ASAndrew K. Swanson

Andrew K. Swanson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andrew K. Swanson has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A portable nitrogen dioxide instrument using cavity-enhanced absorption spectroscopy

    by Steven A. Bailey, Reem A. Hannun, Andrew K. Swanson, Thomas F. Hanisco

    The Portable (2.7 kg) Cavity-enhanced Absorption of Nitrogen Dioxide (PCAND) instrument for measuring in situ nitrogen dioxide (NO2) was developed using incoherent broadband cavity-enhanced absorption spectroscopy (IBBCEAS). An LED light source centered at 408 nm was coupled to a cavity 15 cm in length, achieving an effective optical pathlength of ∼520 m. Precision was measured as 94 pptv (1 s). To date, we have flown this instrument on three balloon test flights. This instrument records data on an SD card and outputs data (via an RS232 port) to external devices including a commercial radiosonde (iMet) for real-time data downlink.


  • Open Access

    A Portable Nitrogen Dioxide Instrument Using Cavity-Enhanced Absorption Spectroscopy

    by Steven A. Bailey, Reem A. Hannun, Andrew K. Swanson, Thomas F. Hanisco

    The Portable (2.7 kg) Cavity-enhanced Absorption of Nitrogen Dioxide (PCAND) instrument for measuring in situ nitrogen dioxide (NO2) was developed using incoherent, broadband cavity-enhanced absorption spectroscopy (IBBCEAS). An LED light source centered at 408 nm was coupled to a cavity 15 cm in length, achieving an effective optical pathlength of ~520 m. Our precision was measured as 94 pptv (1 s). To date, we have flown this instrument on 3 balloon and 1 UAV test flights. This instrument records data to an SD card and outputs data (via an RS232 port) to external devices including a commercial radiosonde (iMet) for real-time data downlink.

  • Open Access

    A cavity-enhanced ultraviolet absorption instrument for high-precision, fast-time-response ozone measurements

    by Reem A. Hannun, Andrew K. Swanson, Steven A. Bailey, Thomas F. Hanisco, T. Paul Bui, Ilann Bourgeois, Jeff Peischl, Thomas B. Ryerson

    The NASA Rapid Ozone Experiment (ROZE) is a broadband cavity-enhanced UV (ultraviolet) absorption instrument for the detection of in situ ozone (O3). ROZE uses an incoherent LED (light-emitting diode) light source coupled to a high-finesse optical cavity to achieve an effective pathlength of ∼ 104 m. Due to its high sensitivity and small optical cell volume, ROZE demonstrates a 1σ precision of 80 pptv (parts per trillion by volume) in 0.1 s and 31 pptv in a 1 s integration time, as well as an e-fold time response of 50 ms. ROZE can be operated in a range of field environments, including low- and high-altitude research aircraft, and is particularly suited to O3 vertical-flux measurements using the eddy covariance technique. ROZE was successfully integrated aboard the NASA DC-8 aircraft during July–September 2019 and validated against a well-established chemiluminescence measurement of O3. A flight within the marine boundary layer also demonstrated flux measurement capabilities, and we observed a mean O3 deposition velocity of 0.029 ± 0.005 cm s−1 to the ocean surface. The performance characteristics detailed below make ROZE a robust, versatile instrument for field measurements of O3.


  • Open Access

    A Cavity-Enhanced UV Absorption Instrument for High Precision, Fast Time Response Ozone Measurements

    by Reem A. Hannun, Andrew K. Swanson, Steven A. Bailey, Thomas F. Hanisco, T. Paul Bui, Ilann Bourgeois, Jeff Peischl, Thomas B. Ryerson

    The NASA Rapid Ozone Experiment (ROZE) is a broadband cavity-enhanced UV absorption instrument for the detection of in situ ozone (O3). ROZE uses an incoherent LED light source coupled to a high-finesse optical cavity to achieve an effective pathlength of ~ 104 m. Due to its high-sensitivity and small optical cell volume, ROZE demonstrates a 1σ precision of 80 pptv (0.1 s) and 31 pptv (1 s), as well as a 1/e response time of 50 ms. ROZE can be operated in a range of field environments, including low- and high-altitude research aircraft, and is particularly suited to O3 vertical flux measurements using the eddy covariance technique. ROZE was successfully integrated aboard the NASA DC-8 aircraft during July–September 2019 and validated against a well-established chemiluminescence measurement of O3. A flight within the marine boundary layer also demonstrated flux measurement capabilities, and we observed a mean O3 deposition velocity of 0.029 ± 0.005 cm s–1 to the ocean surface. The performance characteristics detailed below make ROZE a robust, versatile instrument for field measurements of O3.

  • Open Access

    CAFE: a new, improved nonresonant laser-induced fluorescence instrument for airborne in situ measurement of formaldehyde

    by Jason M. St. Clair, Andrew K. Swanson, Steven A. Bailey, Thomas F. Hanisco

    NASA Compact Airborne Formaldehyde Experiment (CAFE) is a nonresonant laser-induced fluorescence instrument for airborne in situ measurement of formaldehyde (HCHO). The instrument is described here with highlighted improvements from the predecessor instrument, COmpact Formaldehyde FluorescencE Experiment (COFFEE). CAFE uses a 480 mW, 80 kHz laser at 355 nm to excite HCHO and detects the resulting fluorescence in the 420–550 nm range. The fluorescence is acquired at 5 ns resolution for 500 ns and the unique time profile of the HCHO fluorescence provides measurement selectivity. CAFE achieves a 1σ precision of 160 pptv (1 s) and 90 pptv (10 s) for [HCHO] = 0 pptv. The accuracy of CAFE, using its curve-fitting data processing, is estimated as ±20 % of [HCHO] + 100 pptv. CAFE has successfully flown on multiple aircraft platforms and is particularly well-suited to high-altitude research aircraft or small air quality research aircraft where high sensitivity is required but operator interaction and instrument payload is limited.


  • Open Access

    CAFE: a new, improved non-resonant laser-induced fluorescence instrument for airborne in situ measurement of formaldehyde

    by Jason M. St. Clair, Andrew K. Swanson, Steven A. Bailey, Thomas F. Hanisco

    NASA Compact Airborne Formadehyde Experiment (CAFE) is a non-resonant laser-induced fluorescence instrument for airborne in situ measurement of formaldehyde (HCHO). The instrument is described here with highlighted improvements from the predecessor instrument, COmpact Formaldehyde FluorescencE Experiment (COFFEE). CAFE uses a 480 mW, 80 kHz laser at 355 nm to excite HCHO and detects the resulting fluorescence in the 420–480 nm range. The fluorescence is acquired at 5 ns resolution for 500 ns and the unique time profile of the HCHO fluorescence provides measurement selectivity. CAFE achieves a 1-sigma precision of 160 pptv (1 s) and 90 pptv (10 s) for [HCHO] = 0 pptv. CAFE has successfully flown on multiple aircraft platforms and is particularly well-suited to high altitude research aircraft or small air quality research aircraft where high sensitivity is required but operator interaction and instrument payload is limited.

  • Open Access

    The NASA Carbon Airborne Flux Experiment (CARAFE): instrumentation and methodology

    by Glenn M. Wolfe, S. Randy Kawa, Thomas F. Hanisco, Reem A. Hannun, Paul A. Newman, Andrew Swanson, Steve Bailey, John Barrick, K. Lee Thornhill, Glenn Diskin, et al.

    The exchange of trace gases between the Earth's surface and atmosphere strongly influences atmospheric composition. Airborne eddy covariance can quantify surface fluxes at local to regional scales (1–1000 km), potentially helping to bridge gaps between top-down and bottom-up flux estimates and offering novel insights into biophysical and biogeochemical processes. The NASA Carbon Airborne Flux Experiment (CARAFE) utilizes the NASA C-23 Sherpa aircraft with a suite of commercial and custom instrumentation to acquire fluxes of carbon dioxide, methane, sensible heat, and latent heat at high spatial resolution. Key components of the CARAFE payload are described, including the meteorological, greenhouse gas, water vapor, and surface imaging systems. Continuous wavelet transforms deliver spatially resolved fluxes along aircraft flight tracks. Flux analysis methodology is discussed in depth, with special emphasis on quantification of uncertainties. Typical uncertainties in derived surface fluxes are 40–90 % for a nominal resolution of 2 km or 16–35 % when averaged over a full leg (typically 30–40 km). CARAFE has successfully flown two missions in the eastern US in 2016 and 2017, quantifying fluxes over forest, cropland, wetlands, and water. Preliminary results from these campaigns are presented to highlight the performance of this system.


  • Open Access

    A new non-resonant laser-induced fluorescence instrument for the airborne in situ measurement of formaldehyde

    by Jason M. St. Clair, Andrew K. Swanson, Steven A. Bailey, Glenn M. Wolfe, Josette E. Marrero, Laura T. Iraci, John G. Hagopian, Thomas F. Hanisco

    A new in situ instrument for gas-phase formaldehyde (HCHO), COmpact Formaldehyde FluorescencE Experiment (COFFEE), is presented. COFFEE utilizes non-resonant laser-induced fluorescence (NR-LIF) to measure HCHO, with 300 mW of 40 kHz 355 nm laser output exciting multiple HCHO absorption features. The resulting HCHO fluorescence is collected at 5 ns resolution, and the fluorescence time profile is fit to yield the ambient HCHO mixing ratio. Typical 1σ precision at ∼ 0 pptv HCHO is 150 pptv for 1 s data. The compact instrument was designed to operate with minimal in-flight operator interaction and infrequent maintenance (1–2 times per year). COFFEE fits in the wing pod of the Alpha Jet stationed at the NASA Ames Research Center and has successfully collected HCHO data on 27 flights through 2017 March. The frequent flights, combined with a potentially long-term data set, makes the Alpha Jet a promising platform for validation of satellite-based column HCHO.


  • Open Access

    Supplementary material to "The NASA Carbon Airborne Flux Experiment (CARAFE): Instrumentation and Methodology"

    by Glenn M. Wolfe, S. Randy Kawa, Thomas F. Hanisco, Reem A. Hannun, Paul A. Newman, Andrew Swanson, Steve Bailey, John Barrick, K. Lee Thornhill, Glenn Diskin, et al.