditi Boutou, Chrysa Apostolou, Despoina Papadopoulou, George Giannakoulas, Haralambos Karvounis

    Patients with beta-thalassemia major (β-ΤΜ) may develop cardiac arrhythmias through a multifactorial mechanism. The current study evaluated the association of cardiac structure and function on echocardiography with atrial ectopic burden on 24-hour tape recording in β-ΤΜ patients. This prospective study included consecutive β-ΤΜ patients. Demographic, laboratory, echocardiographic, cardiac magnetic resonance (CMR) T2* and 24-hour tape recording data were prospectively collected. The patients were classified according to the median value of premature atrial contractions (PACs) on 24-hour tape. In total, 50 β-TM patients (37.6 ± 9.1 years old, 50% male) were divided in 2 groups; PACs ≤ 24/day and > 24/day. Patients with PACs > 24/day were treated with blood transfusion for a longer period of time (39.0 ± 8.6 vs. 32.0 ± 8.9 years, p < 0.007), compared to their counterparts. Older age (OR: 1.121, 95% CI: 1.032–1.217, p = 0.007), longer duration of blood transfusion (OR:1.101, 95% CI:1.019–1.188, p = 0.014), larger LV end-diastolic diameter (OR: 4.522, 95% CI:1.009–20.280, p = 0.049), higher values of LA peak systolic strain (OR: 0.869, 95% CI: 0.783–0.964, p = 0.008), higher MV E/E′ average (OR: 1.407, 95% CI: 1.028–1.926, p = 0.033) and higher right ventricular systolic pressure (OR: 1.147, 95% CI: 1.039–1.266, p = 0.006) were univariably associated with PACs > 24/day. LA peak systolic strain remained significantly associated with PACs > 24/day after adjusting for the duration of blood transfusions or for CMR T2*. The multivariable model including blood transfusion duration and LA peak systolic strain was the most closely associated with PACs > 24/day. Receiver operating characteristic curve analysis identified a left atrial peak systolic strain of 31.5%, as the best cut-off value (83% sensitivity, 68% specificity) for prediction of PACs > 24/day. In β-TM patients, LA peak systolic strain was associated with the atrial arrhythmia burden independently to the duration of blood transfusions and CMR T2*.


  • Open Access

    Torsades de Pointes and Prolonged Self-Terminating Ventricular Fibrillation Induced by Amiodarone

    by Georgios D. Tziatzios, Matthaios Didagelos, Ioannis Tziatzios, Stavros Hadjimiltiades, Theodoros Karamitsos

    A 71-year-old man with a recent diagnosis of pneumonia developed paroxysmal atrial fibrillation and was admitted to the cardiology service. Amiodarone was administered intravenously to restore sinus rhythm. Significant prolongation of the QT interval (QTc = 640ms) was noted and an exceedingly prolonged (over 3 minutes), self-terminating, episode of ventricular flutter/fibrillation occurred during bedside monitoring. The event was terminated without first converting to a more organized ventricular rhythm and without any adverse neurological sequelae. Apart from the long duration of ventricular fibrillation and its spontaneous termination, our case highlights the importance of the continuous heart rhythm monitoring in patients with extreme QT interval prolongation.